Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Med Cases ; 11(1): 30-33, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34434333

RESUMO

A strong association of gemcitabine to acute coronary syndrome (ACS) is not currently established in the literature. In this series, we highlight that both patients with gemcitabine-related ACS were more than 50 years old, had underlying coronary artery disease and suffered from metastatic cancer. However, further prospective studies are required to validate the significance of these observations.

2.
JACC Case Rep ; 1(4): 622-625, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34316892

RESUMO

Due to the scarcity of data, Impella RP is not approved for acute right ventricular failure caused by massive pulmonary embolism. We describe here the successful use of Impella RP in acute right ventricular failure caused by massive pulmonary embolism to highlight its promising outcome in such an indication. (Level of Difficulty: Advanced.).

3.
eNeuro ; 5(6)2018.
Artigo em Inglês | MEDLINE | ID: mdl-30627656

RESUMO

A multielectrode system that can address widely separated targets at multiple sites across multiple brain regions with independent implant angling is needed to investigate neural function and signaling in systems and circuits of small animals. Here, we present the systemDrive, a novel multisite, multiregion microdrive that is capable of moving microwire electrode bundles into targets along independent and nonparallel drive trajectories. Our design decouples the stereotaxic surgical placement of individual guide cannulas for each trajectory from the placement of a flexible drive structure. This separation enables placement of many microwire multitrodes along widely spaced and independent drive axes with user-set electrode trajectories and depths from a single microdrive body, and achieves stereotaxic precision with each. The system leverages tight tube-cannula tolerances and geometric constraints on flexible drive axes to ensure concentric alignment of electrode bundles within guide cannulas. Additionally, the headmount and microdrive both have an open-center design to allow for the placement of additional sensing modalities. This design is the first, in the context of small rodent chronic research, to provide the capability to finely position microwires through multiple widely distributed cell groups, each with stereotaxic precision, along arbitrary and nonparallel trajectories that are not restricted to emanate from a single source. We demonstrate the use of the systemDrive in male Long-Evans rats to observe simultaneous single-unit and multiunit activity from multiple widely separated sleep-wake regulatory brainstem cell groups, along with cortical and hippocampal activity, during free behavior over multiple many-day continuous recording periods.


Assuntos
Encéfalo/fisiologia , Eletrodos Implantados , Eletrofisiologia/instrumentação , Eletrofisiologia/métodos , Potenciais Evocados/fisiologia , Vigília/fisiologia , Animais , Encéfalo/citologia , Masculino , Microeletrodos , Vias Neurais/fisiologia , Neurônios/fisiologia , Ratos , Ratos Long-Evans , Técnicas Estereotáxicas/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA