Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Dent J (Basel) ; 11(7)2023 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-37504227

RESUMO

BACKGROUND: Restoring bonding composite to silver diamine fluoride (SDF)-treated enamel is challenging. This study investigates if phosphoric acid etch restores composite bond strength to SDF-treated enamel using universal adhesives. METHODS: Twenty-four recently extracted permanent teeth were randomly divided into 4 (2 experimental (SDF) and 2 control (CTR)) groups: SDF+Water: SDF (1 min) then water rinse (15 mL); CTR+Water: no treatment and water rinse (15 mL); SDF+Etch+Water: SDF (1 min), 35% phosphoric acid (40 s) then water rinse (15 mL); CTR+Etch+Water no treatment, 35% phosphoric acid (40 s) then water rinse (15 mL). The enamel surface in all the groups was bonded (All-Bond Universal) to 4-5 mm composite blocks (Z-250). Each sample was sectioned, and 6-8 beams (1 mm × 1 mm) were selected. The micro-tensile bond strength was measured by dividing the micro-tensile force peak by the adhesive surface area. Univariate ANOVA and Chi-square were used for between-group comparisons with p < 0.05. RESULTS: SDF+Water had significantly lower tensile strength compared to all the groups (p < 0.05). Although no difference was found in the tensile strength between the SDF+Etch+Water and the CTR+Etch+Water, the SDF+Etch+Water had significantly more adhesive failures compared to the CTR+Etch+Water (p = 0.047). CONCLUSIONS: While phosphoric acid etch seems to restore the initial composite bond strength to SDF-treated enamel, the long-term success of composite restorations bonded to SDF-treated enamel may need further investigation.

2.
J Clin Med ; 11(17)2022 Aug 24.
Artigo em Inglês | MEDLINE | ID: mdl-36078888

RESUMO

Although inodilators (dobutamine and milrinone) are widely used empirically for cardiogenic shock (CS), the efficacy of inodilators for patients with CS undergoing veno-arterial extracorporeal membrane oxygenation (VA-ECMO) is controversial. We evaluated the effects of inodilators on clinical outcomes using the RESCUE (REtrospective and prospective observational Study to investigate Clinical oUtcomes and Efficacy of left ventricular assist device for Korean patients with cardiogenic shock; NCT02985008) registry. We selected and analyzed the clinical outcomes of 496 patients who underwent VA-ECMO and did or did not receive inodilators. Of the 496 patients, 257 (51.8%) died during hospitalization. We selected 191 matched pairs to adjust for baseline clinical characteristics after 1:1 propensity score matching (PSM). The univariate and multivariate analyses showed that the inodilator group had significantly lower in-hospital mortality than the no-inodilator group (unadjusted hazard ratio [HR], 0.768; 95% confidence interval [CI], 0.579-1.018; p = 0.066, adjusted HR, 0.702; 95% CI, 0.552-0.944; p = 0.019). For patients with CS undergoing VA-ECMO, inodilators may improve clinical outcomes.

4.
Polymers (Basel) ; 14(13)2022 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-35808710

RESUMO

This in vitro study aimed to examine the shear bond strength of composite on the dentin and enamel substrates when mixed with different composite-handling agents (CHAs). Eighty extracted molars were embedded into acrylic resin and sectioned sagittally. On the prepared specimens, four groups of resin mixtures were bonded onto the enamel or dentin surfaces­composite only, composite mixed with Composite Wetting Resin (CWR), composite mixed with Brush and Sculpt (BS), and composite mixed with Modeling Resin (MR). All groups were prepared by mixing at a 1:1 ratio by weight. Each specimen was subjected to the shear bond strength test. After the test, adhesive or cohesive failures were examined at the fractured sites. Data were analyzed using one-way and two-way analysis of variance (ANOVA) and the Tukey post hoc test. All composite groups mixed with CHAs displayed a reduced shear bond strength on dentin and enamel substrates compared to composite alone (p < 0.05). The shear bond strength on dentin decreased in the following order: CWR > BS > MR. A similar pattern was observed on enamel, except that there was no statistically significant difference between BS and MR. Statistically significant interactions between resin mixtures and substrates were found (p < 0.001). On the dentin substrate, adhesive failure dominated while adhesive/cohesive failure dominated on the enamel substrate. Conclusions: The shear bonding strength of composite decreases when mixed with CHAs on both dentin and enamel substrates.

5.
Life (Basel) ; 12(6)2022 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-35743878

RESUMO

Epoxy resin-based sealers are commonly used for successful endodontic treatment. This study aimed to evaluate the cytotoxicity and genotoxicity of epoxy resin-based sealers under unset and set conditions. Three epoxy resin-based sealers were used: Adseal, AH Plus, and Dia-Proseal. To test cytotoxicity, an agar overlay test and a 3-[4,5-dimethylthiazol-2-yl]-2,5 diphenyl tetrazolium bromide (MTT) assay were performed using unset and set sealers on L929 mouse fibroblasts. The genotoxicity test of the comet assay was performed using the same cell line. Extract dilutions in the culture media were used as test materials for the MTT and comet assays. The comet tail produced by the damaged DNA was calculated by image analyses. Statistical analyses were performed using one-way analysis of variance and Tukey's post hoc test. Unset sealers did not show defined decolorized areas. Hardened specimens of resin-based sealers showed circular discolored zones in the agar overlay test. Dia-Proseal was the least cytotoxic after hardening. These results were confirmed in the MTT assay. Cell viability was significantly higher in cells treated with hardened sealers in both groups than that in cells treated with freshly mixed sealers in the MTT assay. Unset AH Plus® and Dia-Proseal™ significantly increased cell viability with decreasing dilution. Adseal™ was the least cytotoxic. Freshly mixed Adseal™ was more genotoxic when freshly mixed than when set. Unset epoxy resin-based sealers were generally more cytotoxic and genotoxic than set materials. Cytotoxicity does not always match the genotoxicity results; therefore, various test tools are required to test toxicity. It is necessary to properly evaluate the toxic effects to establish a biocompatibility test that mimics clinical conditions.

6.
Polymers (Basel) ; 14(12)2022 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-35745892

RESUMO

The development of direct pulp-capping materials with favorable biological and structural properties is an important goal in restorative dentistry. Fucoidan is a sulfated, fucose-containing polysaccharide obtained from brown seaweed, with a wide range of applications; however, its use as a direct pulp-capping material has not been examined. This study aimed to evaluate the mechanical, physical, and biological effects of fucoidan combined with conventional mineral trioxide aggregate (MTA) for direct pulp capping. The capping materials were created using Portland cement (80 wt%) and zirconium oxide (20 wt%) as base components, compared with base components plus 5 wt% fucoidan (PZF5) and base components plus 10 wt% fucoidan (PZF10). The initial and final setting time, compressive strength, chemical components, cell viability, adhesion, migration, osteogenesis, and gene expression were analyzed. Fucoidan significantly reduced the initial and final setting time, regardless of quantity. However, the compressive strength was lower for PZF5. Sulfur levels increased with fucoidan. The biological activity improved, especially in the PZF5 group. Cell migration, Alizarin Red S staining, and alkaline phosphatase activity were upregulated in the PZF5 group. Fucoidan is a useful regenerative additive for conventional pulp-capping materials because it reduces the setting time and improves cell migration and osteogenic ability.

7.
Materials (Basel) ; 15(9)2022 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-35591424

RESUMO

The tensile bond strength between zirconia subjected to different surface-pretreatment methods and methacryloyloxydecyl-dihydrogen-phosphate (MDP)-containing self-adhesive resin cement was evaluated herein. Eighty-eight cylindrical zirconia specimens were randomly divided into the following four groups based on the pretreatment method: (1) no treatment, (2) air abrasion, (3) HNO3/HF etching, and (4) zirconia-nanoparticle coating. The tensile bond strength of the zirconia−resin-cement complexes was investigated. One-way ANOVA and post hoc tests were performed at a 95% significance level, and the Weibull modulus was calculated. Fracture patterns were visualized by SEM. The surface roughness of the specimens without resin bonding was evaluated by AFM. The tensile bond strength of the specimens decreased as follows: Groups 3 > 4 > 2 > 1 (28.2 ± 6.6, 26.1 ± 5.7, 16.6 ± 3.3, and 13.9 ± 3.0 MPa, respectively). Groups 3 and 4 had significantly higher tensile bond strengths (p < 0.05) and lower fracture probabilities than those of Groups 1 and 2. They also showed both mixed failure and resin-cement cohesive failure, whereas Groups 1 and 2 showed mixed failure exclusively. The zirconia−resin tensile bond was stronger after HNO3/HF etching or ZrO2-nanoparticle coating than after air abrasion or no treatment. The estimated surface roughness decreased as follows: Groups 3 > 4 > 2 > 1. The combination of zirconia pretreated with HNO3/HF etching or ZrO2-nanoparticle coating and an MDP-containing self-adhesive resin cement can increase the clinical longevity of zirconia restorations by preventing their decementation.

8.
ESC Heart Fail ; 8(4): 3308-3315, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34145983

RESUMO

AIMS: This study aimed to investigate differences in baseline and treatment characteristics, and in-hospital mortality according to the aetiologies of cardiogenic shock in patients undergoing veno-arterial-extracorporeal membrane oxygenation (VA-ECMO). METHODS AND RESULTS: The RESCUE registry is a multicentre, observational cohort that includes 1247 patients with cardiogenic shock from 12 centres. A total of 496 patients requiring VA-ECMO were finally selected, and the study population was stratified by cardiogenic shock aetiology [ischaemic cardiomyopathy (ICM, n = 342) and non-ICM (NICM, n = 154)]. The primary outcome of interest was in-hospital mortality. Sensitivity analyses including propensity-score matching adjustments were performed. Mean age of the entire population was 61.8 ± 14.2, and 30.8% were women. There were significant differences in baseline characteristics; notable differences included the older age of patients with ICM (65.1 ± 13.7 vs. 58.2 ± 13.8, P < 0.001), preponderance of males [258 (75.4%) vs. 85 (55.2%), P < 0.001], and higher prevalence of diabetes mellitus [140 (40.9%) vs. 39 (25.3%), P = 0.001] compared with patients in the NICM aetiology group. Patients with ischaemic cardiogenic shock were more likely to have longer shock duration before VA-ECMO implantation (518.7 ± 941.4 min vs. 292.4 ± 707.8 min, P = 0.003) and were less likely to undergo distal limb perfusion than those with NICM [108 (31.6%) vs. 79 (51.3%), P < 0.001]. In-hospital mortality in the overall cohort was 52.2%; patients with ICM had a higher unadjusted risk of in-hospital mortality [203 (59.4%) vs. 56 (36.4%); unadjusted hazard ratio, 2.295; 95% confidence interval, 1.698-3.100; P < 0.001]. There were no significant differences in the primary outcome between the two aetiologies following propensity-score matching multiple adjustments (adjusted hazard ratio, 1.265; 95% confidence interval, 0.840-1.906; P = 0.260). CONCLUSIONS: Results of the current study indicated among patients with cardiogenic shock undergoing VA-ECMO, ischaemic aetiology does not seem to impact in-hospital mortality. These findings underline that early initiation and appropriate treatment strategies of VA-ECMO for patients with ICM shock are required.


Assuntos
Cardiomiopatias , Oxigenação por Membrana Extracorpórea , Idoso , Cardiomiopatias/complicações , Cardiomiopatias/epidemiologia , Cardiomiopatias/terapia , Feminino , Mortalidade Hospitalar , Hospitais , Humanos , Masculino , Choque Cardiogênico/epidemiologia , Choque Cardiogênico/etiologia , Choque Cardiogênico/terapia
9.
Heart Vessels ; 36(12): 1848-1855, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34021384

RESUMO

There is currently an ongoing debate about the 'grey area' of heart failure with mid-range ejection fraction (HFmrEF). We evaluated characteristics, prognosis, and the effect of ß-blockers on clinical outcomes in patients with HFmrEF after acute myocardial infarction (AMI). We included a total of 10,785 patients and divided them into three groups: EF 40-49% (HFmrEF; n = 2717; reference); EF < 40% (reduced EF [HFrEF]; n = 1194); and EF ≥ 50% (preserved EF [HFpEF]; n = 6874). The primary outcome was 2-year all-cause mortality. HFmrEF was intermediate between HFrEF and HFpEF for baseline characteristics. The risk of all-cause mortality was lower for HFmrEF patients compared to HFrEF patients (adjusted hazard ratio [HR] 0.710; 95% confidence interval [CI] 0.544-0.927; P = 0.012). However, HFmrEF patients tended to be at higher risk for 2-year all-cause mortality than HFpEF patients (adjusted HR 1.235; 95% CI 0.989-1.511; P = 0.090). ß-blockers were associated with reductions in all-cause mortality for the entire cohort (adjusted HR 0.760; 95% CI 0.592-0.975; P = 0.031). ß-blockers were effective in patients with HFrEF (adjusted HR 0.667; 95% CI 0.471-0.944; P = 0.022), tended to be effective in patients with HFmrEF (adjusted HR 0.665; 95% CI 0.426-1.038; P = 0.072), but not effective in patients with HFpEF (adjusted HR 0.852; 95% CI 0.548-1.326; P = 0.478; interaction P = 0.026). In conclusion, clinical profiles and prognosis of patients with post-AMI HFmrEF are largely intermediate between HFrEF and HFpEF. ß-blockers reduced or tended to reduce 2-year all-cause mortality in patients with HFrEF or HFmrEF, respectively, but not those with HFpEF after AMI.


Assuntos
Insuficiência Cardíaca , Infarto do Miocárdio , Insuficiência Cardíaca/tratamento farmacológico , Hospitalização , Humanos , Infarto do Miocárdio/tratamento farmacológico , Prognóstico , Sistema de Registros , Fatores de Risco , Volume Sistólico
10.
Int J Prosthodont ; 33(6): 629-633, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33284904

RESUMO

PURPOSE: To assess the effect of extraoral polishing of the crown-abutment interface on the marginal fit of implant-supported screw- and cement-retained prostheses (SCRPs). MATERIALS AND METHODS: In 31 patients, the marginal gap of an SCRP was measured using a stereomicroscope before and after polishing of the crown-abutment interface, and the paired data were compared. RESULTS: The marginal gap was significantly decreased after surface polishing regardless of the prosthesis material (P < .001). CONCLUSION: Extraoral polishing of the crown-abutment interface could improve the marginal fit of SCRPs.


Assuntos
Cimentação , Prótese Dentária Fixada por Implante , Parafusos Ósseos , Coroas , Humanos , Projetos Piloto
11.
Chonnam Med J ; 56(1): 36-43, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32021840

RESUMO

We evaluated whether thrombus aspiration (TA) during primary percutaneous coronary intervention (PCI) reduces adverse clinical outcomes within 30-days and 1-year periods. There is no well-designed, Korean data about the clinical impact of intracoronary TA during primary PCI in patients with ST-segment elevation myocardial infarction (STEMI). From the Korea Acute Myocardial Infarction Registry-National Institute of Health, 3749 patients with STEMI undergoing primary PCI within 12 hours (60.8±12.9 years, 18.7% women) with pre-procedural Thrombolysis in Myocardial Infarction (TIMI) flow 0, 1 in coronary angiography were enrolled between November 2011 and December 2015. The patients were divided into two groups: PCI with TA (n=1630) and PCI alone (n=2119). The primary end-point was major adverse cardiac event (MACE), defined as the composite of cardiovascular death (CVD), recurrent MI and stroke for 30-days and 1-year. TA did not diminish the risk of MACE, all-cause mortality and CVD in all patients during 30-days or 1-year. After performing the propensity score matching, TA also did not reduce the risk of MACE (Hazard ratio (HR) with 95% Confidence Interval (CI):1.187 [0.863-1.633], p value=0.291), all-cause mortality (HR with 95% CI: 1.130 [0.776-1.647], p value=0.523) and CVD (HR with 95% CI: 1.222 [0.778-1.920], p value=0.384) during the 1-year period. In subgroup analysis, there was no benefit of clinical outcomes favoring PCI with TA. In conclusion, primary PCI with TA did not reduce MACE, all-cause mortality or CVD among the Korean patients with STEMI and pre-procedural TIMI flow 0, 1 during the 30-day and 1-year follow ups.

12.
J Adv Prosthodont ; 11(5): 280-285, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31754418

RESUMO

PURPOSE: The present study was designed to examine the clinical fit of fixed dental prosthesis fabricated by the milling-sintering method using a presintered cobalt-chromium alloy. MATERIALS AND METHODS: Two single metal-ceramic crowns were fabricated via milling-sintering method and casting method in each of the twelve consecutive patients who required an implant-supported fixed prosthesis. In the milling-sintering method, the prosthetic coping was designed in computer software, and the design was converted to a non-precious alloy coping using milling and post-sintering process. In the casting method, the conventional manual fabrication process was applied. The absolute marginal discrepancy of the prostheses was evaluated intraorally using the triple-scan technique. Statistical analysis was conducted using Mann-Whitney U test (α=.05). RESULTS: Eight patients (66.7%) showed a lower marginal discrepancy of the prostheses made using the milling-sintering method than that of the prosthesis made by the casting method. Statistically, the misfit of the prosthesis fabricated using the milling-sintering method was not significantly different from that fabricated using the casting method (P=.782). There was no tendency between the amount of marginal discrepancy and the measurement point. CONCLUSION: The overall marginal fit of prosthesis fabricated by milling-sintering using a presintered alloy was comparable to that of the prosthesis fabricated by the conventional casting method in clinical use.

13.
Korean Circ J ; 48(3): 217-226, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29557108

RESUMO

BACKGROUND AND OBJECTIVES: Neurologic intolerance (NI) is defined as the occurrence of neurological symptoms during carotid artery stenting (CAS). Because NI is inevitable problem, it may be helpful to anticipate its occurrence. So, we studied factors associated with NI during proximal protected CAS. METHODS: We retrospectively analyzed all consecutive patients underwent proximal protected CAS from August 2012 to January 2017. RESULTS: We included total 123 patients (109 males, 72±8 years old). The total procedure time was 43±12 minutes, and mean occlusion time was 4.8±1.2 minutes. We divided CAS patients into 2 groups according to presence of NI; neurologic tolerance (NT; n=74, 60%) and NI (n=49, 40%) groups. After the univariate analysis, symptomatic carotid artery stenosis (p=0.003), absence of anterior communicating artery (p=0.015) and low common carotid artery occlusion pressure (CCAOP, p<0.001) were associated with NI. After the multivariate analysis, NI was significantly associated with symptomatic carotid artery stenosis (odds ratio [OR], 5.549; p=0.014) and systolic CCAOP≤42 mmHg (OR, 6.461; p<0.001). In NI group, 43 patients (88%) recovered right after the balloon deflation and 2 patients were normalized within 2 hours. However, 1 had major stroke and 3 had minor strokes in 4 patients with persistent NI ≥24 hours. CONCLUSIONS: About 40% showed NI during the CAS. Most of them (88%, 43 of 49 patients) recovered after the balloon deflation, but stroke incidence was significantly higher in NI group. Symptomatic carotid artery stenosis and systolic CCAOP ≤42 mmHg were significantly associated with the development of NI during proximal protected CAS.

14.
Materials (Basel) ; 10(3)2017 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-28772647

RESUMO

Dental light-cured resins can undergo different degrees of polymerization when applied in vivo. When polymerization is incomplete, toxic monomers may be released into the oral cavity. The present study assessed the cytotoxicity of different materials, using sample preparation methods that mirror clinical conditions. Composite and bonding resins were used and divided into four groups according to sample preparation method: uncured; directly cured samples, which were cured after being placed on solidified agar; post-cured samples were polymerized before being placed on agar; and "removed unreacted layer" samples had their oxygen-inhibition layer removed after polymerization. Cytotoxicity was evaluated using an agar diffusion test, MTT assay, and confocal microscopy. Uncured samples were the most cytotoxic, while removed unreacted layer samples were the least cytotoxic (p < 0.05). In the MTT assay, cell viability increased significantly in every group as the concentration of the extracts decreased (p < 0.05). Extracts from post-cured and removed unreacted layer samples of bonding resin were less toxic than post-cured and removed unreacted layer samples of composite resin. Removal of the oxygen-inhibition layer resulted in the lowest cytotoxicity. Clinicians should remove unreacted monomers on the resin surface immediately after restoring teeth with light-curing resin to improve the restoration biocompatibility.

15.
Blood Press ; 26(4): 204-210, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28142262

RESUMO

BACKGROUND: Although brachial-ankle pulse wave velocity (baPWV) is well-known for predicting the cardiovascular mortality and morbidity, its anticipated value is not demonstrated well concerning acute stroke. METHODS: Total 1557 patients with acute stroke who performed baPWV were enrolled. We evaluated the prognostic value of baPWV predicting all-cause death and vascular death in patients with acute stroke Results: Highest quartile of baPWV was ≥23.64 m/s. All-caused deaths (including vascular death; 71) were 109 patients during follow-up periods (median 905 days). Multivariate Cox regression analysis revealed that patients with the highest quartile of baPWV had higher risk for vascular death when they are compared with patients with all other three quartiles of baPWV (Hazard ratio with 95% confidence interval [CI] 1.879 [1.022-3.456], p = .042 for vascular death). CONCLUSION: High baPWV was a strong prognostic value of vascular death in patients with acute stroke.


Assuntos
Índice Tornozelo-Braço/métodos , Análise de Onda de Pulso/métodos , Acidente Vascular Cerebral/diagnóstico , Idoso , Feminino , Humanos , Masculino , Prognóstico , Acidente Vascular Cerebral/mortalidade
16.
J Korean Med Sci ; 32(2): 272-277, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28049238

RESUMO

Obesity and metabolic syndrome is a worldwide pandemic and associated with high cardiovascular risk. Metabolic endotoxemia (ME) is thought to be an underlying molecular mechanism. It triggers toll-like receptor 4-mediated inflammatory adipokines and causes a chronic low grade inflammatory status, which results in cardiovascular risk increase. Exercise is the best nonpharmacological treatment to improve prognosis. In this study, we examined the circulating endotoxin level in Korean obese women and investigated effects of exercise on it. Women over body mass index (BMI) 25 kg/m² participated in a resistance training exercise, Curves. At baseline and after 12 weeks exercise, tests including blood samples were taken. In Korean obese women, the fasting endotoxin was 1.45 ± 0.11 EU/mL. Ingestion of a high calorie meal led to a peak level after 2 hours (postprandial 2 hours [PP2]) and a significant rise over the 4 hours (postprandial 4 hours [PP4]) in it (1.78 ± 0.15 and 1.75 ± 0.14 EU/mL for PP2 and PP4, P < 0.05 vs. fasting). After exercise, BMI and hip circumference were reduced significantly. The total cholesterol (TC) at fasting, PP2 and PP4 were decreased significantly. All levels of circulating endotoxin at fasting, PP2 and PP4 showed reduction. But, the peak change was only significant (baseline vs. 12 weeks for PP2; 1.78 ± 0.15 vs. 1.48 ± 0.06 EU/mL, P < 0.05). We report the circulating endotoxin level in Korean obese women for the first time. Also, we establish that energy intake leads to endotoxemia and exercise suppresses the peak endotoxemia after meal. It suggests an impact for a better prognosis in obese women who follow regular exercise.


Assuntos
Endotoxemia/diagnóstico , Exercício Físico , Obesidade/diagnóstico , Adulto , Povo Asiático , Glicemia/análise , Índice de Massa Corporal , HDL-Colesterol/sangue , LDL-Colesterol/sangue , Endotoxemia/complicações , Endotoxinas/sangue , Ingestão de Energia , Feminino , Humanos , Pessoa de Meia-Idade , Obesidade/complicações , Prognóstico , República da Coreia , Fatores de Risco , Triglicerídeos/sangue , Circunferência da Cintura , Adulto Jovem
17.
Clin Interv Aging ; 11: 927-31, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27462148

RESUMO

Ventricular septal defect (VSD) is a lethal complication of myocardial infarction. The event occurs 2-8 days after an infarction and patients should undergo emergency surgical treatment. We report on successful device closure of post-infarction VSD. A previously healthy 66-year-old male was admitted with aggravated dyspnea. Echocardiography showed moderate left ventricular (LV) systolic dysfunction with akinesia of the left anterior descending (LAD) territory and muscular VSD size approximately 2 cm. Coronary angiography showed mid-LAD total occlusion without collaterals. Without percutaneous coronary intervention due to time delay, VSD repair was performed. However, a murmur was heard again and pulmonary edema was not controlled 3 days after the operation. Echocardiography showed remnant VSD, and medical treatment failed. Percutaneous treatment using a septal occluder device was decided on. After the procedure, heart failure was controlled and the patient was discharged without complications. This is the first report on device closure of post-infarction VSD in Korea.


Assuntos
Comunicação Interventricular/cirurgia , Infarto do Miocárdio/patologia , Dispositivo para Oclusão Septal , Idoso , Comunicação Interventricular/etiologia , Humanos , Masculino
18.
Int J Nanomedicine ; 11: 2557-67, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27354790

RESUMO

Therapeutically relevant design of scaffolds is of special importance in the repair and regeneration of tissues including dentin and pulp. Here we exploit nanofiber matrices that incorporate bioactive glass nanoparticles (BGNs) and deliver the odontogenic drug dexamethasone (DEX) to stimulate the odontogenic differentiation of human dental pulp cells (HDPCs). DEX molecules were first loaded onto the BGN, and then the DEX-BGN complex was incorporated within the biopolymer nanofiber matrix through electrospinning. The release of DEX continued over a month, showing a slow releasing profile. HDPCs cultured on the DEX-releasing BGN matrices were viable, proliferating well up to 14 days. The odontogenic differentiation, as assessed by alkaline phosphatase activity, mRNA expression of genes, and mineralization, was significantly stimulated on the matrices incorporating BGN and further on those releasing DEX. The DEX-releasing BGN matrices highly upregulated the expression of the integrin subsets α1, α5, and ß3 as well as integrin downstream signaling molecules, including focal adhesion kinase (FAK), Paxillin, and RhoA, and activated bone morphogenetic protein mRNA and phosphorylation of Smad1/5/8. Furthermore, the DEX-releasing BGN-matrices stimulated Akt and mammalian target of rapamycin (mTOR), which was proven by the inhibition study. Collectively, the designed therapeutic nanofiber matrices that incorporate BGN and deliver DEX were demonstrated to promote odontogenesis of HDPCs, and the integrins, bone morphogenetic protein, and mTOR signaling pathways are proposed to be the possible molecular mechanisms. While further in vivo studies are still needed, the DEX-releasing bioactive scaffolds are considered as a potential therapeutic nanomatrix for regenerative endodontics and tissue engineering.


Assuntos
Polpa Dentária/efeitos dos fármacos , Dexametasona/administração & dosagem , Sistemas de Liberação de Medicamentos/métodos , Nanofibras/química , Odontogênese/efeitos dos fármacos , Proteínas Morfogenéticas Ósseas/metabolismo , Diferenciação Celular/efeitos dos fármacos , Células Cultivadas , Polpa Dentária/citologia , Polpa Dentária/metabolismo , Dexametasona/farmacologia , Vidro , Humanos , Integrinas/metabolismo , Nanofibras/administração & dosagem , Nanopartículas/química , Transdução de Sinais/efeitos dos fármacos , Serina-Treonina Quinases TOR/metabolismo , Engenharia Tecidual/métodos
19.
Int J Cardiol ; 218: 75-78, 2016 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-27232915

RESUMO

BACKGROUND: Coronary spasm is the major pathophysiology of vasospastic angina (VA). Medical treatment is usually effective in VA patients without significant stenosis. However, there is little information about the percutaneous coronary intervention (PCI) in VA patients with significant coronary artery stenosis (CAS). METHODS: After retrospective screening of all consecutive VA patients from January 2010 to April 2015, we selected significant CAS (>50% of diameter stenosis) after nitrate injection and divided them into two groups according to the presence of PCI. RESULTS: A total of 220 VA patients (41 females, mean age: 58±10years old) were screened, and 85 were included in this study. Males were predominant in the VA with significant CAS group (89 vs 76%, p=0.020). PCI was done in 43 patients (51%). The most common culprit coronary artery was the left anterior descending coronary artery (18, 42%), diameter stenosis was significantly higher (66±9 vs 61±10%, p<0.01), and total number of antianginal medication was significantly lower in the PCI group than in the medical group (1.7±0.9 vs 2.1±0.8, p=0.039). Moreover, 4 patients underwent PCI to control symptoms in the medical treatment group during the follow-up period (26±13months). However, additional antiplatelet therapy was necessary in patients with coronary angioplasty, and there were 2 cases with complication associated with angioplasty (1 restenosis and 1 bleeding complication). CONCLUSION: In VA patients with significant CAS, both treatment modalities showed similar clinical outcomes. Although the PCI can afford symptomatic improvement, it needed additional antiplatelet medications and can be associated with procedural complications.


Assuntos
Angina Instável/cirurgia , Estenose Coronária/cirurgia , Vasoespasmo Coronário/cirurgia , Intervenção Coronária Percutânea/tendências , Idoso , Angina Instável/diagnóstico por imagem , Angina Instável/epidemiologia , Angiografia Coronária/tendências , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/epidemiologia , Vasoespasmo Coronário/diagnóstico por imagem , Vasoespasmo Coronário/epidemiologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
20.
Biomaterials ; 85: 88-98, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26854394

RESUMO

Magnetism has recently been implicated to play significant roles in the regulation of cell responses. Allowing cells to experience a magnetic field applied externally or scaffolding them in a material with intrinsic magnetic properties has been a possible way of utilizing magnetism. Here we aim to investigate the combined effects of the external static magnetic field (SMF) with magnetic nanocomposite scaffold made of polycaprolactone/magnetic nanoparticles on the osteoblastic functions and bone formation. The SMF synergized with the magnetic scaffolds in the osteoblastic differentiation of primary mouse calvarium osteoblasts, including the expression of bone-associated genes (Runx2 and Osterix) and alkaline phosphatase activity. The synergism was demonstrated in the activation of integrin signaling pathways, such as focal adhesion kinase, paxillin, RhoA, mitogen-activated protein kinase, and nuclear factor-kappaB, as well as in the up-regulation of bone morphogenetic protein-2 and phosphorylation of Smad1/5/8. Furthermore, the SMF/magnetic scaffold-stimulated osteoblasts promoted the angiogenic responses of endothelial cells, including the expression of vascular endothelial growth factor and angiogenin-1 genes and the formation of capillary tubes. When the magnetic scaffolds were implanted in mouse calvarium defects, the application of SMF significantly enhanced the new bone formation at 6 weeks, as revealed by the histological and micro-computed tomographic analyses. Current findings suggest that the combinatory application of external (SMF) and internal (scaffold) magnetism can be a promising tool to regenerative engineering of bone.


Assuntos
Diferenciação Celular/efeitos dos fármacos , Campos Magnéticos , Nanocompostos/química , Osteoblastos/efeitos dos fármacos , Osteogênese/efeitos dos fármacos , Alicerces Teciduais/química , Animais , Feminino , Quinase 1 de Adesão Focal/genética , Quinase 1 de Adesão Focal/metabolismo , Integrinas/genética , Integrinas/metabolismo , Camundongos , Camundongos Endogâmicos ICR , Proteínas Quinases Ativadas por Mitógeno/genética , Proteínas Quinases Ativadas por Mitógeno/metabolismo , NF-kappa B/genética , NF-kappa B/metabolismo , Osteoblastos/citologia , Paxilina/genética , Paxilina/metabolismo , Poliésteres/química , Ribonuclease Pancreático/genética , Ribonuclease Pancreático/metabolismo , Transdução de Sinais , Engenharia Tecidual , Regulação para Cima , Proteínas rho de Ligação ao GTP/genética , Proteínas rho de Ligação ao GTP/metabolismo , Proteína rhoA de Ligação ao GTP
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...