Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
Int J Surg Case Rep ; 53: 43-45, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30368124

RESUMO

BACKGROUND: Laparoscopic cholecystectomy (LC) is considered the gold standard operation for symptomatic gallstones. Gallbladder perforation occurs in 6-40% of operations. It can lead to spillage of gallstones into the abdominal cavity with possible consequences of long-term complications. We report two cases where a unique use of laparoscopic technique was used to explore abscess cavity and retrieve lost gallstones without penetrating the peritoneal cavity. CASE PRESENTATION: We report two cases of peri-hepatic abscess treated with laparoscopic cavity exploration, using 5 mm and 10 mm ports, to retrieve lost gallstones. It was done without entering the peritoneal cavity. DISCUSSION: Today, minimally invasive technique is used in a variety of surgical cases. We report a novel technique, using laparoscopic skills, to drain abscesses caused by lost gallstones post LC without entering the peritoneal cavity. The use of minimally invasive surgery techniques in order to explore abscess cavities not only help us to extract the cause of the abscess but also prevents another surgery in the abdominal cavity. CONCLUSION: Laparoscopic exploration of an abscess cavity is a feasible and safe technique treating long-term complications of gallbladder perforation post LC.

3.
Expert Rev Med Devices ; 4(6): 821-8, 2007 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-18035948

RESUMO

The creation of anastomoses between various parts of the GI tract is a major task in the daily practice of oncological, reconstructive and transplant surgery. The most widely used anastomosing techniques today involve the use of sutures or metal titanium staples. Both techniques involve foreign material penetrating the tissue and evoking localized inflammatory response, tissue injury and breaking of mucosal barriers that may facilitate bacterial growth within the anastomotic line, increasing the propensity to anastomotic-related morbidity. Different types of compression devices were successfully used clinically in the past. The history and evolving characteristics of this technology is reviewed. Nitinol-based solutions for the creation of compression anastomosis are evaluated as a possible potential for revolutionary impact on the current surgical methods and anastomosing technology in the alimentary tract and beyond.


Assuntos
Anastomose Cirúrgica/métodos , Trato Gastrointestinal/cirurgia , Ligas , Anastomose Cirúrgica/efeitos adversos , Humanos , Cicatrização
4.
World J Surg ; 31(3): 532-7, 2007 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-17334866

RESUMO

BACKGROUND: Generations of investigators have attempted to achieve compression bowel anastomosis by a sutureless device, providing temporary support to the tissue and facilitating the natural healing process. The biocompatibility of nickel-titanium alloy has made it attractive for use in medical implants and devices, and several studies have described the creation of a side-to-side compression anastomosis in colon surgery with a nickel-titanium clip. We evaluated the feasibility and safety of a newly designed gun for applying a nickel-titanium compression anastomosis ring (CAR) to create an end-to-end colorectal anastomosis in a porcine model. MATERIALS AND METHODS: A segment of the proximal rectum was resected in 25 pigs. The bowel ends were anastomosed transanally by an end-to-end CAR device. The animals' follow-up continued for up to 8 weeks, and included general health status, weight gain, blood tests, and abdominal X-ray. They were then sacrificed. The anastomoses were studied for burst pressure, anastomotic index, and histopathology. RESULTS: One pig died due to iatrogenic bowel injury unrelated to the CAR device. There was no other morbidity/mortality. The other animals recovered and gained weight. Burst pressure studies demonstrated a minimum pressure of 160 mmHg at time point 0 that escalated quickly to >300 mmHg. The mean anastomotic index after 8 weeks was 0.81. Histologic evaluation revealed minimal inflammation and minimal fibrosis at the anastomosis site. CONCLUSION: The principles of compression anastomosis are better executed with the use of memory shape alloys. The promising results of this novel technique should encourage further studies of this technology.


Assuntos
Anastomose Cirúrgica/instrumentação , Reto/cirurgia , Animais , Materiais Biocompatíveis , Estudos de Viabilidade , Feminino , Níquel , Desenho de Prótese , Implantação de Prótese , Suínos , Titânio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA