Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
Circulation ; 104(6): 653-7, 2001 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-11489770

RESUMO

BACKGROUND: Coronary artery disease is the major cause of late cardiac allograft failure. However, few data exist regarding the natural history of changes in intimal and external elastic membrane (EEM) areas after heart transplantation. METHODS AND RESULTS: In 38 transplant recipients, serial intravascular ultrasound examinations were performed 3.7+/-2.2 weeks after transplantation and annually thereafter for 5 years. In 59 coronary arteries, we compared 135 matched segments among serial studies. In each segment, intravascular ultrasound images were digitized at 1-mm intervals, and mean values of EEM and lumen and intimal areas were analyzed. In the first year after transplantation, the intimal area increased significantly from 1.8+/-1.6 to 3.0+/-2.1 mm(2) (P<0.001). Subsequently, the annual increase in intimal area decreased. EEM area did not change during the first year; however, between years 1 and 3, significant expansion of EEM area occurred (15.4+/-4.6 to 17.2+/-5.4 mm(2), P<0.001). Thereafter, EEM area decreased significantly from 17.2+/-5.4 mm(2) (year 3) to 15.1+/-4.9 mm(2) (year 5, P=0.01). Different mechanisms of lumen loss were observed during 2 phases after transplantation: early lumen loss primarily caused by intimal thickening and late lumen loss caused by EEM area constriction. CONCLUSIONS: This serial ultrasound study revealed that most of the intimal thickening occurred during the first year after heart transplantation. Changes in the EEM area showed a biphasic response, consisting of early expansion and late constriction. Thus, different mechanisms of lumen loss were observed during the early and late phases after transplantation.


Assuntos
Doença das Coronárias/patologia , Transplante de Coração , Túnica Íntima/patologia , Adulto , Constrição Patológica , Doença das Coronárias/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo , Túnica Íntima/diagnóstico por imagem , Ultrassonografia de Intervenção
3.
IEEE Trans Med Imaging ; 19(10): 996-1011, 2000 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-11131497

RESUMO

Intravascular ultrasound (IVUS) provides direct depiction of coronary artery anatomy, including plaque and vessel area, which is important in quantitative studies on the progression or regression of coronary artery disease. Traditionally, these studies have relied on manual evaluation, which is laborious, time consuming, and subject to large interobserver and intraobserver variability. A new technique, called active surface segmentation, alleviates these limitations and makes strides toward routine analyses. However, for three-dimensional (3-D) plaque assessment or 3-D reconstruction to become a clinical reality, methods must be developed which can analyze many images quickly. Presented is a comparison between two active surface techniques for three-dimensional segmentation of luminal and medial-adventitial borders. The force-acceleration technique and the neighborhood-search technique accurately detected both borders in vivo (r2 = 0.95 and 0.99, Williams' index = 0.67 and 0.65, and r2 = 0.95 and 0.99, WI = 0.67 and 0.70, respectively). However, the neighborhood-search technique was significantly faster and required less computation. Volume calculations for both techniques (r2 = 0.99 and r2 = 0.99) also agreed with a known-volume phantom. Active surface segmentation allows 3-D assessment of coronary morphology and further developments with this technology will provide clinical analysis tools.


Assuntos
Algoritmos , Vasos Coronários/diagnóstico por imagem , Imageamento Tridimensional , Ultrassonografia de Intervenção , Doença das Coronárias/diagnóstico por imagem , Humanos , Técnicas In Vitro , Imagens de Fantasmas , Túnica Média/diagnóstico por imagem
4.
Int J Card Imaging ; 16(2): 87-98, 2000 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-10928343

RESUMO

Several techniques have been used to demonstrate that human arteries respond to atherosclerosis by increasing their total arterial area to prevent a decrease in blood flow. Three-dimensional reconstructions of coronary arteries can document this compensatory response accurately and specifically. Seven human coronary arteries were reconstructed using intravascular ultrasound and biplane angiography, and vessel geometries were quantified. In all seven vessels, as plaque area increased, overall vessel area increased (R = 0.986, 0.933, 0.984, 0.678, 0.763, 0.963, and 0.830), but luminal cross-sectional area did not significantly decrease. Focal compensatory enlargement was identified in each vessel, and in some cases this response appeared to occur until the vessel was 65% occluded. Luminal enlargement near the proximal ends was attributed to the natural taper of the vessel. The semi-automated, three-dimensional segmentation technique used in this study allows reproducible quantification, as there is no subjective manual tracing involved. Following the intravascular ultrasound transducer in time and space with biplane angiography allows for accurate reconstruction with or without automated pullback devices. Information on the rate of change of vessel measurements is also presented, which, when combined with visualization of accurate 3D geometry, provides a unique assessment of coronary compensatory enlargement. This reconstruction technique can be applied in a clinical environment with no major modification.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Ultrassonografia de Intervenção/métodos , Adulto , Idoso , Técnicas de Cultura , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Índice de Gravidade de Doença
5.
Z Kardiol ; 89 Suppl 2: 92-100, 2000.
Artigo em Inglês | MEDLINE | ID: mdl-10769410

RESUMO

UNLABELLED: This paper describes our research into the vascular mechanics of the coronary artery and plaque. The three sections describe the determination of arterial mechanical properties using intravascular ultrasound (IVUS), a constitutive relation for the arterial wall, and finite element method (FEM) models of the arterial wall and atheroma. METHODS: Inflation testing of porcine left anterior descending coronary arteries was conducted. The changes in the vessel geometry were monitored using IVUS, and intracoronary pressure was recorded using a pressure transducer. The creep and quasistatic stress/strain responses were determined. A Standard Linear Solid (SLS) was modified to reproduce the non-linear elastic behavior of the arterial wall. This Standard Non-linear Solid (SNS) was implemented into an axisymetric thick-walled cylinder numerical model. Finite element analysis models were created for five age groups and four levels of stenosis using the Pathobiological Determinants of Atherosclerosis Youth (PDAY) database. RESULTS: The arteries exhibited non-linear elastic behavior. The total tissue creep strain was epsilon creep = 0.082 +/- 0.018 mm/mm. The numerical model could reproduce both the non-linearity of the porcine data and time dependent behavior of the arterial wall found in the literature with a correlation coefficient of 0.985. Increasing age had a strong positive correlation with the shoulder stress level, (r = 0.95). The 30% stenosis had the highest shoulder stress due to the combination of a fully formed lipid pool and a thin cap. CONCLUSIONS: Studying the solid mechanics of the arterial wall and the atheroma provide important insights into the mechanisms involved in plaque rupture.


Assuntos
Doença da Artéria Coronariana/fisiopatologia , Vasos Coronários/fisiopatologia , Animais , Fenômenos Biomecânicos , Simulação por Computador , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Elasticidade , Endossonografia , Análise de Elementos Finitos , Dinâmica não Linear , Suínos
SELEÇÃO DE REFERÊNCIAS