Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Eur J Radiol Open ; 11: 100538, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38028186

RESUMO

Purpose: To investigate if clinical non-contrast chest CT studies obtained with PCD CT using much lower radiation exposure can achieve the same image quality as with the currently established EID protocol. Materials/methods: A total of seventy-one patients were identified who had a non-contrast chest computed tomography (CT) done on PCD CT and EID CT scanners within a 4-month interval. Five fellowship trained chest radiologists, blinded to the scanner details were asked to review the cases side-by-side and record their preference for images from either the photon-counting-detector (PCD) CT or the energy-integrating detector (EID) CT scanner. Results: The median CTDIvol for PCD-CT system was 4.710 mGy and EID system was 7.80 mGy (p < 0.001). The median DLP with the PCD-CT was 182.0 mGy.cm and EID system was 262.60 mGy.cm (p < 0.001). The contrast to noise ratio (CNR) was superior on the PCD-CT system 59.2 compared to the EID-CT 53.3; (p < 0.001). Kappa-statistic showed that there was poor agreement between the readers over the image quality from the PCD and EID scanners (κ = 0.19; 95 % CI: 0.12 - 0.27; p < 0.001). Chi-square analysis revealed that 3 out of 5 readers showed a significant preference for images from the PCDCT (p ≤ 0.012). There was no significant difference in the preferences of two readers between EID-CT and PCD-CT images. Conclusion: The first clinical PCD-CT system allows a significant reduction in radiation exposure while maintaining image quality and image noise using a standardized non-contrast chest CT protocol.

2.
Sci Rep ; 13(1): 14895, 2023 09 09.
Artigo em Inglês | MEDLINE | ID: mdl-37689744

RESUMO

We evaluate stability of spectral results at different heart rates, acquisition modes, and cardiac phases in first-generation clinical dual-source photon-counting CT (PCCT). A cardiac motion simulator with a coronary stenosis mimicking a 50% eccentric calcium plaque was scanned at five different heart rates (0, 60-100 bpm) with the three available cardiac scan modes (high pitch prospectively ECG-triggered spiral, prospectively ECG-triggered axial, retrospectively ECG-gated spiral). Subsequently, full width half max (FWHM) of the stenosis, Dice score (DSC) for the stenosed region, and eccentricity of the non-stenosed region were calculated for virtual monoenergetic images (VMI) at 50, 70, and 150 keV and iodine density maps at both diastole and systole. FWHM averaged differences of - 0.20, - 0.28, and - 0.15 mm relative to static FWHM at VMI 150 keV across acquisition parameters for high pitch prospectively ECG-triggered spiral, prospectively ECG-triggered axial, and retrospectively ECG-gated spiral scans, respectively. Additionally, there was no effect of heart rate and acquisition mode on FWHM at diastole (p-values < 0.001). DSC demonstrated similarity among parameters with standard deviations of 0.08, 0.09, 0.11, and 0.08 for VMI 50, 70, and 150 keV, and iodine density maps, respectively, with insignificant differences at diastole (p-values < 0.01). Similarly, eccentricity illustrated small differences across heart rate and acquisition mode for each spectral result. Consistency of spectral results at different heart rates and acquisition modes for different cardiac phase demonstrates the added benefit of spectral results from PCCT to dual-source CT to further increase confidence in quantification and advance cardiovascular diagnostics.


Assuntos
Estenose Coronária , Iodo , Humanos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Coração/diagnóstico por imagem , Constrição Patológica
3.
Pacing Clin Electrophysiol ; 34(10): e94-7, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20565692

RESUMO

We report a patient with ventricular and atrial tachycardias reproducibly induced during exercise testing. Atrial tachycardia, but no sustained ventricular tachycardia, was induced during electrophysiological study. Catecholaminergic polymorphic ventricular tachycardia was considered because of normal echocardiogram, family history of sudden death, and polymorphic appearance of some of the nonsustained ventricular tachycardia episodes. However, most episodes of ventricular tachycardia were monomorphic. Cardiac magnetic resonance diagnosed isolated left ventricular noncompaction.


Assuntos
Teste de Esforço , Miocárdio Ventricular não Compactado Isolado/diagnóstico , Volume Sistólico , Diagnóstico Diferencial , Feminino , Humanos , Miocárdio Ventricular não Compactado Isolado/diagnóstico por imagem , Imageamento por Ressonância Magnética , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Taquicardia/diagnóstico , Taquicardia/diagnóstico por imagem , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/diagnóstico por imagem , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...