Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 188
Filtrar
1.
Rev Sci Instrum ; 94(8)2023 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38065184

RESUMO

An x-ray imaging scheme using spherically bent crystals was implemented on the Z-machine to image x rays emitted by the hot, dense plasma generated by a Magnetized Liner Inertial Fusion (MagLIF) target. This diagnostic relies on a spherically bent crystal to capture x-ray emission over a narrow spectral range (<15 eV), which is established by a limiting aperture placed on the Rowland circle. The spherical crystal optic provides the necessary high-throughput and large field-of-view required to produce a bright image over the entire, one-cm length of the emitting column of a plasma. The average spatial resolution was measured and determined to be 18 µm for the highest resolution configuration. With this resolution, the radial size of the stagnation column can be accurately determined and radial structures, such as bifurcations in the column, are clearly resolved. The success of the spherical-crystal imager has motivated the implementation of a new, two-crystal configuration for identifying sources of spectral line emission using a differential imaging technique.

2.
Rev Sci Instrum ; 94(6)2023 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-37862494

RESUMO

Bayesian analysis enables flexible and rigorous definition of statistical model assumptions with well-characterized propagation of uncertainties and resulting inferences for single-shot, repeated, or even cross-platform data. This approach has a strong history of application to a variety of problems in physical sciences ranging from inference of particle mass from multi-source high-energy particle data to analysis of black-hole characteristics from gravitational wave observations. The recent adoption of Bayesian statistics for analysis and design of high-energy density physics (HEDP) and inertial confinement fusion (ICF) experiments has provided invaluable gains in expert understanding and experiment performance. In this Review, we discuss the basic theory and practical application of the Bayesian statistics framework. We highlight a variety of studies from the HEDP and ICF literature, demonstrating the power of this technique. Due to the computational complexity of multi-physics models needed to analyze HEDP and ICF experiments, Bayesian inference is often not computationally tractable. Two sections are devoted to a review of statistical approximations, efficient inference algorithms, and data-driven methods, such as deep-learning and dimensionality reduction, which play a significant role in enabling use of the Bayesian framework. We provide additional discussion of various applications of Bayesian and machine learning methods that appear to be sparse in the HEDP and ICF literature constituting possible next steps for the community. We conclude by highlighting community needs, the resolution of which will improve trust in data-driven methods that have proven critical for accelerating the design and discovery cycle in many application areas.

3.
Rev Sci Instrum ; 94(5)2023 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-37129462

RESUMO

Accurate understanding of x-ray diagnostics is crucial for both interpreting high-energy-density experiments and testing simulations through quantitative comparisons. X-ray diagnostic models are complex. Past treatments of individual x-ray diagnostics on a case-by-case basis have hindered universal diagnostic understanding. Here, we derive a general formula for modeling the absolute response of non-focusing x-ray diagnostics, such as x-ray imagers, one-dimensional space-resolved spectrometers, and x-ray power diagnostics. The present model is useful for both data modeling and data processing. It naturally accounts for the x-ray crystal broadening. The new model verifies that standard approaches for a crystal response can be good approximations, but they can underestimate the total reflectivity and overestimate spectral resolving power by more than a factor of 2 in some cases near reflectivity edge features. We also find that a frequently used, simplified-crystal-response approximation for processing spectral data can introduce an absolute error of more than an order of magnitude and the relative spectral radiance error of a factor of 3. The present model is derived with straightforward geometric arguments. It is more general and is recommended for developing a unified picture and providing consistent treatment over multiple x-ray diagnostics. Such consistency is crucial for reliable multi-objective data analyses.

4.
Rev Sci Instrum ; 94(5)2023 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-37184347

RESUMO

We report on progress implementing and testing cryogenically cooled platforms for Magnetized Liner Inertial Fusion (MagLIF) experiments. Two cryogenically cooled experimental platforms were developed: an integrated platform fielded on the Z pulsed power generator that combines magnetization, laser preheat, and pulsed-power-driven fuel compression and a laser-only platform in a separate chamber that enables measurements of the laser preheat energy using shadowgraphy measurements. The laser-only experiments suggest that ∼89% ± 10% of the incident energy is coupled to the fuel in cooled targets across the energy range tested, significantly higher than previous warm experiments that achieved at most 67% coupling and in line with simulation predictions. The laser preheat configuration was applied to a cryogenically cooled integrated experiment that used a novel cryostat configuration that cooled the MagLIF liner from both ends. The integrated experiment, z3576, coupled 2.32 ± 0.25 kJ preheat energy to the fuel, the highest to-date, demonstrated excellent temperature control and nominal current delivery, and produced one of the highest pressure stagnations as determined by a Bayesian analysis of the data.

5.
Rev Sci Instrum ; 92(7): 073507, 2021 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-34340441

RESUMO

The very short burn time and small size of burning plasmas created at advanced laser-fusion facilities will require high-spatial-resolution imaging diagnostics with fast time resolution. These instruments will need to function in an environment of extremely large neutron fluxes that will cause conventional diagnostics to fail because of radiation damage and induced background levels. One solution to this challenge is to perform an ultrafast conversion of the x-ray signals into the optical regime before the neutrons are able to reach the detector and then to relay image the signal out of the chamber and into a shielded bunker, protected from the effects of these neutrons. With this goal in mind, the OMEGA laser was used to demonstrate high-temporal-resolution x-ray imaging by using an x-ray snout to image an imploding backlighter capsule onto a semiconductor. The semiconductor was simultaneously probed with the existing velocity interferometry system for any surface reflector (VISAR) diagnostic, which uses an optical streak camera and provided a one-dimensional image of the phase in the semiconductor as a function of time. The phase induced in the semiconductor was linearly proportional to the x-ray emission from the backlighter capsule. This approach would then allow a sacrificial semiconductor to be attached at the end of an optical train with the VISAR and optical streak camera placed in a shielded bunker to operate in a high neutron environment and obtain time-dependent one-dimensional x-ray images or time-dependent x-ray spectra from a burning plasma.

6.
Nature ; 592(7852): 35-42, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33790445

RESUMO

The photon-the quantum excitation of the electromagnetic field-is massless but carries momentum. A photon can therefore exert a force on an object upon collision1. Slowing the translational motion of atoms and ions by application of such a force2,3, known as laser cooling, was first demonstrated 40 years ago4,5. It revolutionized atomic physics over the following decades6-8, and it is now a workhorse in many fields, including studies on quantum degenerate gases, quantum information, atomic clocks and tests of fundamental physics. However, this technique has not yet been applied to antimatter. Here we demonstrate laser cooling of antihydrogen9, the antimatter atom consisting of an antiproton and a positron. By exciting the 1S-2P transition in antihydrogen with pulsed, narrow-linewidth, Lyman-α laser radiation10,11, we Doppler-cool a sample of magnetically trapped antihydrogen. Although we apply laser cooling in only one dimension, the trap couples the longitudinal and transverse motions of the anti-atoms, leading to cooling in all three dimensions. We observe a reduction in the median transverse energy by more than an order of magnitude-with a substantial fraction of the anti-atoms attaining submicroelectronvolt transverse kinetic energies. We also report the observation of the laser-driven 1S-2S transition in samples of laser-cooled antihydrogen atoms. The observed spectral line is approximately four times narrower than that obtained without laser cooling. The demonstration of laser cooling and its immediate application has far-reaching implications for antimatter studies. A more localized, denser and colder sample of antihydrogen will drastically improve spectroscopic11-13 and gravitational14 studies of antihydrogen in ongoing experiments. Furthermore, the demonstrated ability to manipulate the motion of antimatter atoms by laser light will potentially provide ground-breaking opportunities for future experiments, such as anti-atomic fountains, anti-atom interferometry and the creation of antimatter molecules.

7.
Phys Rev Lett ; 125(15): 155002, 2020 Oct 09.
Artigo em Inglês | MEDLINE | ID: mdl-33095639

RESUMO

We present experimental results from the first systematic study of performance scaling with drive parameters for a magnetoinertial fusion concept. In magnetized liner inertial fusion experiments, the burn-averaged ion temperature doubles to 3.1 keV and the primary deuterium-deuterium neutron yield increases by more than an order of magnitude to 1.1×10^{13} (2 kJ deuterium-tritium equivalent) through a simultaneous increase in the applied magnetic field (from 10.4 to 15.9 T), laser preheat energy (from 0.46 to 1.2 kJ), and current coupling (from 16 to 20 MA). Individual parametric scans of the initial magnetic field and laser preheat energy show the expected trends, demonstrating the importance of magnetic insulation and the impact of the Nernst effect for this concept. A drive-current scan shows that present experiments operate close to the point where implosion stability is a limiting factor in performance, demonstrating the need to raise fuel pressure as drive current is increased. Simulations that capture these experimental trends indicate that another order of magnitude increase in yield on the Z facility is possible with additional increases of input parameters.

8.
Int J Biometeorol ; 63(9): 1217-1229, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31209601

RESUMO

We examined relationships between wintertime Arctic sea-ice extent (ASIE) and radial growth rates of alpine larch trees (LALY) in the northern Rockies, USA, during 1979-2015 (r = - 0.71, p < 0.01) and reconstructed ASIE fluctuations from 1613 to 2015. Wintertime ASIE corresponds with summertime mid-latitude upper-level atmospheric flow patterns with ridging (troughing) and warmer (cooler) conditions prevailing in the Rockies when ASIE are below (above) average. In turn, warmer (cooler) summertime conditions favor (disfavor) growth of LALY, thus "recording" interannual variations in ASIE. Both 1000 hPa temperatures and 500 hPa geopotential heights during years of anomalously high or low radial growth negatively correspond with ASIE, suggesting that a disjunct spatial influence on atmospheric conditions may be associated with interannual variability of ASIE. Reconstructed ASIE values show that 1996-2015 was the lowest 20-year period on record, but the mean value is not significantly different from six other distinct periods of below-average ASIE.


Assuntos
Larix , Árvores , Regiões Árticas , Clima , Temperatura
9.
BMC Complement Altern Med ; 19(1): 85, 2019 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-30975140

RESUMO

BACKGROUND: In 2011 there was a strengthening of European Union (EU) legislation on the licencing of herbal products which, in the UK, resulted in the introduction of the Traditional Herbal Registration (THR) scheme. This scheme sets out standards for the safety and quality of herbal medicines and includes the provision of information to the customer on the safe use of the product. The aim of this study is to replicate a survey undertaken in 2011, prior to the implementation of the THR scheme, and evaluate the impact of this scheme on the information provided with herbal products bought over-the-counter. METHODS: We undertook a survey on 5 herbal products commonly available over-the-counter (St John's wort, echinacea, Ginkgo biloba, Asian ginseng, garlic). The information was searched for key safety messages identified by the National Center for Complementary and Integrative Health (NCCIH). We also explored the presence of risk of harm information. RESULTS: We recorded a rise in the number of products registered with the THR scheme (37% in 2016 compared to 7% in 2011). We also identified a reduction in the number of products that did not contain key safety information (75% in 2011 compared to 20% of products obtained in 2016). Risk of harm information was only communicated in products containing a PIL. We identified more products containing frequency of risk of harm information but this was not statistically significant. CONCLUSION: The introduction of the THR scheme appears to be associated with an increase in the provision of information about key safety messages on the safe use of herbal products. However, it is important to note that at least half of the products on the market that are not included in the THR scheme do not contain any information about their safe use; this includes information about precautions, interactions and side effects. The use of NCCIH herbal monographs replicated the methods used in the previous study; we recognise that the use of a different resource might effect the appraisal of the information provided. We also acknowledge that surveying presence of information does not assure that the latter is effectively communicated to patients, for which a close textual analysis would be required. While it is promising that more information is available after the introduction of the THR scheme, the public needs to be informed about ways to optimise safe use of all herbal products.


Assuntos
Bases de Dados de Produtos Farmacêuticos , Rotulagem de Medicamentos/estatística & dados numéricos , Medicamentos sem Prescrição , Preparações de Plantas , Sistema de Registros , Humanos , Segurança do Paciente , Reino Unido
10.
Nature ; 561(7722): 211-215, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-30135588

RESUMO

In 1906, Theodore Lyman discovered his eponymous series of transitions in the extreme-ultraviolet region of the atomic hydrogen spectrum1,2. The patterns in the hydrogen spectrum helped to establish the emerging theory of quantum mechanics, which we now know governs the world at the atomic scale. Since then, studies involving the Lyman-α line-the 1S-2P transition at a wavelength of 121.6 nanometres-have played an important part in physics and astronomy, as one of the most fundamental atomic transitions in the Universe. For example, this transition has long been used by astronomers studying the intergalactic medium and testing cosmological models via the so-called 'Lyman-α forest'3 of absorption lines at different redshifts. Here we report the observation of the Lyman-α transition in the antihydrogen atom, the antimatter counterpart of hydrogen. Using narrow-line-width, nanosecond-pulsed laser radiation, the 1S-2P transition was excited in magnetically trapped antihydrogen. The transition frequency at a field of 1.033 tesla was determined to be 2,466,051.7 ± 0.12 gigahertz (1σ uncertainty) and agrees with the prediction for hydrogen to a precision of 5 × 10-8. Comparisons of the properties of antihydrogen with those of its well-studied matter equivalent allow precision tests of fundamental symmetries between matter and antimatter. Alongside the ground-state hyperfine4,5 and 1S-2S transitions6,7 recently observed in antihydrogen, the Lyman-α transition will permit laser cooling of antihydrogen8,9, thus providing a cold and dense sample of anti-atoms for precision spectroscopy and gravity measurements10. In addition to the observation of this fundamental transition, this work represents both a decisive technological step towards laser cooling of antihydrogen, and the extension of antimatter spectroscopy to quantum states possessing orbital angular momentum.

11.
Nature ; 557(7703): 71-75, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29618820

RESUMO

In 1928, Dirac published an equation 1 that combined quantum mechanics and special relativity. Negative-energy solutions to this equation, rather than being unphysical as initially thought, represented a class of hitherto unobserved and unimagined particles-antimatter. The existence of particles of antimatter was confirmed with the discovery of the positron 2 (or anti-electron) by Anderson in 1932, but it is still unknown why matter, rather than antimatter, survived after the Big Bang. As a result, experimental studies of antimatter3-7, including tests of fundamental symmetries such as charge-parity and charge-parity-time, and searches for evidence of primordial antimatter, such as antihelium nuclei, have high priority in contemporary physics research. The fundamental role of the hydrogen atom in the evolution of the Universe and in the historical development of our understanding of quantum physics makes its antimatter counterpart-the antihydrogen atom-of particular interest. Current standard-model physics requires that hydrogen and antihydrogen have the same energy levels and spectral lines. The laser-driven 1S-2S transition was recently observed 8 in antihydrogen. Here we characterize one of the hyperfine components of this transition using magnetically trapped atoms of antihydrogen and compare it to model calculations for hydrogen in our apparatus. We find that the shape of the spectral line agrees very well with that expected for hydrogen and that the resonance frequency agrees with that in hydrogen to about 5 kilohertz out of 2.5 × 1015 hertz. This is consistent with charge-parity-time invariance at a relative precision of 2 × 10-12-two orders of magnitude more precise than the previous determination 8 -corresponding to an absolute energy sensitivity of 2 × 10-20 GeV.

12.
Rev Sci Instrum ; 88(10): 103503, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29092482

RESUMO

Many experiments on Sandia National Laboratories' Z Pulsed Power Facility-a 30 MA, 100 ns rise-time, pulsed-power driver-use a monochromatic quartz crystal backlighter system at 1.865 keV (Si Heα) or 6.151 keV (Mn Heα) x-ray energy to radiograph an imploding liner (cylindrical tube) or wire array z-pinch. The x-ray source is generated by the Z-Beamlet laser, which provides two 527-nm, 1 kJ, 1-ns laser pulses. Radiographs of imploding, thick-walled beryllium liners at convergence ratios CR above 15 [CR=ri(0)/ri(t)] using the 6.151-keV backlighter system were too opaque to identify the inner radius ri of the liner with high confidence, demonstrating the need for a higher-energy x-ray radiography system. Here, we present a 7.242 keV backlighter system using a Ge(335) spherical crystal with the Co Heα resonance line. This system operates at a similar Bragg angle as the existing 1.865 keV and 6.151 keV backlighters, enhancing our capabilities for two-color, two-frame radiography without modifying the system integration at Z. The first data taken at Z include 6.2-keV and 7.2-keV two-color radiographs as well as radiographs of low-convergence (CR about 4-5), high-areal-density liner implosions.

13.
Rev Sci Instrum ; 88(1): 013504, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28147637

RESUMO

We describe the design and function of a new time and space resolved x-ray spectrometer for use in Z-pinch inertial confinement fusion and radiation source development experiments. The spectrometer is designed to measure x-rays in the range of 0.5-1.5 Å (8-25 keV) with a spectral resolution λ/Δλ ∼ 400. The purpose of this spectrometer is to measure the time- and one-dimensional space-dependent electron temperature and density during stagnation. These relatively high photon energies are required to escape the dense plasma created at stagnation and to obtain sensitivity to electron temperatures ≳3 keV. The spectrometer is of the Cauchois type, employing a large 30 × 36 mm2, transmissive quartz optic for which a novel solid beryllium holder was designed. The performance of the crystal was verified using offline tests, and the integrated system was tested using experiments on the Z pulsed power accelerator.

14.
Neurogastroenterol Motil ; 27(4): 468-80, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25703354

RESUMO

BACKGROUND: Gastrointestinal (GI) dysfunction is a major cause of morbidity in acquired immunodeficiency syndrome (AIDS). HIV-1-induced neuropathogenesis is significantly enhanced by opiate abuse, which increases proinflammatory chemokine/cytokine release, the production of reactive species, glial reactivity, and neuronal injury in the central nervous system. Despite marked interactions in the gut, little is known about the effects of HIV-1 in combination with opiate use on the enteric nervous system. METHODS: To explore HIV-opiate interactions in myenteric neurons, the effects of Tat ± morphine (0.03, 0.3, and 3 µM) were examined in isolated neurons from doxycycline- (DOX-) inducible HIV-1 Tat(1-86) transgenic mice or following in vitro Tat 100 nM exposure (>6 h). KEY RESULTS: Current clamp recordings demonstrated increased neuronal excitability in neurons of inducible Tat(+) mice (Tat+/DOX) compared to control Tat-/DOX mice. In neurons from Tat+/DOX, but not from Tat-/DOX mice, 0.03 µM morphine significantly reduced neuronal excitability, fast transient and late long-lasting sodium currents. There was a significant leftward shift in V(0.5) of inactivation following exposure to 0.03 µM morphine, with a 50% decrease in availability of sodium channels at -100 mV. Similar effects were noted with in vitro Tat exposure in the presence of 0.3 µM morphine. Additionally, GI motility was significantly more sensitive to morphine in Tat(+) mice than Tat(-) mice. CONCLUSIONS & INFERENCES: Overall, these data suggest that the sensitivity of enteric neurons to morphine is enhanced in the presence of Tat. Opiates and HIV-1 may uniquely interact to exacerbate the deleterious effects of HIV-1-infection and opiate exposure on GI function.


Assuntos
Sensibilização do Sistema Nervoso Central/efeitos dos fármacos , Sistema Nervoso Entérico/efeitos dos fármacos , Morfina/toxicidade , Neurônios/efeitos dos fármacos , Produtos do Gene tat do Vírus da Imunodeficiência Humana/toxicidade , Animais , Células Cultivadas , Sistema Nervoso Entérico/fisiopatologia , Motilidade Gastrointestinal/efeitos dos fármacos , Íleo/metabolismo , Camundongos , Camundongos Transgênicos , Neurônios/fisiologia , Receptores Opioides mu/metabolismo , Canais de Sódio/metabolismo , Produtos do Gene tat do Vírus da Imunodeficiência Humana/genética
15.
Phys Rev Lett ; 113(15): 155003, 2014 Oct 10.
Artigo em Inglês | MEDLINE | ID: mdl-25375714

RESUMO

This Letter presents results from the first fully integrated experiments testing the magnetized liner inertial fusion concept [S. A. Slutz et al., Phys. Plasmas 17, 056303 (2010)], in which a cylinder of deuterium gas with a preimposed 10 Taxial magnetic field is heated by Z beamlet, a 2.5 kJ, 1 TW laser, and magnetically imploded by a 19 MA, 100 ns rise time current on the Z facility. Despite a predicted peak implosion velocity of only 70 km = s, the fuel reaches a stagnation temperature of approximately 3 keV, with T(e) ≈ T(i), and produces up to 2 x 10(12) thermonuclear deuterium-deuterium neutrons. X-ray emission indicates a hot fuel region with full width at half maximum ranging from 60 to 120 µm over a 6 mm height and lasting approximately 2 ns. Greater than 10(10) secondary deuterium-tritium neutrons were observed, indicating significant fuel magnetization given that the estimated radial areal density of the plasma is only 2 mg = cm(2).

16.
Phys Rev Lett ; 113(15): 155004, 2014 Oct 10.
Artigo em Inglês | MEDLINE | ID: mdl-25375715

RESUMO

Magnetizing the fuel in inertial confinement fusion relaxes ignition requirements by reducing thermal conductivity and changing the physics of burn product confinement. Diagnosing the level of fuel magnetization during burn is critical to understanding target performance in magneto-inertial fusion (MIF) implosions. In pure deuterium fusion plasma, 1.01 MeV tritons are emitted during deuterium-deuterium fusion and can undergo secondary deuterium-tritium reactions before exiting the fuel. Increasing the fuel magnetization elongates the path lengths through the fuel of some of the tritons, enhancing their probability of reaction. Based on this feature, a method to diagnose fuel magnetization using the ratio of overall deuterium-tritium to deuterium-deuterium neutron yields is developed. Analysis of anisotropies in the secondary neutron energy spectra further constrain the measurement. Secondary reactions also are shown to provide an upper bound for the volumetric fuel-pusher mix in MIF. The analysis is applied to recent MIF experiments [M. R. Gomez et al., Phys. Rev. Lett. 113, 155003 (2014)] on the Z Pulsed Power Facility, indicating that significant magnetic confinement of charged burn products was achieved and suggesting a relatively low-mix environment. Both of these are essential features of future ignition-scale MIF designs.

17.
Rev Sci Instrum ; 85(4): 043507, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24784607

RESUMO

We present a general methodology to determine the diagnostic sensitivity that is directly applicable to neutron-activation diagnostics fielded on a wide variety of neutron-producing experiments, which include inertial-confinement fusion (ICF), dense plasma focus, and ion beam-driven concepts. This approach includes a combination of several effects: (1) non-isotropic neutron emission; (2) the 1/r(2) decrease in neutron fluence in the activation material; (3) the spatially distributed neutron scattering, attenuation, and energy losses due to the fielding environment and activation material itself; and (4) temporally varying neutron emission. As an example, we describe the copper-activation diagnostic used to measure secondary deuterium-tritium fusion-neutron yields on ICF experiments conducted on the pulsed-power Z Accelerator at Sandia National Laboratories. Using this methodology along with results from absolute calibrations and Monte Carlo simulations, we find that for the diagnostic configuration on Z, the diagnostic sensitivity is 0.037% ± 17% counts/neutron per cm(2) and is ∼ 40% less sensitive than it would be in an ideal geometry due to neutron attenuation, scattering, and energy-loss effects.

18.
Adv Med Sci ; 58(2): 274-81, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24101372

RESUMO

PURPOSE: Aspirin is an antiplatelet drug which is commonly used in secondary prevention in ischemic heart disease and cerebrovascular events, and in newly diagnosed myocardial infarction. The aim of the present study was to examine effect of aspirin on the level of selected sphingolipid intermediates in plasma, erythrocytes and platelets. MATERIAL AND METHOD: Forty two healthy volunteers participated in the study. They were divided into two groups. In one group aspirin was given orally, daily, for one week in a dose of 75 mg (n=25). The subjects from the second group received one 300 mg dose of the drug (n=17). In both groups the blood was taken 4h after the last dose of aspirin. The following sphingolipid intermediates were quantified using high-pressure liquid chromatography: sphinganine, sphingosine, sphingosine-1-phosphate (S1P), sphinganine-1-phosphate (SA1P) and ceramide. RESULTS: It was found that lower dose of aspirin increased the level of S1P and ceramide in erythrocytes (by 23 and 37%, respectively) having no effect on plasma and platelet sphingolipid levels. Higher dose of the drug reduced S1P and SA1P concentration in the plasma (by 16 and 10%, respectively). CONCLUSION: We conclude that aspirin interferes with sphingolipid metabolism in blood and that this effect depends on a dose of the drug. Since S1P is a potent cardioprotectant, the reduction in its plasma concentration after the loading dose of aspirin could be undesired side effect of the drug.


Assuntos
Anti-Inflamatórios não Esteroides/administração & dosagem , Aspirina/administração & dosagem , Inibidores da Agregação Plaquetária/administração & dosagem , Esfingolipídeos/sangue , Anti-Inflamatórios não Esteroides/sangue , Anti-Inflamatórios não Esteroides/farmacologia , Aspirina/sangue , Aspirina/farmacologia , Plaquetas/efeitos dos fármacos , Plaquetas/metabolismo , Ceramidas/sangue , Ceramidas/metabolismo , Relação Dose-Resposta a Droga , Eritrócitos/efeitos dos fármacos , Eritrócitos/metabolismo , Feminino , Voluntários Saudáveis , Hemoglobinas/metabolismo , Humanos , Lisofosfolipídeos/sangue , Lisofosfolipídeos/metabolismo , Masculino , Inibidores da Agregação Plaquetária/sangue , Inibidores da Agregação Plaquetária/farmacologia , Contagem de Plaquetas , Esfingolipídeos/metabolismo , Esfingosina/análogos & derivados , Esfingosina/sangue , Esfingosina/metabolismo , Adulto Jovem
19.
Adv Med Sci ; 58(1): 96-103, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23625281

RESUMO

PURPOSE: Endometrial cancer (EC) is one of the most common malignancies of the female genital tract, but the etiology, especially its metabolism is still investigated. The aim of this study was to evaluate the presence and relative expression of Estrogen Receptors (α, ß), Cyclooxygenase-2 and Aromatase in both endometrial cancer and normal mucosa. MATERIAL/METHODS: Two groups of women were selected for the study: 1) patients with endometrioid endometrial cancer (FIGO I; G1 - G3) (n=35) and 2) subjects with normal endometrial tissue (control group, n=29). The expression of Estrogen Receptors (ERα, ß), Cyclooxygenase-2 (COX-2), Aromatase were estimated by Western blot analysis. Furthermore, the associations between FIGO classification (stage: Ia, Ib), tumor grade (G) and expression of ERα, ß, COX-2, aromatase proteins were evaluated. Overall and disease-free survival curves were generated according to the Kaplan-Meier method. Median follow-up time of the patients examined in this study was 39 months. RESULTS: The relative expression of each examined protein was markedly higher in the endometrial cancer tissue as compared to the healthy endometrium. The trends towards greater expression along with a tumor progression was noticed (FIGO stage: Ia vs. Ib). Analysis of endometrial cancer risk factors and their influence on survival curves showed only an inverse significant correlations between obesity (BMI: 36.2; n=21) and disease-free survival in EC group (p=0.00872), but there was no significant association between obesity and overall survival (p=0.358). CONCLUSIONS: Endometrioid endometrial cancer shows relatively higher expression of either ER, COX-2 and aromatase comparing to healthy mucosa, suggesting their involvement in tumor development and progression.


Assuntos
Aromatase/metabolismo , Ciclo-Oxigenase 2/metabolismo , Neoplasias do Endométrio/metabolismo , Endométrio/metabolismo , Receptor alfa de Estrogênio/metabolismo , Receptor beta de Estrogênio/metabolismo , Adulto , Idoso , Estudos de Casos e Controles , Progressão da Doença , Intervalo Livre de Doença , Feminino , Regulação Neoplásica da Expressão Gênica , Humanos , Pessoa de Meia-Idade , Mucosa/metabolismo , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
20.
Waste Manag ; 33(1): 43-51, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23017646

RESUMO

Mineralogical and chemical investigations of deposits from superheaters and economisers from a MSWI plant in Mannheim, Germany, lead to a classification system which provides information about the most critical parameters leading to fouling and corrosion. With the help of this classification system parameters like the geometry of boilers and the waste input can be changed in order to prolong run times between revisions and enhance energy efficiency of MSWI plants.


Assuntos
Incineração/instrumentação , Minerais/análise , Resíduos/análise , Temperatura , Resíduos/classificação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...