Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
West J Emerg Med ; 23(5): 706-715, 2022 Aug 19.
Artigo em Inglês | MEDLINE | ID: mdl-36205675

RESUMO

INTRODUCTION: Previous studies suggest improved intubation success using video laryngoscopy (VL) vs direct laryngoscopy (DL), yet recent randomized trials have not shown clear benefit of one method over the other. These studies, however, have generally excluded difficult airways and rapid sequence intubation. In this study we looked to compare first-pass success (FPS) rates between VL and DL in adult emergency department (ED) patients with difficult airways. METHODS: We conducted a secondary analysis of prospectively collected observational data in the National Emergency Airway Registry (NEAR) (January 2016-December 2018). Variables included demographics, indications, methods, medications, devices, difficult airway characteristics, success, and adverse events. We included adult ED patients intubated with VL or DL who had difficult airways identified by gestalt or anatomic predictors. We stratified VL by hyperangulated (HAVL) vs standard geometry VL (SGVL). The primary outcome was FPS, and the secondary outcome was comparison of adverse event rates between groups. Data analyses included descriptive statistics with cluster-adjusted 95% confidence intervals (CI). RESULTS: Of 18,123 total intubations, 12,853 had a predicted or identified anatomically difficult airway. The FPS for difficult airways was 89.1% (95% CI 85.9-92.3) with VL and 77.7% (95% CI 75.7-79.7) with DL (P <0.00001). The FPS rates were similar between VL subtypes for all difficult airway characteristics except airways with blood or vomit, where SGVL FPS (87.3%; 95% CI 85.8-88.8) was slightly better than HAVL FPS (82.4%; 95% CI, 80.3-84.4). Adverse event rates were similar except for esophageal intubations and vomiting, which were both less common in VL than DL. Esophageal intubations occurred in 0.4% (95% CI 0.1-0.7) of VL attempts and 1.5% (95% CI 1.1-1.9) of DL attempts. Vomiting occurred in 0.6% (95% CI 0.5-0.7) of VL attempts and 1.4% (95% CI 0.9-1.9) of DL attempts. CONCLUSION: Analysis of the NEAR database demonstrates higher first-pass success with VL compared to DL in patients with predicted or anatomically difficult airways, and reduced rate of esophageal intubations and vomiting.


Assuntos
Laringoscópios , Laringoscopia , Adulto , Serviço Hospitalar de Emergência , Humanos , Intubação Intratraqueal/métodos , Laringoscopia/métodos , Sistema de Registros , Gravação em Vídeo , Vômito
2.
Acad Emerg Med ; 27(2): 100-108, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31957174

RESUMO

OBJECTIVE: The objective was to compare first-attempt intubation success using direct laryngoscopy augmented by laryngeal manipulation, ramped patient positioning, and use of a bougie (A-DL) with unaided video laryngoscopy (VL) in adult emergency department (ED) intubations. METHODS: This study was a secondary analysis of a multicenter prospective observational database of ED intubations from the National Emergency Airway Registry (NEAR). We compared all VL procedures to seven exploratory permutations of A-DL using multivariable regression models. We further stratified by blade shape into hyperangulated VL (HA-VL) and standard-geometry VL (SG-VL). We report differences in first-attempt intubation success and peri-intubation adverse events with cluster-adjusted odds ratios (ORs) with 95% confidence intervals (CIs). We report univariate comparisons in patient characteristics, difficult airway attributes, and intubation methods using descriptive statistics and OR with 95% CI. RESULTS: We analyzed 11,714 intubations performed from January 1, 2016, through December 31, 2017. Of these encounters, 6,938 underwent orotracheal intubation with either A-DL or unaided VL on first attempt. A-DL was used first in 3,936 (56.7%, 95% CI = 46.9 to 66.5) versus unaided VL in 3,002 (43.3%, 95% CI = 33.5 to 53.1). Of the A-DL first intubations 1,787 (45.4%) employed ramped positioning alone, 1,472 (37.4%) had external laryngeal manipulation (ELM), and 365 (9.3%) used a bougie. Rapid sequence intubation (RSI) was the most common method used in 5,602 (80.8%, 95% CI = 77.0 to 84.5) cases. First-attempt success was significantly higher with all VL (90.9%, 95% CI = 88.7 to 93.1) versus all A-DL (81.1%, 95% CI = 78.7 to 83.5) despite the VL group having more patients with reduced mouth opening, neck immobility, and an initial impression of airway difficult. Multivariable regression analyses controlling for indication, method, operator specialty and year of training, center clustering, and all registry-recorded difficult airway predictors revealed first-attempt success was higher with all unaided VL compared with any A-DL (adjusted OR [AOR] = 2.8, 95% CI = 2.4 to 3.3), DL with bougie (AOR = 2.7, 95% CI = 2.1 to 3.5), DL with ELM (AOR = 1.8, 95% CI = 1.5 to 2.2), DL with ramped positioning (AOR = 2.8, 95% CI = 2.3 to 3.3), or DL with ELM plus bougie (AOR = 2.8, 95% CI = 2.3 to 3.3). Subgroup analyses of HA-VL and SG-VL compared with any A-DL yielded similar results (AOR = 3.2, 95% CI = 2.6 to 3.0; and AOR = 2.4, 95% CI = 1.9 to 3.0, respectively). The propensity score-adjusted odds for first-attempt success with VL was also 2.8 (95% CI = 2.4 to 3.3). Fewer esophageal intubations were observed in the VL cohort (0.4% vs. 1.3%, AOR = 0.2, 95% CI = 0.1 to 0.5). CONCLUSIONS: Video laryngoscopy used without any augmenting maneuver, device, or technique results in higher first-attempt success than does DL that is augmented by use of a bougie, ELM, ramping, or combinations thereof.


Assuntos
Laringoscopia/métodos , Indução e Intubação de Sequência Rápida/métodos , Cirurgia Torácica Vídeoassistida/métodos , Adulto , Estudos de Casos e Controles , Serviço Hospitalar de Emergência/estatística & dados numéricos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pontuação de Propensão , Estudos Prospectivos , Indução e Intubação de Sequência Rápida/efeitos adversos , Indução e Intubação de Sequência Rápida/estatística & dados numéricos , Sistema de Registros
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...