Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 178
Filtrar
1.
Eur J Cardiothorac Surg ; 65(5)2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38710669

RESUMO

OBJECTIVES: The objective of this analysis was to assess the normal haemodynamic performance of contemporary surgical aortic valves at 1 year postimplant in patients undergoing surgical aortic valve replacement for significant valvular dysfunction. By pooling data from 4 multicentre studies, this study will contribute to a better understanding of the effectiveness of surgical aortic valve replacement procedures, aiding clinicians and researchers in making informed decisions regarding valve selection and patient management. METHODS: Echocardiograms were assessed by a single core laboratory. Effective orifice area, dimensionless velocity index, mean aortic gradient, peak aortic velocity and stroke volume were evaluated. RESULTS: The cohort included 2958 patients. Baseline age in the studies ranged from 70.1 ± 9.0 to 83.3 ± 6.4 years, and Society of Thoracic Surgeons risk of mortality was 1.9 ± 0.7 to 7.5 ± 3.4%. Twenty patients who had received a valve model implanted in fewer than 10 cases were excluded. Ten valve models (all tissue valves; n = 2938 patients) were analysed. At 1 year, population mean effective orifice area ranged from 1.46 ± 0.34 to 2.12 ± 0.59 cm2, and dimensionless velocity index, from 0.39 ± 0.07 to 0.56 ± 0.15. The mean gradient ranged from 8.6 ± 3.4 to 16.1 ± 6.2 mmHg with peak aortic velocity of 1.96 ± 0.39 to 2.65 ± 0.47 m/s. Stroke volume was 75.3 ± 19.6 to 89.8 ± 24.3 ml. CONCLUSIONS: This pooled cohort is the largest to date of contemporary surgical aortic valves with echocardiograms analysed by a single core lab. Overall haemodynamic performance at 1 year ranged from good to excellent. These data can serve as a benchmark for other studies and may be useful to evaluate the performance of bioprosthetic surgical valves over time. CLINICAL TRIAL REGISTRATION NUMBER: NCT02088554, NCT02701283, NCT01586910 and NCT01531374.


Assuntos
Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Hemodinâmica , Humanos , Hemodinâmica/fisiologia , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Idoso , Feminino , Masculino , Idoso de 80 Anos ou mais , Implante de Prótese de Valva Cardíaca/métodos , Ecocardiografia , Pessoa de Meia-Idade , Desenho de Prótese
2.
Artigo em Inglês | MEDLINE | ID: mdl-38751044

RESUMO

OBJECTIVES: Surgical aortic valve replacement through conventional sternotomy yields excellent results. Minimally invasive techniques are deemed equally safe and serve as a viable and less traumatic alternative. However, it is unclear how both surgical techniques affect patient-reported outcomes. The objective of this trial is to compare postoperative cardiac-related quality of life and postoperative pain after upper hemisternotomy and conventional surgical aortic valve replacement. METHODS: In this single-centre, open-label, investigator-initiated randomized clinical trial, patients were randomized to upper hemisternotomy or conventional full median sternotomy. Patients unable to undergo randomization were monitored prospectively (registry group). Primary outcome was cardiac-specific quality of life, measured with the Kansas City Cardiomyopathy Questionnaire up to 1 year postoperatively. RESULTS: Patients undergoing upper hemisternotomy had a significantly higher physical limitation domain score across all postoperative time points than patients undergoing conventional surgical aortic valve replacement (estimated mean difference 2.12 points; P = 0.014). Patients undergoing upper hemisternotomy were more likely to have a pain score <30 the first 2 days postoperatively than patients undergoing conventional surgical aortic valve replacement (odds ratio 2.63; P = 0.007). This was associated with reduced opioid analgesic intake. Postoperative surgical outcome did not differ between both groups. CONCLUSIONS: Surgical aortic valve replacement through both conventional sternotomy and upper hemisternotomy resulted in clinically similar and important improvements in quality of life, with a small advantage for upper hemisternotomy, while there was no compromise in safety.

3.
Aorta (Stamford) ; 2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38698623

RESUMO

The prevalence of coronary artery disease (CAD) in bicuspid aortic valve (BAV) patients is a debatable topic. Several studies have indicated that BAV patients have a lower prevalence of CAD compared with patients with a tricuspid aortic valve (TAV), but the effects of age and gender have not always been considered. This systematic review provides an overview of articles which report on CAD in BAV and TAV patients. Searches were executed in April 2021 and January 2022 according to the PRISMA (Preferred Reporting Items for Systematic reviews and Meta-analyses) guidelines in three online databases: Medline, Embase, and Scopus. Screening and data extraction was done by two investigators separately. Primary and secondary outcomes were compared between BAV and TAV patients; a fixed effects model was used for correcting on confounders. Literature search yielded 1,529 articles with 44 being eligible for inclusion. BAV patients were younger (56.4 ± 8.3 years) than TAV patients (64 ± 10.3 years, p < 0.001). All CAD risk factors and CAD were more prevalent in TAV patients. No significant difference remained after correcting for age and gender as confounders. BAV patients have a lower prevalence of CAD and CAD risk factors compared with TAV patients. However, when the age differences between both groups are considered in the analyses, a similar prevalence of both CAD and CAD risk factors is found.

4.
BMC Cardiovasc Disord ; 24(1): 258, 2024 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-38762715

RESUMO

BACKGROUND: Extracorporeal blood purification has been widely used in intensive care medicine, nephrology, toxicology, and other fields. During the last decade, with the emergence of new adsorptive blood purification devices, hemoadsorption has been increasingly applied during CPB in cardiac surgery, for patients at different inflammatory risks, or for postoperative complications. Clinical evidence so far has not provided definite answers concerning this adjunctive treatment. The current systematic review aimed to critically assess the role of perioperative hemoadsorption in cardiac surgery, by summarizing the current knowledge in this clinical setting. METHODS: A literature search of PubMed, Cochrane library, and the database provided by CytoSorbents was conducted on June 1st, 2023. The search terms were chosen by applying neutral search keywords to perform a non-biased systematic search, including language variations of terms "cardiac surgery" and "hemoadsorption". The screening and selection process followed scientific principles (PRISMA statement). Abstracts were considered for inclusion if they were written in English and published within the last ten years. Publications were eligible for assessment if reporting on original data from any type of study (excluding case reports) in which a hemoadsorption device was investigated during or after cardiac surgery. Results were summarized according to sub-fields and presented in a tabular view. RESULTS: The search resulted in 29 publications with a total of 1,057 patients who were treated with hemoadsorption and 988 control patients. Articles were grouped and descriptively analyzed due to the remarkable variability in study designs, however, all reported exclusively on CytoSorb® therapy. A total of 62% (18/29) of the included articles reported on safety and no unanticipated adverse events have been observed. The most frequently reported clinical outcome associated with hemoadsorption was reduced vasopressor demand resulting in better hemodynamic stability. CONCLUSIONS: The role of hemoadsorption in cardiac surgery seems to be justified in selected high-risk cases in infective endocarditis, aortic surgery, heart transplantation, and emergency surgery in patients under antithrombotic therapy, as well as in those who develop a dysregulated inflammatory response, vasoplegia, or septic shock postoperatively. Future large randomized controlled trials are needed to better define proper patient selection, dosing, and timing of the therapy.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Humanos , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Resultado do Tratamento , Fatores de Risco , Complicações Pós-Operatórias/terapia , Complicações Pós-Operatórias/etiologia , Ponte Cardiopulmonar/efeitos adversos , Masculino , Feminino , Medição de Risco , Idoso , Pessoa de Meia-Idade
5.
J Clin Med ; 13(7)2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38610884

RESUMO

Background: Post-cardiotomy cardiogenic shock (PCCS), which is defined as severe low cardiac output syndrome after cardiac surgery, has a mortality rate of up to 90%. No study has yet been performed to compare patients with PCCS treated by conservative means to patients receiving additional mechanical circulatory support with veno-arterial extracorporeal membrane oxygenation (ECMO). Methods: A single-center retrospective analysis from January 2018 to June 2022 was performed. Results: Out of 7028 patients who underwent cardiac surgery during this time period, 220 patients (3%) developed PCCS. The patients were stratified according to their severity of shock based on the Stage Classification Expert Consensus (SCAI) group. Known risk factors for shock-related mortality, including the vasoactive-inotropic score (VIS) and plasma lactate levels, were assessed at structured intervals. In patients treated additionally with ECMO (n = 73), the in-hospital mortality rate was 60%, compared to an in-hospital mortality rate of 85% in patients treated by conservative means (non-ECMO; n = 52). In 18/73 (25%) ECMO patients, the plasma lactate level normalized within 48 h, compared to 2/52 (4%) in non-ECMO patients. The morbidity of non-ECMO patients compared to ECMO patients included a need for dialysis (42% vs. 60%), myocardial infarction (19% vs. 27%), and cerebrovascular accident (17% vs. 12%). Conclusions: In conclusion, the additional use of ECMO in PCCS holds promise for enhancing outcomes in these critically ill patients, more rapid improvement of end-organ perfusion, and the normalization of plasma lactate levels.

6.
Respir Res ; 25(1): 117, 2024 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-38454475

RESUMO

Heart surgery may be complicated by acute lung injury and adult respiratory distress syndrome. Expression and release of mucins MUC5AC and MUC5B in the lungs has been reported to be increased in acute lung injury. The aim of our study was to [1] investigate the perioperative changes of MUC5AC, MUC5B and other biomarkers in mini-bronchoalveolar lavage (minBAL), and [2] relate these to clinical outcomes after cardiac surgery. In this prospective cohort study in 49 adult cardiac surgery patients pre- and post-surgery non-fiberscopic miniBAL fluids were analysed for MUC5AC, MUC5B, IL-8, human neutrophil elastase, and neutrophils. All measured biomarkers increased after surgery. Perioperative MUC5AC-change showed a significant negative association with postoperative P/F ratio (p = 0.018), and a positive association with ICU stay (p = 0.027). In conclusion, development of lung injury after cardiac surgery and prolonged ICU stay are associated with an early increase of MUC5AC as detected in mini-BAL.


Assuntos
Lesão Pulmonar Aguda , Procedimentos Cirúrgicos Cardíacos , Adulto , Humanos , Líquido da Lavagem Broncoalveolar , Estudos Prospectivos , Lesão Pulmonar Aguda/diagnóstico , Lesão Pulmonar Aguda/etiologia , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Biomarcadores/análise , Mucina-5AC/metabolismo
7.
JTCVS Open ; 17: 47-54, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38420548

RESUMO

Background: Although various hemodynamic parameters to assess prosthetic performance are available, prosthesis-patient mismatch (PPM) is defined exclusively by effective orifice area (EOA) index thresholds. Adjusting for the Society of Thoracic Surgeons predicted risk of mortality (STS PROM), we aimed to explore the added value of postoperative hemodynamic parameters for the prediction of all-cause mortality at 5 years after aortic valve replacement. Methods: Data were obtained from the Pericardial Surgical Aortic Valve Replacement (PERIGON) Pivotal Trial, a multicenter prospective cohort study examining the performance of the Avalus bioprosthesis. Candidate predictors were assessed at the first follow-up visit; patients who had no echocardiography data, withdrew consent, or died before this visit were excluded. Candidate predictors included peak jet velocity, mean pressure gradient, EOA, predicted and measured EOA index, Doppler velocity index, indexed internal prosthesis orifice area, and categories for PPM. The performance of Cox models was investigated using the c-statistic and net reclassification improvement (NRI), among other tools. Results: A total of 1118 patients received the study valve, of whom 1022 were eligible for the present analysis. In univariable analysis, STS PROM was the sole significant predictor of all-cause mortality (hazard ratio, 1.40; 95% confidence interval, 1.26-1.55). When extending the STS PROM with single hemodynamic parameters, neither the c-statistics nor the NRIs demonstrated added prognostic value compared to a model with STS PROM alone. Similar findings were observed when multiple hemodynamic parameters were added. Conclusions: The STS PROM was found to be the main predictor of patient prognosis. The additional prognostic value of postoperative hemodynamic parameters for the prediction of all-cause mortality was limited.

8.
Ann Thorac Surg ; 117(1): 120-126, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37714504

RESUMO

BACKGROUND: Real-world evidence supporting the reproducibility and superiority of valve repair over replacement in active mitral valve infective endocarditis is lacking. METHODS: Data from a prospective nationwide database, including all cardiac surgical procedures in The Netherlands, were used. Adult patients undergoing primary mitral valve intervention who had a diagnosis of active infective endocarditis and who underwent surgery between 2013 and 2020 were included. Survival analysis was performed for the whole follow-up period as well as after applying the landmark of 90 days. RESULTS: Of 715 patients who met the inclusion criteria, 294 (41.1%) underwent valve repair. Mitral valve repair rates decreased slightly over the course of the study. The early mortality rate was 13.0%, and a trend of steadily declining early mortality rates over the course of the study, despite a steady increase in patient complexity, was observed. On risk-adjusted analysis, mitral valve replacement demonstrated inferior results when compared with valve repair (adjusted hazard ratio, 2.216; 95% CI, 1.425-3.448; P < .001), even after a landmark analysis was performed (adjusted hazard ratio 2.489; 95% CI, 1.124-5.516; P = .025). These results were confirmed by a propensity score-adjusted analysis (adjusted hazard ratio 2.251; 95% CI, 1.029-4.21; P = .042). CONCLUSIONS: Contemporary trends in mitral valve surgery for active infective endocarditis suggest growing patient complexity but slightly declining early mortality rates. A trend of decreasing mitral valve repair rates was seen. The results of this study suggest improved late outcomes of valve repair compared with valve replacement.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Endocardite Bacteriana , Endocardite , Implante de Prótese de Valva Cardíaca , Adulto , Humanos , Valva Mitral/cirurgia , Estudos Prospectivos , Reprodutibilidade dos Testes , Endocardite/diagnóstico , Endocardite Bacteriana/cirurgia , Procedimentos Cirúrgicos Cardíacos/métodos , Resultado do Tratamento
9.
Am J Cardiol ; 210: 58-64, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-37838070

RESUMO

Oral anticoagulation with vitamin K antagonists is currently advised for a period of 3 months after surgical mitral valve repair, regardless of the rhythm status. The evidence supporting this recommendation is weak and recent studies have challenged the safety and efficacy of this recommendation. A systematic review of literature was conducted by searching PubMed, Embase, Web of Science, Emcare, and Cochrane Library databases for original publications comparing the efficacy and safety of oral anticoagulation with vitamin K antagonists to antiplatelet treatment early after mitral valve surgery in patients with no atrial fibrillation. Study end points included thromboembolic complications, bleeding complications and survival. A total of 5 studies, including 5,093 patients, met the inclusion criteria; 2,824 patients were included in the oral anticoagulation and 2,269 in the antiplatelet treatment group. Pooled analyses demonstrated no beneficial effect of oral anticoagulation on the incidence of thromboembolic complications (risk ratio 1.14, 95% confidence interval 0.76 to 1.70, p = 0.53, I2 = 8%). Moreover, oral anticoagulation did not result in a significantly increased risk of bleeding complications (risk ratio 0.89, 95% confidence interval 0.32 to 2.44, p = 0.81, I2 = 87%). When combining the efficacy and safety end points, no difference was observed between groups (risk ratio 1.01, 95% confidence interval 0.51 to 1.97, p = 0.99 I2 = 85%). Likewise, mortality did not differ between groups (risk ratio 0.89, 95% confidence interval 0.15 to 5.23, p = 0.90 I2 = 71%). Our results confirmed the safety but failed to confirm the efficacy of oral anticoagulation in patients who underwent mitral valve surgery. A randomized controlled trial would provide the evidence needed to support treatment recommendations.


Assuntos
Valva Mitral , Tromboembolia , Humanos , Valva Mitral/cirurgia , Anticoagulantes , Hemorragia/induzido quimicamente , Tromboembolia/epidemiologia , Tromboembolia/etiologia , Tromboembolia/prevenção & controle , Vitamina K , Administração Oral
10.
J Cardiol ; 2023 Dec 14.
Artigo em Inglês | MEDLINE | ID: mdl-38103635

RESUMO

BACKGROUND: Clinical and echocardiographic results of valve repair for mitral regurgitation in the setting of atrial fibrillation are poorly studied. METHODS: Between January 2008 and December 2020, 89 patients underwent valve repair for mitral regurgitation in the setting of atrial fibrillation. Clinical and echocardiographic follow-up data were collected and studied. The primary composite endpoint consisted of all-cause mortality or hospitalization for heart failure. RESULTS: Valve repair with true-sized annuloplasty was performed in 83 (93 %) and restrictive annuloplasty in 6 (7 %) patients. Early mortality occurred in 3 (3 %) and residual mitral regurgitation in 1 (1 %) patient. During a median follow-up of 5.4 years (interquartile range 3.4-9.5), 25 patients died, 6 due to end-stage heart failure. Ten patients were hospitalized for heart failure. The estimated event-free survival rate at 10 years was 48.2 % (95 % CI 33.5 %-62.9 %). Recurrent mitral regurgitation was observed in 14 patients and most often caused by leaflet tethering. When analyzed as a time-dependent variable, recurrent regurgitation was related to the occurrence of the primary endpoint (hazard ratio 3.192, 95 % CI 1.219-8.359, p = 0.018). On exploratory sub-analyses, no recurrent regurgitation was observed after restrictive annuloplasty or in patients with paroxysmal atrial fibrillation. Moreover, recurrent regurgitation was observed more often when signs of left ventricular impairment were present preoperatively. CONCLUSIONS: Despite good initial results, recurrent regurgitation was a frequent observation after valve repair for mitral regurgitation in atrial fibrillation and had an effect on heart failure related morbidity and mortality. Refinements in the timing of surgery and surgical technique might help improve outcomes.

13.
Eur J Cardiothorac Surg ; 64(3)2023 09 07.
Artigo em Inglês | MEDLINE | ID: mdl-37688566

RESUMO

OBJECTIVES: The clinical importance of optimal post-repair mitral valve diastolic performance is increasingly being recognized. The haemodynamic effect of a partial annuloplasty band implantation, in comparison to a full ring, remains insufficiently explored. METHODS: Patients undergoing mitral valve repair for pure degenerative disease between 2011 and 2019 at 2 experienced heart valve centres were eligible for inclusion. Exclusion criteria were concomitant procedures other than tricuspid valve repair and ablation procedures for atrial fibrillation. Pre-discharge and follow-up echocardiograms (1-4 years after surgery) were analysed to assess haemodynamic mitral valve performance. RESULTS: Of 535 patients meeting the inclusion criteria, 364 (68.0%) patients underwent full annuloplasty ring and 171 (31.0%) partial band implantation. On predischarge echocardiogram, post-repair mitral valve gradient and area did not differ between groups [2.89 mmHg (IQR 2.26-3.72) vs 2.60 mmHg (IQR 1.91-3.55), P = 0.19 and 1.98 cm2 (IQR 1.66-2.46) vs 2.03 cm2 (IQR 1.55-3.06), P = 0.15]. However, multivariable linear regression analysis demonstrated band annuloplasty as a determinant of larger valve area (coefficient 0.467 cm2, standard error 0.105, P < 0.001). On multivariable analysis, no significant impact on post-repair gradient was observed (-0.370 mmHg, standard error 0.167, P = 0.36). At follow-up, the differences between groups disappeared and multivariable regression analysis failed to demonstrate a significant impact of annuloplasty device type on mitral valve gradient (coefficient -0.095 mmHg, standard error 0.171, P = 1.00) or area (coefficient -0.085 cm2, standard error 0.120, P = 1.00). These results were confirmed with a linear mixed model analysis. CONCLUSIONS: Partial band annuloplasty was related to an improved haemodynamic profile directly after valve repair for degenerative disease but the effect was short-lived. Our results suggest that the type of annuloplasty device has no durable impact on diastolic valve performance.


Assuntos
Fibrilação Atrial , Valva Mitral , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Valva Tricúspide , Catéteres , Hemodinâmica
14.
Eur J Cardiothorac Surg ; 64(5)2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-37610333

RESUMO

OBJECTIVES: Aortic valve repair procedures are technically challenging, and current intraoperative evaluation methods often fail to predict the final echocardiographic result. We have developed a novel intraoperative aortic valve visualization and pressurization (AVP) device, enabling valve inspection under physiological conditions, and measuring aortic valve insufficiency (AI) during cardioplegic arrest. METHODS: The AVP device is attached to the (neo)aorta, after any type of aortic valve repair, while the heart is arrested. The root is pressurized (60-80 mmHg) using a saline solution and an endoscope is introduced. The valve is inspected, and the amount of valvular leakage is measured. Postoperative 'gold standard' transesophageal echocardiogram measurements of AI are performed and compared against regurgitation volume measured. RESULTS: In 24 patients undergoing valve-sparing root replacement, the AVP device was used. In 22 patients, postoperative echocardiographic AI was ≤ grade 1. The median leakage was 90 ml/min, IQR 60-120 ml/min. In 3 patients, additional adjustments after visual inspection was performed. In 2 patients, with complex anatomy, the valve was replaced. In one, after evaluation with the device, there was undesirable result visually and residual AI of 330 ml/min, and in another, 260 ml/min residual AI was measured and valve restriction on visual inspection. CONCLUSIONS: The novel AVP device enables intraoperative evaluation of the valve under physiological conditions, while still on arrested heart, and allows for targeted adjustments. The AVP device can be an important aid for intraoperative evaluation of the aortic valve, during valve repair and valve-sparing procedures, thereby making the operative result more predictable and the operation more efficient.


Assuntos
Insuficiência da Valva Aórtica , Procedimentos Cirúrgicos Cardíacos , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/cirurgia , Aorta/cirurgia , Ecocardiografia , Resultado do Tratamento
15.
PLoS One ; 18(8): e0289412, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37611007

RESUMO

BACKGROUND: INTELLiVENT-Adaptive Support Ventilation (ASV) is a closed-loop ventilation mode that uses capnography to adjust tidal volume (VT) and respiratory rate according to a user-set end-tidal CO2 (etCO2) target range. We compared sidestream versus mainstream capnography with this ventilation mode with respect to the quality of breathing in patients after cardiac surgery. METHODS: Single-center, single-blinded, non-inferiority, randomized clinical trial in adult patients scheduled for elective cardiac surgery that were expected to receive at least two hours of postoperative ventilation in the ICU. Patients were randomized 1:1 to closed-loop ventilation with sidestream or mainstream capnography. Each breath was classified into a zone based on the measured VT, maximum airway pressure, etCO2 and pulse oximetry. The primary outcome was the proportion of breaths spent in a predefined 'optimal' zone of ventilation during the first three hours of postoperative ventilation, with a non-inferiority margin for the difference in the proportions set at -20%. Secondary endpoints included the proportion of breaths in predefined 'acceptable' and 'critical' zones of ventilation, and the proportion of breaths with hypoxemia. RESULTS: Of 80 randomized subjects, 78 were included in the intention-to-treat analysis. We could not confirm the non-inferiority of closed-loop ventilation using sidestream with respect to the proportion of breaths in the 'optimal' zone (mean ratio 0.87 [0.77 to ∞]; P = 0.116 for non-inferiority). The proportion of breaths with hypoxemia was higher in the sidestream capnography group versus the mainstream capnography group. CONCLUSIONS: We could not confirm that INTELLiVENT-ASV using sidestream capnography is non-inferior to INTELLiVENT-ASV using mainstream capnography with respect to the quality of breathing in subjects receiving postoperative ventilation after cardiac surgery. TRIAL REGISTRATION: NCT04599491 (clinicaltrials.gov).


Assuntos
Capnografia , Procedimentos Cirúrgicos Cardíacos , Adulto , Humanos , Respiração , Volume de Ventilação Pulmonar , Hipóxia
16.
Pathol Res Pract ; 248: 154620, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37392550

RESUMO

BACKGROUND: Patients with a bicuspid aortic valve (BAV) have an increased risk to develop aortic complications. Many studies are pointing towards a possible embryonic explanation for the development of both a bicuspid aortic valve as well as a defective ascending aortic wall in these patients. The fetal and newborn ascending aortic wall has however scarcely been studied in bicuspid aortic valve patients. We hypothesize that early histopathological defects might already be visible in the fetal and pediatric ascending aortic wall of bicuspid aortic valve patients, indicating at an early embryonic defect. METHODS: Non-dilated BAV ascending aortic wall samples were collected (n = 40), categorized in five age groups: premature (age range 17.5 weeks + days GA till 37.6 weeks + days GA) 2. neonate (age range 1 - 21 days) 3. infant (age range 1 month - 4 years) 4. adolescent (age range 12 years - 15 years) and 5. adult (age range 41 - 72 years). Specimen were studied for intimal and medial histopathological features. RESULTS: The premature ascending aortic wall has a significantly thicker intimal and significantly thinner medial layer as compared to all other age categories (p < 0.05). After birth the intimal thickness decreases significantly. The medial layer increases in thickness before adulthood (p < 0.05) with an increasing number of elastic lamellae (p < 0.01) and interlamellar mucoid extracellular matrix accumulation (p < 0.0001). Intimal atherosclerosis was scarce and medial histopathological features such as overall medial degeneration, smooth muscle cell nuclei loss and elastic fiber fragmentation were not appreciated in the BAV ascending aortic wall of any age. CONCLUSIONS: The main characteristics of a bicuspid ascending aortic wall are already present before adulthood, albeit not before birth. Considering the early manifestations of ascending aortic wall pathology in bicuspid aortic valve patients, the pediatric population should be considered while searching for markers predictive for future aortopathy.


Assuntos
Doença da Válvula Aórtica Bicúspide , Doenças das Valvas Cardíacas , Adulto , Recém-Nascido , Adolescente , Humanos , Criança , Lactente , Pessoa de Meia-Idade , Idoso , Doença da Válvula Aórtica Bicúspide/complicações , Doença da Válvula Aórtica Bicúspide/patologia , Aorta Torácica/patologia , Valva Aórtica/patologia , Doenças das Valvas Cardíacas/complicações , Doenças das Valvas Cardíacas/patologia , Aorta/patologia
17.
Eur J Cardiothorac Surg ; 64(4)2023 10 04.
Artigo em Inglês | MEDLINE | ID: mdl-37505476

RESUMO

OBJECTIVES: It is unknown which confounding adjustment methods are currently used in the field of cardiothoracic surgery and whether these are appropriately applied. The aim of this study was to systematically evaluate the quality of conduct and reporting of confounding adjustment methods in observational studies on cardiothoracic interventions. METHODS: A systematic review was performed, which included all observational studies that compared different interventions and were published between 1 January and 1 July 2022, in 3 European and American cardiothoracic surgery journals. Detailed information on confounding adjustment methods was extracted and subsequently described. RESULTS: Ninety-two articles were included in the analysis. Outcome regression (n = 49, 53%) and propensity score (PS) matching (n = 44, 48%) were most popular (sometimes used in combination), whereas 11 (12%) studies applied no method at all. The way of selecting confounders was not reported in 42 (46%) of the studies, solely based on previous literature or clinical knowledge in 14 (16%), and (partly) data-driven in 25 (27%). For the studies that applied PS matching, the matched cohorts comprised on average 46% of the entire study population (range 9-82%). CONCLUSIONS: Current reporting of confounding adjustment methods is insufficient in a large part of observational studies on cardiothoracic interventions, which makes quality judgement difficult. Appropriate application of confounding adjustment methods is crucial for causal inference on optimal treatment strategies for clinical practice. Reporting on these methods is an important aspect of this, which can be improved.


Assuntos
Pontuação de Propensão , Humanos , Estudos Observacionais como Assunto
18.
Echocardiography ; 40(9): 892-902, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37519290

RESUMO

AIMS: The present guidelines advise replacing the aortic valve for individuals with severe aortic stenosis (AS) based on various echocardiographic parameters. Accurate measurements are essential to avoid misclassification and unnecessary interventions. The objective of this study was to evaluate the influence of measurement error on the echocardiographic evaluation of the severity of AS. METHODS AND RESULTS: A systematic review was performed to examine whether measurement errors are reported in studies focusing on the prognostic value of peak aortic jet velocity (Vmax ), mean pressure gradient (MPG), and effective orifice area (EOA) in asymptomatic patients with AS. Out of the 37 studies reviewed, 17 (46%) acknowledged the existence of measurement errors, but none of them utilized methods to address them. Secondly, the magnitude of potential errors was collected from available literature for use in clinical simulations. Interobserver variability ranged between 0.9% and 8.3% for Vmax and MPG but was higher for EOA (range 7.7%-12.7%), indicating lower reliability. Assuming a circular left ventricular outflow tract area led to a median underestimation of EOA by 23% compared to planimetry by other modalities. A clinical simulation resulted in the reclassification of 42% of patients, shifting them from a diagnosis of severe AS to moderate AS. CONCLUSIONS: Measurement errors are underreported in studies on echocardiographic assessment of AS severity. These errors can lead to misclassification and misdiagnosis. Clinicians and scientists should be aware of the implications for accurate clinical decision-making and assuring research validity.


Assuntos
Estenose da Valva Aórtica , Humanos , Reprodutibilidade dos Testes , Estenose da Valva Aórtica/diagnóstico por imagem , Ecocardiografia , Valva Aórtica/diagnóstico por imagem , Volume Sistólico , Índice de Gravidade de Doença
19.
BMC Cardiovasc Disord ; 23(1): 363, 2023 07 19.
Artigo em Inglês | MEDLINE | ID: mdl-37468858

RESUMO

INTRODUCTION: Bicuspid aortic valve (BAV) patients have an increased risk to develop thoracic aortic complications. Little is known about the prevalence and severity of atherosclerosis in the BAV ascending aortic wall. This study evaluates and compares the prevalence of thoracic aortic atherosclerosis in BAV and tricuspid aortic valve (TAV) patients. METHODS: Atherosclerosis was objectified using three diagnostic modalities in two separate BAV patient cohorts (with and without an aortic dilatation). Within the first group, atherosclerosis was graded histopathologically according to the modified AHA classification scheme proposed by Virmani et al. In the second group, the calcific load of the ascending aorta and coronary arteries, coronary angiographies and cardiovascular risk factors were studied. Patients were selected from a surgical database (treated between 2006-2020), resulting in a total of 128 inclusions. RESULTS: Histopathology showed atherosclerotic lesions to be more prevalent and severe in all TAV as compared to all BAV patients (OR 1.49 (95%CI 1.14 - 1.94); p = 0.003). Computed tomography showed no significant differences in ascending aortic wall calcification between all BAV and all TAV patients, although a tendency of lower calcific load in favor of BAV was seen. Coronary calcification was higher in all TAV as compared to all BAV (OR 1.30 (95%CI 1.06 - 1.61); p = 0.014). CONCLUSION: Ascending aortic atherosclerotic plaques were histologically more pronounced in TAV as compared to the BAV patients, while CT scans revealed equal amounts of calcific depositions within the ascending aortic wall. This study confirms less atherosclerosis in the ascending aortic wall and coronary arteries of BAV patients as compared to TAV patients. These results were not affected by the presence of a thoracic aortic aneurysm.


Assuntos
Doenças da Aorta , Aterosclerose , Doença da Válvula Aórtica Bicúspide , Doenças das Valvas Cardíacas , Humanos , Doença da Válvula Aórtica Bicúspide/complicações , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/epidemiologia , Doenças das Valvas Cardíacas/complicações , Estudos de Casos e Controles , Valva Aórtica/cirurgia , Doenças da Aorta/diagnóstico por imagem , Doenças da Aorta/epidemiologia , Doenças da Aorta/complicações , Aterosclerose/diagnóstico por imagem , Aterosclerose/epidemiologia
20.
Int J Cardiol ; 387: 131099, 2023 09 15.
Artigo em Inglês | MEDLINE | ID: mdl-37263356

RESUMO

OBJECTIVE: Studies investigating the efficacy of concomitant surgical atrial fibrillation (AF) ablation in hypertrophic obstructive cardiomyopathy (HOCM) patients undergoing myectomy are scarce and limited in terms of sample size. We aim to summarize current outcomes of concomitant surgical AF ablation in HOCM patients undergoing surgical myectomy. METHODS: This systematic review and meta-analysis was performed according to Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. We included all studies reporting any of the following outcomes of concomitant surgical AF ablation in HOCM patients: freedom from recurrence of AF, overall survival and complications. Outcomes were evaluated using traditional meta-analysis at given time-points and using pooled Kaplan-Meier curves. RESULTS: A total of 13 studies were included, resulting in a total of 616 individual patients available for analysis. AF was paroxysmal in 68.1% of the patients (95% CI 56.0-78.2%; I2 = 87.1%; 8 studies, 583 participants). The majority of patients (86.2%) underwent either conventional Cox Maze III or IV (95% CI 39.7-98.3%; I2 = 92.4%; 8 studies, 616 patients) procedure. The incidence of early post-operative pacemaker implantation was 6.1% (95% CI 3.1-11.8%). Overall survival at 3, 5 and 7 years was 95.6% (95% CI 93.4-97.9%), 93.6% (95% CI 90.8-96.5%) and 90.5% (95% CI 86.5-94.6%), respectively. Freedom from recurrent AF at 3, 5 and 7 years was 77.6% (95% CI 73.7-81.7%), 70.6% (95% CI 65.8-75.7) and 63.2% (95% CI 56.2-73.8%), respectively. CONCLUSION: This meta-analysis supports concomitant surgical AF ablation at the time of surgical myectomy in HOCM patients, as it seems to be safe and effective in terminating AF.


Assuntos
Fibrilação Atrial , Cardiomiopatia Hipertrófica , Ablação por Cateter , Humanos , Resultado do Tratamento , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/etiologia , Cardiomiopatia Hipertrófica/diagnóstico , Cardiomiopatia Hipertrófica/cirurgia , Cardiomiopatia Hipertrófica/complicações , Ablação por Cateter/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...