Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Surg Case Rep ; 2024(3): rjae187, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38549722

RESUMO

We report the case of a 76-year-old woman with an incomplete atrioventricular septal defect and severe congestive heart failure who underwent surgical repair. Surgical intervention involved mitral valve repair and patch closure of the ostium primum defect, resulting in a favorable postoperative course. Successful outcomes support surgery as a reasonable treatment option owing to its significant improvement in postoperative quality of life, even in elderly patients with left atrioventricular valve degeneration.

2.
Artigo em Inglês | MEDLINE | ID: mdl-37027581

RESUMO

This work introduces a perspective-corrected video see-through mixed-reality head-mounted display with edge-preserving occlusion and low-latency capabilities. To realize the consistent spatial and temporal composition of a captured real world containing virtual objects, we perform three essential tasks: 1) to reconstruct captured images so as to match the user's view; 2) to occlude virtual objects with nearer real objects, to provide users with correct depth cues; and 3) to reproject the virtual and captured scenes to be matched and to keep up with users' head motions. Captured image reconstruction and occlusion-mask generation require dense and accurate depth maps. However, estimating these maps is computationally difficult, which results in longer latencies. To obtain an acceptable balance between spatial consistency and low latency, we rapidly generated depth maps by focusing on edge smoothness and disocclusion (instead of fully accurate maps), to shorten the processing time. Our algorithm refines edges via a hybrid method involving infrared masks and color-guided filters, and it fills disocclusions using temporally cached depth maps. Our system combines these algorithms in a two-phase temporal warping architecture based upon synchronized camera pairs and displays. The first phase of warping is to reduce registration errors between the virtual and captured scenes. The second is to present virtual and captured scenes that correspond with the user's head motion. We implemented these methods on our wearable prototype and performed end-to-end measurements of its accuracy and latency. We achieved an acceptable latency due to head motion (less than 4 ms) and spatial accuracy (less than 0.1° in size and less than 0.3° in position) in our test environment. We anticipate that this work will help improve the realism of mixed reality systems.

3.
J Surg Case Rep ; 2021(5): rjab170, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-34025971

RESUMO

Pulmonary valve stenosis and regurgitation can occur in the distant stages after intracardiac repair of tetralogy of Fallot (TOF). Aortic regurgitation (AR) can also occur, although it is rare in postoperative patients. However, there are few reports of simultaneous replacement of the pulmonary and aortic valves in young patients after intracardiac repair of TOF, and there are no clear guidelines for selecting a valve prosthesis in such patients. We report a case of severe pulmonary valve stenosis and regurgitation with severe AR 38 years after the TOF operation, in which urgent double valve replacement and right ventricular outflow tract patching were performed with a mechanical valve in the aortic valve position and a bioprosthetic valve in the pulmonary valve position, with a successful outcome.

4.
Clin Case Rep ; 7(10): 1880-1884, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31624601

RESUMO

While isolated iliac artery aneurysm is rare, its rupture can lead to complete circulatory collapse and possibly death. Herein, we report a case of rupture of a large isolated aneurysm of the right common iliac artery that led to circulatory collapse and rapid endovascular repair saved the patient's life.

5.
J Surg Case Rep ; 2019(7): rjz211, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31308930

RESUMO

A Kommerell's diverticulum is a rare congenital aortic arch anomaly associated with a high rate of aortic rupture or dissection. Therefore, surgical or endovascular repair should be considered early. A 64-year-old man was incidentally found to have an aortic arch anomaly, Kommerell's diverticulum, with a right aberrant subclavian artery and distal arch aneurysm. Hybrid total arch replacement with bilateral extra-anatomical axillary artery bypass and frozen elephant trunk technique was performed. This particular surgical approach would be a treatment option for any type of Kommerell's diverticulum.

6.
J Surg Case Rep ; 2019(3): rjz056, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30886694

RESUMO

Minimally invasive cardiac surgery has recently become widespread because it has few disadvantages. However, lung hernia has been reported as a rare complication of minimally invasive cardiac surgery (MICS), and normally requiring additional surgical procedures. We describe herein a case of manual repositioning of lung hernia after MICS.

7.
J Surg Case Rep ; 2018(10): rjy285, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30386548

RESUMO

Since its introduction in Japan in 1980, the extracorporeal left ventricular assist device has been used as a bridge to the recovery of cardiac function or to heart transplantation by many institutions. In this case report, we describe a 23-year-old female with peripartum cardiomyopathy. She had a persistently low cardiac index despite intensive care with intravenous inotropes, intra-aortic balloon pumping and extracorporeal membrane oxygenation; thus, we implanted an extracorporeal left ventricular assist device. Thereafter, her cardiac function gradually improved; the device was removed 2 months after the implantation. She currently has good heart function.

8.
Ann Vasc Dis ; 11(3): 369-372, 2018 Sep 25.
Artigo em Inglês | MEDLINE | ID: mdl-30402193

RESUMO

A 79-year-old man with a heavy smoking history presented with threatened lower limbs due to acute exacerbation of peripheral artery disease (PAD). He underwent emergent distal bypass surgery for the right leg and external iliac stenting for the left leg. Fatal coronary artery spasm (CAS) with ST segment changes on electrocardiography was observed 28 h after the procedures, resulting in cardiac arrest. Coronary angiography showed widespread CAS with improvement after intra-arterial nitroglycerin infusion. We should keep in mind that CAS may occur more frequently than expected in PAD patients, especially those who have not stopped smoking prior to revascularization.

9.
J Surg Case Rep ; 2018(7): rjy172, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30057743

RESUMO

We report a case of total arch replacement in a patient who suffered repeated cerebral infarctions due to unstable plaque simultaneously in the innominate and left subclavian arteries.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...