Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Life (Basel) ; 12(11)2022 Nov 18.
Artigo em Inglês | MEDLINE | ID: mdl-36431058

RESUMO

Pre-treatment patient-specific quality assurance (QA) is critical to prevent radiation accidents. The electronic portal imaging device (EPID) is a dose measurement tool with good resolution and a low volume-averaging effect. EPIbeam­an EPID-based portal dosimetry software­has been newly installed in three institutions in Korea. This study evaluated the efficacy of the EPID-based patient-specific QA tool versus the PTW729 detector (a previously used QA tool) based on gamma criteria and planning target volume (PTV). A significant difference was confirmed through the R statistical analysis software. The average gamma passing rates of PTW729 and EPIbeam were 98.73% and 99.60% on 3 mm/3% (local), 96.66% and 97.91% on 2 mm/2% (local), and 88.41% and 74.87% on 1 mm/1% (local), respectively. The p-values between them were 0.015 (3 mm/3%, local), 0.084 (2 mm/2%, local), and less than 0.01 (1 mm/1%, local). Further, the average gamma passing rates of PTW 729 and EPIbeam according to PTV size were 99.55% and 99.91% (PTV < 150 cm3) and 97.91% and 99.28% (PTV > 150 cm3), respectively. The p-values between them were 0.087 (PTV < 150 cm3) and 0.036 (PTV > 150 cm3). These results confirm that EPIbeam can be an effective patient-specific QA tool.

2.
J Nanosci Nanotechnol ; 20(11): 6985-6991, 2020 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-32604546

RESUMO

Phosphor screens have attracted increasing global interest because they can aid the acquisition of high-quality images while simultaneously reducing exposure. However, although increasing the thickness of the phosphor screen increases exposure efficiency due to scattered light, it also leads to a broader light spread, which results in poorer resolution. Hence, in this study, we implemented a reflector using a mirror-coating technique on the surface of a phosphor screen and analyzed its characteristics in terms of luminescence intensity and resolution. We present the fabrication and measurement of the phosphor screen based on a reflector containing Gd2O2S:Tb. The phosphor screen containing the reflector can be fabricated via the screen-printing method and roll-to-roll sputtering method. In particular, when compared to the condition without a reflector, Al and Cu reflectors showed improvements in luminescence intensity of 15.7% and 12.2%, respectively, as well as lower full widths at half maximum of 11.45 and 9.08, respectively. This quantitatively demonstrates that Cu and Al are suitable reflector materials to improve exposure efficiency while maintaining resolution in radiography systems. Moreover, because we did not utilize an optical assembly, which improves the transmission efficiency by matching the different refractive indices of the phosphor screen and photo-detector, we believe that the quantity of photons could be further improved if the reflectors were applied to a commercial product. Thus, future studies using single-layer anti-reflector coating techniques with optical assemblies are warranted.

3.
Cancer Invest ; 33(5): 180-7, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25831242

RESUMO

We retrospectively reviewed 88 patients with oligometases in the para-aortic region from any controlled primary tumor site who were treated with stereotactic body radiotherapy (SBRT). The 5-year local control, disease-free survival, and overall survival rates were 83%, 31%, and 41%, respectively. A 90% tumor-control probability was predicted at a biological effective dose of 90 Gy. Severe gastrointestinal toxicities (grade ≥3) were observed in 2 of 88 patients (1%). The results of this study are limited by the retrospective nature of the study but could serve as the background and rationale for future prospective trials on SBRT-based treatment for oligometastses.


Assuntos
Neoplasias/radioterapia , Prognóstico , Radiocirurgia , Idoso , Intervalo Livre de Doença , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Metástase Neoplásica , Neoplasias/patologia , Neoplasias/cirurgia , Estudos Retrospectivos , Taxa de Sobrevida , Resultado do Tratamento
4.
J Korean Med Sci ; 25(4): 546-51, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20357996

RESUMO

The authors reviewed their experiences of external beam radiotherapy (EBR) as an initial treatment in retinoblastoma patients to determine its long-term effect on subsequent tumor control and complications. A total of 32 eyes in 25 patients that underwent EBR for retinoblastoma were reviewed retrospectively. The patients consisted of 21 boys and 4 girls of median age at treatment of 7.1 months. Radiation doses ranged from 35 to 59.4 Gy. The 10-yr ocular and patient survivals were 75.4% and 92.3%, respectively. Nine of the 32 eyes progressed; 7 of these were enucleated and 2 were salvaged by focal treatment. According to the Reese-Ellsworth classification, 4 of 5 eyes of Group II, 13 of 16 Group III eyes, 2 of 4 Group IV eyes, and 5 of 7 Group V eyes were retained, and of the 32 eyes, 13 had visual acuity better than 20/200. Eleven patients experienced a radiation-induced complication. No patient developed a second malignancy during follow-up. Despite the limited number of patients enrolled, EBR may provide a mean of preserving eyeball and vision for some advanced lesions.


Assuntos
Radioterapia/métodos , Neoplasias da Retina/radioterapia , Retinoblastoma/radioterapia , Criança , Pré-Escolar , Enucleação Ocular , Feminino , Humanos , Lactente , Coreia (Geográfico) , Masculino , Dosagem Radioterapêutica , Estudos Retrospectivos , Taxa de Sobrevida , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA