Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Assunto principal
Intervalo de ano de publicação
1.
J Clin Med ; 13(9)2024 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-38731257

RESUMO

Background/Objectives: Lumbar lordotic curvature (LLC), closely associated with low back pain (LBP) when decreased, is infrequently assessed in clinical settings due to the spatiotemporal limitations of radiographic methods. To overcome these constraints, this study used an inertial measurement system to compare the magnitude and maintenance of LLC across various sitting conditions, categorized into three aspects: verbal instructions, chair type, and desk task types. Methods: Twenty-nine healthy participants were instructed to sit for 3 min with two wireless sensors placed on the 12th thoracic vertebra and the 2nd sacral vertebra. The lumbar lordotic angle (LLA) was measured using relative angles for the mediolateral axis and comparisons were made within each sitting category. Results: The maintenance of LLA (LLAdev) was significantly smaller when participants were instructed to sit upright (-3.7 ± 3.9°) compared to that of their habitual sitting posture (-1.2 ± 2.4°) (p = 0.001), while the magnitude of LLA (LLAavg) was significantly larger with an upright sitting posture (p = 0.001). LLAdev was significantly larger when using an office chair (-0.4 ± 1.1°) than when using a stool (-3.2 ± 7.1°) (p = 0.033), and LLAavg was also significantly larger with the office chair (p < 0.001). Among the desk tasks, LLAavg was largest during keyboard tasks (p < 0.001), followed by mouse and writing tasks; LLAdev showed a similar trend without statistical significance (keyboard, -1.2 ± 3.0°; mouse, -1.8 ± 2.2°; writing, -2.9 ± 3.1°) (p = 0.067). Conclusions: Our findings suggest that strategies including the use of an office chair and preference for computer work may help preserve LLC, whereas in the case of cueing, repetition may be necessary.

2.
Sensors (Basel) ; 21(23)2021 Dec 02.
Artigo em Inglês | MEDLINE | ID: mdl-34884059

RESUMO

Spirometer measurements can reflect cough strength but might not be routinely available for patients with severe neurological or medical conditions. A digital device that can record and help track abnormal cough sound changes serially in a noninvasive but reliable manner would be beneficial for monitoring such individuals. This report includes two cases of respiratory distress whose cough changes were monitored via assessments performed using recordings made with a digital device. The cough sounds were recorded using an iPad (Apple, Cupertino, CA, USA) through an embedded microphone. Cough sounds were recorded at the bedside, with no additional special equipment. The two patients were able to complete the recordings with no complications. The maximum root mean square values obtained from the cough sounds were significantly reduced when both cases were diagnosed with aspiration pneumonia. In contrast, higher values became apparent when the patients demonstrated a less severe status. Based on an analysis of our two cases, the patients' cough sounds recorded with a commercial digital device show promise as potential digital biomarkers that may reflect aspiration risk related to attenuated cough force. Serial monitoring aided the decision making to resume oral feeding. Future studies should further explore the clinical utility of this technique.


Assuntos
Tosse , Som , Biomarcadores , Tosse/diagnóstico , Testes Diagnósticos de Rotina , Humanos , Espirometria
3.
Ann Rehabil Med ; 39(3): 425-31, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26161349

RESUMO

OBJECTIVE: To observe changes in pharyngeal pressure during the swallowing process according to postures in normal individuals using high-resolution manometry (HRM). METHODS: Ten healthy volunteers drank 5 mL of water twice while sitting in a neutral posture. Thereafter, they drank the same amount of water twice in the head rotation and head tilting postures. The pressure and time during the deglutition process for each posture were measured with HRM. The data obtained for these two postures were compared with those obtained from the neutral posture. RESULTS: The maximum pressure, area, rise time, and duration in velopharynx (VP) and tongue base (TB) were not affected by changes in posture. In comparison, the maximum pressure and the pre-upper esophageal sphincter (UES) maximum pressure of the lower pharynx in the counter-catheter head rotation posture were lower than those in the neutral posture. The lower pharynx pressure in the catheter head tilting posture was higher than that in the counter-catheter head tilting. The changes in the VP peak and epiglottis, VP and TB peaks, and the VP onset and post-UES time intervals were significant in head tilting and head rotation toward the catheter postures, as compared with neutral posture. CONCLUSION: The pharyngeal pressure and time parameter analysis using HRM determined the availability of head rotation as a compensatory technique for safe swallowing. Tilting the head smoothes the progress of food by increasing the pressure in the pharynx.

4.
Ann Rehabil Med ; 38(2): 282-5, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24855626

RESUMO

Carpal tunnel release is required to treat patients with severe carpal tunnel syndrome. The regional anesthesia of the upper limb by brachial plexus block (BPB) may be a good alternative to general anesthesia for carpal tunnel release surgery, because it results in less complications. However, the regional anesthesia still has various side effects, such as hematoma, infection, and peripheral neuropathy. We hereby report a rare case of median nerve injury caused by BPB for carpal tunnel release.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA