Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 164
Filtrar
1.
ACS Energy Lett ; 9(5): 2212-2221, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38751969

RESUMO

Owing to their high-voltage stabilities, halide superionic conductors such as Li3YCl6 recently emerged as promising solid electrolyte (SE) materials for all-solid-state batteries (ASSBs). It has been shown that by either introducing off-stoichiometry in solid-state (SS) synthesis or using a mechanochemical (MC) synthesis method the ionic conductivities of Li3-3xY1+xCl6 can increase up to an order of magnitude. The underlying mechanism, however, is unclear. In the present study, we adopt a hopping frequency analysis method of impedance spectra to reveal the correlations in stoichiometry, crystal structure, synthesis conditions, Li+ carrier concentrations, hopping migration barriers, and ionic conductivity. We show that unlike the conventional Li3YCl6 made by SS synthesis, mobile Li+ carriers in the defect-containing SS-Li3-3xY1+xCl6 (0 < x < 0.17) and MC-Li3-3xY1+xCl6 are generated with an activation energy and their concentration is dependent on temperature. Higher ionic conductivities in these samples arise from a combination of a higher Li+ carrier concentration and lower migration energy barriers. A new off-stoichiometric halide (Li2.61Y1.13Cl6) with the highest ionic conductivity (0.47 mS cm-1) in the series is discovered, which delivers exceptional cycling performance (∼90% capacity retention after 1000 cycles) in ASSB cells equipped with an uncoated high-energy LiNi0.8Mn0.1Co0.1O2 (NMC811) cathode. This work sheds light on the thermal activation process that releases trapped Li+ ions in defect-containing halides and provides guidance for the future development of superionic conductors for all-solid-state batteries.

2.
Sci Rep ; 14(1): 8504, 2024 04 12.
Artigo em Inglês | MEDLINE | ID: mdl-38605094

RESUMO

This work aims to investigate the clinical feasibility of deep learning-based synthetic CT images for cervix cancer, comparing them to MR for calculating attenuation (MRCAT). Patient cohort with 50 pairs of T2-weighted MR and CT images from cervical cancer patients was split into 40 for training and 10 for testing phases. We conducted deformable image registration and Nyul intensity normalization for MR images to maximize the similarity between MR and CT images as a preprocessing step. The processed images were plugged into a deep learning model, generative adversarial network. To prove clinical feasibility, we assessed the accuracy of synthetic CT images in image similarity using structural similarity (SSIM) and mean-absolute-error (MAE) and dosimetry similarity using gamma passing rate (GPR). Dose calculation was performed on the true and synthetic CT images with a commercial Monte Carlo algorithm. Synthetic CT images generated by deep learning outperformed MRCAT images in image similarity by 1.5% in SSIM, and 18.5 HU in MAE. In dosimetry, the DL-based synthetic CT images achieved 98.71% and 96.39% in the GPR at 1% and 1 mm criterion with 10% and 60% cut-off values of the prescription dose, which were 0.9% and 5.1% greater GPRs over MRCAT images.


Assuntos
Aprendizado Profundo , Neoplasias do Colo do Útero , Feminino , Humanos , Neoplasias do Colo do Útero/diagnóstico por imagem , Estudos de Viabilidade , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X/métodos , Planejamento da Radioterapia Assistida por Computador/métodos
3.
J Oleo Sci ; 73(4): 455-466, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38556280

RESUMO

In this study, the phospholipid species [i.e., phosphatidylethanolamine (PE), phosphatidylcholine (PC), and sphingomyelin (SM)] in human milk (HM) were compared according to their fatty acid (FA) composition. 34 HM samples were collected and classified into three groups (A < B < C) according to their fat content. Stearic acid (C18:0) was the main FA in PE, PC, and SM. The highest concentrations of arachidonic acid (AA), eicosapentaenoic acid (EPA), and docosapentaenoic acid (DPA) were observed in PE, whereas docosahexaenoic acid (DHA) was predominant in SM. Although PC exhibited the highest total saturated FAs (SFAs) and PE contained the highest unsaturated FAs (UFAs), very long-chain SFAs and monounsaturated FAs (MUFAs) were preferentially distributed in SM. PC and SM had higher saturation compared to PE. Regarding the effect of the fat content of HM on the FA composition of the phospholipid species, a limited influence was observed on the composition of SFAs and MUFAs of PE, SM, and particularly PC. However, a more pronounced effect on the composition of polyunsaturated FAs (PUFAs) in phospholipids was observed, especially for linoleic acid (LA), α-linolenic acid (ALA), EPA, and DHA, indicating that the composition of FAs in the phospholipid species was probably affected by the maternal diet.


Assuntos
Ácidos Graxos , Fosfolipídeos , Humanos , Leite Humano , Ácido Linoleico , Ácidos Docosa-Hexaenoicos , Ácido Eicosapentaenoico , Fosfatidilcolinas , República da Coreia
4.
Healthcare (Basel) ; 12(3)2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38338257

RESUMO

In the current healthcare landscape, nurses frequently encounter various ethical dilemmas, necessitating situation-specific ethical judgments. It is crucial to thoroughly understand the factors that shape the hospital ethical climate and the elements that are influenced by this climate. This study aims to identify the variables associated with the hospital ethical climate perceived by Korean nurses. A literature search was conducted using the core database, and the effect sizes of relevant variables were analyzed using a comprehensive meta-analysis. The overall effect size analysis incorporated 56 variables, and a meta-analysis was performed on 7 variables. This study found correlations between ethical sensitivity (ESr = 0.48), moral distress (ESr = -0.30), empathy (ESr = 0.27), ethical leadership (ESr = 0.72), job satisfaction (ESr = 0.64), and intention to leave (ESr = -0.34) with the hospital ethical climate. Both personal and organizational attributes were moderately related to the hospital ethical climate. Enhancing the hospital ethical climate could positively affect both individuals and the organization. The protocol for this study has been registered with PROSPERO (CRD42022379812).

5.
BMJ Open ; 14(1): e078102, 2024 01 22.
Artigo em Inglês | MEDLINE | ID: mdl-38262648

RESUMO

INTRODUCTION: The hospital ethical climate refers to the ethical work environment within a hospital, which may positively or negatively impact individual nurses, nursing organisations and patient care. Most of studies investigating the hospital ethical climate among Korean nurses have been published in Korean. However, papers addressing the hospital ethical climate in Korean were excluded from the systematic review. To enhance our comprehension of the hospital ethical climate, a systematic review specifically focusing on Korean nurses is imperative. Additionally, it is crucial to ascertain the factors associated with the hospital ethical climate and their respective effect sizes through meta-analyses. METHODS AND ANALYSIS: The systematic search will be conducted for papers published in both Korean and English, encompassing the hospital ethics climate of Korean nurses from 10 database inception to May 2023. Two reviewers will independently review each article based on the inclusion and exclusion criteria, and any differences in opinion will be resolved through discussion and consensus. The study selection process will be reported using the Preferred Reporting Items for Systematic Reviews and Meta-Analyses flow diagram. Quality assessment will be conducted using the Checklist for Analytical Cross-Sectional Studies provided by Joanna Briggs Institute. Effect size will be analysed using Comprehensive Meta-Analysis software V.2.0. The results of this study will identify factors related to the hospital ethical climate and the effect size of these factors among nurses in Korea. ETHICS AND DISSEMINATION: Ethical approval is not required, as the data will be collected from existing literature. Findings will be disseminated through peer-reviewed journal. PROSPERO REGISTRATION NUMBER: CRD42022379812.


Assuntos
Hospitais , Humanos , Estudos Transversais , Metanálise como Assunto , República da Coreia , Revisões Sistemáticas como Assunto/métodos , Recursos Humanos de Enfermagem Hospitalar
6.
World J Clin Cases ; 11(31): 7562-7569, 2023 Nov 06.
Artigo em Inglês | MEDLINE | ID: mdl-38078139

RESUMO

BACKGROUND: Various reconstruction options have been introduced to treat decubitus ulcers. A combined flap that takes advantage of the fasciocutaneous and muscle flaps has been proven to be effective in reconstructing decubitus ulcers in previous studies. However, no studies have measured combined flap thickness. This is the first study to demonstrate the superiority of the combined flap by measuring its thickness using enhanced abdominopelvic computed tomography (APCT). AIM: To evaluate combined flap modality as a useful reconstruction option for decubitus ulcers using measurements obtained through APCT. METHODS: Fifteen patients with paraplegia who underwent combined flap surgery for reconstruction of decubitus ulcers between March 2020 and December 2021 were included. The defects in the skin and muscle components were reconstructed separately. The inner gluteus muscle flap was split and manipulated to obliterate dead space. The outer fasciocutaneous flap was transposed to cover the muscle flap and opening of the decubitus ulcer. Subsequently, we performed enhanced APCT at 3 wk and 6 mo postoperatively to measure the flap thickness. RESULTS: The mean flap thickness was 32.85 ± 8.89 mm at 3 wk postoperatively and 29.27 ± 8.22 mm at 6 mo postoperatively. The flap thickness was maintained without any major complications such as contour deformities or recurrence. CONCLUSION: Although there was a significant decrease in flap thickness as measured by APCT, the combined flap provided sufficient padding and maintained its thickness even at 6 mo after reconstruction, suggesting that the combined flap modality may be a useful reconstruction option for patients with paraplegic decubitus ulcers.

7.
ACS Appl Mater Interfaces ; 15(50): 58367-58376, 2023 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-38079499

RESUMO

Halide solid electrolytes (SEs) have been highlighted for their high-voltage stability. Among the halide SEs, the ionic conductivity has been improved by aliovalent metal substitutions or choosing a ccp-like anion-arranged monoclinic structure (C2/m) over hcp- or bcc-like anion-arranged structures. Here, we present a new approach, hard-base substitution, and its underlying mechanism to increase the ionic conductivity of halide SEs. The oxygen substitution to Li2ZrCl6 (trigonal, hcp) increased the ionic conductivity from 0.33 to 1.3 mS cm-1 at Li3.1ZrCl4.9O1.1 (monoclinic, ccp), while the sulfur and fluorine substitutions were not effective. A systematic comparison study revealed that the energetic stabilization of interstitial sites for Li migration plays a key role in improving the ionic conductivity, and the ccp-like anion sublattice is not sufficient to achieve high ionic conductivity. We further examined the feasibility of the oxyhalide SE for practical and all-solid-state battery applications.

8.
World J Clin Cases ; 11(27): 6374-6382, 2023 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-37900224

RESUMO

BACKGROUND: The nasal bone, being the most protruding bone in the center of the facial bones, is particularly susceptible to damage. Nasal bone fractures can often result in secondary deformation and dysfunction of the nose, including septal fractures. Studies on functional or intra-nasal complications have been rarely reported after nasal bone fracture reduction. AIM: To evaluate the severity of nasal obstruction and its improvement following nasal bone fracture reduction using inferior turbinoplasty. METHODS: We conducted a retrospective review of data from 50 patients with symptomatic nasal obstruction between January to December 2010. All patients underwent preoperative Computed tomography evaluation, and symptom changes and nasal cavity volume were analyzed using a visual analog scale and acoustic rhinometry before and after surgery. Closed reduction and out-fracture of both inferior turbinates performed by the same surgeon. Treatment outcomes were assessed by comparing changes in the nasal airway volume measured using acoustic rhinometry before and after surgery. The minimal cross-sectional area (MCA) was also analyzed based on the Stranc classification. RESULTS: Before reduction, the mean MCA for all cases was 0.59 ± 0.06 cm2, which represented an 11% decrease compared to the average size of a Korean adult (0.65 ± 0.03 cm2). The MCA for frontal impact was 0.60 ± 0.02 cm2 and for lateral impact, it was 0.58 ± 0.03 cm2. After reduction via inferior turbinoplasty, the MCA improved to 0.64 ± 0.04 cm2. CONCLUSION: This study suggests that turbinoplasty is helpful in addressing nasal obstruction. Out-fracture of the inferior turbinate is an effective and durable technique that can be easily performed to enlarge the nasal airway with minimal morbidity.

9.
J Med Internet Res ; 25: e48093, 2023 10 20.
Artigo em Inglês | MEDLINE | ID: mdl-37862101

RESUMO

BACKGROUND: With the global rise in Alzheimer disease (AD), early screening for mild cognitive impairment (MCI), which is a preclinical stage of AD, is of paramount importance. Although biomarkers such as cerebrospinal fluid amyloid level and magnetic resonance imaging have been studied, they have limitations, such as high cost and invasiveness. Digital markers to assess cognitive impairment by analyzing behavioral data collected from digital devices in daily life can be a new alternative. In this context, we developed a "virtual kiosk test" for early screening of MCI by analyzing behavioral data collected when using a kiosk in a virtual environment. OBJECTIVE: We aimed to investigate key behavioral features collected from a virtual kiosk test that could distinguish patients with MCI from healthy controls with high statistical significance. Also, we focused on developing a machine learning model capable of early screening of MCI based on these behavioral features. METHODS: A total of 51 participants comprising 20 healthy controls and 31 patients with MCI were recruited by 2 neurologists from a university hospital. The participants performed a virtual kiosk test-developed by our group-where we recorded various behavioral data such as hand and eye movements. Based on these time series data, we computed the following 4 behavioral features: hand movement speed, proportion of fixation duration, time to completion, and the number of errors. To compare these behavioral features between healthy controls and patients with MCI, independent-samples 2-tailed t tests were used. Additionally, we used these behavioral features to train and validate a machine learning model for early screening of patients with MCI from healthy controls. RESULTS: In the virtual kiosk test, all 4 behavioral features showed statistically significant differences between patients with MCI and healthy controls. Compared with healthy controls, patients with MCI had slower hand movement speed (t49=3.45; P=.004), lower proportion of fixation duration (t49=2.69; P=.04), longer time to completion (t49=-3.44; P=.004), and a greater number of errors (t49=-3.77; P=.001). All 4 features were then used to train a support vector machine to distinguish between healthy controls and patients with MCI. Our machine learning model achieved 93.3% accuracy, 100% sensitivity, 83.3% specificity, 90% precision, and 94.7% F1-score. CONCLUSIONS: Our research preliminarily suggests that analyzing hand and eye movements in the virtual kiosk test holds potential as a digital marker for early screening of MCI. In contrast to conventional biomarkers, this digital marker in virtual reality is advantageous as it can collect ecologically valid data at an affordable cost and in a short period (5-15 minutes), making it a suitable means for early screening of MCI. We call for further studies to confirm the reliability and validity of this approach.


Assuntos
Doença de Alzheimer , Disfunção Cognitiva , Realidade Virtual , Humanos , Movimentos Oculares , Reprodutibilidade dos Testes , Disfunção Cognitiva/psicologia , Doença de Alzheimer/patologia , Aprendizado de Máquina , Biomarcadores
10.
Int Wound J ; 2023 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-37818699

RESUMO

The increased peripheral arterial disease (PAD) incidence associated with aging and increased incidence of cardiovascular conditions underscores the significance of assessing lower limb perfusion. This study aims to report on the correlation and utility of two novel non-invasive instruments: transcutaneous oxygen pressure (TcPO2 ) and forward-looking infrared (FLIR) thermography. A total of 68 patients diagnosed with diabetic foot ulcer and PAD who underwent vascular studies at a single institution between March 2022 and March 2023 were included. Cases with revascularization indications were treated by a cardiologist. Following the procedure, ambient TcPO2 and FLIR thermography were recorded on postoperative days 1, 7, 14, 21 and 28. In impaired limbs, TcPO2 was 12.3 ± 2 mmHg and FLIR thermography was 28.7 ± 0.9°C. TcPO2 (p = 0.002), FLIR thermography (p = 0.015) and ankle-brachial index (p = 0.047) values significantly reduced with greater vascular obstruction severity. Revascularization (n = 39) significantly improved TcPO2 (12.5 ± 1.7 to 19.1 ± 2.2 mmHg, p = 0.011) and FLIR (28.8 ± 1.8 to 32.6 ± 1.6°C; p = 0.018), especially in severe impaired angiosomes. TcPO2 significantly increased immediately post-procedure, then gradually, whereas the FLIR thermography values plateaued from day 1 to 28 post-procedure. In conclusion, FLIR thermography is a viable non-invasive tool for evaluating lower limb perfusion based on angiosomes, comparable with TcPO2 .

11.
Pharmaceutics ; 15(8)2023 Aug 10.
Artigo em Inglês | MEDLINE | ID: mdl-37631336

RESUMO

The purpose of this study is to evaluate the changes in physical properties and biocompatibilities caused by thermocycling of CAD/CAM restorative materials (lithium disilicate, zirconia reinforced lithium silicate, polymer-infiltrated ceramic network, resin nanoceramic, highly translucent zirconia). A total of 225 specimens were prepared (12.0 × 10.0 × 1.5 mm) and divided into three groups subjected to water storage at 37 °C for 24 h (control group), 10,000 cycles in distilled water at 5-55 °C (first aged group), and 22,000 cycles in distilled water at 5-55 °C (second aged group) [(n= 15, each]). The nanoindentation hardness and Young's modulus (nanoindenter), surface roughness (atomic force microscopy (AFM)), surface texture (scanning electron microscopy (FE-SEM)), elemental concentration (energy dispersive spectroscopy (EDS)) and contact angle were evaluated. The morphology, proliferation and adhesion of cultured human gingival fibroblasts (HGFs) were analyzed. The data were analyzed using one-way ANOVA and Tukey's test (p < 0.05). The results showed that the nanoindentation hardness and Young's modulus were decreased after thermocycling aging. Cell viability and proliferation of the material decreased with aging except for the highly translucent zirconia. Zirconia-reinforced lithium silicate exhibited significantly lower cell viability compared to other materials. The surface roughnesses of all groups increased with aging. Cell viability and Cell adhesion were influenced by various factors, including the surface chemical composition, hydrophilicity, surface roughness, and topography.

12.
Arch Craniofac Surg ; 24(3): 133-138, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37415471

RESUMO

White-eyed blowout fractures with extraocular muscle (EOM) entrapment necessitate emergency surgical intervention. However, even after surgery, diplopia or EOM motion limitations may persist due to the incomplete reduction of soft tissue herniation caused by inadequate dissection or unresolved muscle strangulation. In this report, we present a case of postoperative EOM movement limitation in a 5-year-old girl who experienced recurrent restriction in the upward gaze of her right eye 14 days after surgery. Instead of revision surgery, the patient was treated with targeted EOM exercises focusing on the inferior rectus muscle and inferior oblique muscle. The patient was instructed to slowly move her pupils from the central point to the upper and outer sides, then in a straight line from the central point to the lower and inner sides before returning to the center point. On the 28th postoperative day, 2 weeks after initiating the exercises, the patient's EOM motion fully recovered. This case highlights the effectiveness of EOM exercises as a non-surgical treatment approach for improving recurrent EOM movement limitations in the absence of soft tissue herniation following surgical management of blowout fractures in children.

14.
Nanoscale ; 15(26): 10990-11004, 2023 Jul 06.
Artigo em Inglês | MEDLINE | ID: mdl-37294178

RESUMO

An innovative approach to fabricate transparent and redispersible α-chitin nanocrystals (ChNCs) with high overall yields was developed in this work for eventual commercial use. The nanomanufacturing process included electron-beam irradiation (EBI) of chitin for oxidation and degradation in the dried state, high-pressure nanoscale homogenization via swelling, CO2 absorption, and spray-drying to obtain dehydrated products. The resulting EBI-disassociated chitins contained increased amounts of carboxylate (0.19-0.27 mmol g-1) and a negligible fraction of D-glucosamine moiety (from ca. 6.5 to <1.0%) with an intrinsic structure identical to α-chitin derived from shrimp shell prior to purification by conventional methods, such as deproteination. The resulting EBI-induced ChNC series exhibited nano-sized and rod-like morphology with tunable lengths averaging 608-259 nm, uniform widths of ca. 16-12 nm, a high isolation yield of max. 81%, and sufficient anionic surface charges, as zeta potentials of -32 to -34 mV indicate that it is homogenously water-dispersible and stable with background transparency. Unlike ChNC prepared by HCl-hydrolysis, the dehydrated particles of EBI-induced ChNCs were clearly redispersible in water and retained the characteristics of the original nanomaterials. We also tested the redispersible EBI-induced ChNCs as effective adsorbents. Their anionic groups interacted with cationic heavy metals (Cu2+ and Fe3+) and organic blue dye via electrostatic attraction, forming robust hydrogels, which were self-supporting after centrifugation. The EBI-induced ChNCs produced with low environmental impact in this work offer a promising choice of adsorbents for the removal of undesirable chemicals during wastewater treatment.

15.
Healthcare (Basel) ; 11(11)2023 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-37297753

RESUMO

This study aims to analyze the concept of nursing surveillance among nurses caring for patients in acute care hospitals in Korea. The conceptual analysis was conducted using the hybrid model proposed by Schwartz-Barcott and Kim. In the theoretical phase, the attributes of nursing surveillance were explored through a literature review. In the fieldwork phase, the attributes of nursing surveillance were derived by analyzing interview materials. In the final analysis phase, nursing surveillance attributes and the related factors were integrated and confirmed. The attributes of nursing surveillance were systematic assessment, pattern recognition, the anticipation of problems, effective communication, decision-making, and performing nursing practice. Based on the theoretical basis of the nursing surveillance concept, this study identified the nursing surveillance concept as perceived by Korean nurses, and examined strategies to promote nursing surveillance.

16.
Microbiol Resour Announc ; 12(7): e0008623, 2023 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-37306582

RESUMO

Here, we report the complete genome sequence of strain NIBR1757, isolated from the water of Lake Chungju in South Korea. The assembled genome consists of 4,185 coding sequences (CDSs), 6 rRNAs, and 51 tRNAs. Comparative 16S rRNA gene sequence studies and GTDB-Tk analysis show that this strain belongs to the genus Caulobacter.

17.
J Korean Acad Nurs ; 53(2): 236-248, 2023 Apr.
Artigo em Coreano | MEDLINE | ID: mdl-37164350

RESUMO

PURPOSE: Nursing informatics competency is used to manage and improve the delivery of safe, high-quality, and efficient healthcare services in accordance with best practices and professional and regulatory standards. This study examined the relationship between nursing informatics competency (NIC), nursing care left undone, and nurse reported quality of care (NQoC) and nursing productivity. A path model for their effects on nursing productivity among clinical nurses was also established. METHODS: Data were collected using structured questionnaires answered by 192 nurses working in a tertiary hospital located in J city, Korea, and analyzed using SPSS/WIN 23.0 and AMOS 21.0 program. RESULTS: The fit indices of the alternative path model satisfied recommended levels χ² = .11 (p = .741), normed χ² (χ²/df) = .11, SRMR = .01, RMSEA = .00, GFI = 1.00, NFI = 1.00, AIC = 18.11. Among the variables, NIC (ß = .44, p < .001), NQoC (ß = .35, p < .001) had a direct effect on nursing productivity. Due to the mediating effect of NQoC on the relationship between NIC and nursing productivity, the effect size was .14 (95% CI .08~.24). Meanwhile, nursing care left undone through NQoC in the relationship between NIC and nursing productivity, has a significant mediation effect (estimate .01, 95% CI .00~.03). The explanatory power of variables was 44.0%. CONCLUSION: Education and training for enhancing NIC should be provided to improve nursing productivity, quality of care and to reduce missed nursing care. Furthermore, monitoring the quality of nursing care and using it as a productivity index is essential.


Assuntos
Enfermeiras e Enfermeiros , Cuidados de Enfermagem , Informática em Enfermagem , Recursos Humanos de Enfermagem Hospitalar , Humanos , Inquéritos e Questionários
18.
Healthcare (Basel) ; 11(9)2023 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-37174815

RESUMO

Nursing surveillance is a defense mechanism that protects patients from adverse events, as it is a systematic process that contributes to nurses' detection of and intervention in dangerous situations. This descriptive cross-sectional study examined the degree of nursing surveillance activity performed by clinical nurses, nurses' perceived importance of nursing surveillance, and their perception of patient safety culture. The study aimed to identify the predictors of nursing surveillance activity. Participants included 205 clinical nurses from two secondary hospitals and two tertiary hospitals in Changwon-si and Cheongju-si, South Korea, who had at least one year of clinical experience. Nursing surveillance activity was high among nurses who were assigned fewer than 1.88 patients, who worked in a tertiary hospital, and those who scored 7.0 or higher in nurses' perceived expertise. Nursing surveillance activity was significantly positively correlated with nurses' perceived importance of nursing surveillance and patient safety culture. A hierarchical multiple regression analysis was performed to identify the predictors of nursing surveillance activity. Nurses' perceived expertise, perceived importance of nursing surveillance, patient safety culture, and type of hospital explained 65.3% of the variance of nursing surveillance activity. This study is significant as it provides an assessment of the extent and key predictors of nursing surveillance activity.

19.
Int J Radiat Oncol Biol Phys ; 117(3): 690-700, 2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-37201757

RESUMO

PURPOSE: The aim of this work was to prospectively evaluate the toxicity and cosmetic outcomes of 5-fraction, stereotactic, accelerated partial breast irradiation (APBI). METHODS AND MATERIALS: This prospective observational cohort study enrolled women who underwent APBI for invasive carcinoma or carcinoma in situ of the breast. APBI was delivered using a CyberKnife M6 robotic radiosurgery system at 30 Gy in 5 nonconsecutive, once-daily fractions. Women undergoing whole breast irradiation (WBI) were also enrolled for comparison. Patient-reported and physician-assessed adverse events were recorded. Breast fibrosis was measured using a tissue compliance meter, and breast cosmesis was assessed using BCCT.core (an automatic, computer-based software). Outcomes were collected until 24 months posttreatment according to the study protocol. RESULTS: In total, 204 patients (APBI, n = 103; WBI, n = 101) were enrolled. Regarding patient-reported outcomes, the APBI group reported significantly less skin dryness (6.9% vs 18.3%; P = .015), radiation skin reaction (9.9% vs 23.5%; P = .010), and breast hardness (8.0% vs 20.4%; P = .011) at 6 months than the WBI group. On physician assessment, the APBI group had significantly less dermatitis at 12 months (1.0% vs 7.2%; P = .027) than the WBI group. Any severe toxicities after APBI were rare in patient-reported outcomes (score ≥3, 3.0%) and physician assessments (grade ≥3, 2.0%). In the uninvolved quadrants, measured fibrosis in the APBI group was significantly lower than that in the WBI group at 6 (P = .001) and 12 (P = .029) months but not at 24 months. In the involved quadrant, measured fibrosis in the APBI group was not significantly different from that in the WBI group at any time. Cosmetic outcomes in the APBI group were mostly excellent or good (77.6%) at 24 months, and there was no significant cosmetic detriment from the baseline. CONCLUSIONS: Stereotactic APBI was associated with less fibrosis in the uninvolved breast quadrants than WBI. Patients showed minimal toxicity and no detrimental effects on cosmesis after APBI.


Assuntos
Neoplasias da Mama , Carcinoma in Situ , Feminino , Humanos , Neoplasias da Mama/radioterapia , Neoplasias da Mama/cirurgia , Neoplasias da Mama/patologia , Estudos Prospectivos , Mama/efeitos da radiação , Carcinoma in Situ/cirurgia , Fibrose , Resultado do Tratamento , Mastectomia Segmentar
20.
Healthcare (Basel) ; 11(10)2023 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-37239665

RESUMO

The aim of this study was to identify the influence of nursing unit team effectiveness on nursing care left undone and nurse-reported quality of care. This was a cross-sectional study with a sample of 230 nurses working at general hospitals in South Korea. Data were collected in January 2023 using an online questionnaire. Nursing unit team effectiveness was measured, consisting of the following sub-scales: leadership of the head nurse, cohesion, job satisfaction, competency of nurses, work productivity, and coordination. Multiple regression analyses were used to assess relationships between nursing unit team effectiveness and nursing care left undone and nursing-reported quality of care. Among these sub-domains, the study found that the higher the coordination (ß = -0.22, p < 0.001), the significantly lower the nursing care left undone. The higher the competency of nurses (ß = 0.26, p < 0.001) and work productivity (ß = 0.20, p < 0.001), the higher the nurse-reported quality of care. In addition, nursing care left undone had a negative effect on nurse-reported quality of care (ß = -0.15, p < 0.001). Therefore, nursing managers should make efforts to manage team effectiveness in nursing units to improve nurse-reported quality of care.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...