Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 48
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
bioRxiv ; 2024 Feb 04.
Artigo em Inglês | MEDLINE | ID: mdl-38352456

RESUMO

Cholinergic signaling is involved with a variety of brain functions including learning and memory, attention, and behavioral state modulation. The spatiotemporal characteristics of neocortical acetylcholine (ACh) release in response to sensory inputs are poorly understood, but a lack of intra-region topographic organization of cholinergic projections from the basal forebrain has suggested diffuse release patterns and volume transmission. Here, we use mesoscopic imaging of fluorescent ACh sensors to show that visual stimulation results in ACh release patterns that conform to a retinotopic map of visual space in the mouse primary visual cortex, suggesting new modes of functional cholinergic signaling in cortical circuits.x.

2.
IEEE Trans Med Imaging ; 43(2): 638-648, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37703138

RESUMO

We introduce an ultrasound speckle decorrelation-based time-lagged functional ultrasound technique (tl-fUS) for the quantification of the relative changes in cerebral blood flow speed (rCBF [Formula: see text]), cerebral blood volume (rCBV) and cerebral blood flow (rCBF) during functional stimulations. Numerical simulations, phantom validations, and in vivo mouse brain experiments were performed to test the capability of tl-fUS to parse out and quantify the ratio change of these hemodynamic parameters. The blood volume change was found to be more prominent in arterioles compared to venules and the peak blood flow changes were around 2.5 times the peak blood volume change during brain activation, agreeing with previous observations in the literature. The tl-fUS shows the ability of distinguishing the relative changes of rCBFspeed, rCBV, and rCBF, which can inform specific physiological interpretations of the fUS measurements.


Assuntos
Neoplasias Encefálicas , Hemodinâmica , Animais , Camundongos , Volume Sanguíneo , Ultrassonografia , Encéfalo/diagnóstico por imagem , Circulação Cerebrovascular , Imageamento por Ressonância Magnética/métodos
3.
bioRxiv ; 2024 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-37986755

RESUMO

SIGNIFICANCE: Widefield microscopy of the entire dorsal part of mouse cerebral cortex enables large-scale (mesoscopic) imaging of neuronal activity with fluorescent indicators as well as hemodynamics via oxy- and deoxyhemoglobin absorption. Versatile and cost-effective imaging systems are needed for large-scale, color-multiplexed imaging of multiple fluorescent and intrinsic contrasts. AIM: Develop a system for mesoscopic imaging of two fluorescent and two reflectance channels. APPROACH: Excitation of red and green fluorescence is achieved through epi-illumination. Hemoglobin absorption imaging is achieved using 525- and 625nm LEDs positioned around the objective lens. An aluminum hemisphere placed between objective and cranial window provides diffuse illumination of the brain. Signals are recorded sequentially by a single sCMOS detector. RESULTS: We demonstrate performance of our imaging system by recording large-scale spontaneous and stimulus-evoked neuronal, cholinergic, and hemodynamic activity in awake head-fixed mice with a curved crystal skull window expressing the red calcium indicator jRGECO1a and the green acetylcholine sensor GRABACh3.0 . Shielding of illumination light through the aluminum hemisphere enables concurrent recording of pupil diameter changes. CONCLUSIONS: Our widefield microscope design with single camera can be used to acquire multiple aspects of brain physiology and is compatible with behavioral readouts of pupil diameter.

5.
Nat Neurosci ; 26(9): 1642-1650, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37604887

RESUMO

Genetically encoded voltage indicators (GEVIs) hold immense potential for monitoring neuronal population activity. To date, best-in-class GEVIs rely on one-photon excitation. However, GEVI imaging of dense neuronal populations remains difficult because out-of-focus background fluorescence produces low contrast and excess noise when paired with conventional one-photon widefield imaging methods. To address this challenge, we developed an imaging system capable of efficient, high-contrast GEVI imaging at near-kHz rates and demonstrate it for in vivo and ex vivo imaging applications in the mouse neocortex. Our approach uses simultaneous multiplane imaging to monitor activity within contiguous tissue volumes with no penalty in speed or requirement for high excitation power. This approach, multi-Z imaging with confocal detection (MuZIC), permits high signal-to-noise ratio voltage imaging in densely labeled neuronal populations and is compatible with imaging through micro-optics. Moreover, it minimizes artifacts associated with concurrent imaging and optogenetic photostimulation for all-optical electrophysiology.


Assuntos
Artefatos , Neocórtex , Animais , Camundongos , Microscopia Confocal , Optogenética , Fótons
6.
Opt Lett ; 48(14): 3805-3808, 2023 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-37450755

RESUMO

While two-photon fluorescence microscopy is a powerful platform for the study of functional dynamics in living cells and tissues, the bulk motion inherent to these applications causes distortions. We have designed a motion tracking module based on spectral domain optical coherence tomography which compliments a laser scanning two-photon microscope with real-time corrective feedback. The module can be added to fluorescent imaging microscopes using a single dichroic and without additional contrast agents. We demonstrate that the system can track lateral displacements as large as 10 µm at 5 Hz with latency under 14 ms and propose a scheme to extend the system to 3D correction with the addition of a remote focusing module. We also propose several ways to improve the module's performance by reducing the feedback latency. We anticipate that this design can be adapted to other imaging modalities, enabling the study of samples subject to motion artifacts at higher resolution.


Assuntos
Artefatos , Tomografia de Coerência Óptica , Movimento (Física) , Microscopia Confocal , Microscopia de Fluorescência
7.
Nat Neurosci ; 26(6): 924-925, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37264157
8.
Neurophotonics ; 10(4): 044302, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37215637

RESUMO

Significance: Fluorescence head-mounted microscopes, i.e., miniscopes, have emerged as powerful tools to analyze in-vivo neural populations but exhibit a limited depth-of-field (DoF) due to the use of high numerical aperture (NA) gradient refractive index (GRIN) objective lenses. Aim: We present extended depth-of-field (EDoF) miniscope, which integrates an optimized thin and lightweight binary diffractive optical element (DOE) onto the GRIN lens of a miniscope to extend the DoF by 2.8× between twin foci in fixed scattering samples. Approach: We use a genetic algorithm that considers the GRIN lens' aberration and intensity loss from scattering in a Fourier optics-forward model to optimize a DOE and manufacture the DOE through single-step photolithography. We integrate the DOE into EDoF-Miniscope with a lateral accuracy of 70 µm to produce high-contrast signals without compromising the speed, spatial resolution, size, or weight. Results: We characterize the performance of EDoF-Miniscope across 5- and 10-µm fluorescent beads embedded in scattering phantoms and demonstrate that EDoF-Miniscope facilitates deeper interrogations of neuronal populations in a 100-µm-thick mouse brain sample and vessels in a whole mouse brain sample. Conclusions: Built from off-the-shelf components and augmented by a customizable DOE, we expect that this low-cost EDoF-Miniscope may find utility in a wide range of neural recording applications.

9.
Neuroimage Clin ; 38: 103377, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36948140

RESUMO

Functional neuroimaging, which measures hemodynamic responses to brain activity, has great potential for monitoring recovery in stroke patients and guiding rehabilitation during recovery. However, hemodynamic responses after stroke are almost always altered relative to responses in healthy subjects and it is still unclear if these alterations reflect the underlying brain physiology or if the alterations are purely due to vascular injury. In other words, we do not know the effect of stroke on neurovascular coupling and are therefore limited in our ability to use functional neuroimaging to accurately interpret stroke pathophysiology. To address this challenge, we simultaneously captured neural activity, through fluorescence calcium imaging, and hemodynamics, through intrinsic optical signal imaging, during longitudinal stroke recovery. Our data suggest that neurovascular coupling was preserved in the chronic phase of recovery (2 weeks and 4 weeks post-stoke) and resembled pre-stroke neurovascular coupling. This indicates that functional neuroimaging faithfully represents the underlying neural activity in chronic stroke. Further, neurovascular coupling in the sub-acute phase of stroke recovery was predictive of long-term behavioral outcomes. Stroke also resulted in increases in global brain oscillations, which showed distinct patterns between neural activity and hemodynamics. Increased neural excitability in the contralesional hemisphere was associated with increased contralesional intrahemispheric connectivity. Additionally, sub-acute increases in hemodynamic oscillations were associated with improved sensorimotor outcomes. Collectively, these results support the use of hemodynamic measures of brain activity post-stroke for predicting functional and behavioral outcomes.


Assuntos
Acoplamento Neurovascular , Acidente Vascular Cerebral , Humanos , Acoplamento Neurovascular/fisiologia , Acidente Vascular Cerebral/diagnóstico por imagem , Encéfalo/diagnóstico por imagem , Hemodinâmica/fisiologia , Neuroimagem Funcional
10.
J Cereb Blood Flow Metab ; 43(4): 595-609, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36495178

RESUMO

Two photon microscopy and optical coherence tomography (OCT) are two standard methods for measuring flow speeds of red blood cells in microvessels, particularly in animal models. However, traditional two photon microscopy lacks the depth of field to adequately capture the full volumetric complexity of the cerebral microvasculature and OCT lacks the specificity offered by fluorescent labeling. In addition, the traditional raster scanning technique utilized in both modalities requires a balance of image frame rate and field of view, which severely limits the study of RBC velocities in the microvascular network. Here, we overcome this by using a custom two photon system with an axicon based Bessel beam to obtain volumetric images of the microvascular network with fluorescent specificity. We combine this with a novel scan pattern that generates pairs of frames with short time delay sufficient for tracking red blood cell flow in capillaries. We track RBC flow speeds in 10 or more capillaries simultaneously at 1 Hz in a 237 µm × 237 µm × 120 µm volume and quantified both their spatial and temporal variability in speed. We also demonstrate the ability to track flow speed changes around stalls in capillary flow and measure to 300 µm in depth.


Assuntos
Capilares , Circulação Cerebrovascular , Animais , Capilares/fisiologia , Velocidade do Fluxo Sanguíneo/fisiologia , Circulação Cerebrovascular/fisiologia , Encéfalo/irrigação sanguínea , Microvasos/diagnóstico por imagem
12.
Adv Funct Mater ; 32(25)2022 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-36381629

RESUMO

The Utah array powers cutting-edge projects for restoration of neurological function, such as BrainGate, but the underlying electrode technology has itself advanced little in the last three decades. Here, advanced dual-side lithographic microfabrication processes is exploited to demonstrate a 1024-channel penetrating silicon microneedle array (SiMNA) that is scalable in its recording capabilities and cortical coverage and is suitable for clinical translation. The SiMNA is the first penetrating microneedle array with a flexible backing that affords compliancy to brain movements. In addition, the SiMNA is optically transparent permitting simultaneous optical and electrophysiological interrogation of neuronal activity. The SiMNA is used to demonstrate reliable recordings of spontaneous and evoked field potentials and of single unit activity in chronically implanted mice for up to 196 days in response to optogenetic and to whisker air-puff stimuli. Significantly, the 1024-channel SiMNA establishes detailed spatiotemporal mapping of broadband brain activity in rats. This novel scalable and biocompatible SiMNA with its multimodal capability and sensitivity to broadband brain activity will accelerate the progress in fundamental neurophysiological investigations and establishes a new milestone for penetrating and large area coverage microelectrode arrays for brain-machine interfaces.

13.
Neurophotonics ; 9(3): 031901, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36204654

RESUMO

The guest editorial provides an introduction to Parts 1 and 2 of the Neurophotonics Special Section on Imaging Neuroimmune, Neuroglial, and Neurovascular Interfaces.

14.
PLoS Biol ; 20(10): e3001440, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-36301995

RESUMO

The cerebral cortex is organized in cortical layers that differ in their cellular density, composition, and wiring. Cortical laminar architecture is also readily revealed by staining for cytochrome oxidase-the last enzyme in the respiratory electron transport chain located in the inner mitochondrial membrane. It has been hypothesized that a high-density band of cytochrome oxidase in cortical layer IV reflects higher oxygen consumption under baseline (unstimulated) conditions. Here, we tested the above hypothesis using direct measurements of the partial pressure of O2 (pO2) in cortical tissue by means of 2-photon phosphorescence lifetime microscopy (2PLM). We revisited our previously developed method for extraction of the cerebral metabolic rate of O2 (CMRO2) based on 2-photon pO2 measurements around diving arterioles and applied this method to estimate baseline CMRO2 in awake mice across cortical layers. To our surprise, our results revealed a decrease in baseline CMRO2 from layer I to layer IV. This decrease of CMRO2 with cortical depth was paralleled by an increase in tissue oxygenation. Higher baseline oxygenation and cytochrome density in layer IV may serve as an O2 reserve during surges of neuronal activity or certain metabolically active brain states rather than reflecting baseline energy needs. Our study provides to our knowledge the first quantification of microscopically resolved CMRO2 across cortical layers as a step towards better understanding of brain energy metabolism.


Assuntos
Complexo IV da Cadeia de Transporte de Elétrons , Consumo de Oxigênio , Animais , Camundongos , Complexo IV da Cadeia de Transporte de Elétrons/metabolismo , Consumo de Oxigênio/fisiologia , Oxigênio/metabolismo , Córtex Cerebral/metabolismo , Encéfalo/fisiologia , Circulação Cerebrovascular
15.
Neurophotonics ; 9(Suppl 1): 013001, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35493335

RESUMO

Neurophotonics was launched in 2014 coinciding with the launch of the BRAIN Initiative focused on development of technologies for advancement of neuroscience. For the last seven years, Neurophotonics' agenda has been well aligned with this focus on neurotechnologies featuring new optical methods and tools applicable to brain studies. While the BRAIN Initiative 2.0 is pivoting towards applications of these novel tools in the quest to understand the brain, this status report reviews an extensive and diverse toolkit of novel methods to explore brain function that have emerged from the BRAIN Initiative and related large-scale efforts for measurement and manipulation of brain structure and function. Here, we focus on neurophotonic tools mostly applicable to animal studies. A companion report, scheduled to appear later this year, will cover diffuse optical imaging methods applicable to noninvasive human studies. For each domain, we outline the current state-of-the-art of the respective technologies, identify the areas where innovation is needed, and provide an outlook for the future directions.

16.
J Cereb Blood Flow Metab ; 42(3): 510-525, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-32515672

RESUMO

The cerebral cortex has a number of conserved morphological and functional characteristics across brain regions and species. Among them, the laminar differences in microvascular density and mitochondrial cytochrome c oxidase staining suggest potential laminar variability in the baseline O2 metabolism and/or laminar variability in both O2 demand and hemodynamic response. Here, we investigate the laminar profile of stimulus-induced intravascular partial pressure of O2 (pO2) transients to stimulus-induced neuronal activation in fully awake mice using two-photon phosphorescence lifetime microscopy. Our results demonstrate that stimulus-induced changes in intravascular pO2 are conserved across cortical layers I-IV, suggesting a tightly controlled neurovascular response to provide adequate O2 supply across cortical depth. In addition, we observed a larger change in venular O2 saturation (ΔsO2) compared to arterioles, a gradual increase in venular ΔsO2 response towards the cortical surface, and absence of the intravascular "initial dip" previously reported under anesthesia. This study paves the way for quantification of layer-specific cerebral O2 metabolic responses, facilitating investigation of brain energetics in health and disease and informed interpretation of laminar blood oxygen level dependent functional magnetic resonance imaging signals.


Assuntos
Córtex Cerebral/irrigação sanguínea , Circulação Cerebrovascular/fisiologia , Acoplamento Neurovascular/fisiologia , Imagem Óptica/métodos , Oxigênio/sangue , Animais , Feminino , Hemodinâmica/fisiologia , Camundongos , Camundongos Endogâmicos C57BL , Microscopia , Vigília
17.
Biomed Opt Express ; 12(6): 3571-3583, 2021 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-34221679

RESUMO

Laser speckle contrast imaging (LSCI) is a real-time full-field non-invasive technique, which is broadly applied to visualize blood flow in biomedical applications. In its foundation is the link between the speckle contrast and dynamics of light scattering particles-erythrocytes. The mathematical form describing this relationship, which is critical for accurate blood flow estimation, depends on the sample's light-scattering properties. However, in biological applications, these properties are often unknown, thus requiring assumptions to be made to perform LSCI analysis. Here, we review the most critical assumptions in the LSCI theory and simulate how they affect blood flow estimation accuracy. We show that the most commonly applied model can severely underestimate the flow change, particularly when imaging brain parenchyma or other capillary perfused tissue (e.g. skin) under ischemic conditions. Based on these observations and guided by the recent experimental results, we propose an alternative model that allows measuring blood flow changes with higher accuracy.

18.
Artigo em Inglês | MEDLINE | ID: mdl-33959688

RESUMO

Recent developments in optical microscopy, applicable for large-scale and longitudinal imaging of cortical activity in behaving animals, open unprecedented opportunities to gain a deeper understanding of neurovascular and neurometabolic coupling during different brain states. Future studies will leverage these tools to deliver foundational knowledge about brain state-dependent regulation of cerebral blood flow and metabolism as well as regulation as a function of brain maturation and aging. This knowledge is of critical importance to interpret hemodynamic signals observed with functional magnetic resonance imaging (fMRI).

19.
Opt Lett ; 46(7): 1744-1747, 2021 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-33793533

RESUMO

We report optical coherence tomography (OCT) imaging of localized fast optical signals (FOSs) arising from whisker stimulation in awake mice. The activated voxels were identified by fitting the OCT intensity signal time course with a response function over a time scale of a few hundred milliseconds after the whisker stimulation. The significantly activated voxels were shown to be localized to the expected brain region for whisker stimulation. The ability to detect functional stimulus-evoked, depth-resolved FOS with intrinsic contrast from the cortex provides a new tool for neural activity studies.


Assuntos
Sistema Nervoso/diagnóstico por imagem , Tomografia de Coerência Óptica/métodos , Animais , Camundongos
20.
Cereb Cortex ; 31(8): 3678-3700, 2021 07 05.
Artigo em Inglês | MEDLINE | ID: mdl-33749727

RESUMO

Despite ongoing advances in our understanding of local single-cellular and network-level activity of neuronal populations in the human brain, extraordinarily little is known about their "intermediate" microscale local circuit dynamics. Here, we utilized ultra-high-density microelectrode arrays and a rare opportunity to perform intracranial recordings across multiple cortical areas in human participants to discover three distinct classes of cortical activity that are not locked to ongoing natural brain rhythmic activity. The first included fast waveforms similar to extracellular single-unit activity. The other two types were discrete events with slower waveform dynamics and were found preferentially in upper cortical layers. These second and third types were also observed in rodents, nonhuman primates, and semi-chronic recordings from humans via laminar and Utah array microelectrodes. The rates of all three events were selectively modulated by auditory and electrical stimuli, pharmacological manipulation, and cold saline application and had small causal co-occurrences. These results suggest that the proper combination of high-resolution microelectrodes and analytic techniques can capture neuronal dynamics that lay between somatic action potentials and aggregate population activity. Understanding intermediate microscale dynamics in relation to single-cell and network dynamics may reveal important details about activity in the full cortical circuit.


Assuntos
Córtex Cerebral/fisiologia , Neurônios/fisiologia , Estimulação Acústica , Adulto , Animais , Estimulação Elétrica , Eletroencefalografia , Fenômenos Eletrofisiológicos , Epilepsia/fisiopatologia , Espaço Extracelular/fisiologia , Feminino , Humanos , Macaca mulatta , Imageamento por Ressonância Magnética , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Endogâmicos ICR , Microeletrodos , Pessoa de Meia-Idade , Córtex Somatossensorial/fisiologia , Análise de Ondaletas , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...