1.
Small ; 19(49): e2305017, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37528504

RESUMO

Eco/bioresorbable electronics represent an emerging class of technology defined by an ability to dissolve or otherwise harmlessly disappear in environmental or biological surroundings after a period of stable operation. The resulting devices provide unique capabilities as temporary biomedical implants, environmental sensors, and related systems. Recent publications report schemes to overcome challenges in fabrication that follow from the low thermostability and/or high chemical reactivity of the eco/bioresorbable constituent materials. Here, this work reports the use of high-speed sewing machines, as the basis for a high-throughput manufacturing technique that addresses many requirements for these applications, without the need for high temperatures or reactive solvents. Results demonstrate that a range of eco/bioresorbable metal wires and polymer threads can be embroidered into complex, user-defined conductive patterns on eco/bioresorbable substrates. Functional electronic components, such as stretchable interconnects and antennas are possible, along with fully integrated systems. Examples of the latter include wirelessly powered light-emitting diodes, radiofrequency identification tags, and temporary cardiac pacemakers. These advances add to a growing range of options in high-throughput, automated fabrication of eco/bioresorbable electronics.


Assuntos
Implantes Absorvíveis , Eletrônica , Metais , Polímeros , Solventes
2.
Nat Commun ; 14(1): 1024, 2023 02 23.
Artigo em Inglês | MEDLINE | ID: mdl-36823288

RESUMO

Soft, wireless physiological sensors that gently adhere to the skin are capable of continuous clinical-grade health monitoring in hospital and/or home settings, of particular value to critically ill infants and other vulnerable patients, but they present risks for injury upon thermal failure. This paper introduces an active materials approach that automatically minimizes such risks, to complement traditional schemes that rely on integrated sensors and electronic control circuits. The strategy exploits thin, flexible bladders that contain small volumes of liquid with boiling points a few degrees above body temperature. When the heat exceeds the safe range, vaporization rapidly forms highly effective, thermally insulating structures and delaminates the device from the skin, thereby eliminating any danger to the skin. Experimental and computational thermomechanical studies and demonstrations in a skin-interfaced mechano-acoustic sensor illustrate the effectiveness of this simple thermal safety system and suggest its applicability to nearly any class of skin-integrated device technology.


Assuntos
Eletrônica , Pele , Humanos , Pele/química , Temperatura Corporal , Temperatura Alta , Software
3.
Proc Natl Acad Sci U S A ; 120(6): e2217828120, 2023 02 07.
Artigo em Inglês | MEDLINE | ID: mdl-36716364

RESUMO

Thermal sensations contribute to our ability to perceive and explore the physical world. Reproducing these sensations in a spatiotemporally programmable manner through wireless computer control could enhance virtual experiences beyond those supported by video, audio and, increasingly, haptic inputs. Flexible, lightweight and thin devices that deliver patterns of thermal stimulation across large areas of the skin at any location of the body are of great interest in this context. Applications range from those in gaming and remote socioemotional communications, to medical therapies and physical rehabilitation. Here, we present a set of ideas that form the foundations of a skin-integrated technology for power-efficient generation of thermal sensations across the skin, with real-time, closed-loop control. The systems exploit passive cooling mechanisms, actively switchable thermal barrier interfaces, thin resistive heaters and flexible electronics configured in a pixelated layout with wireless interfaces to portable devices, the internet and cloud data infrastructure. Systematic experimental studies and simulation results explore the essential mechanisms and guide the selection of optimized choices in design. Demonstration examples with human subjects feature active thermoregulation, virtual social interactions, and sensory expansion.


Assuntos
Pele , Realidade Virtual , Humanos , Eletrônica , Sensação Térmica , Comunicação
4.
Adv Sci (Weinh) ; 9(24): e2104454, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35780492

RESUMO

Metal additive manufacturing (AM) enables unparalleled design freedom for the development of optimized devices in a plethora of applications. The requirement for the use of nonconventional aluminum alloys such as AlSi10Mg has made the rational micro/nanostructuring of metal AM challenging. Here, the techniques are developed and the fundamental mechanisms governing the micro/nanostructuring of AlSi10Mg, the most common metal AM material, are investigated. A surface structuring technique is rationally devised to form previously unexplored two-tier nanoscale architectures that enable remarkably low adhesion, excellent resilience to condensation flooding, and enhanced liquid-vapor phase transition. Using condensation as a demonstration framework, it is shown that the two-tier nanostructures achieve 6× higher heat transfer coefficient when compared to the best filmwise condensation. The study demonstrates that AM-enabled nanostructuring is optimal for confining droplets while reducing adhesion to facilitate droplet detachment. Extensive benchmarking with past reported data shows that the demonstrated heat transfer enhancement has not been achieved previously under high supersaturation conditions using conventional aluminum, further motivating the need for AM nanostructures. Finally, it has been demonstrated that the synergistic combination of wide AM design freedom and optimal AM nanostructuring method can provide an ultracompact condenser having excellent thermal performance and power density.

5.
Analyst ; 147(17): 3838-3853, 2022 Aug 22.
Artigo em Inglês | MEDLINE | ID: mdl-35726910

RESUMO

Rapid, simple, inexpensive, accurate, and sensitive point-of-care (POC) detection of viral pathogens in bodily fluids is a vital component of controlling the spread of infectious diseases. The predominant laboratory-based methods for sample processing and nucleic acid detection face limitations that prevent them from gaining wide adoption for POC applications in low-resource settings and self-testing scenarios. Here, we report the design and characterization of an integrated system for rapid sample-to-answer detection of a viral pathogen in a droplet of whole blood comprised of a 2-stage microfluidic cartridge for sample processing and nucleic acid amplification, and a clip-on detection instrument that interfaces with the image sensor of a smartphone. The cartridge is designed to release viral RNA from Zika virus in whole blood using chemical lysis, followed by mixing with the assay buffer for performing reverse-transcriptase loop-mediated isothermal amplification (RT-LAMP) reactions in six parallel microfluidic compartments. The battery-powered handheld detection instrument uniformly heats the compartments from below, and an array of LEDs illuminates from above, while the generation of fluorescent reporters in the compartments is kinetically monitored by collecting a series of smartphone images. We characterize the assay time and detection limits for detecting Zika RNA and gamma ray-deactivated Zika virus spiked into buffer and whole blood and compare the performance of the same assay when conducted in conventional PCR tubes. Our approach for kinetic monitoring of the fluorescence-generating process in the microfluidic compartments enables spatial analysis of early fluorescent "bloom" events for positive samples, in an approach called "Spatial LAMP" (S-LAMP). We show that S-LAMP image analysis reduces the time required to designate an assay as a positive test, compared to conventional analysis of the average fluorescent intensity of the entire compartment. S-LAMP enables the RT-LAMP process to be as short as 22 minutes, resulting in a total sample-to-answer time in the range of 17-32 minutes to distinguish positive from negative samples, while demonstrating a viral RNA detection as low as 2.70 × 102 copies per µl, and a gamma-irradiated virus of 103 virus particles in a single 12.5 µl droplet blood sample.


Assuntos
Infecção por Zika virus , Zika virus , Humanos , Microfluídica , Técnicas de Diagnóstico Molecular , Técnicas de Amplificação de Ácido Nucleico/métodos , RNA Viral/genética , Sensibilidade e Especificidade , Smartphone , Instrumentos Cirúrgicos , Zika virus/genética , Infecção por Zika virus/diagnóstico
6.
Curr Opin Solid State Mater Sci ; 26(1): 100966, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34840515

RESUMO

The COVID-19 pandemic revealed fundamental limitations in the current model for infectious disease diagnosis and serology, based upon complex assay workflows, laboratory-based instrumentation, and expensive materials for managing samples and reagents. The lengthy time delays required to obtain test results, the high cost of gold-standard PCR tests, and poor sensitivity of rapid point-of-care tests contributed directly to society's inability to efficiently identify COVID-19-positive individuals for quarantine, which in turn continues to impact return to normal activities throughout the economy. Over the past year, enormous resources have been invested to develop more effective rapid tests and laboratory tests with greater throughput, yet the vast majority of engineering and chemistry approaches are merely incremental improvements to existing methods for nucleic acid amplification, lateral flow test strips, and enzymatic amplification assays for protein-based biomarkers. Meanwhile, widespread commercial availability of new test kits continues to be hampered by the cost and time required to develop single-use disposable microfluidic plastic cartridges manufactured by injection molding. Through development of novel technologies for sensitive, selective, rapid, and robust viral detection and more efficient approaches for scalable manufacturing of microfluidic devices, we can be much better prepared for future management of infectious pathogen outbreaks. Here, we describe how photonic metamaterials, graphene nanomaterials, designer DNA nanostructures, and polymers amenable to scalable additive manufacturing are being applied towards overcoming the fundamental limitations of currently dominant COVID-19 diagnostic approaches. In this paper, we review how several distinct classes of nanomaterials and nanochemistry enable simple assay workflows, high sensitivity, inexpensive instrumentation, point-of-care sample-to-answer virus diagnosis, and rapidly scaled manufacturing.

7.
Anal Chem ; 93(29): 10048-10055, 2021 07 27.
Artigo em Inglês | MEDLINE | ID: mdl-34251790

RESUMO

Biomedical diagnostics based on microfluidic devices have the potential to significantly benefit human health; however, the manufacturing of microfluidic devices is a key limitation to their widespread adoption. Outbreaks of infectious disease continue to demonstrate the need for simple, sensitive, and translatable tests for point-of-care use. Additive manufacturing (AM) is an attractive alternative to conventional approaches for microfluidic device manufacturing based on injection molding; however, there is a need for development and validation of new AM process capabilities and materials that are compatible with microfluidic diagnostics. In this paper, we demonstrate the development and characterization of AM cartridges using continuous liquid interface production (CLIP) and investigate process characteristics and capabilities of the AM microfluidic device manufacturing. We find that CLIP accurately produces microfluidic channels as small as 400 µm and that it is possible to routinely produce fluid channels as small as 100 µm with high repeatability. We also developed a loop-mediated isothermal amplification (LAMP) assay for detection of E. coli from whole blood directly on the CLIP-based AM microfluidic cartridges, with a 50 cfu/µL limit of detection, validating the use of CLIP processes and materials for pathogen detection. The portable diagnostic platform presented in this paper could be used to investigate and validate other AM processes for microfluidic diagnostics and could be an important component of scaling up the diagnostics for current and future infectious diseases and pandemics.


Assuntos
Técnicas Analíticas Microfluídicas , Microfluídica , Escherichia coli/genética , Humanos , Técnicas de Diagnóstico Molecular , Técnicas de Amplificação de Ácido Nucleico
8.
J Occup Environ Hyg ; 18(8): 369-377, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34170797

RESUMO

The National Institute for Occupational Safety and Health's methods and requirements for air-purifying respirator breathing resistance in 42 CFR Part 84 do not include work of breathing. The International Organization for Standardization Technical Committee 94, Subcommittee 15 utilized work of breathing to evaluate airflow resistance for all classes of respiratory protective devices as part of their development of performance standards regarding respiratory protective devices. The objectives of this study were: (1) to evaluate the relationship between the International Organization for Standardization's work of breathing measurements and the National Institute for Occupational Safety and Health's breathing resistance test results; (2) to provide scientific bases for standard development organizations to decide if work of breathing should be adopted; and (3) to establish regression equations for manufacturers and test laboratories to estimate work of breathing measurements using breathing resistance data. A total of 43 respirators were tested for work of breathing at minute ventilation rates of 10, 35, 65, 105, and 135 liters per minute. Breathing resistance obtained at a constant flow rate of 85 liters per minute per National Institute of Occupational Safety and Health protocol was correlated to each of the parameters (total work of breathing, inhalation, and exhalation) obtained from the work of breathing tests. The ratio of work of breathing exhalation to work of breathing inhalation for all air-purifying respirators is similar to the ratio of exhalation to inhalation resistance when tested individually. The ratios were about 0.8 for filtering facepiece respirators, 0.5 for half-masks, and 0.25 for full-facepiece respirators. The National Institute for Occupational Safety and Health's breathing resistance is close to work of breathing's minute ventilation of 35 liters per minute, which represents the common walking/working pace in most workplaces. The work of breathing and the National Institute of Occupational Safety and Health's breathing resistance were found to be strongly and positively correlated (r values of 0.7-0.9) at each work rate for inhalation and exhalation. In addition, linear and multiple regression models (R-squared values of 0.5-0.8) were also established to estimate work of breathing using breathing resistance. Work of breathing was correlated higher to breathing resistance for full-facepiece and half-mask elastomeric respirators than filtering facepiece respirators for inhalation. For exhalation, filtering facepiece respirators were correlated much better than full-facepiece and half-mask elastomeric respirators. Therefore, the National Institute for Occupational Safety and Health's breathing resistance may reasonably be used to predict work of breathing for air-purifying respirators. The results could also be used by manufacturers for product development and evaluation.


Assuntos
Exposição Ocupacional , Saúde Ocupacional , Dispositivos de Proteção Respiratória , Filtração , National Institute for Occupational Safety and Health, U.S. , Exposição Ocupacional/prevenção & controle , Taxa Respiratória , Estados Unidos , Trabalho Respiratório
9.
ACS Omega ; 6(5): 4013-4021, 2021 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-33585777

RESUMO

Two-dimensional (2D) materials and heterostructures are promising candidates for nanoelectronics. However, the quality of material interfaces often limits the performance of electronic devices made from atomically thick 2D materials and heterostructures. Atomic force microscopy (AFM) tip-based cleaning is a reliable technique to remove interface contaminants and flatten heterostructures. Here, we demonstrate AFM tip-based cleaning applied to hBN-encapsulated monolayer MoS2 transistors, which results in electrical performance improvements of the devices. To investigate the impact of cleaning on device performance, we compared the characteristics of as-transferred heterostructures and transistors before and after tip-based cleaning using photoluminescence (PL) and electronic measurements. The PL linewidth of monolayer MoS2 decreased from 84 meV before cleaning to 71 meV after cleaning. The extrinsic mobility of monolayer MoS2 field-effect transistors increased from 21 cm2/Vs before cleaning to 38 cm2/Vs after cleaning. Using the results from AFM topography, photoluminescence, and back-gated field-effect measurements, we infer that tip-based cleaning enhances the mobility of hBN-encapsulated monolayer MoS2 by reducing interface disorder. Finally, we fabricate a MoS2 field-effect transistor (FET) from a tip-cleaned heterostructure and achieved a device mobility of 73 cm2/Vs. The results of this work could be used to improve the electrical performance of heterostructure devices and other types of mechanically assembled van der Waals heterostructures.

10.
PLoS One ; 15(12): e0244963, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33378363

RESUMO

The COVID-19 pandemic disrupted the world in 2020 by spreading at unprecedented rates and causing tens of thousands of fatalities within a few months. The number of deaths dramatically increased in regions where the number of patients in need of hospital care exceeded the availability of care. Many COVID-19 patients experience Acute Respiratory Distress Syndrome (ARDS), a condition that can be treated with mechanical ventilation. In response to the need for mechanical ventilators, designed and tested an emergency ventilator (EV) that can control a patient's peak inspiratory pressure (PIP) and breathing rate, while keeping a positive end expiratory pressure (PEEP). This article describes the rapid design, prototyping, and testing of the EV. The development process was enabled by rapid design iterations using additive manufacturing (AM). In the initial design phase, iterations between design, AM, and testing enabled a working prototype within one week. The designs of the 16 different components of the ventilator were locked by additively manufacturing and testing a total of 283 parts having parametrically varied dimensions. In the second stage, AM was used to produce 75 functional prototypes to support engineering evaluation and animal testing. The devices were tested over more than two million cycles. We also developed an electronic monitoring system and with automatic alarm to provide for safe operation, along with training materials and user guides. The final designs are available online under a free license. The designs have been transferred to more than 70 organizations in 15 countries. This project demonstrates the potential for ultra-fast product design, engineering, and testing of medical devices needed for COVID-19 emergency response.


Assuntos
COVID-19/terapia , Desenho de Equipamento/métodos , Respiração Artificial/instrumentação , Ventiladores Mecânicos/efeitos adversos , Animais , COVID-19/patologia , Humanos , Respiração Artificial/métodos , Mecânica Respiratória/fisiologia , Taxa Respiratória/fisiologia , SARS-CoV-2 , Suínos
11.
Proc Natl Acad Sci U S A ; 117(37): 22727-22735, 2020 09 15.
Artigo em Inglês | MEDLINE | ID: mdl-32868442

RESUMO

The COVID-19 pandemic provides an urgent example where a gap exists between availability of state-of-the-art diagnostics and current needs. As assay protocols and primer sequences become widely known, many laboratories perform diagnostic tests using methods such as RT-PCR or reverse transcription loop mediated isothermal amplification (RT-LAMP). Here, we report an RT-LAMP isothermal assay for the detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) virus and demonstrate the assay on clinical samples using a simple and accessible point-of-care (POC) instrument. We characterized the assay by dipping swabs into synthetic nasal fluid spiked with the virus, moving the swab to viral transport medium (VTM), and sampling a volume of the VTM to perform the RT-LAMP assay without an RNA extraction kit. The assay has a limit of detection (LOD) of 50 RNA copies per µL in the VTM solution within 30 min. We further demonstrate our assay by detecting SARS-CoV-2 viruses from 20 clinical samples. Finally, we demonstrate a portable and real-time POC device to detect SARS-CoV-2 from VTM samples using an additively manufactured three-dimensional cartridge and a smartphone-based reader. The POC system was tested using 10 clinical samples, and was able to detect SARS-CoV-2 from these clinical samples by distinguishing positive samples from negative samples after 30 min. The POC tests are in complete agreement with RT-PCR controls. This work demonstrates an alternative pathway for SARS-CoV-2 diagnostics that does not require conventional laboratory infrastructure, in settings where diagnosis is required at the point of sample collection.


Assuntos
Infecções por Coronavirus/diagnóstico , Técnicas de Diagnóstico Molecular/métodos , Pneumonia Viral/diagnóstico , Testes Imediatos/normas , Reação em Cadeia da Polimerase Via Transcriptase Reversa/métodos , Betacoronavirus/genética , Betacoronavirus/patogenicidade , COVID-19 , Humanos , Limite de Detecção , Técnicas de Diagnóstico Molecular/instrumentação , Técnicas de Diagnóstico Molecular/normas , Mucosa Nasal/virologia , Pandemias , Reprodutibilidade dos Testes , Reação em Cadeia da Polimerase Via Transcriptase Reversa/instrumentação , Reação em Cadeia da Polimerase Via Transcriptase Reversa/normas , SARS-CoV-2 , Smartphone
12.
Nat Commun ; 11(1): 3463, 2020 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-32651374

RESUMO

Understanding the atomistic origin of defects in two-dimensional transition metal dichalcogenides, their impact on the electronic properties, and how to control them is critical for future electronics and optoelectronics. Here, we demonstrate the integration of thermochemical scanning probe lithography (tc-SPL) with a flow-through reactive gas cell to achieve nanoscale control of defects in monolayer MoS2. The tc-SPL produced defects can present either p- or n-type doping on demand, depending on the used gasses, allowing the realization of field effect transistors, and p-n junctions with precise sub-µm spatial control, and a rectification ratio of over 104. Doping and defects formation are elucidated by means of X-Ray photoelectron spectroscopy, scanning transmission electron microscopy, and density functional theory. We find that p-type doping in HCl/H2O atmosphere is related to the rearrangement of sulfur atoms, and the formation of protruding covalent S-S bonds on the surface. Alternatively, local heating MoS2 in N2 produces n-character.

13.
Adv Mater ; 31(39): e1903424, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31389640

RESUMO

A new compound material of 2D hydrofluorinated graphene (HFG) is demonstrated whose relative hydrogen/fluorine concentrations can be tailored between the extremes of either hydrogenated graphene (HG) and fluorinated graphene (FG). The material is fabricated through subsequent exposures to indirect hydrogen plasma and xenon difluoride (XeF2 ). Controlling the relative concentration in the HFG compound enables tailoring of material properties between the extremes offered by the constituent materials and in-plane patterning produces micrometer-scale regions with different surface properties. The utility of the technique to tailor the surface wettability, surface friction, and electrical conductivity is demonstrated. HFG compounds display wettability between the extremes of pure FG with contact angle of 95° ± 5° and pure HG with contact angle of 42° ± 2°. Similarly, the HFG surface friction may be tailored between the two extremes. Finally, the HFG electrical conductivity tunes through five orders of magnitude when transitioning from FG to HG. When combined with simulation, the electrical measurements reveal the mechanism producing the compound to be a dynamic process of adatom desorption and replacement. This study opens a new class of 2D compound materials and innovative chemical patterning with applications for atomically thin 2D circuits consisting of chemically/electrically modulated regions.

14.
Nano Lett ; 19(3): 2092-2098, 2019 03 13.
Artigo em Inglês | MEDLINE | ID: mdl-30808165

RESUMO

Monolayer MoS2 is a promising material for nanoelectronics; however, the lack of nanofabrication tools and processes has made it very challenging to realize nanometer-scale electronic devices from monolayer MoS2. Here, we demonstrate the fabrication of monolayer MoS2 nanoribbon field-effect transistors as narrow as 30 nm using scanning probe lithography (SPL). The SPL process uses a heated nanometer-scale tip to deposit narrow nanoribbon polymer structures onto monolayer MoS2. The polymer serves as an etch mask during a XeF2 vapor etch, which defines the channel of a field-effect transistor (FET). We fabricated seven devices with a channel width ranging from 30 to 370 nm, and the fabrication process was carefully studied by electronic measurements made at each process step. The nanoribbon devices have a current on/off ratio > 104 and an extrinsic field-effect mobility up to 8.53 cm2/(V s). By comparing a 30 nm wide device with a 60 nm wide device that was fabricated on the same MoS2 flake, we found the narrower device had a smaller mobility, a lower on/off ratio, and a larger subthreshold swing. To our knowledge, this is the first published work that describes a working transistor device from monolayer MoS2 with a channel width smaller than 100 nm.

15.
Sci Rep ; 9(1): 719, 2019 Jan 24.
Artigo em Inglês | MEDLINE | ID: mdl-30679615

RESUMO

This paper describes a nickel-based cellular material, which has the strength of titanium and the density of water. The material's strength arises from size-dependent strengthening of load-bearing nickel struts whose diameter is as small as 17 nm and whose 8 GPa yield strength exceeds that of bulk nickel by up to 4X. The mechanical properties of this material can be controlled by varying the nanometer-scale geometry, with strength varying over the range 90-880 MPa, modulus varying over the range 14-116 GPa, and density varying over the range 880-14500 kg/m3. We refer to this material as a "metallic wood," because it has the high mechanical strength and chemical stability of metal, as well as a density close to that of natural materials such as wood.

17.
Biomed Microdevices ; 19(1): 10, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-28144838

RESUMO

Investigating the growth signatures of single cells will determine how cell growth is regulated and cell size is maintained. The ability to precisely measure such changes and alterations in cell size and cell mass could be important for applications in cancer and drug screening. Here, we measure the mass growth rate of individual benign (MCF-10A), non-invasive (MCF-7), and highly-invasive malignant (MDA-MB-231) breast cancer cells. A micro-patterning technique was employed to allow for the long-term growth of motile cells. Results show mass growth rates at 4.8%, 1.2%, and 2.8% for MCF-10A, MCF-7, and MDA-MB-231, demonstrating that normal cells have a higher mass growth rate than cancerous cells. All the cell lines show an increase in mass change rate indicating that the mass accumulation rate is exponential over a single cell cycle. The growth rates measured with our MEMS sensor are compared with doubling times obtained through conventional bulk analysis techniques, and exhibit excellent agreement.


Assuntos
Neoplasias da Mama/patologia , Microtecnologia/métodos , Linhagem Celular Tumoral , Proliferação de Células , Humanos
18.
J Int Soc Respir Prot ; 34(2): 81-94, 2017 Dec 31.
Artigo em Inglês | MEDLINE | ID: mdl-37333866

RESUMO

As part of development of performance standards, the International Organization for Standardization (ISO) technical committee, ISO/TC 94/SC 15 Respiratory protective devices (RPD), adopted work of breathing (WOB) to evaluate airflow resistance for all designs (classes) of respiratory protective devices. The interests of the National Institute for Occupational Safety and Health's (NIOSH) National Personal Protective Technology Laboratory (NPPTL) are to compare the proposed WOB method and results for current RPD with those for present resistance methods. The objectives here were to assemble a method to meet the ISO SC15 standards, validate operation and conformance, and assess repeatability of WOB measurements for RPD. WOB method implementation and use followed standards ISO 16900-5:2016 and ISO 16900-12:2016. Volume-averaged total work of breathing (WOBT/VT where VT is tidal volume) determined for standard orifices was analyzed for variation and bias. After fabrication and assembly, the method gave preliminary verification orifice results that met ISO requirements and were equivalent to those from other laboratories. Evaluation of additional results from RPD testing showed tidal volume and frequency determined compliance. Appropriate adjustments reduced average absolute bias to 1.7%. Average coefficient of variation for WOBT/VT was 2.3%. Over 97% of results obtained during significant use over time met specifications. WOBT/VT for as-received air-purifying and supplied-air RPD were repeatable (p<0.05). WOBT/VT for unsealed half mask air-purifying RPD was an average of 31% lower compared to sealed. When experimental parameters were appropriately adjusted, the ISO WOB method implemented by NIOSH NPPTL consistently provided ISO-compliant verification WOBT/VT. Results for appropriately sealed RPD were reproducible.

19.
Nanotechnology ; 28(4): 044003, 2017 Jan 27.
Artigo em Inglês | MEDLINE | ID: mdl-28000611

RESUMO

This paper reports the design, fabrication, and characterization of micromechanical devices that can present an engineered contact stiffness to an atomic force microscope (AFM) cantilever tip. These devices allow the contact stiffness between the AFM tip and a substrate to be easily and accurately measured, and can be used to calibrate the cantilever for subsequent mechanical property measurements. The contact stiffness devices are rigid copper disks of diameters 2-18 µm integrated onto a soft silicone substrate. Analytical modeling and finite element simulations predict the elastic response of the devices. Measurements of tip-sample interactions during quasi-static force measurements compare well with modeling simulation, confirming the expected elastic response of the devices, which are shown to have contact stiffness 32-156 N m-1. To demonstrate one application, we use the disk sample to calibrate three resonant modes of a U-shaped AFM cantilever actuated via Lorentz force, at approximately 220, 450, and 1200 kHz. We then use the calibrated cantilever to determine the contact stiffness and elastic modulus of three polymer samples at these modes. The overall approach allows cantilever calibration without prior knowledge of the cantilever geometry or its resonance modes, and could be broadly applied to both static and dynamic measurements that require AFM calibration against a known contact stiffness.

20.
Sci Rep ; 6: 30328, 2016 07 27.
Artigo em Inglês | MEDLINE | ID: mdl-27461899

RESUMO

Water droplet impact on surfaces is a ubiquitous phenomenon in nature and industry, where the time of contact between droplet and surface influences the transfer of mass, momentum and energy. To manipulate and reduce the contact time of impacting droplets, previous publications report tailoring of surface microstructures that influence the droplet - surface interface. Here we show that surface elasticity also affects droplet impact, where a droplet impacting an elastic superhydrophobic surface can lead to a two-fold reduction in contact time compared to equivalent rigid surfaces. Using high speed imaging, we investigated the impact dynamics on elastic nanostructured superhydrophobic substrates having membrane and cantilever designs with stiffness 0.5-7630 N/m. Upon impact, the droplet excites the substrate to oscillate, while during liquid retraction, the substrate imparts vertical momentum back to the droplet with a springboard effect, causing early droplet lift-off with reduced contact time. Through detailed experimental and theoretical analysis, we show that this novel springboarding phenomenon is achieved for a specific range of Weber numbers (We >40) and droplet Froude numbers during spreading (Fr >1). The observation of the substrate elasticity-mediated droplet springboard effect provides new insight into droplet impact physics.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...