Phys Med Biol ; 69(9)2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38537310

RESUMO

Automated assessment of noise level in clinical computed tomography (CT) images is a crucial technique for evaluating and ensuring the quality of these images. There are various factors that can impact CT image noise, such as statistical noise, electronic noise, structure noise, texture noise, artifact noise, etc. In this study, a method was developed to measure the global noise index (GNI) in clinical CT scans due to the fluctuation of x-ray quanta. Initially, a noise map is generated by sliding a 10 × 10 pixel for calculating Hounsfield unit (HU) standard deviation and the noise map is further combined with the gradient magnitude map. By employing Boolean operation, pixels with high gradients are excluded from the noise histogram generated with the noise map. By comparing the shape of the noise histogram from this method with Christianson's tissue-type global noise measurement algorithm, it was observed that the noise histogram computed in anthropomorphic phantoms had a similar shape with a close GNI value. In patient CT images, excluding the HU deviation due the structure change demonstrated to have consistent GNI values across the entire CT scan range with high heterogeneous tissue compared to the GNI values using Christianson's tissue-type method. The proposed GNI was evaluated in phantom scans and was found to be capable of comparing scan protocols between different scanners. The variation of GNI when using different reconstruction kernels in clinical CT images demonstrated a similar relationship between noise level and kernel sharpness as observed in uniform phantom: sharper kernel resulted in noisier images. This indicated that GNI was a suitable index for estimating the noise level in clinical CT images with either a smooth or grainy appearance. The study's results suggested that the algorithm can be effectively utilized to screen the noise level for a better CT image quality control.


Assuntos
Algoritmos , Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/métodos , Imagens de Fantasmas , Controle de Qualidade , Artefatos , Doses de Radiação , Processamento de Imagem Assistida por Computador/métodos
2.
Med Phys ; 51(3): 2306-2310, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37956259

RESUMO

BACKGROUND: Glass 90 Y microspheres are produced with known radionuclide impurities. These impurities are not independently monitored. Clinical instruments, including ionization chamber dose calibrators and positron emmission tomography (PET) cameras, can be much more sensitive in detecting signals from these impurities than to signals from 90 Y itself. PURPOSE: The "typical" levels of 90 Y impurities have been studied to assess their impact on dosimetry during internal implantation, and for the management of waste. However, unaccounted-for decay spectra of impurities can also have an impact on dose calibrator and PET readings. Thus, even what might be considered negligibly small impurity fractions, can in principle cause substantial overestimates of the amount of 90 Y activity present in a sample. To our knowledge, quantitative effects of radionuclide impurities in glass microspheres on activity measurements have not been documented in the field. As activity quantitation for dosimetry and its correlations with outcome becomes more prevalent, the effects of impurities on measurements may remain unaccounted for in dosimetry studies. METHODS: In this letter, we review theoretical and physical considerations that will result in asymmetric errors in quantitation from 90 Y impurities and estimate their typical and potential impact on clinical utilization. Among the common impurities 88 Y is of particular concern for its impact on 90 Y dose measurements because of its decay characteristics, along with other isotopes 91 Y and 46 Sc which can also impact measurements. RESULTS: The typical level of 88 Y impurities reported by the manufacturer should only cause small errors in dose calibrator and PET measurements made within the 12-day label-specified use-by period, up to 2.0% and 1.6%, respectively. However, the product specification max allowable impurity levels, specified by the manufacturer, leave open the potential for much greater bias from within the 12-day use-by period, potentially as high as 13.2% for dose calibrator measurements and 10.6% for PET from the 88 Y impurities. CONCLUSIONS: While typical levels of impurities appear to have acceptable impact on patient absorbed dose, it should be noted that they can have adverse effects on 90 Y radioactivity measurements. Furthermore, there is currently minimal independent verification and/or monitoring of impurity levels within the field.


Assuntos
Embolização Terapêutica , Neoplasias Hepáticas , Humanos , Microesferas , Radioisótopos de Ítrio , Radiometria/métodos , Tomografia Computadorizada de Emissão , Vidro
3.
Cardiovasc Intervent Radiol ; 46(7): 911-920, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37268735

RESUMO

PURPOSE: This study aimed to evaluate the optimal method of segmentation of colorectal liver metastasis (CLM) on immediate pre-ablation PET scans and assess the prognostic value of quantitative pre-ablation PET parameters with regards to local tumor control. A secondary objective was to correlate the target tumor size estimation by PET methods with the tumor measurements on anatomical imaging. METHODOLOGY: A prospectively accrued cohort of 55 CLMs (46 patients) treated with real-time 18F-FDG-PET/CT-guided percutaneous microwave ablation was followed-up for a median of 10.8 months (interquartile: 5.5-20.2). Total lesion glycolysis (TLG) and metabolic tumor volume (MTV) values of each CLM were derived from pre-ablation 18F-FDG-PET with gradient and threshold PET segmentation methodologies. The event was defined as local tumor progression (LTP). Time-dependent receiver operating characteristic (ROC) curve analyses were used to assess area under the curves (AUCs). Intraclass correlation (ICC) and 95.0% confidence interval (CI) were performed to measure the linear relationships between the continuous variables. RESULTS: AUCs for prediction of LTP obtained from time-dependent ROC analysis for the gradient technique were higher in comparison to the threshold methodologies (AUCs for TLG and volume were: 0.790 and 0.807, respectively). ICC between PET gradient-based and anatomical measurements were higher in comparison to threshold methodologies (ICC for the longest diameter: 733 (95.0% CI 0.538-0.846), ICC for the shortest diameter: .747 (95.0% CI 0.546-0.859), p-values < 0.001). CONCLUSIONS: The gradient-based technique had a higher AUC for prediction of LTP after microwave ablation of CLM and showed the highest correlation with anatomical imaging tumor measurements.


Assuntos
Neoplasias Colorretais , Neoplasias Hepáticas , Humanos , Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Micro-Ondas/uso terapêutico , Tomografia por Emissão de Pósitrons , Prognóstico , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia , Neoplasias Colorretais/patologia , Carga Tumoral , Estudos Retrospectivos , Compostos Radiofarmacêuticos
4.
J Vasc Interv Radiol ; 34(9): 1556-1564.e4, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37201655

RESUMO

PURPOSE: To evaluate the yttrium-90 (90Y) activity distribution in biopsy tissue samples of the treated liver to quantify the dose with higher spatial resolution than positron emission tomography (PET) for accurate investigation of correlations with microscopic biological effects and to evaluate the radiation safety of this procedure. MATERIALS AND METHODS: Eighty-six core biopsy specimens were obtained from 18 colorectal liver metastases (CLMs) immediately after 90Y transarterial radioembolization (TARE) with either resin or glass microspheres using real-time 90Y PET/CT guidance in 17 patients. A high-resolution micro-computed tomography (micro-CT) scanner was used to image the microspheres in part of the specimens and allow quantification of 90Y activity directly or by calibrating autoradiography (ARG) images. The mean doses to the specimens were derived from the measured specimens' activity concentrations and from the PET/CT scan at the location of the biopsy needle tip for all cases. Staff exposures were monitored. RESULTS: The mean measured 90Y activity concentration in the CLM specimens at time of infusion was 2.4 ± 4.0 MBq/mL. The biopsies revealed higher activity heterogeneity than PET. Radiation exposure to the interventional radiologists during post-TARE biopsy procedures was minimal. CONCLUSIONS: Counting the microspheres and measuring the activity in biopsy specimens obtained after TARE are safe and feasible and can be used to determine the administered activity and its distribution in the treated and biopsied liver tissue with high spatial resolution. Complementing 90Y PET/CT imaging with this approach promises to yield more accurate direct correlation of histopathological changes and absorbed dose in the examined specimens.


Assuntos
Neoplasias Colorretais , Embolização Terapêutica , Neoplasias Hepáticas , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Microtomografia por Raio-X , Autorradiografia , Tomografia por Emissão de Pósitrons/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/tratamento farmacológico , Radioisótopos de Ítrio/efeitos adversos , Embolização Terapêutica/efeitos adversos , Embolização Terapêutica/métodos , Biópsia Guiada por Imagem , Microesferas
5.
Cancers (Basel) ; 14(24)2022 Dec 19.
Artigo em Inglês | MEDLINE | ID: mdl-36551738

RESUMO

BACKGROUND: Real-time split-dose PET can identify the targeted colorectal liver metastasis (CLM) and eliminate the need for repeated contrast administration before and during thermal ablation (TA). This study aimed to assess the added value of pre-ablation real-time split-dose PET when combined with non-contract CT in the detection of CLM for ablation and the evaluation of the ablation zone and margins. METHODS: A total of 190 CLMs/125 participants from two IRB-approved prospective clinical trials using PET/CT-guided TA were analyzed. Based on detection on pre-TA imaging, CLMs were categorized as detectable, non-detectable, and of poor conspicuity on CT alone, and detectable, non-detectable, and low FDG-avidity on PET/CT after the initial dose. Ablation margins around the targeted CLM were evaluated using a 3D volumetric approach. RESULTS: We found that 129/190 (67.9%) CLMs were detectable on CT alone, and 61/190 CLMs (32.1%) were undetectable or of poor conspicuity, not allowing accurate depiction and targeting by CT alone. Thus, the theoretical 5- and 10-mm margins could not be defined in these tumors (32.1%) using CT alone. When TA intraprocedural PET/CT images are obtained and inspected (fused PET/CT), only 4 CLM (2.1%) remained undetectable or had a low FDG avidity. CONCLUSIONS: The addition of PET to non-contrast CT improved CLM detection for ablation targeting, margin assessments, and continuous depiction of the FDG avid CLMs during the ablation without the need for multiple intravenous contrast injections pre- and intra-procedurally.

6.
Q J Nucl Med Mol Imaging ; 65(1): 20-31, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33494585

RESUMO

During the past 10 years, performing real-time molecular imaging with positron emission tomography (PET) in combination with computed tomography (CT) during interventional procedures has undergone rapid development. Keeping in mind the interest of the nuclear medicine readers, an update is provided of the current workflows using real-time PET/CT in percutaneous biopsies and tumor ablations. The clinical utility of PET/CT guided biopsies in cancer patients with lung, liver, lymphoma, and bone tumors are reviewed. Several technological developments, including the introduction of new PET tracers and robotic arms as well as opportunities provided through acquiring radioactive biopsy specimens are briefly reviewed.


Assuntos
Fluordesoxiglucose F18/química , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/normas , Compostos Radiofarmacêuticos/química , Neoplasias Ósseas , Relação Dose-Resposta à Radiação , Fluordesoxiglucose F18/metabolismo , Humanos , Fígado , Pulmão , Linfoma , Medicina Nuclear , Compostos Radiofarmacêuticos/metabolismo , Tomografia Computadorizada por Raios X
8.
Radiology ; 295(3): 606-615, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32255416

RESUMO

Background Current measurements of multiple myeloma disease burden are suboptimal. Daratumumab is a monoclonal antibody that targets CD38, an antigen expressed on nearly all myeloma cells. Purpose To demonstrate preclinical and first-in-human application of an antibody composed of the native daratumumab labeled with the positron-emitting radionuclide zirconium 89 (89Zr) through the chelator deferoxamine (DFO), or 89Zr-DFO-daratumumab, for immunologic PET imaging of multiple myeloma. Materials and Methods 89Zr-DFO-daratumumab was synthesized by conjugating 89Zr to daratumumab with DFO. A murine xenograft model using CD38-positive OPM2 multiple myeloma cells was used to evaluate CD38-specificity of 89Zr-DFO-daratumumab. Following successful preclinical imaging, a prospective phase I study of 10 patients with multiple myeloma was performed. Study participants received 74 MBq (2 mCi) of intravenous 89Zr-DFO-daratumumab. Each participant underwent four PET/CT scans over the next 8 days, as well as blood chemistry and whole-body counts, to determine safety, tracer biodistribution, pharmacokinetics, and radiation dosimetry. Because 89Zr has a half-life of 78 hours, only a single administration of tracer was needed to obtain all four PET/CT scans. Results 89Zr-DFO-daratumumab was synthesized with radiochemical purity greater than 99%. In the murine model, substantial bone marrow uptake was seen in OPM2 mice but not in healthy mice, consistent with CD38-targeted imaging of OPM2 multiple myeloma cells. In humans, 89Zr-DFO-daratumumab was safe and demonstrated acceptable dosimetry. 89Zr-DFO-daratumumab uptake was visualized at PET in sites of osseous myeloma. Conclusion These data demonstrate successful CD38-targeted immunologic PET imaging of multiple myeloma in a murine model and in humans. © RSNA, 2020 Online supplemental material is available for this article.


Assuntos
ADP-Ribosil Ciclase 1 , Neoplasias Ósseas/diagnóstico por imagem , Modelos Animais de Doenças , Glicoproteínas de Membrana , Mieloma Múltiplo/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Animais , Anticorpos Monoclonais , Desferroxamina , Xenoenxertos , Humanos , Estudos Prospectivos , Sensibilidade e Especificidade , Carga Tumoral , Zircônio
9.
Med Phys ; 45(5): 2179-2185, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29480927

RESUMO

PURPOSE: Genomic profiling of biopsied tissue is the basis for precision cancer therapy. However, biopsied materials may not contain sufficient amounts of tumor deoxyribonucleonic acid needed for the analysis. We propose a method to determine the adequacy of specimens for performing genomic profiling by quantifying their metabolic activity. METHODS: We estimated the average density of tumor cells in biopsy specimens needed to successfully perform genomic analysis following the Memorial Sloan Kettering Integrated Mutation Profiling of Actionable Cancer Targets (MSK-IMPACT) protocol from the minimum amount of deoxyribonucleonic acid needed and the volume of tissue typically used for analysis. The average 18 F-FDG uptake per cell was assessed by incubating HT-29 adenocarcinoma tumor cells in 18 F-FDG containing solution and then measuring their activity with a scintillation well counter. Consequently, we evaluated the response of two devices around the minimum expected activities which would indicate genomic profiling adequacy of biopsy specimens obtained under 18 F-FDG PET/CT guidance. Surrogate samples obtained using 18G core needle biopsies of gels containing either 18 F-FDG-loaded cells in the expected concentrations or the corresponding activity were measured using autoradiography and a scintillation well counter. Autoradiography was performed using a CCD-based device with real-time image display as well as with digital autoradiography imaging plates following a 30-min off-line protocol for specimen activity determination against previously established calibration. RESULTS: Cell incubation experiments and estimates obtained from quantitative autoradiography of biopsy specimens (QABS) indicate that specimens acquired under 18 F-FDG PET/CT guidance that contained the minimum amount of cells needed for genomic profiling would have an average activity concentration in the range of about 3 to about 9 kBq/mL. When exposed to specimens with similar activity concentration, both a CCD-based autoradiography device and a scintillation well counter produced signals with sufficient signal-to-background ratio for specimen genomic adequacy identification in less than 10 min, which is short enough to allow procedure guidance. CONCLUSION: Scintillation well counter measurements and CCD-based autoradiography have adequate sensitivity to detect the tumor burden needed for genomic profiling during 18 F-FDG PET/CT-guided 18G core needle biopsies of liver adenocarcinoma metastases.


Assuntos
Autorradiografia/instrumentação , Fluordesoxiglucose F18 , Genômica , Biópsia Guiada por Imagem/instrumentação , Contagem de Cintilação/instrumentação , Transporte Biológico , Estudos de Viabilidade , Fluordesoxiglucose F18/metabolismo , Células HT29 , Humanos , Injeções , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada
10.
Med Phys ; 44(8): 4098-4111, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28474819

RESUMO

PURPOSE: The aim of this paper is to define the requirements and describe the design and implementation of a standard benchmark tool for evaluation and validation of PET-auto-segmentation (PET-AS) algorithms. This work follows the recommendations of Task Group 211 (TG211) appointed by the American Association of Physicists in Medicine (AAPM). METHODS: The recommendations published in the AAPM TG211 report were used to derive a set of required features and to guide the design and structure of a benchmarking software tool. These items included the selection of appropriate representative data and reference contours obtained from established approaches and the description of available metrics. The benchmark was designed in a way that it could be extendable by inclusion of bespoke segmentation methods, while maintaining its main purpose of being a standard testing platform for newly developed PET-AS methods. An example of implementation of the proposed framework, named PETASset, was built. In this work, a selection of PET-AS methods representing common approaches to PET image segmentation was evaluated within PETASset for the purpose of testing and demonstrating the capabilities of the software as a benchmark platform. RESULTS: A selection of clinical, physical, and simulated phantom data, including "best estimates" reference contours from macroscopic specimens, simulation template, and CT scans was built into the PETASset application database. Specific metrics such as Dice Similarity Coefficient (DSC), Positive Predictive Value (PPV), and Sensitivity (S), were included to allow the user to compare the results of any given PET-AS algorithm to the reference contours. In addition, a tool to generate structured reports on the evaluation of the performance of PET-AS algorithms against the reference contours was built. The variation of the metric agreement values with the reference contours across the PET-AS methods evaluated for demonstration were between 0.51 and 0.83, 0.44 and 0.86, and 0.61 and 1.00 for DSC, PPV, and the S metric, respectively. Examples of agreement limits were provided to show how the software could be used to evaluate a new algorithm against the existing state-of-the art. CONCLUSIONS: PETASset provides a platform that allows standardizing the evaluation and comparison of different PET-AS methods on a wide range of PET datasets. The developed platform will be available to users willing to evaluate their PET-AS methods and contribute with more evaluation datasets.


Assuntos
Algoritmos , Processamento de Imagem Assistida por Computador , Humanos , Imagens de Fantasmas , Software , Tomografia Computadorizada por Raios X
11.
Med Phys ; 44(10): 5089-5095, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28494089

RESUMO

PURPOSE: The purpose of this study is to quantify tumor displacement during real-time PET/CT guided biopsy and to investigate correlations between tumor displacement and false-negative results. METHODS: 19 patients who underwent real-time 18 F-FDG PET-guided biopsy and were found positive for malignancy were included in this study under IRB approval. PET/CT images were acquired for all patients within minutes prior to biopsy to visualize the FDG-avid region and plan the needle insertion. The biopsy needle was inserted and a post-insertion CT scan was acquired. The two CT scans acquired before and after needle insertion were registered using a deformable image registration (DIR) algorithm. The DIR deformation vector field (DVF) was used to calculate the mean displacement between the pre-insertion and post-insertion CT scans for a region around the tip of the biopsy needle. For 12 patients one biopsy core from each was tracked during histopathological testing to investigate correlations of the mean displacement between the two CT scans and false-negative or true-positive biopsy results. For 11 patients, two PET scans were acquired; one at the beginning of the procedure, pre-needle insertion, and an additional one with the needle in place. The pre-insertion PET scan was corrected for intraprocedural motion by applying the DVF. The corrected PET was compared with the post-needle insertion PET to validate the correction method. RESULTS: The mean displacement of tissue around the needle between the pre-biopsy CT and the postneedle insertion CT was 5.1 mm (min = 1.1 mm, max = 10.9 mm and SD = 3.0 mm). For mean displacements larger than 7.2 mm, the biopsy cores gave false-negative results. Correcting pre-biopsy PET using the DVF improved the PET/CT registration in 8 of 11 cases. CONCLUSIONS: The DVF obtained from DIR of the CT scans can be used for evaluation and correction of the error in needle placement with respect to the FDG-avid area. Misregistration between the pre-biopsy PET and the CT acquired with the needle in place was shown to correlate with false negative biopsy results.


Assuntos
Biópsia Guiada por Imagem/métodos , Erros Médicos , Neoplasias/diagnóstico por imagem , Neoplasias/patologia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Humanos , Movimento , Fatores de Tempo
12.
Med Phys ; 44(6): e1-e42, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28120467

RESUMO

PURPOSE: The purpose of this educational report is to provide an overview of the present state-of-the-art PET auto-segmentation (PET-AS) algorithms and their respective validation, with an emphasis on providing the user with help in understanding the challenges and pitfalls associated with selecting and implementing a PET-AS algorithm for a particular application. APPROACH: A brief description of the different types of PET-AS algorithms is provided using a classification based on method complexity and type. The advantages and the limitations of the current PET-AS algorithms are highlighted based on current publications and existing comparison studies. A review of the available image datasets and contour evaluation metrics in terms of their applicability for establishing a standardized evaluation of PET-AS algorithms is provided. The performance requirements for the algorithms and their dependence on the application, the radiotracer used and the evaluation criteria are described and discussed. Finally, a procedure for algorithm acceptance and implementation, as well as the complementary role of manual and auto-segmentation are addressed. FINDINGS: A large number of PET-AS algorithms have been developed within the last 20 years. Many of the proposed algorithms are based on either fixed or adaptively selected thresholds. More recently, numerous papers have proposed the use of more advanced image analysis paradigms to perform semi-automated delineation of the PET images. However, the level of algorithm validation is variable and for most published algorithms is either insufficient or inconsistent which prevents recommending a single algorithm. This is compounded by the fact that realistic image configurations with low signal-to-noise ratios (SNR) and heterogeneous tracer distributions have rarely been used. Large variations in the evaluation methods used in the literature point to the need for a standardized evaluation protocol. CONCLUSIONS: Available comparison studies suggest that PET-AS algorithms relying on advanced image analysis paradigms provide generally more accurate segmentation than approaches based on PET activity thresholds, particularly for realistic configurations. However, this may not be the case for simple shape lesions in situations with a narrower range of parameters, where simpler methods may also perform well. Recent algorithms which employ some type of consensus or automatic selection between several PET-AS methods have potential to overcome the limitations of the individual methods when appropriately trained. In either case, accuracy evaluation is required for each different PET scanner and scanning and image reconstruction protocol. For the simpler, less robust approaches, adaptation to scanning conditions, tumor type, and tumor location by optimization of parameters is necessary. The results from the method evaluation stage can be used to estimate the contouring uncertainty. All PET-AS contours should be critically verified by a physician. A standard test, i.e., a benchmark dedicated to evaluating both existing and future PET-AS algorithms needs to be designed, to aid clinicians in evaluating and selecting PET-AS algorithms and to establish performance limits for their acceptance for clinical use. The initial steps toward designing and building such a standard are undertaken by the task group members.


Assuntos
Algoritmos , Processamento de Imagem Assistida por Computador , Tomografia por Emissão de Pósitrons , Humanos , Razão Sinal-Ruído , Tomografia Computadorizada por Raios X
13.
Phys Med ; 31(8): 969-980, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26321409

RESUMO

PURPOSE: This work describes PETSTEP (PET Simulator of Tracers via Emission Projection): a faster and more accessible alternative to Monte Carlo (MC) simulation generating realistic PET images, for studies assessing image features and segmentation techniques. METHODS: PETSTEP was implemented within Matlab as open source software. It allows generating three-dimensional PET images from PET/CT data or synthetic CT and PET maps, with user-drawn lesions and user-set acquisition and reconstruction parameters. PETSTEP was used to reproduce images of the NEMA body phantom acquired on a GE Discovery 690 PET/CT scanner, and simulated with MC for the GE Discovery LS scanner, and to generate realistic Head and Neck scans. Finally the sensitivity (S) and Positive Predictive Value (PPV) of three automatic segmentation methods were compared when applied to the scanner-acquired and PETSTEP-simulated NEMA images. RESULTS: PETSTEP produced 3D phantom and clinical images within 4 and 6 min respectively on a single core 2.7 GHz computer. PETSTEP images of the NEMA phantom had mean intensities within 2% of the scanner-acquired image for both background and largest insert, and 16% larger background Full Width at Half Maximum. Similar results were obtained when comparing PETSTEP images to MC simulated data. The S and PPV obtained with simulated phantom images were statistically significantly lower than for the original images, but led to the same conclusions with respect to the evaluated segmentation methods. CONCLUSIONS: PETSTEP allows fast simulation of synthetic images reproducing scanner-acquired PET data and shows great promise for the evaluation of PET segmentation methods.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Método de Monte Carlo , Tomografia por Emissão de Pósitrons , Software , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Humanos , Imagens de Fantasmas , Fatores de Tempo
14.
J Nucl Med ; 56(4): 538-44, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25722446

RESUMO

UNLABELLED: Core biopsies obtained using PET/CT guidance contain bound radiotracer and therefore provide information about tracer uptake in situ. Our goal was to develop a method for quantitative autoradiography of biopsy specimens (QABS), to use this method to correlate (18)F-FDG tracer uptake in situ with histopathology findings, and to briefly discuss its potential application. METHODS: Twenty-seven patients referred for a PET/CT-guided biopsy of (18)F-FDG-avid primary or metastatic lesions in different locations consented to participate in this institutional review board-approved study, which complied with the Health Insurance Portability and Accountability Act. Autoradiography of biopsy specimens obtained using 5 types of needles was performed immediately after extraction. The response of autoradiography imaging plates was calibrated using dummy specimens with known activity obtained using 2 core-biopsy needle sizes. The calibration curves were used to quantify the activity along biopsy specimens obtained with these 2 needles and to calculate the standardized uptake value, SUVARG. Autoradiography images were correlated with histopathologic findings and fused with PET/CT images demonstrating the position of the biopsy needle within the lesion. Logistic regression analysis was performed to search for an SUVARG threshold distinguishing benign from malignant tissue in liver biopsy specimens. Pearson correlation between SUVARG of the whole biopsy specimen and average SUVPET over the voxels intersected by the needle in the fused PET/CT image was calculated. RESULTS: Activity concentrations were obtained using autoradiography for 20 specimens extracted with 18- and 20-gauge needles. The probability of finding malignancy in a specimen is greater than 50% (95% confidence) if SUVARG is greater than 7.3. For core specimens with preserved shape and orientation and in the absence of motion, one can achieve autoradiography, CT, and PET image registration with spatial accuracy better than 2 mm. The correlation coefficient between the mean specimen SUVARG and SUVPET was 0.66. CONCLUSION: Performing QABS on core-biopsy specimens obtained using PET/CT guidance enables in situ correlation of (18)F-FDG tracer uptake and histopathology on a millimeter scale. QABS promises to provide useful information for guiding interventional radiology procedures and localized therapies and for in situ high-spatial-resolution validation of radiopharmaceutical uptake.


Assuntos
Autorradiografia/métodos , Biópsia/métodos , Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons/métodos , Tomografia Computadorizada por Raios X/métodos , Neoplasias Ósseas/diagnóstico por imagem , Neoplasias Ósseas/patologia , Calibragem , Estudos de Viabilidade , Humanos , Processamento de Imagem Assistida por Computador , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/patologia , Modelos Logísticos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/patologia , Agulhas , Probabilidade , Estudos Prospectivos , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes
15.
Med Phys ; 40(10): 101501, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24089890

RESUMO

Molecular imaging is the direct or indirect noninvasive monitoring and recording of the spatial and temporal distribution of in vivo molecular, genetic, and/or cellular processes for biochemical, biological, diagnostic, or therapeutic applications. Molecular images that indicate the presence of malignancy can be acquired using optical, ultrasonic, radiologic, radionuclide, and magnetic resonance techniques. For the radiation oncology physicist in particular, these methods and their roles in molecular imaging of oncologic processes are reviewed with respect to their physical bases and imaging characteristics, including signal intensity, spatial scale, and spatial resolution. Relevant molecular terminology is defined as an educational assist. Current and future clinical applications in oncologic diagnosis and treatment are discussed. National initiatives for the development of basic science and clinical molecular imaging techniques and expertise are reviewed, illustrating research opportunities in as well as the importance of this growing field.


Assuntos
Imagem Molecular/métodos , Radioterapia (Especialidade)/métodos , Relatório de Pesquisa , Sociedades Científicas , Humanos
16.
Med Phys ; 39(7): 4175-86, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22830751

RESUMO

PURPOSE: The purpose of this work is to study the influence of photon energy cuts on the results of positron emission tomography (PET) Monte Carlo (MC) simulations. METHODS: MC simulations of PET scans of a box phantom and the NEMA image quality phantom are performed for 32 photon energy cut values in the interval 0.3-350 keV using a well-validated numerical model of a PET scanner. The simulations are performed with two MC codes, egs_pet and GEANT4 Application for Tomographic Emission (GATE). The effect of photon energy cuts on the recorded number of singles, primary, scattered, random, and total coincidences as well as on the simulation time and noise-equivalent count rate is evaluated by comparing the results for higher cuts to those for 1 keV cut. To evaluate the effect of cuts on the quality of reconstructed images, MC generated sinograms of PET scans of the NEMA image quality phantom are reconstructed with iterative statistical reconstruction. The effects of photon cuts on the contrast recovery coefficients and on the comparison of images by means of commonly used similarity measures are studied. RESULTS: For the scanner investigated in this study, which uses bismuth germanate crystals, the transport of Bi X(K) rays must be simulated in order to obtain unbiased estimates for the number of singles, true, scattered, and random coincidences as well as for an unbiased estimate of the noise-equivalent count rate. Photon energy cuts higher than 170 keV lead to absorption of Compton scattered photons and strongly increase the number of recorded coincidences of all types and the noise-equivalent count rate. The effect of photon cuts on the reconstructed images and the similarity measures used for their comparison is statistically significant for very high cuts (e.g., 350 keV). The simulation time decreases slowly with the increase of the photon cut. CONCLUSIONS: The simulation of the transport of characteristic x rays plays an important role, if an accurate modeling of a PET scanner system is to be achieved. The simulation time decreases slowly with the increase of the cut which, combined with the accuracy loss at high cuts, means that the usage of high photon energy cuts is not recommended for the acceleration of MC simulations.


Assuntos
Algoritmos , Interpretação de Imagem Assistida por Computador/métodos , Modelos Estatísticos , Método de Monte Carlo , Tomografia por Emissão de Pósitrons/métodos , Simulação por Computador , Aumento da Imagem/métodos , Transferência Linear de Energia , Fótons , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
17.
Int J Radiat Oncol Biol Phys ; 81(3): 615-22, 2011 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-20933343

RESUMO

PURPOSE: Positron emission-tomography (PET) using 2-[(18)F]fluoro-2-deoxyglucose (FDG-PET) increases sensitivity and specificity of disease detection in lymphoma and thus is standard in lymphoma management. This study examines the effects of coregistering FDG-PET and computed tomography (CT) (PET/CT) scans on treatment planning for lymphoma patients. METHODS AND MATERIALS: Twenty-nine patients (30 positive PET scans) underwent PET/CT treatment planning from July 2004 to February 2007 and were retrospectively studied. For each patient, gross tumor volume was blindly contoured on the CT-only and PET/CT studies by a radiation oncologist. Treatment plans were generated for both the CT-only and PET/CT planning target volumes (PTVs) for all patients. Normal tissue doses and PTV coverage were evaluated using dose--volume histograms for all sites. RESULTS: Thirty-two treatment sites were evaluated. Twenty-one patients had non-Hodgkin lymphoma, 5 patients had Hodgkin lymphoma, and 3 patients had plasma cell neoplasms. Previously undetected FDG-avid sites were identified in 3 patients during PET/CT simulation, resulting in one additional treatment field. Due to unexpected PET/CT simulation findings, 2 patients did not proceed with radiation treatment. The addition of PET changed the volume of 23 sites (72%). The PTV was increased in 15 sites (47%) by a median of 11% (range, 6-40%) and reduced in 8 sites (25%) by a median of 20% (range, 6%-75%). In six (19%) replanned sites, the CT-based treatment plan would not have adequately covered the PTV defined by PET/CT. CONCLUSIONS: Incorporation of FDG-PET into CT-based treatment planning for lymphoma patients resulted in considerable changes in management, volume definition, and normal tissue dosimetry for a significant number of patients.


Assuntos
Fluordesoxiglucose F18 , Doença de Hodgkin/diagnóstico por imagem , Linfoma não Hodgkin/diagnóstico por imagem , Imagem Multimodal/métodos , Neoplasias de Plasmócitos/diagnóstico por imagem , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos , Planejamento da Radioterapia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X , Adulto , Idoso , Idoso de 80 Anos ou mais , Institutos de Câncer , Feminino , Doença de Hodgkin/radioterapia , Humanos , Linfoma não Hodgkin/radioterapia , Masculino , Pessoa de Meia-Idade , Neoplasias de Plasmócitos/radioterapia , Cidade de Nova Iorque , Estudos Retrospectivos , Carga Tumoral , Adulto Jovem
18.
Med Phys ; 33(10): 3690-9, 2006 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17089835

RESUMO

The higher sensitivity to low-energy scattered photons of radiographic film compared to water can lead to significant dosimetric error when the beam quality varies significantly within a field. Correcting for this artifact will provide greater accuracy for intensity modulated radiation therapy (IMRT) verification dosimetry. A procedure is developed for correction of the film energy-dependent response by creating a pencil beam kernel within our treatment planning system to model the film response specifically. Film kernels are obtained from EGSnrc Monte Carlo simulations of the dose distribution from a 1 mm diameter narrow beam in a model of the film placed at six depths from 1.5 to 40 cm in polystyrene and solid water phantoms. Kernels for different area phantoms (50 x 50 cm2 and 25 x 25 cm2 polystyrene and 30 x 30 cm2 solid water) are produced. The Monte Carlo calculated kernel is experimentally verified with film, ion chamber and thermoluminescent dosimetry (TLD) measurements in polystyrene irradiated by a narrow beam. The kernel is then used in convolution calculations to, predict the film response in open and IMRT fields. A 6 MV photon beam and Kodak XV2 film in a polystyrene phantom are selected to test the method as they are often used in practice and can result in large energy-dependent artifacts. The difference in dose distributions calculated with the film kernel and the water kernel is subtracted from film measurements to obtain a practically film artifact free IMRT dose distribution for the Kodak XV2 film. For the points with dose exceeding 5 cGy (11% of the peak dose) in a large modulated field and a film measurement inside a large polystyrene phantom at depth of 10 cm, the correction reduces the fraction of pixels for which the film dose deviates from dose to water by more than 5% of the mean film dose from 44% to 6%.


Assuntos
Dosimetria Fotográfica/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Algoritmos , Artefatos , Relação Dose-Resposta à Radiação , Humanos , Método de Monte Carlo , Imagens de Fantasmas , Fótons , Poliestirenos/química , Radiometria , Radioterapia de Intensidade Modulada/instrumentação , Reprodutibilidade dos Testes , Dosimetria Termoluminescente/métodos , Água
19.
Med Phys ; 33(1): 198-208, 2006 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-16485426

RESUMO

The recently developed GATE (GEANT4 application for tomographic emission) Monte Carlo package, designed to simulate positron emission tomography (PET) and single photon emission computed tomography (SPECT) scanners, provides the ability to model and account for the effects of photon noncollinearity, off-axis detector penetration, detector size and response, positron range, photon scatter, and patient motion on the resolution and quality of PET images. The objective of this study is to validate a model within GATE of the General Electric (GE) Advance/Discovery Light Speed (LS) PET scanner. Our three-dimensional PET simulation model of the scanner consists of 12 096 detectors grouped into blocks, which are grouped into modules as per the vendor's specifications. The GATE results are compared to experimental data obtained in accordance with the National Electrical Manufactures Association/Society of Nuclear Medicine (NEMA/SNM), NEMA NU 2-1994, and NEMA NU 2-2001 protocols. The respective phantoms are also accurately modeled thus allowing us to simulate the sensitivity, scatter fraction, count rate performance, and spatial resolution. In-house software was developed to produce and analyze sinograms from the simulated data. With our model of the GE Advance/Discovery LS PET scanner, the ratio of the sensitivities with sources radially offset 0 and 10 cm from the scanner's main axis are reproduced to within 1% of measurements. Similarly, the simulated scatter fraction for the NEMA NU 2-2001 phantom agrees to within less than 3% of measured values (the measured scatter fractions are 44.8% and 40.9 +/- 1.4% and the simulated scatter fraction is 43.5 +/- 0.3%). The simulated count rate curves were made to match the experimental curves by using deadtimes as fit parameters. This resulted in deadtime values of 625 and 332 ns at the Block and Coincidence levels, respectively. The experimental peak true count rate of 139.0 kcps and the peak activity concentration of 21.5 kBq/cc were matched by the simulated results to within 0.5% and 0.1% respectively. The simulated count rate curves also resulted in a peak NECR of 35.2 kcps at 10.8 kBq/cc compared to 37.6 kcps at 10.0 kBq/cc from averaged experimental values. The spatial resolution of the simulated scanner matched the experimental results to within 0.2 mm.


Assuntos
Análise de Falha de Equipamento/métodos , Interpretação de Imagem Assistida por Computador/métodos , Modelos Biológicos , Método de Monte Carlo , Tomografia por Emissão de Pósitrons/instrumentação , Tomografia por Emissão de Pósitrons/métodos , Software , Algoritmos , Modelos Estatísticos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
20.
Med Phys ; 32(7): 2245-53, 2005 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-16121579

RESUMO

In this study, a measurement protocol is presented that improves the precision of dose measurements using a flat-bed document scanner in conjunction with two new GafChromic film models, HS and Prototype A EBT exposed to 6 MV photon beams. We established two sources of uncertainties in dose measurements, governed by measurement and calibration curve fit parameters contributions. We have quantitatively assessed the influence of different steps in the protocol on the overall dose measurement uncertainty. Applying the protocol described in this paper on the Agfa Arcus II flat-bed document scanner, the overall one-sigma dose measurement uncertainty for an uniform field amounts to 2% or less for doses above around 0.4 Gy in the case of the EBT (Prototype A), and for doses above 5 Gy in the case of the HS model GafChromic film using a region of interest 2 X 2 mm2 in size.


Assuntos
Algoritmos , Periféricos de Computador , Dosimetria Fotográfica/instrumentação , Dosimetria Fotográfica/métodos , Relação Dose-Resposta à Radiação , Doses de Radiação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...