Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Can J Surg ; 67(1): E40-E48, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38320777

RESUMO

BACKGROUND: Large-diameter head (LDH) total hip arthroplasty (THA) with a monobloc acetabular component improves hip stability. However, obtaining initial press-fit stability is quite challenging in atypical acetabula. The purpose of this study was to assess primary and secondary fixation of monobloc cups in atypical acetabula. METHODS: In this consecutive case series, the local arthroplasty database was used to retrospectively identify patients with secondary osteoarthritis who underwent primary hip replacement with press-fit only LDH monobloc acetabular components between 2005 and 2018 and who had a minimum of 2 years of follow-up. Radiographic evaluation was performed at last follow-up, and patient-reported outcome measures (PROMs) were assessed with the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), the Forgotten Joint Score (FJS), and the Patient's Joint Perception (PJP) question. RESULTS: One hundred and six LDH THAs and 19 hip resurfacings were included in the study. Preoperative diagnoses included hip dysplasia (36.8%), Legg-Calve-Perthes disease (32.0%), osteoarthritis with acetabular deficiency (17.6%), periacetabular osteotomy (8.0%), arthrodesis (4.0%), and osteopetrosis (1.6%). After a mean follow-up of 9.2 years, no aseptic loosening of the acetabular component was recorded nor observed on radiologic review. There were 13 (10.4%) revisions unrelated to the acetabular component fixation. The mean WOMAC and FJS scores were 9.2 and 80.9, respectively. In response to the PJP question, 49.4% of the patients perceived their hip as natural, 19.1% as an artificial joint with no restriction, 31.5% as an artificial joint with restriction, and none as a non-functional joint. CONCLUSION: Primary press-fit fixation of monobloc acetabular components with LDH implanted in atypical acetabula led to secondary fixation in all cases with low revision and complication rates and great functional outcomes. With careful surgical technique and experience, systematic use of supplemental screw fixation is not essential in THA with atypical acetabula.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Osteoartrite , Humanos , Artroplastia de Quadril/métodos , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Seguimentos , Estudos Retrospectivos , Reoperação , Osteoartrite/cirurgia , Resultado do Tratamento
2.
J Arthroplasty ; 39(3): 591-599, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38007204

RESUMO

Mechanical alignment (MA) and its tenets have been considered essential for total knee arthroplasty (TKA) success since they were introduced in 1973. However, over time, there have been colossal advances in our knowledge and understanding of the anatomy and kinematics of the knee, as well as in surgical precision and implants. However, the MA systematic principles of prosthetic arthroplasty and implant position related to the lower-extremity mechanical axis, have only recently been called into question. The high rates of dissatisfaction and residual pain reported after MA TKA prompted this questioning, and that leaves plenty of room for improvement. Despite the general consensus that there is great variability between patients' anatomy, it is still the norm to carry out a systematic operation that does not consider individual variations. Evolving to a more personalized arthroplasty surgery was proposed as a rational and reasonable option to improve patient outcomes. Transitioning to a personalized TKA approach requires questioning and even disregarding certain MA TKA principles. Based on current knowledge, we can state that certain principles are erroneous or unfounded. The aim of this narrative review was to discuss and challenge 10 previously accepted, yet we believe, flawed, principles of MA, and to present an alternative concept, which is rooted in personalized TKA techniques.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Humanos , Artroplastia do Joelho/métodos , Articulação do Joelho/cirurgia , Articulação do Joelho/anatomia & histologia , Extremidade Inferior/cirurgia , Fenômenos Biomecânicos , Osteoartrite do Joelho/cirurgia
3.
Orthop Rev (Pavia) ; 14(4): 38926, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36349354

RESUMO

BACKGROUND: Instability is a major cause of failure of revision total hip arthroplasty (THA) which can be avoided with the use of monobloc press-fit cups with large diameter heads (LDH). OBJECTIVE: This consecutive case series analyses whether LDH monobloc components are a safe and clinically beneficial option for revision THA. METHODS: This consecutive case series includes 47 revision THA with LDH monobloc acetabular cup. Acetabular bone defects were Paprosky type I (42), type IIA (2) and type IIC (3). The Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), Forgotten Joint Score (FJS) and the Patient's Joint Perception (PJP) scores were analysed and a radiographic evaluation for signs of implant dysfunction was performed. RESULTS: After a mean follow-up of 4.5 years, there were 5 (10.6%) acetabular cup re-revisions: 2 loss of primary fixation and 3 instabilities. Implant survivorship at 4-years was 89.4% (95% CI: 89.3 to 89.5). Recurrent hip dislocation was reported in 1 patient (2.1%) and remains under conservative treatment. The mean WOMAC and FJS were 19.5 (16.8; 0.0 to 58.3) and 57.3 (28.9; 6.3 to 100.0), respectively. Regarding the PJP, 3 (8.8%) patients perceived their hip as natural, 8 (23.5%) as an artificial joint with no restriction, 14 (41.2%) with minor restriction and 9 (26.5%) with major restriction. CONCLUSION: In cases of revision THA with limited bone loss, press-fit primary fixation with LDH monobloc acetabular components are valuable options that offer excellent mid-term out-comes with low re-revision and joint instability rates.

4.
Knee Surg Sports Traumatol Arthrosc ; 30(2): 705-712, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33452903

RESUMO

PURPOSE: While kinematic alignment (KA) total knee arthroplasty (TKA) with cemented implants has been shown to provide equivalent or better results than mechanical alignment, its combination with cementless fixation has not yet been documented. The purpose of this study is to report (1) revision rate and causes, (2) clinical results based on patient report outcome measures (PROMs), and (3) radiological signs of implant dysfunction in patients with an uncemented TKA implanted with restricted KA (rKA), after a minimum follow-up of 2 years. METHODS: This study included the first 100 consecutive uncemented cruciate retaining TKAs implanted between November 2015 and February 2018 by a single surgeon following rKA principles. At last follow-up, all adverse events and PROMs assessed by WOMAC, KOOS, and FJS scores were documented. Radiographic evaluation was performed to identify signs of implant loosening. RESULTS: After a mean follow-up of 49 months (32, 60), no implant revision was performed for aseptic loosening. Three revisions were performed: one for malalignment, one for a deep infection, and one for instability. The mean WOMAC score was 20.1 (0-79, 21.3), the mean KOOS score was 71.5 (19.0-96.6, 19.8), and the mean FJS score was 65.9 (0-100, 29.6). No radiological evidence of implant aseptic loosening or osteolysis was identified. CONCLUSION: This study shows that in 99% of our cases, rKA combined with the tested cementless TKA implant allowed for adequate secondary fixation and good functional outcomes in the short term. Favourable mid- to long-term implant survivorship is anticipated. LEVEL OF EVIDENCE: III.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Artroplastia do Joelho/métodos , Fenômenos Biomecânicos , Humanos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Osseointegração , Falha de Prótese , Resultado do Tratamento
6.
Front Surg ; 8: 721379, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34513916

RESUMO

Purpose: Kinematic alignment (KA) for primary total knee arthroplasty (TKA) has been shown to provide equivalent or better results to mechanical alignment (MA). The use of KA in revision TKA to restore the individual knee anatomy, kinematics, and soft-tissue balance, has not been documented yet. The purpose of this study is to describe the technique for performing TKA revision using the restricted KA (rKA) protocol and to report (1) rerevision rate and adverse events, (2) patient-reported outcome measures (PROMs), and (3) radiological signs of implant dysfunction related to this technique. Methods: The rKA protocol was used in 43 selected TKA revisions cases suitable for the technique. Adverse events, reoperation, revision, and their causes were recorded. In addition, PROMs assessed by WOMAC score and radiographic evaluation to identify signs of implant dysfunction were documented at last follow-up. Results: After a mean follow-up of 4.0 years (0.9-7.7, ±2), only one rerevision (2.3%) was required for persisting instability (polyethylene liner exchange from posterior stabilized to a semi-constrained). Short-cemented stems were used for both the femur and tibia in 28 (65%) cases, for the femur alone in 13 (30%) cases, and no stems in two cases. In 31 (72%) cases, a standard posterior stabilized tibial insert was used, while 12 (28%) cases required a semi-constrained insert. The mean WOMAC score was 34.4 (0-80, ±21.7). Mean postoperative arithmetic hip-knee-ankle angle (HKA) was 0.8° varus (from 5° varus to 4° valgus), mean mechanical distal femoral angle was 1.7° valgus (from 2° varus to 5° valgus), and mean mechanical tibia proximal angle was 2.2° varus (from 5° varus to 1° valgus). No radiological evidence of aseptic loosening or periprosthetic radiolucencies were identified. Conclusion: Although current revision TKA implants are not ideal for revision TKA performed with rKA, they are an appealing alternative to MA, especially in cases of early, non-wear-related, unsuccessful MA TKAs. rKA TKA revision using short-cemented stems in conjunction with meticulous preoperative planning is safe in the mid-term. Level of evidence: IV.

7.
BMC Musculoskelet Disord ; 22(1): 400, 2021 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-33941155

RESUMO

BACKGROUND: The high failure rates of metal on metal (MoM) large diameter head total hip arthroplasty (LDH THA) and hip resurfacing (HR) prevented their long-term comparisons with regards to clinical outcome. Such knowledge would be important as ceramic LDH bearing is now available. With long-term follow-up, we investigated the difference in 1) patient-reported outcome measures (PROMs); 2) revision and adverse events rates, and 3) metal ion levels between MoM LDH THA and HR. METHODS: Forty-eight patients were randomized for LDH THA (24) or HR (24) with the same MoM articulation. At a mean follow-up of 14 years, we compared between groups different PROMs, the number of revisions and adverse events, whole blood Cobalt (Co) and Chromium (Cr) ion levels, and radiographic signs of implant dysfunction. RESULTS: LDH THA (all cases: revised and well-functioning) had significantly better WOMAC (94 versus 85, p = 0.04), and more frequently reported having no limitation (p = 0.04). LDH THA revision rate was 20.8% (5/24) versus 8.3% (2/24) for HR (p = 0.4). Mean Co and Cr ion levels were higher in LDH THA compared to the HR (Co: 3.8 µg/L vs 1.7 µg/L; p = 0.04 and Cr: 1.9 µg/L vs 1.4 µg/L, p = 0.1). On radiographic analyses, 2 LDH THAs showed signs of adverse reaction to metal debris, whereas 1 loose femoral HR component was documented. CONCLUSION: In the long-term, MoM LDH THA had a high trunnion related revision rate but nonetheless showed better PROMs compared to HR. Provided with a well-functioning modular junction, non-MoM LDH THA would offer an appealing option. TRIAL REGISTRATION: ClinicalTrials.gov ( NCT04516239 ), August 18, 2020. Retrospectively registered.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Próteses Articulares Metal-Metal , Artroplastia de Quadril/efeitos adversos , Cromo , Cobalto , Prótese de Quadril/efeitos adversos , Humanos , Desenho de Prótese , Reoperação
8.
Knee Surg Sports Traumatol Arthrosc ; 28(5): 1532-1541, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-31201441

RESUMO

PURPOSE: The objective of this study was to calculate bone resection thicknesses and resulting gap sizes, simulating a measured resection mechanical alignment (MA) technique for total knee arthroplasty (TKA). METHODS: MA bone resections were simulated on 1000 consecutive lower limb CT scans from patients undergoing TKA. Femoral rotation was aligned with either the surgical trans-epicondylar axis (TEA) or with 3° of external rotation to the posterior condyles (PC). Imbalances in the extension space, flexion space, medial compartment and lateral compartment were calculated. RESULTS: Extension space imbalances (≥ 3 mm) occurred in 25% of varus and 54% of valgus knees and severe imbalances (≥ 5 mm) were present in up to 8% of varus and 19% of valgus knees. Higher flexion space imbalance rates were created with TEA versus PC (p < 0.001). Using TEA, only 49% of varus and 18% of valgus knees had < 3 mm of imbalance throughout the extension and flexion spaces, and medial and lateral compartments. CONCLUSION: A systematic use of the simulated measured resection MA technique for TKA leads to many cases with imbalance. Some imbalances may not be correctable surgically and may result in TKA instability. Modified versions of the MA technique or other alignment methods that better reproduce knee anatomies should be explored. LEVEL OF EVIDENCE: 2.


Assuntos
Artroplastia do Joelho/métodos , Fêmur/cirurgia , Articulação do Joelho/cirurgia , Osteoartrite do Joelho/cirurgia , Tíbia/cirurgia , Mau Alinhamento Ósseo/prevenção & controle , Mau Alinhamento Ósseo/cirurgia , Humanos , Amplitude de Movimento Articular
9.
Acta Orthop ; 90(6): 602-609, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31610681

RESUMO

Background and purpose - Mechanical alignment techniques for total knee arthroplasty (TKA) introduce significant anatomic alteration and secondary ligament imbalances. We propose a restricted kinematic alignment (rKA) protocol to minimize these issues and improve TKA clinical outcomes.Patients and methods - rKA tibial and femoral bone resections were simulated on 1,000 knee CT scans from a database of patients undergoing TKA. rKA was defined by the following criteria: independent tibial and femoral cuts within 5° of the bone neutral mechanical axis, with a resulting HKA within 3° of neutral. Imbalances in the extension space, flexion space at 90°, medial compartment and lateral compartment were calculated and compared with measured resection mechanical alignment (MA) results. 2 MA techniques were simulated for rotation using the surgical transepicondylar axis (TEA) and 3° to the posterior condyles (PC).Results - Extension space imbalances ≥ 3 mm occurred in 33% of TKAs with MA technique versus 8.3% with rKA (p < 0.001). Similarly, more frequent flexion space imbalance ≥ 3mm was created by MA technique (TEA 34% or 3° PC 15%) versus rKA (6.4%, p < 0.001). Using MA with TEA or PC, there were only 49% and 63% of the knees respectively with < 3 mm of imbalance throughout the extension and flexion spaces and medial and lateral compartments versus 92% using rKA (p < 0.001).Interpretation - significantly fewer imbalances are created using rKA versus MA for TKA. rKA may be the best compromise, by helping the surgeon to preserve native knee ligament balance during TKA and avoid residual instability, whilst keeping the lower limb alignment within a safe range.


Assuntos
Artroplastia do Joelho/métodos , Simulação por Computador , Imageamento Tridimensional , Articulação do Joelho/diagnóstico por imagem , Fenômenos Biomecânicos , Humanos , Articulação do Joelho/cirurgia , Tomografia Computadorizada por Raios X
10.
Hip Int ; 29(3): 262-269, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30378457

RESUMO

INTRODUCTION: In total hip arthroplasty (THA), local adverse reaction to metal debris (ARMD) may be caused by abnormal metal ion release from a metal-on-metal (MoM) bearing, or by wear and corrosion of the implant's modular junction. The aim of this study was to compare ion levels and rate of ARMD between patients sharing the same MoM bearing but 1 group having monoblock stems versus another having modular stems. MATERIALS AND METHODS: Whole blood cobalt (Co) and chromium (Cr) ion concentrations, ARMD rate, revision rate, and function measured by UCLA and WOMAC scores were compared between groups. RESULTS: ARMD rate was significantly higher in the modular group (46%) compared with the monoblock group (16%, p = 0.031). Revision for ARMD was performed at 52.8 ± 8.1 months in the modular group versus 98.2 ± 15.5 months after primary THA in the monoblock group. ARMD originated from wear and corrosion of the junction between stem and femoral head adapter sleeve in all monoblock cases, and the junction between stem and modular neck in all the modular ones. Cr and Co ions levels were significantly higher in the modular stem group ( p < 0.001 for both). CONCLUSIONS: Although both groups had MoM bearings, corrosion at stem/neck or neck/head junctions combining dissimilar metal (Ti and Cr-Co) was seen as the source of excess metal ions release leading to ARMD. Poor performance of the modular junction may be more deleterious than wear of the bearing. To avoid such complications, THA femoral stem modular junctions should be eliminated (return to a full monoblock implant) or have improved junction design.


Assuntos
Artroplastia de Quadril/métodos , Cromo/sangue , Cobalto/sangue , Prótese de Quadril/efeitos adversos , Próteses Articulares Metal-Metal/efeitos adversos , Adulto , Idoso , Biomarcadores/sangue , Corrosão , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Falha de Prótese
11.
Open Orthop J ; 11: 1337-1344, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29290872

RESUMO

BACKGROUND: In recent decades, the popularity of modular necks in total hip arthroplasty (THA) has increased since modular necks offer the potential to restore the patient's native anatomy, and thus improve stability. Unfortunately, modular necks are associated with higher complication rates, including implant fracture and modular junction corrosion with adverse local tissue reaction to metal debris. OBJECTIVE: The objective of this study was to determine the impact of modular neck material on titanium (Ti), chrome (Cr), and cobalt (Co) metal ion levels in patients who underwent a THA with Ti femoral stem, Ti or CrCo modular neck, and ceramic-on-ceramic (CoC) bearing. METHODS: Whole blood Ti, Cr, and Co levels were compared at a minimum 1-year follow-up in 36 patients who underwent unilateral, primary CoC large-diameter head THA with Profemur® Preserve modular femoral stems (MicroPort, Arlington, TX, USA). RESULTS: Higher Co concentrations were observed in the CrCo modular neck group (0.46 versus 0.26 µg/l in the Ti neck group, P=0.004) and higher Ti concentrations were observed in the Ti modular neck group (1.98 vs 1.59 µg/l in the CrCo neck group, P=0.007). However, these differences were not clinically meaningful since the absolute values remained within what is considered the safe range of Ti, Cr, and Co ions in whole blood. No patients were re-operated or revised. CONCLUSION: Modular neck materials had an impact on whole blood metal ion levels but the concentrations measured remained within the safe range at 1-year follow-up. There were no indirect signs of modular junction corrosion with either CrCo or Ti femoral necks.

12.
Am J Sports Med ; 40(5): 1046-52, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22415207

RESUMO

BACKGROUND: Osteochondral autografts in mosaicplasty are inserted in a press-fit fashion, and hence, patients are kept nonweightbearing for up to 2 months after surgery to allow bone healing and prevent complications. Very little has been published regarding alternative fixation techniques of those grafts. HYPOTHESIS: Osteochondral autografts stabilized with a resorbable osteoconductive bone cement would have a greater load-bearing capacity than standard press-fit grafts. STUDY DESIGN: Controlled laboratory study. METHODS: Biomechanical testing was conducted on 8 pairs of cadaveric bovine distal femurs. For the first 4 pairs, 6 single osteochondral autografts were inserted in a press-fit fashion on one femur. On the contralateral femur, 6 grafts were stabilized with a calcium triglyceride osteoconductive bone cement. For the 4 remaining pairs of femurs, 4 groups of 3 adjacent press-fit grafts were inserted on one femur, whereas on the contralateral femur, grafts were cemented. After a maturation period of 48 hours, axial loading was applied on all single grafts and on the middle graft of each 3-in-a-row series. RESULTS: For the single-graft configuration, median loads required to sink the press-fit and cemented grafts by 2 and 3 mm were 281.87 N versus 345.56 N (P = .015) and 336.29 N versus 454.08 N (P = .018), respectively. For the 3-in-a-row configuration, median loads required to sink the press-fit and cemented grafts by 2 and 3 mm were 260.31 N versus 353.47 N (P = .035) and 384.83 N versus 455.68 N (P = .029), respectively. CONCLUSION: Fixation of osteochondral grafts using bone cement appears to improve immediate stability over the original mosaicplasty technique for both single- and multiple-graft configurations. CLINICAL RELEVANCE: Achieving greater primary stability of osteochondral grafts could potentially accelerate postoperative recovery, allowing early weightbearing and physical therapy.


Assuntos
Cimentos Ósseos , Transplante Ósseo/métodos , Cartilagem/transplante , Fêmur/transplante , Implantes Absorvíveis , Animais , Fenômenos Biomecânicos , Transplante Ósseo/instrumentação , Cartilagem/fisiologia , Bovinos , Fêmur/fisiologia , Fêmur/cirurgia , Suporte de Carga
13.
Med Eng Phys ; 31(9): 1182-6, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19625205

RESUMO

In vitro cyclic loading and load-to-failure testing of muscles and tendons require a reliable linking device between tissues and the actuator that can transmit high loads without slippage or tissue damage. This article describes a simple custom-made thermoelectrically cooled freeze clamp. The effectiveness of the clamp to transmit loads without tissue slippage was evaluated on 10 canine quadriceps femoris myo-tendinous junctions in both load-to-failure and cyclic loading settings. Dynamic cyclic loading during an extensive period of time was successfully achieved. Loads up to 4.84 kN were applied in quasi-static conditions without evidence of clamp slippage or failure.


Assuntos
Músculos/fisiologia , Estresse Mecânico , Tendões/fisiologia , Animais , Fenômenos Biomecânicos , Cães , Eletrofisiologia/métodos , Desenho de Equipamento , Temperatura Alta , Teste de Materiais , Procedimentos Ortopédicos , Resistência à Tração , Fatores de Tempo , Suporte de Carga
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...