J Otolaryngol Head Neck Surg ; 53: 19160216241248669, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38903014

RESUMO

BACKGROUND: Minimally invasive cochlear implant surgery by using a microstereotactic frame demands solid connection to the bone. We aimed to determine the stability of commercially available orthodontic miniscrews to evaluate their feasibility for frame's fixation. In addition, which substitute material most closely resembles the mechanical properties of the human temporal bone was evaluated. METHODS: Pull-out tests were carried out with five different types of orthodontic miniscrews in human temporal bone specimens. Furthermore, short fiber filled epoxy (SFFE), solid rigid polyurethane (SRPU50), bovine femur, and porcine iliac bone were evaluated as substitute materials. In total, 57 tests in human specimens and 180 tests in the substitute materials were performed. RESULTS: In human temporal bone, average pull-out forces ranged from 220 N to 285 N between screws. Joint stiffness in human temporal bone ranged between 14 N/mm and 358 N/mm. Statistically significant differences between the tested screws were measured in terms of stiffness and elastic energy. One screw type failed insertion due to tip breakage. No significant differences occurred between screws in maximum pull-out force. The average pull-out values of SFFE were 14.1 N higher compared to human specimen. CONCLUSION: Orthodontic miniscrews provided rigid fixation when partially inserted in human temporal bone, as evidenced by pull-out forces and joint stiffness. Average values exceeded requirements despite variations between screws. Differences in stiffness and elastic energy indicate screw-specific interface mechanics. With proper insertion, orthodontic miniscrews appear suitable for microstereotactic frame anchoring during minimally invasive cochlear implant surgery. However, testing under more complex loading is needed to better predict clinical performance. For further pull-out tests, the most suitable substitute material is SFFE.


Assuntos
Parafusos Ósseos , Osso Temporal , Osso Temporal/cirurgia , Humanos , Animais , Suínos , Implante Coclear/métodos , Teste de Materiais , Cadáver , Bovinos , Procedimentos Cirúrgicos Minimamente Invasivos
2.
IEEE Trans Biomed Eng ; 70(1): 390-398, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-35939462

RESUMO

OBJECTIVES: Drilling a minimally invasive access to the inner ear is a demanding task in which a computer-assisted surgical system can support the surgeon. Herein, we describe the design of a new micro-stereotactic targeting system dedicated to cochlear implant (CI) surgery and its experimental evaluation in an ex vivo study. METHODS: The proposed system consists of a reusable, bone-anchored reference frame, and a patient-specific drilling jig on top of it. Individualization of the jig is simplified to a single counterbored hole drilled out of a blank. For accurate counterboring, the setup includes a manufacturing device for individual positioning of the blank. The system was tested in a preclinical setting using twelve human cadaver donors. Cone beam computed tomograph (CBCT) scans were obtained and a drilling trajectory was planned pointing towards the basal part of the cochlea. The surgical drill was moved forward manually and slowly while the jig constrained the drill along the predetermined path. RESULTS: Drilling could be performed with preservation of facial nerve in all specimens. The mean error caused by the system at the target point in front of the cochlea was 0.30 mm ± 0.11 mm including an inaccuracy of 0.09 mm ± 0.03 mm for counterboring the guiding aperture into the jig. CONCLUSION: Feasibility of the proposed system to perform a minimally invasive posterior tympanotomy approach was shown successfully in all specimens. SIGNIFICANCE: First evaluation of the new system in a comprehensive ex vivo study demonstrating sufficient accuracy and the feasibility of the whole concept.


Assuntos
Implante Coclear , Implantes Cocleares , Cirurgia Assistida por Computador , Humanos , Procedimentos Cirúrgicos Minimamente Invasivos , Cóclea/diagnóstico por imagem , Cóclea/cirurgia
3.
Front Neurol ; 13: 829478, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35547379

RESUMO

A minimally-invasive surgical (MIS) approach to cochlear implantation, if safe, practical, simple in surgical handling, and also affordable has the potential to replace the conventional surgical approaches. Our MIS approach uses patient-specific drilling templates (positioning jigs). While the most popular MIS approaches use robots, the robotic aspect is literally put aside, because our high-precision parallel kinematics is only used to individualize a positioning jig. This jig can then be mounted onto a bone-anchored mini-stereotactic frame at the patient's skull and used to create a drill-hole through the temporal bone to the patient's cochlea. We present the first clinical experience where we use sham drill bits of different diameters instead of drilling into the bone in order to demonstrate the feasibility and accuracy.

4.
Polymers (Basel) ; 12(4)2020 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-32331487

RESUMO

In the field of polymer chemistry, tremendous efforts have been made over the lastdecade to replace petrochemical monomers with building blocks from renewable resources. In thisrespect, itaconic acid has been used as an alternative to acrylic acid or maleic acid in unsaturatedpolyesters for thermal or UV-curing applications. However, examples of poly(ester amide)s fromitaconic acid are scarce. Under standard polycondensation reactions, the presence of free aminesleads to aza-Michael addition reactions at the α,ß-unsaturated double bond of the itaconic acid andisomerization reactions to mesaconic acid. Both reactions make the resulting materials useless asUV-curing polymer resins. To avoid these undesired side reactions, we herein report the use ofpreformed, well-defined diols containing internal amide bonds. The resulting unsaturatedpoly(ester amide) resins were analyzed before and after UV-induced crosslinking. Viscositymeasurements revealed a strong thixotropic behavior induced by the amide groups, which isusually not detected in structurally similar polyester resins.

5.
Int J Comput Assist Radiol Surg ; 14(8): 1389-1401, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31168671

RESUMO

PURPOSE: Minimally invasive cochlear implant surgery is a challenging procedure due to high demands on accuracy. For clinical success, an according assistance system has to compete against the traditional approach in terms of risk, operating time and cost. It has not yet been determined what kind of system is the most suited. The purpose of this study is a proof of concept of surgical process modeling as a preclinical development tool and the comparison of workflow concepts for this new approach. METHODS: Three preclinical systems (two stereotactic and one robotic) for minimally invasive cochlear implant surgery are compared using the method of surgical process modeling. All three systems were successfully tested with ex vivo human specimen to create minimally invasive surgical access to the cochlea. Those systems where chosen for comparison, because they represent three diverse approaches with different corresponding workflows for the same intervention. The experiments were used to create a process model for each system by recording the interventions. RESULTS: All three conceptual systems developed by our group have shown their eligibility. The recorded process models provide a convenient method for direct comparison. Reduction in the surgical time has a higher impact on the process, than time that is needed for setting up a system beforehand. The stereotactic approaches have little preparation effort and are low cost in terms of hardware compared to the robotic approach, which in return is beneficial in terms of workload reduction for the surgeon. CONCLUSION: Surgical process modeling is suitable for comparison of different assistant systems for minimally invasive cochlear implantation. The benefit of reduced trauma, compared to the traditional mastoidectomy, can now be assessed with consideration of the workflow of each technique. The process models enable an assessment in the regard of surgical time and workload.


Assuntos
Cóclea/cirurgia , Implante Coclear/métodos , Implantes Cocleares , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Fluxo de Trabalho , Algoritmos , Cadáver , Simulação por Computador , Desenho de Equipamento , Humanos , Robótica , Gravação em Vídeo
6.
Eur Arch Otorhinolaryngol ; 275(5): 1077-1085, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29532169

RESUMO

PURPOSE: Patient specific selection of cochlear implants would benefit from pre-operative knowledge of cochlear length. Several methods for its measurement or estimation have been described in literature. This study focused on the achievable accuracy in clinically available imaging. METHODS: Five simplified cochlea models milled into porcine bone were scanned in water using clinical cone beam computed tomography. Due to their well-known dimensions these phantoms served as gold standard for the length measurements. Each phantom was measured ten times using the custom software Comet. In addition, cochleae in ten image datasets taken indiscriminately from clinical routine were measured ten times each to test the precision under realistic conditions. The results were also compared to estimations based on the diameter of the basal turn (A value) as described in literature. RESULTS: Measurement accuracy of the phantoms' lengths was high (average error: - 0.2 mm; standard deviation: 0.3 mm). The pooled standard deviation for the measurements in clinical datasets was 0.6 mm. Errors resulted mainly from problems locating the helicotrema. The estimations differed on average - 1.7 to + 0.4 mm from the manual measurements and had standard deviations between 0.5 and 0.6 mm depending on the algorithm. CONCLUSIONS: The program Comet was successfully used to accurately measure the length of the cochlea models in clinically available imaging. The lower image quality of patient scans reduced the precision of the measurement. Estimations using the A value are a quicker alternative for averagely sized cochleae in cases where the lack of accuracy is tolerable.


Assuntos
Ducto Coclear/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Animais , Ducto Coclear/anatomia & histologia , Implante Coclear/instrumentação , Implantes Cocleares , Humanos , Modelos Anatômicos , Imagens de Fantasmas , Software , Suínos
7.
Polymers (Basel) ; 9(12)2017 Dec 09.
Artigo em Inglês | MEDLINE | ID: mdl-30965993

RESUMO

Bio-based unsaturated polyester resins derived from itaconic acid can be an alternative to established resins of this type in the field of radical-curing resins. However, one of the challenges of these polyester itaconates is the somewhat more elaborate synthetic process, especially under polycondensation conditions used on an industrial scale. The α,ß-unsaturated double bond of the itaconic acid is prone to side reactions that can lead to the gelation of the polyester resin under standard conditions. This is especially true when bio-based diols such as 1,3-propanediol or 1,4-butanediol are used to obtain resins that are 100% derived from renewable resources. It was observed in earlier studies that high amounts of these aliphatic diols in the polyester lead to low conversion and gelation of the resins. In this work, a catalytic study using different diols was performed in order to elucidate the reasons for this behavior. It was shown that the choice of catalyst has a crucial influence on the side reactions occurring during the polycondensation reactions. In addition, the side reactions taking place were identified and suppressed. These results will allow for the synthesis of polyester itaconates on a larger scale, setting the stage for their industrial application.

8.
Eur Arch Otorhinolaryngol ; 273(11): 3573-3585, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26961519

RESUMO

The integration of a shape memory actuator is a potential mechanism to achieve a consistent perimodiolar position after electrode insertion during cochlear implant surgery. After warming up, and therefore activation of the shape memory effect, the electrode array will change from a straight configuration into a spiral shaped one leading to a final position close to the modiolus. The aim of this study was to investigate whether the integration of an additional thin wire (referred to as an "inlay") made of Nitinol, a well-established shape memory alloy, in a conventional hearing preservation electrode array will affect the insertion behaviour in terms of increased risk of insertion trauma. Six conventional Hybrid-L electrode arrays (Cochlear Ltd., Sydney, Australia) were modified to incorporate a wire inlay made of Nitinol. The diameter of the wires was 100 µm with a tapered tip region. Electrodes were inserted into human temporal bone specimens using a standard surgical approach. After insertion and embedding in epoxy resin, histological sections were prepared to evaluate insertion trauma. Insertion was straightforward and no difficulties were observed. The addition of a shape memory wire, thin but also strong enough to curl the electrode array, does not result in histologically detectable insertion trauma. Atraumatic insertion seems possible.


Assuntos
Ligas , Implante Coclear/métodos , Implantes Cocleares , Osso Temporal/cirurgia , Cadáver , Implante Coclear/efeitos adversos , Humanos , Complicações Intraoperatórias/etiologia , Complicações Intraoperatórias/prevenção & controle , Desenho de Prótese