Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Aerosol Sci Technol ; 56(1): 63-74, 2021 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-35602286

RESUMO

A sampling system for measuring emissions of nonvolatile particulate matter (nvPM) from aircraft gas turbine engines has been developed to replace the use of smoke number and is used for international regulatory purposes. This sampling system can be up to 35 m in length. The sampling system length in addition to the volatile particle remover (VPR) and other sampling system components lead to substantial particle losses, which are a function of the particle size distribution, ranging from 50 to 90% for particle number concentrations and 10-50% for particle mass concentrations. The particle size distribution is dependent on engine technology, operating point, and fuel composition. Any nvPM emissions measurement bias caused by the sampling system will lead to unrepresentative emissions measurements which limit the method as a universal metric. Hence, a method to estimate size dependent sampling system losses using the system parameters and the measured mass and number concentrations was also developed (SAE 2017; SAE 2019). An assessment of the particle losses in two principal components used in ARP6481 (SAE 2019) was conducted during the VAriable Response In Aircraft nvPM Testing (VARIAnT) 2 campaign. Measurements were made on the 25-meter sample line portion of the system using multiple, well characterized particle sizing instruments to obtain the penetration efficiencies. An agreement of ± 15% was obtained between the measured and the ARP6481 method penetrations for the 25-meter sample line portion of the system. Measurements of VPR penetration efficiency were also made to verify its performance for aviation nvPM number. The research also demonstrated the difficulty of making system loss measurements and substantiates the E-31 decision to predict rather than measure system losses.

2.
Environ Sci Technol ; 45(8): 3415-21, 2011 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-21428391

RESUMO

This paper addresses the need for detailed chemical information on the fine particulate matter (PM) generated by commercial aviation engines. The exhaust plumes of seven turbofan engine models were sampled as part of the three test campaigns of the Aircraft Particle Emissions eXperiment (APEX). In these experiments, continuous measurements of black carbon (BC) and particle surface-bound polycyclic aromatic compounds (PAHs) were conducted. In addition, time-integrated sampling was performed for bulk elemental composition, water-soluble ions, organic and elemental carbon (OC and EC), and trace semivolatile organic compounds (SVOCs). The continuous BC and PAH monitoring showed a characteristic U-shaped curve of the emission index (EI or mass of pollutant/mass of fuel burned) vs fuel flow for the turbofan engines tested. The time-integrated EIs for both elemental composition and water-soluble ions were heavily dominated by sulfur and SO(4)(2-), respectively, with a ∼2.4% median conversion of fuel S(IV) to particle S(VI). The corrected OC and EC emission indices obtained in this study ranged from 37 to 83 mg/kg and 21 to 275 mg/kg, respectively, with the EC/OC ratio ranging from ∼0.3 to 7 depending on engine type and test conditions. Finally, the particle SVOC EIs varied by as much as 2 orders of magnitude with distinct variations in chemical composition observed for different engine types and operating conditions.


Assuntos
Poluentes Atmosféricos/análise , Aeronaves , Material Particulado/análise , Emissões de Veículos/análise , Poluentes Atmosféricos/química , Poluição do Ar/estatística & dados numéricos , Monitoramento Ambiental , Tamanho da Partícula , Material Particulado/química , Hidrocarbonetos Policíclicos Aromáticos/análise , Hidrocarbonetos Policíclicos Aromáticos/química , Fuligem/análise , Fuligem/química , Compostos Orgânicos Voláteis/análise , Compostos Orgânicos Voláteis/química
3.
Environ Sci Technol ; 41(14): 4972-9, 2007 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-17711211

RESUMO

The particulate matter (PM) and gaseous emissions from six diesel school buses were determined over a simulated waiting period typical of schools in the northeastern U.S. Testing was conducted for both continuous idle and hot restart conditions using a suite of on-line particle and gas analyzers installed in the U.S. Environmental Protection Agency's Diesel Emissions Aerosol Laboratory. The specific pollutants measured encompassed total PM-2.5 mass (PM < or = 2.5 microm in aerodynamic diameter), PM-2.5 number concentration, particle size distribution, particle-surface polycyclic aromatic hydrocarbons (PAHs), and a tracer gas (1,1,1,2,3,3,3-heptafluoropropane) in the diluted sample stream. Carbon monoxide (CO), carbon dioxide, nitrogen oxides (NO(x)), total hydrocarbons (THC), oxygen, formaldehyde, and the tracer gas were also measured in the raw exhaust. Results of the study showed little difference in the measured emissions between a 10 min post-restart idle and a 10 min continuous idle with the exception of THC and formaldehyde. However, an emissions pulse was observed during engine restart. A predictive equation was developed from the experimental data, which allows a comparison between continuous idle and hot restart for NO(x), CO, PM2.5, and PAHs and which considers factors such as the restart emissions pulse and periods when the engine is not running. This equation indicates that restart is the preferred operating scenario as long as there is no extended idling after the engine is restarted.


Assuntos
Poluentes Atmosféricos/análise , Veículos Automotores , Emissões de Veículos , Tamanho da Partícula
4.
Inhal Toxicol ; 11(4): 293-307, 1999 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-10380171

RESUMO

Current levels of air pollution particles in American cities can increase human mortality. Both the mechanism of injury and the responsible components are not known. We have postulated that injury following air pollution particle exposure is produced through a generation of oxygen-based free radicals catalyzed by metals present in the particles. As a result of its abundance in the atmosphere, sulfate appears to potentially be the most successful ligand to complex metal cations. We tested the hypothesis that (1) some portion of iron in ambient air pollution particles is present as sulfate and (2) this relationship between iron and sulfate results from the capacity of the latter to function as a ligand to mobilize the metal from the oxide. Concentrations of sulfate and iron in acid extracts of 20 filters (total suspended particles) from Utah were measured using inductively coupled plasma emission spectroscopy. In vitro oxidant generation was also measured using thiobarbituric acid-reactive products of deoxyribose. There were significant correlations between sulfate content, iron concentrations, and oxidant generation. Agitation of calcium sulfate with iron(III) oxide produced concentrations of water-soluble, catalytically active iron. We conclude that some portion of iron in the atmosphere is present as a sulfate. This relationship between sulfate and iron concentrations is likely the product of SO42- functioning as a ligand for the meal after its mobilization from an oxide by photoreduction. There were also associations between sulfate content, iron concentrations, and oxidant generation. However, sulfates had no capacity to support electron transport unless they were present with iron.


Assuntos
Poluentes Atmosféricos/análise , Ferro/análise , Sulfatos/análise , Nefelometria e Turbidimetria , Espectrometria por Raios X , Saúde da População Urbana , Utah
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...