Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Acta Radiol ; 52(6): 692-8, 2011 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-21508198

RESUMO

BACKGROUND: Although CT urography (CTU) is widely used for the evaluation of the entire urinary tract, the most important drawback is the radiation exposure. PURPOSE: To evaluate the effect of a noise reduction filter (NRF) using a phantom and to quantitatively and qualitatively compare excretory phase (EP) images using a low noise index (NI) with those using a high NI and postprocessing NRF (pNRF). MATERIAL AND METHODS: Each NI value was defined for a slice thickness of 5 mm, and reconstructed images with a slice thickness of 1.25 mm were assessed. Sixty patients who were at high risk of developing bladder tumors (BT) were divided into two groups according to whether their EP images were obtained using an NI of 9.88 (29 patients; group A) or an NI of 20 and pNRF (31 patients; group B). The CT dose index volume (CTDI(vol)) and the contrast-to-noise ratio (CNR) of the bladder with respect to the anterior pelvic fat were compared in both groups. Qualitative assessment of the urinary bladder for image noise, sharpness, streak artifacts, homogeneity, and the conspicuity of polypoid or sessile-shaped BTs with a short-axis diameter greater than 10 mm was performed using a 3-point scale. RESULTS: The phantom study showed noise reduction of approximately 40% and 76% dose reduction between group A and group B. CTDI(vol) demonstrated a 73% reduction in group B (4.6 ± 1.1 mGy) compared with group A (16.9 ± 3.4 mGy). The CNR value was not significantly different (P = 0.60) between group A (16.1 ± 5.1) and group B (16.6 ± 7.6). Although group A was superior (P < 0.01) to group B with regard to image noise, other qualitative analyses did not show significant differences. CONCLUSION: EP images using a high NI and pNRF were quantitatively and qualitatively comparable to those using a low NI, except with regard to image noise.


Assuntos
Tomografia Computadorizada por Raios X/métodos , Neoplasias da Bexiga Urinária/diagnóstico por imagem , Urografia/métodos , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos
2.
Radiology ; 229(3): 718-23, 2003 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-14657307

RESUMO

PURPOSE: To investigate the association between periprosthetic signal intensity at low-field-strength magnetic resonance (MR) imaging after failed hip arthroplasty and radiographic, surgical, and pathologic findings. MATERIALS AND METHODS: The study group comprised 22 consecutive women who underwent hip arthroplasty (mean age, 62 years; age range, 35-74 years). All patients underwent MR imaging prior to revision surgery. Coronal fast short inversion time inversion-recovery (STIR) images and spin-echo T1-weighted images were obtained with a 0.5-T MR imaging unit before and after administration of contrast material. The periprosthetic region was divided into the seven femoral Gruen zones. Two observers retrospectively analyzed signal intensity patterns. Association of signal intensity patterns with radiographic, surgical, and pathologic findings was determined with chi2 analysis and generalized estimating equations. RESULTS: Diagnostic-quality images were obtained for 150 zones. Periprosthetic signal intensity was greater than that of bone marrow in the distal femur on the fast STIR images, and no contrast enhancement was seen on the T1-weighted images (type I signal intensity pattern) in 11 zones. Signal intensity was greater than that of bone marrow on the fast STIR images, and contrast enhancement was seen on the T1-weighted images (type II signal intensity pattern) in 45 zones. Signal intensity was less than or equal to that of bone marrow on the fast STIR images, and no contrast enhancement was seen on the T1-weighted images (type III signal intensity pattern) in 94 zones. Type I and II patterns were associated with focal or nonfocal lucency, an unstable stem, and fibrosis or granuloma. A type III pattern was associated with a normal radiographic appearance, a stable stem, and normal bone tissue. Significant association was demonstrated between periprosthetic signal intensity and radiographic (P <.001, chi2 test and generalized estimating equations), surgical (P <.05, Mantel-Haenszel chi2 test and generalized estimating equations), and pathologic findings (P <.05, chi2 test). CONCLUSION: Low-field-strength MR imaging depicted periprosthetic tissue signal intensity that was significantly associated with radiographic, surgical, and pathologic findings.


Assuntos
Artroplastia de Quadril , Fêmur/patologia , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Feminino , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Humanos , Pessoa de Meia-Idade , Falha de Prótese , Radiografia , Reoperação
3.
Nihon Igaku Hoshasen Gakkai Zasshi ; 63(9): 588-90, 2003 Nov.
Artigo em Japonês | MEDLINE | ID: mdl-14699871

RESUMO

CT has great advantages in detecting early-stage small lung cancer and is becoming common in lung cancer screening. Multi-detector-row CT (MDCT) can provide thin-slice images with low radiation exposure. In this study, ultra-low-dose (5 mAs: 10 mAs, 0.5 sec/rot) thoracic MDCT images were evaluated. We describe the differences in image quality and quantity between the different reconstruction kernels. We also propose a new reconstruction algorithm (ultra-low-dose reconstruction algorithm: ULR) for ultra-low-dose thoracic CT, to reduce noise and streak artifacts. We are convinced of the usefulness and possibility of ultra-low-dose thoracic MDCT with ULR algorithms for lung cancer screening.


Assuntos
Algoritmos , Radiografia Torácica/métodos , Tomografia Computadorizada por Raios X/métodos , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Doses de Radiação
4.
Magn Reson Med Sci ; 1(2): 81-7, 2002 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-16082130

RESUMO

The purpose of this study was to determine whether a distinction could be made between benign and malignant urinary obstructions in moderately T(2)-weighted images obtained with the single-shot fast spin-echo technique. Forty-four lesions in 39 patients with urinary obstruction were evaluated with the single-shot fast spin-echo (SSFSE) technique with an effective TE of 90-100 ms and without fat saturation. Benign and malignant lesions were compared for the presence of ureteral wall thickening and a signal intensity relative to the proximal ureteral wall. Statistically significant differences were found between benign and malignant lesions in both morphologic change (P<0.0001) and signal intensity of the lesions at the obstruction position (P<0.0001). The combination of wall thickening and increased signal intensity as a predictor of malignant disease yielded a sensitivity of 88% and a specificity of 100%. Neither increased signal intensity nor wall thickening as a predictor of benign disease yielded a sensitivity of 89% and a specificity of 88%. The moderately T(2)-weighted SSFSE technique without fat saturation can accurately distinguish between benign and malignant urinary obstructions.


Assuntos
Imageamento por Ressonância Magnética/métodos , Obstrução do Colo da Bexiga Urinária/patologia , Retenção Urinária/patologia , Neoplasias Urológicas/patologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Diagnóstico Diferencial , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...