Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 91(7): 073506, 2020 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-32752844

RESUMO

Equilibrium analysis in fusion devices usually relies on plasma pressure profiles and magnetic measurements outside the plasma. The kinetic profiles can give indirect information about the equilibrium magnetic field, while the stationary magnetic diagnostics cannot resolve current distributions on a smaller scale. This work presents a reciprocating magnetic probe, designed to provide direct plasma response measurements of the magnetic field in the scrape-off layer of Wendelstein 7-X. Hardware design and frequency characteristics are discussed, and a post-processing technique for extending the lower frequency cutoff of the integration scheme is presented.

2.
Phys Rev Lett ; 123(2): 025002, 2019 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-31386539

RESUMO

For the first time, the optimized stellarator Wendelstein 7-X has operated with an island divertor. An operation regime in hydrogen was found in which the total plasma radiation approached the absorbed heating power without noticeable loss of stored energy. The divertor thermography recorded simultaneously a strong reduction of the heat load on all divertor targets, indicating almost complete power detachment. This operation regime was stably sustained over several energy confinement times until the preprogrammed end of the discharge. The plasma radiation is mainly due to oxygen and is located at the plasma edge. This plasma scenario is reproducible and robust at various heating powers, plasma densities, and gas fueling locations. These experimental results show that the island divertor concept actually works and displays good power dissipation potential, producing a promising exhaust concept for the stellarator reactor line.

3.
Rev Sci Instrum ; 90(3): 033502, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30927788

RESUMO

Ion flow velocity measurement in the edge and scraper-off layer region is beneficial to understand the confinement related phenomenon in fusion devices such as impurity transport and plays an important role in impurity control. During the Wendelstein 7-X (W7-X) operation phase 1.2a, a multi-channel (MC) Mach probe mounted on the multi-purpose manipulator has been used to measure radial profiles of edge ion flow velocity. This MC-Mach probe consists of two polar and two radial arrays of directional Langmuir pins (28 pins in total) serving for different aims, of which the polar arrays could obtain a polar distribution of ion saturation current, while the radial arrays can be used to study the dynamic process of a radially propagated event. In this paper, we report the observation of the radially outward propagation of a low frequency mode with a speed of around 200 m/s. The first measurement of the radial ion flow velocity profile using the MC-Mach probe in the boundary plasma of the W7-X with an island divertor will also be presented.

4.
Rev Sci Instrum ; 89(10): 10F111, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399723

RESUMO

The paper reports on the optimization process of the soft X-ray pulse height analyzer installed on the Wendelstein 7-X (W7-X) stellarator. It is a 3-channel system that records X-ray spectra in the range from 0.6 to 19.6 keV. X-ray spectra, with a temporal and spatial resolution of 100 ms and 2.5 cm (depending on selected slit sizes), respectively, are line integrated along a line-of-sight that crosses near to the plasma center. In the second W7-X operation phase with a carbon test divertor unit, light impurities, e.g., carbon and oxygen, were observed as well as mid- to high-Z elements, e.g., sulfur, chlorine, chromium, manganese, iron, and nickel. In addition, X-ray lines from several tracer elements have been observed after the laser blow-off injection of different impurities, e.g., silicon, titanium, and iron, and during discharges with prefill or a gas puff of neon or argon. These measurements were achieved by optimizing light absorber-foil selection, which defines the detected energy range, and remotely controlled pinhole size, which defines photon flux. The identification of X-ray lines was confirmed by other spectroscopic diagnostics, e.g., by the High-Efficiency XUV Overview Spectrometer, HEXOS, and high-resolution X-ray imaging spectrometer, HR-XIS.

5.
Rev Sci Instrum ; 89(10): 10G101, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399890

RESUMO

This paper reports on the design and the performance of the recently upgraded X-ray imaging spectrometer systems, X-ray imaging crystal spectrometer and high resolution X-ray imaging spectrometer, installed at the optimized stellarator Wendelstein 7-X. High resolution spectra of highly ionized, He-like Si, Ar, Ti, and Fe as well as H-like Ar have been observed. A cross comparison of ion and electron temperature profiles derived from a spectral fit and tomographic inversion of Ar and Fe spectra shows a reasonable match with both the spectrometers. The also measured impurity density profiles of Ar and Fe have peaked densities at radial positions that are in qualitative agreement with the expectations from the He-like impurity fractional abundances, given the measured temperature profiles. Repeated measurements of impurity decay times have been demonstrated with an accuracy of 1 ms via injection of non-recycling Ti, Fe, and Mo impurities using a laser blow-off system.

6.
Rev Sci Instrum ; 89(7): 073505, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30068134

RESUMO

We present a detailed overview and first results of the new laser blow-off system on the stellarator Wendelstein 7-X. The system allows impurity transport studies by the repetitive and controlled injection of different tracer ions into the plasma edge. A Nd:YAG laser is used to ablate a thin metal film, coated on a glass plate, with a repetition rate of up to 20 Hz. A remote-controlled adjustable optical system allows the variation of the laser spot diameter and enables the spot positioning to non-ablated areas on the target between laser pulses. During first experiments, clear spectral lines from higher ionization stages of the tracer ions have been observed in the X-ray to the extreme ultraviolet spectral range. The temporal behavior of the measured emission allows the estimate of transport properties, e.g., impurity transport times in the order of 100 ms. Although the strong injection of impurities is well detectable, the global plasma parameters are barely changed.

7.
Life Sci ; 60(24): 2191-7, 1997.
Artigo em Inglês | MEDLINE | ID: mdl-9188762

RESUMO

Human blood platelets were tested for the presence of mRNAs coding for tryptophan hydroxylase (TPOH) and hydroxy-indol-o-methyl-transferase (HIOMT). Total RNA was extracted from platelets (12.9 +/- 3.3 mg RNA/100 ml blood, mean +/- SEM of 6 preparations) and cDNA synthesized by reverse transcription using random hexamers, oligo-dT or TPOH- or HIOMT-specific primers, designed to amplify a 254 bp fragment for TPOH and a 301 bp fragment for HIOMT. Positive controls were performed using RNA extracted from human normal or tumoral pineal glands. The PCR products were analyzed by gel electrophoresis, transferred to a nylon membrane and hybridized with a 32P-labeled internal probe. When random hexamers, oligo-dT or specific primers were used for reverse transcription, amplification products of the predicted sizes were detectable following electrophoresis in the case of pineal glands and following transfer and hybridization in the case of platelets. These results show TPOH and HIOMT mRNAs to be present in human blood and support the hypothesis that serotonin and melatonin may be synthesized in blood and, more particularly, in platelets.


Assuntos
Acetilserotonina O-Metiltransferasa/genética , Plaquetas/química , RNA Mensageiro/sangue , Triptofano Hidroxilase/genética , Acetilserotonina O-Metiltransferasa/sangue , Southern Blotting , Eletroforese em Gel de Ágar , Humanos , Reação em Cadeia da Polimerase , Triptofano Hidroxilase/sangue
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...