Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Plast Reconstr Surg ; 2023 Sep 19.
Artigo em Inglês | MEDLINE | ID: mdl-37734110

RESUMO

BACKGROUND: Textured implants were developed with the goal of reducing rates of capsular contracture and preventing implant malposition (eg., malrotation). Recent evidence has questioned whether textured implants are as resistant to malrotation as previously reported. METHODS: Women presenting to a single healthcare system for removal of textured implants were prospectively enrolled in the study from September 2019 to July of 2022. Patients who underwent removal of an anatomic, textured implant in the operating room were included in the study, while those who did not undergo implant removal, or were found to have a smooth implant, or a round, textured implant were excluded. The degree of implant rotation upon removal of the implant was measured intra-operatively. Implant specific factors, as well as patient demographics, clinical factors, and operative characteristics were collected. RESULTS: A total of 51 patients (80 implants) were included in the study. 45% of implants were malrotated (rotated >30 degrees) and the median degree of rotation was 30. Having more than one previous revision of the breast pocket was predictive of implant rotation (42 degrees) on multivariate linear regression analysis. Patients who presented with a complaint of "aesthetic dissatisfaction" had 2.89 increased odds of having an implant rotated > 30 degrees. CONCLUSION: Our study found a high rate of malrotation of textured, shaped implants upon explantation.

2.
Ann Plast Surg ; 91(2): 307-312, 2023 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-37489974

RESUMO

ABSTRACT: Three-dimensional (3D) printing continues to revolutionize the field of plastic surgery, allowing surgeons to adapt to the needs of individual patients and innovate, plan, or refine operative techniques. The utility of this manufacturing modality spans from surgical planning, medical education, and effective patient communication to tissue engineering and device prototyping and has valuable implications in every facet of plastic surgery. Three-dimensional printing is more accessible than ever to the surgical community, regardless of previous background in engineering or biotechnology. As such, the onus falls on the surgeon-innovator to have a functional understanding of the fundamental pipeline and processes in actualizing such innovation. We review the broad range of reported uses for 3D printing in plastic surgery, the process from conceptualization to production, and the considerations a physician must make when using 3D printing for clinical applications. We additionally discuss the role of computer-assisted design and manufacturing and virtual and augmented reality, as well as the ability to digitally modify devices using this software. Finally, a discussion of 3D printing logistics, printer types, and materials is included. With innovation and problem solving comprising key tenets of plastic surgery, 3D printing can be a vital tool in the surgeon's intellectual and digital arsenal to span the gap between concept and reality.


Assuntos
Procedimentos de Cirurgia Plástica , Cirurgiões , Cirurgia Plástica , Humanos , Comércio , Desenho Assistido por Computador
3.
J Craniofac Surg ; 34(3): e331-e333, 2023 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-36882919

RESUMO

Cranioplasty is a well-described technique used to restore the contour and function of calvarial defects using various alloplastic implants and autologous bone grafts. However, unsatisfactory esthetic outcomes after cranioplasty are frequently reported, specifically postoperative temporal hollowing. Temporal hollowing arises when the temporalis is inadequately resuspended after cranioplasty. Several methods to prevent this complication have been described with variable degrees of esthetic improvement, but no single method has proven superior. Herein the authors present a case report demonstrating a novel approach to resuspending the temporalis that incorporates holes in the custom cranial implant to allow for resuspension of the temporalis through suture fixation to the implant.


Assuntos
Implantes Dentários , Estética Dentária , Humanos , Crânio/cirurgia , Músculo Temporal/transplante , Suturas
4.
SAGE Open Med ; 10: 20503121221129921, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36451777

RESUMO

The purpose of this study was to use the Altmetric Attention Score to determine the 50 most impactful medial ulnar collateral ligament articles in online media and compare their characteristics to the most-cited medial ulnar collateral ligament articles in the scientific literature. The Altmetric database was queried to identify all published articles about the medial ulnar collateral ligament, and this list was stratified by the Altmetric Attention Score to identify the 50 highest scoring articles. Several data elements were extracted, including article topic, article type, journal name, and the number of online mentions on Facebook, Twitter, news, and other platforms. Each article's geographic origin was determined based on the institutional affiliation of the first author. Our index search yielded 1283 articles published between 1987 and 2020, from which the 50 articles with the highest Altmetric Attention Scores were included for analysis. Altmetric Attention Scores of the top 50 medial ulnar collateral ligament articles ranged from 20 to 482 (median: 32, interquartile range: 20-62). The most common article type was original research (72%), and the most common topic was epidemiology/risk factors (26%). A majority of studies were Level 3 (36%) or Level 4 evidence (36%). Of the top 50 medial ulnar collateral ligament articles, 94% originated from the United States. A few articles had a high Altmetric Attention Score, suggesting that medial ulnar collateral ligament research does not generate consistently high online attention. The lack of Level 1 studies suggests the need for high-level studies on the medial ulnar collateral ligament. Most studies originated in the United States and were published in the American Orthopaedic Society for Sports Medicine-affiliated journals. The medial ulnar collateral ligament articles included in this study differed substantially from a previous report of the most-cited medial ulnar collateral ligament articles in the literature, suggesting that alternative metrics add a unique dimension to understanding the overall impact of published research on the medial ulnar collateral ligament.

5.
J Orthop ; 33: 95-99, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35899098

RESUMO

Purpose: The purpose of this study was to compare surgical outcomes in patients who underwent ACL reconstruction, with and without internal bracing, at 1-3, 4-7, and 8-12 months of postoperative physical therapy. Previous studies show that ACL reconstruction with internal bracing allows earlier and more aggressive rehabilitation. Therefore, it was hypothesized that patients with internal bracing would display superior surgical recovery compared to ACL reconstruction alone after adjusting for length of physical therapy.1, 2, 3. Methods: Patients who underwent ACL reconstruction and had a minimum two-year follow-up were included. Demographics including age, gender, use of internal bracing, and pre-operative level of activity were collected. Patient-reported outcomes were assessed using KOOS scores. Results: 46 patients underwent ACL reconstruction between January 2013 and December 2015. The mean age was 31.53 ± 8.37 years. Patients who received ACL reconstruction with internal bracing reported similar improvement in KOOS scores (mean = 42.82 ± 15.44; median = 46.39 [34.52-51.80]) compared to ACL reconstruction alone (mean = 38.18 ± 19.91; median = 40.17 [29.49-53.90]) (p = 0.475). Patients who received ACL reconstruction with internal bracing reported comparable improvement to ACL reconstruction alone at 0-3 months (Internal bracing: mean = 35.39 ± 15.26, median = 40.45 [26.49-47.73]; No internal bracing: mean = 42.51 ± 12.33, median = 39.32 [35.69-52.94], p = 0.4113), 4-7 months (Internal bracing: 41.96 ± 14.49, 45.55 [33.94-52.68]; No internal bracing: 30.64 ± 32.29, 41.65 [26.17-46.12], p = 0.7491) and 8+ months groups (Internal bracing: 63.36 ± 13.06, 63.36 [58.74-67.98]; No internal bracing: 47.05 ± 10.14, 47.05 [43.46-50.63]) (p = 0.6985). Conclusion: This study demonstrates no statistical difference in functional outcome scores when comparing patients with internally braced ACL reconstruction compared to standard reconstruction. Therefore, the increased structural support provided by use of internal bracing in ACL reconstruction does not afford to quicker improvement in patient-reported recovery.

6.
J Shoulder Elbow Surg ; 31(11): 2274-2280, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35562036

RESUMO

BACKGROUND: Although preoperative function and range of motion (ROM) are determinants of postoperative outcome following reverse shoulder arthroplasty (RSA), there is limited data on the influence of preoperative rotator cuff status. The purpose of this study was to evaluate the relationship between preoperative rotator cuff physiologic cross-sectional area (PCSA) and strength on postoperative RSA outcome. METHODS: A retrospective review was conducted on 53 primary RSAs from a multicenter database performed between 2015 and 2019 using a 135° humeral neck-shaft angle. Preoperative magnetic resonance imaging and computed tomographic scans were used to assess the PCSA of the subscapularis, supraspinatus, infraspinatus, and teres minor. American Shoulder and Elbow Surgeons Standardized Shoulder Assessment Form (ASES) scores, ROM, and strength were measured preoperatively and at a minimum of 2 years postoperatively. Correlation coefficients were used to determine the relationship between variables. RESULTS: There were no significant correlations between preoperative PCSA of any rotator cuff muscles and postoperative ASES scores. Preoperative subscapularis PCSA positively correlated with change in belly press (BP) strength following RSA (⍴ = 0.37, P = .006). Preoperative abduction strength was significantly correlated with postoperative abduction strength (⍴ = 0.297, P = .006). Preoperative external rotation (ER) strength was significantly correlated with postoperative ER (⍴ = 0.378, P = .005) and abduction (⍴ = 0.304; P = .032) strength. Preoperative BP strength negatively correlated with postoperative ASES (⍴ = -0.283, P = .042) but positively correlated with postoperative BP (⍴ = 0.411, P = .001) and abduction (⍴ = 0.367, P = .009) strength. CONCLUSION: With the use of a 135° humeral implant, there is limited correlation between preoperative PCSA and postoperative outcomes 2 years following RSA; the only significant correlation was between preoperative subscapularis PCSA and postoperative BP strength. Preoperative strength is positively correlated with postoperative strength but not ROM or ASES scores.


Assuntos
Artroplastia do Ombro , Lesões do Manguito Rotador , Humanos , Manguito Rotador/patologia , Resultado do Tratamento , Artroplastia
7.
Plast Reconstr Surg Glob Open ; 10(4): e4024, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35450262

RESUMO

Background: Traditional citation-based metrics do not capture the dissemination of upper extremity lymphedema (UEL) research that occurs online and in mainstream media. There is limited literature reporting the most impactful UEL articles based on citation rate and/or online mentions. We sought to use the Altmetric Attention Score (AAS) to determine the most impactful UEL articles in online media and to report trends in the diagnosis, treatment, and prevention of complications. Methods: The Altmetric database was queried to identify all published articles regarding the management, diagnosis, and prevention of complications seen in the setting of UEL. Extracted data points included article topic and type, journal, and number of online mentions on several platforms. Results: Our index search yielded 638 studies published between 2000 and 2021. Fifty articles with the highest AAS scores were included for analysis. The median AAS was 27.5, but the top four articles had AAS scores that were substantially higher (AAS ≥ 334) than all other studies. Of the top 50 articles, 68% (34/50) were original research. Of those, 23.5% (8/34) were randomized control trials. The most common article topic was the treatment of UEL (36%; 18/50) followed by diagnostic methods of UEL (30%; 15/50). There were a total of 1156 Twitter mentions (median:14) for the top 50 articles. Of all media platforms, news mentions correlated most strongly with AAS (R2 = 0.99, P < 0.001). Conclusions: Our findings suggest that alternative metrics measure distinct components of article impact and add an important dimension to understanding the overall impact of published research on UEL.

8.
JSES Rev Rep Tech ; 2(2): 117-124, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-37587964

RESUMO

Reverse shoulder arthroplasty (RSA) leads to improvement in pain and function with a durable outcome in most cases. While improvement in forward flexion and to a lesser degree external rotation is predictably seen after RSA, restoration of internal rotation (IR) is much less predictable. The purpose of this review was to provide a narrative of the modifiable factors, including prosthetic design and surgical factors, that may impact postoperative IR after RSA. Overall, the available data suggest that postoperative IR is improved with a lower humeral neck shaft angle and lateralization of the glenoid. Decreasing humeral retroversion to 20° or less improves IR at the cost of decreasing active external rotation. Increasing glenosphere diameter improves IR but often within the setting of additional variables. The association between subscapularis repair is less clear but overall suggests that IR is improved postoperatively when it is repaired.

9.
Adv Wound Care (New Rochelle) ; 11(12): 650-656, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-34714156

RESUMO

Objective: To evaluate the role of disease-modifying antirheumatic drugs (DMARDs) on wound healing outcomes of patients with autoimmune disease at our tertiary wound care center. Approach: Retrospective review of patients presenting to our wound care center between 2014 and 2018 with both chronic wounds and a history of inflammatory disease. Patient demographics, comorbid conditions, and progression to complete wound healing were compared between those taking DMARDs or not at the time of wound onset. The study adheres to the STROBE statement. Results: Fifty-eight patients with a total of 296 wounds were retrospectively reviewed. Patients were taking at least one DMARD at wound onset in 217 (73.3%) of these wounds. The average number of DMARDs at wound onset was 1.5 (standard deviation 1.2). Two hundred ten wounds progressed to heal (70.9%), with a median time to healing of 229.5 days (interquartile range 71.0-490.0). Of the 210 wounds that healed, patients taking at least one DMARD had a significantly shorter time to healing relative to patients who were not on any DMARDs (median 190.5 days vs. 340.0 days, p = 0.0156). Innovation: Characterizing wound healing outcomes at a tertiary hospital with a dedicated wound care center and analyzing the role of DMARDs in wound healing progression. Conclusions: The median time to healing in the studied cohort was 229.5 days, which is much longer than the healing time for noninfected diabetic foot ulcers at our institution. These findings highlight the wound healing challenges posed by underlying autoimmune disease.10.


Assuntos
Antirreumáticos , Doenças Autoimunes , Pé Diabético , Antirreumáticos/uso terapêutico , Doenças Autoimunes/tratamento farmacológico , Humanos , Estudos Retrospectivos , Cicatrização
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...