1.
Semin Fetal Neonatal Med ; 28(5): 101486, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-38030439

RESUMO

Endotracheal intubation is a life-saving procedure for many newborns. Historically, it has been achieved by obtaining an airway view through the mouth via direct laryngoscopy. It is a skill that takes time and practice to achieve proficiency. Increasing evidence for the benefit of videolaryngoscopy in adults and the new development of technology has allowed videolaryngoscopy to become a reality in neonatal care. Studies have examined its use as both a technique to improve intubation safety and success, and as a training tool for those learning the skill in this vulnerable population. We present the current evidence for videolaryngoscopy in neonates in different settings where intubation may be required, in addition to exploring the challenges and practicalities of implementing this technique into clinical practice.


Assuntos
Laringoscópios , Laringoscopia , Adulto , Recém-Nascido , Humanos , Laringoscopia/educação , Laringoscopia/métodos , Intubação Intratraqueal/métodos
4.
J Pediatr ; 236: 189-193.e2, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33940014

RESUMO

OBJECTIVE: To assess the first attempt neonatal intubation success rates of pediatric trainees following the implementation of an evidence-based training package. STUDY DESIGN: Data collection was undertaken from February, 1 2017, to January 31, 2018, to ascertain baseline preimplementation intubation success rates. An intubation training package, which included the use of videolaryngoscopy, preprocedure pause, and standardized instruction during the procedure, was introduced. Data on all subsequent intubations were collected prospectively from May 1, 2018, to April 30, 2020. RESULTS: Preimplementation baseline data over a 1-year period demonstrated overall first attempt intubation success rate of junior trainees to be 37% (33/89). After implementation of the training package, 290 intubations were analyzed over a 2-year period. The overall success rate was 67% (194/290); 61% (117/192) for junior trainees and 79% (77/98) for senior clinicians. Three or more attempts were required for 13% of intubations (38/290). During the study period, the overall number of intubations being carried out decreased. Intubations with the videolaryngoscope had higher success rates for all tiers of clinician, most marked in the junior tiers. CONCLUSIONS: The introduction of a standardized intubation training package, along with videolaryngoscopy, improved trainee intubation success rates.


Assuntos
Competência Clínica , Cuidados Críticos , Intubação Intratraqueal , Laringoscopia/educação , Pediatria/educação , Aprendizagem Baseada em Problemas/organização & administração , Humanos , Recém-Nascido , Internato e Residência , Gravação em Vídeo
5.
Arch Dis Child Fetal Neonatal Ed ; 106(2): 168-171, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32963087

RESUMO

INTRODUCTION: Neonatal intubation is a challenging skill to acquire. A randomised controlled trial (RCT) found junior trainees had higher intubation success rates if their supervisor shared their airway view on a videolaryngoscope screen compared with intubations where the supervisor could not see the videolaryngoscope screen. The intubations in the trial were supervised by a group of experienced neonatologists who developed an intubation teaching package that aimed to be informative, consistent and supportive. We surveyed the trainees to assess their experiences of the intubation attempts. METHODS: Trainees participating in the RCT completed questionnaires anonymously after each intubation attempt. Questionnaires used 5-point Likert scales and free comment sections. Quantitative analysis was performed using descriptive statistics. In a qualitative analysis, free comments were coded to identify central recurring themes. RESULTS: Two hundred and six questionnaires were completed by 36 trainees. The majority reported that the guidance received during intubation was helpful, the postprocedure feedback was educational and their confidence levels were increased. Trainees appreciated a controlled environment and calm, consistent guidance. They found intubations in the delivery room, those involving unstable infants, large audiences and parental presence more stressful. Responses were positive whether the videolaryngoscope screen was visible or covered, emphasising the importance of consistent guidance. Overall, 16% of intubations were reported as intimidating. CONCLUSION: The shared airway view offered by videolaryngoscopy was well received. In addition, taking measures to control the setting, with standardised guidance and feedback, improved confidence and created a more positive learning experience.


Assuntos
Intubação Intratraqueal/métodos , Laringoscopia/educação , Laringoscopia/métodos , Competência Clínica , Humanos , Recém-Nascido
6.
Arch Dis Child Fetal Neonatal Ed ; 106(2): 172-177, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32928897

RESUMO

OBJECTIVE: To evaluate the parent and staff experience of a secure video messaging service as a component of neonatal care. DESIGN: Multicentre evaluation incorporating quantitative and qualitative items. SETTING: Level II and level III UK neonatal units. POPULATION: Families of neonatal inpatients and neonatal staff. INTERVENTION: Use of a secure, cloud-based asynchronous video messaging service to send short messages from neonatal staff to families. Evaluation undertaken July-November 2019. MAIN OUTCOME MEASURES: Parental experience, including anxiety, involvement in care, relationships between parents and staff, and breastmilk expression. RESULTS: In pre-implementation surveys (n=41), families reported high levels of stress and anxiety and were receptive to use of the service. In post-implementation surveys (n=42), 88% perceived a benefit of the service on their neonatal experience. Families rated a positive impact of the service on anxiety, sleep, family involvement and relationships with staff. Qualitative responses indicated enhanced emotional closeness, increased involvement in care and a positive effect on breastmilk expression. Seventy-seven post-implementation staff surveys were also collected. Staff rated the service as easy to use, with minimal impact on workload. Seventy-one percent (n=55) felt the service had a positive impact on relationships with families. Staff identified the need to manage parental expectations in relation to the number of videos that could be sent. CONCLUSIONS: Asynchronous video messaging improves parental experience, emotional closeness to their baby and builds supportive relationships between families and staff. Asynchronous video supports models of family integrated care and can mitigate family separation, which could be particularly relevant during the COVID-19 pandemic.


Assuntos
COVID-19/psicologia , Terapia Intensiva Neonatal/psicologia , Pais/psicologia , Envio de Mensagens de Texto/estatística & dados numéricos , Gravação em Vídeo/estatística & dados numéricos , Feminino , Humanos , Recém-Nascido , Unidades de Terapia Intensiva Neonatal/organização & administração , Masculino
7.
Arch Dis Child Fetal Neonatal Ed ; 105(1): 94-97, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30606750

RESUMO

Neonatal intubation is an essential but difficult skill to learn. Videolaryngoscopy allows the airway view to be shared by the intubator and supervisor and improves intubation success. Ideally, a videolaryngoscope (VL) should be usable as a conventional laryngoscope (CL). The aims of this report were to describe differences in the shape of currently available CL and VL blades and to compare the direct airway view obtainable on a neonatal manikin with different laryngoscope blades.Three main differences were observed; compared with CL, the VL blades have a reduced vertical height, a curved tip and curved body. The direct airway view obtained by the VL is narrower than that obtained with the CL, although the corresponding view on the VL screen is maintained.Minor adaptation of intubation technique may be required when using a VL. Modifying VL blades to reduce these differences may improve their usefulness as an intubation training tool.


Assuntos
Laringoscópios , Laringoscopia/instrumentação , Gravação em Vídeo , Desenho de Equipamento , Humanos , Recém-Nascido , Intubação Intratraqueal , Laringoscopia/educação , Manequins
8.
Oxf Med Case Reports ; 2019(7): omz061, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31312461

RESUMO

Sickle cell disease (SCD) is the most common inherited haemoglobinopathy wordwide, with the highest prevalence in sub-Saharan Africa. Due to the lack of national strategies and scarcity of diagnostic tools in resource-limited settings, the disease may be significantly underdiagnosed. We carried out a 6-month retrospective review of paediatric admissions in a district hospital in northern Sierra Leone. Our aim was to identify patients with severe anaemia, defined as Hb < 7 g/dl, and further analyse the records of those tested for SCD. Of the 273 patients identified, only 24.5% had had an Emmel test, among which 34.3% were positive. Furthermore, only 17% of patients with a positive Emmel test were discharged on prophylactic antibiotics. Our study shows that increased awareness of SCD symptoms is required in high-burden areas without established screening programmes. In addition, the creation or strengthening of follow-up programmes for SCD patients is essential for disease control.