Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Pharm Res ; 40(10): 2355-2370, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37131104

RESUMO

BACKGROUND: Spray-drying is considered a promising alternative drying method to lyophilization (freeze-drying) for therapeutic proteins. Particle counts in reconstituted solutions of dried solid dosage forms of biologic drug products are closely monitored to ensure product quality. We found that high levels of particles formed after reconstitution of protein powders that had been spray-dried under suboptimal conditions. METHODS: Visible and subvisible particles were evaluated. Soluble proteins in solution before spray-drying and in the reconstituted solution of spray-dried powder were analyzed for their monomer content levels and melting temperatures. Insoluble particles were collected and analyzed by Fourier transform infrared microscopy (FTIR), and further analyzed with hydrogen-deuterium exchange (HDX). RESULTS: Particles observed after reconstitution were shown not to be undissolved excipients. FTIR confirmed their identity as proteinaceous in nature. These particles were therefore considered to be insoluble protein aggregates, and HDX was applied to investigate the mechanism underlying aggregate formation. Heavy-chain complementarity-determining region 1 (CDR-1) in the aggregates showed significant protection by HDX, suggesting CDR-1 was critical for aggregate formation. In contrast, various regions became more conformationally dynamic globally, suggesting the aggregates have lost protein structural integrity and partially unfolded after spray-drying. DISCUSSION: The spray-drying process could have disrupted the higher-order structure of proteins and exposed the hydrophobic residues in CDR-1 of the heavy chain, contributing to the formation of aggregate through hydrophobic interactions upon reconstitution of spray-dried powder. These results can contribute to efforts to design spray-dry resilient protein constructs and improve the robustness of the spray-drying process.


Assuntos
Microscopia , Proteínas , Pós/química , Liofilização , Tamanho da Partícula
2.
J Pharm Sci ; 111(3): 699-709, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34808214

RESUMO

The measurement of polydisperse protein aggregates and particles in biotherapeutics remains a challenge, especially for particles with diameters of ≈ 1 µm and below (sub-micrometer). This paper describes an interlaboratory comparison with the goal of assessing the measurement variability for the characterization of a sub-micrometer polydisperse particle dispersion composed of five sub-populations of poly(methyl methacrylate) (PMMA) and silica beads. The study included 20 participating laboratories from industry, academia, and government, and a variety of state-of-the-art particle-counting instruments. The received datasets were organized by instrument class to enable comparison of intralaboratory and interlaboratory performance. The main findings included high variability between datasets from different laboratories, with coefficients of variation from 13 % to 189 %. Intralaboratory variability was, on average, 37 % of the interlaboratory variability for an instrument class and particle sub-population. Drop-offs at either end of the size range and poor agreement on maximum counts of particle sub-populations were noted. The mean distributions from an instrument class, however, showed the size-coverage range for that class. The study shows that a polydisperse sample can be used to assess performance capabilities of an instrument set-up (including hardware, software, and user settings) and provides guidance for the development of polydisperse reference materials.


Assuntos
Laboratórios , Software , Tamanho da Partícula
3.
MAbs ; 12(1): 1738691, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32138591

RESUMO

When two therapeutic agents are combined in a single formulation, i.e., coformulated, the quality and safety of the individual agents must be preserved. Here we describe an approach to evaluate the quality attributes of two individual monoclonal antibodies (mAbs), designated mAb-A and mAb-B, in coformulation. The mAbs were fractionated from heat-stressed coformulated drug product (DP) by hydrophobic interaction chromatography. Each purified mAb fraction was then compared with mAb-A and mAb-B in their individual formulations from the same drug substance sources used to make the coformulated DP lot, which was subjected to the same stress conditions. Product variants were evaluated and compared by using several analytical tests, including high-performance size exclusion chromatography (HPSEC), reducing and nonreducing gel electrophoresis, ion-exchange chromatography, capillary isoelectric focusing, and peptide mapping with mass spectrometry. Intermolecular interactions in coformulated and photostressed DPs were studied by evaluating aggregates fractionated from coformulated DP by HPSEC. Aggregate fractions of coformulated DP contained dimers, but not coaggregates, of mAb-A or mAb-B. Moreover, extensive assays for higher-order structure and biological interactions confirmed that there was no interaction between the two mAb molecules in the coformulation. These results demonstrate that the two coformulated therapeutic mAbs had the same quality attributes as the individually formulated mAb-A and mAb-B, no new quality attributes were formed, and no physicochemical, intermolecular, or biological interactions occurred between the two components. The approach described here can be used to monitor the product quality of other coformulated antibodies.


Assuntos
Anticorpos Monoclonais/química , Combinação de Medicamentos , Animais , Humanos
4.
J Pharm Sci ; 106(11): 3280-3286, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-28734785

RESUMO

Stainless steel containers are widely used in the pharmaceutical and biopharmaceutical industry for the storage of buffers, process intermediates, and purified drug substance. They are generally held to be corrosion resistant, biocompatible, and nonreactive, although it is well established that trace amounts of metal ions can leach from stainless steel equipment into biopharmaceutical products. We report here that the use of stainless steel containers in conjunction with magnetic stirring bars leads to significantly aggravated metal contamination, consisting of both metal particles and significantly elevated metal ions in solution, the degree of which is several orders of magnitude higher than described for static conditions. Metal particles are analyzed by scanning electron microscopy with electron-dispersive X-ray spectroscopy, and metal content in solution is quantitated at different time points by inductively coupled plasma-mass spectrometry. The concentration of iron, chromium, nickel, and manganese increases with increasing stirring time and speed. We describe the impact of buffer components on the extent of metal particles and ions in solution and illustrate the effect on model proteins.


Assuntos
Composição de Medicamentos/métodos , Embalagem de Medicamentos/métodos , Metais/análise , Aço Inoxidável/química , Soluções Tampão , Cromo/análise , Corrosão , Contaminação de Medicamentos , Ferro/análise , Magnetismo/métodos , Imãs/química , Manganês/análise , Níquel/análise , Agregados Proteicos
5.
Soft Matter ; 12(14): 3293-302, 2016 Apr 14.
Artigo em Inglês | MEDLINE | ID: mdl-26891116

RESUMO

Protein molecules are amphiphilic moieties that spontaneously adsorb at the air/solution (A/S) interface to lower the surface energy. Previous studies have shown that hydrodynamic disruptions to these A/S interfaces can result in the formation of protein aggregates that are of concern to the pharmaceutical industry. Interfacial hydrodynamic stresses encountered by protein therapeutic solutions under typical manufacturing, filling, and shipping conditions will impact protein stability, prompting a need to characterize the contribution of basic fluid kinematics to monoclonal antibody (mAb) destabilization. We demonstrate that dilatational surface deformations are more important to antibody stability when compared to constant-area shear of the A/S interface. We have constructed a dilatational interfacial rheometer that utilizes simultaneous pressure and bubble shape measurements to study the mechanical stability of mAbs under interfacial aging. It has a distinct advantage over methods utilizing the Young-Laplace equation, which incorrectly describes viscoelastic interfaces. We provide visual evidence of particle ejection from dilatated A/S interfaces and spectroscopic data of ejected mAb particles. These rheological studies frame a molecular understanding of the protein-protein interactions at the complex-fluid interface.


Assuntos
Anticorpos Monoclonais/química , Elasticidade , Hidrodinâmica , Algoritmos , Estabilidade Proteica , Reologia/instrumentação , Tensoativos/química , Viscosidade
6.
Proc Natl Acad Sci U S A ; 104(31): 12651-6, 2007 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-17578926

RESUMO

Reverse transcription of the HIV-1 genome involves several nucleic acid rearrangement steps that are catalyzed (chaperoned) by the nucleocapsid protein (NC), including the annealing of the transactivation response region (TAR) RNA of the genome to the complementary sequence (TAR DNA) in minus-strand strong-stop DNA. It has been extremely challenging to obtain unambiguous mechanistic details on the annealing process at the molecular level because of the kinetic involvement of a complex and heterogeneous set of nucleic acid/protein complexes of variable structure and variable composition. Here, we investigate the in vitro annealing mechanism using a multistep single-molecule spectroscopy kinetic method. In this approach, an immobilized hairpin is exposed to a multistep programmed concentration sequence of NC, model complementary targeted-oligonucleotides, and buffer-only solutions. The sequence controllably "drags" single immobilized TAR hairpins among the kinetic stable states of the reaction mechanism; i.e., reactants, intermediates, and products. This single-molecule spectroscopy method directly probes kinetic reversibility and the chaperone (catalytic) role of NC at various stages along the reaction sequence, giving access to previously inaccessible kinetic processes and rate constants. By employing target oligonucleotides for specific TAR regions, we kinetically trap and investigate structural models for putative nucleation complexes for the annealing process. The new results lead to a more complete and detailed understanding of the ability of NC to promote nucleic acid/nucleic acid rearrangement processes. This includes information on the ability of NC to chaperone "reverse annealing" in single-strand transfer and the first observation of partially annealed, conformational substates in the annealing mechanism.


Assuntos
HIV-1/genética , HIV-1/metabolismo , Chaperonas Moleculares/metabolismo , Proteínas do Nucleocapsídeo/metabolismo , Transcrição Reversa/genética , Sequência de Bases , HIV-1/química , Cinética , Magnésio , Chaperonas Moleculares/genética , Dados de Sequência Molecular , Conformação de Ácido Nucleico , Proteínas do Nucleocapsídeo/genética , Oligonucleotídeos/química , Oligonucleotídeos/genética , Temperatura
7.
Proc Natl Acad Sci U S A ; 104(13): 5261-7, 2007 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-17372205

RESUMO

HIV-1 reverse transcription requires several nucleic acid rearrangement steps that are "chaperoned" by the nucleocapsid protein (NC), including minus-strand transfer, in which the DNA transactivation response element (TAR) is annealed to the complementary TAR RNA region of the viral genome. These various rearrangement processes occur in NC bound complexes of specific RNA and DNA structures. A major barrier to the investigation of these processes in vitro has been the diversity and heterogeneity of the observed nucleic acid/protein assemblies, ranging from small complexes of only one or two nucleic acid molecules all the way up to large-scale aggregates comprised of thousands of NC and nucleic acid molecules. Herein, we use a flow chamber approach involving rapid NC/nucleic acid mixing to substantially control aggregation for the NC chaperoned irreversible annealing kinetics of a model TAR DNA hairpin sequence to the complementary TAR RNA hairpin, i.e., to form an extended duplex. By combining the flow chamber approach with a broad array of fluorescence single-molecule spectroscopy (SMS) tools (FRET, molecule counting, and correlation spectroscopy), we have unraveled the complex, heterogeneous kinetics that occur during the course of annealing. The SMS results demonstrate that the TAR hairpin reactant is predominantly a single hairpin coated by multiple NCs with a dynamic secondary structure, involving equilibrium between a "Y" shaped conformation and a closed one. The data further indicate that the nucleation of annealing occurs in an encounter complex that is formed by two hairpins with one or both of the hairpins in the "Y" conformation.


Assuntos
HIV-1/metabolismo , Ácidos Nucleicos/química , Nucleocapsídeo/química , Transcrição Gênica , Ativação Transcricional , Sequência de Bases , Transferência Ressonante de Energia de Fluorescência , Cinética , Chaperonas Moleculares , Dados de Sequência Molecular , Conformação de Ácido Nucleico , Oligonucleotídeos/química , Ligação Proteica , Conformação Proteica , Temperatura
8.
J Biomed Opt ; 11(4): 041128, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16965156

RESUMO

Measurement accuracy for predicting glucose in whole blood was studied based on near-infrared spectroscopy. Optimal wavelength regions, preprocessing, and the influence of hemoglobin were examined using partial least-squares regression. Spectra between 1100 and 2400 nm were measured from 98 whole blood samples. In order to study the influence of hemoglobin, which is the most dominant component in blood, 98 samples were arranged such that glucose and hemoglobin concentrations were distributed in their physiological ranges. Samples were grouped into three depending on hemoglobin level. The results showed that glucose prediction was influenced by hemoglobin concentrations in the calibration model. It was necessary for samples used in the calibration model to represent the entire range of hemoglobin level. The cross-validation errors were the smallest when the wavelength regions of 1390 to 1888 nm and 2044 to 2393 nm were used. However, prediction accuracy was not very dependent on preprocessing methods in this optimal region. The standard error of glucose prediction was 25.5 mgdL and the coefficient of variation in prediction was 11.2%.


Assuntos
Algoritmos , Glicemia/análise , Hemoglobinas/análise , Espectrofotometria Infravermelho/métodos , Artefatos , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
9.
Appl Opt ; 42(4): 745-9, 2003 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-12564495

RESUMO

We have determined the glucose concentration of whole blood from mid-infrared spectra without sample preparation or use of chemical reagents. We selected 1119-1022 cm(-1) as the optimal wavelength range for our measurement by making a first-loading vector analysis based on partial least-squares regression. We examined the influence of hemoglobin on samples by using different calibration and prediction sets. The accuracy of glucose prediction depended on the hemoglobin level in the calibration model; the sample set should represent the entire range of hemoglobin concentration. We obtained an accuracy of 5.9% in glucose prediction, and this value is well within a clinically acceptable range.


Assuntos
Glicemia/análise , Espectrofotometria Infravermelho , Hemoglobinas/análise , Humanos
10.
Appl Opt ; 41(7): 1469-75, 2002 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-11900028

RESUMO

A method and device for measuring glucose concentration in a scattering medium have been developed. A spectral range of 800-1800 nm is considered for wavelength selection because of its deeper penetration into biological tissue and the presence of a glucose absorption band. An algorithm based on selected wavelengths is proposed to minimize interference from other components. The optimal distance between the light source and the detector for diffuse reflectance measurement minimizes the influence of medium scattering. The proposed algorithm and measuring device are tested with a solution containing milk with added glucose. Glucose concentrations between 0 and 2000 mg/dl are determined with a correlation coefficient of 0.977. We also investigate the influence of concentration variations of other substances such as water, hemoglobin, albumin, and cholesterol when they are mixed in a scattering medium.


Assuntos
Glucose/análise , Algoritmos , Animais , Análise Química do Sangue/instrumentação , Análise Química do Sangue/métodos , Equipamentos e Provisões , Luz , Leite/química , Modelos Teóricos , Concentração Osmolar , Espalhamento de Radiação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...