Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Biosens Bioelectron ; 240: 115605, 2023 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-37669586

RESUMO

Diabetes is known to cause a variety of complications, having a high correlation with Alzheimer's disease. Electrophysiological recording using a microscale needle electrode is a promising technology for the study, however, diabetic brain tissue is more difficult to record neuronal activities than normal tissue due to these complications including the development of cerebrovascular disease. Here we show an electrophysiological methodology for diabetic db/db mice (+Leprdb/+Leprdb) using a 4-µm-tip diameter needle-electrode device. The needle electrode minimized the tissue injury when compared to a typical larger metal electrode, as confirmed by bleeding during penetration. The proposed electrode device showed both acute and chronic in vivo recording capabilities for diabetic mice while reducing the glial cells' responses. Because of these device characteristics, the 4-µm-tip diameter needle-electrode will allow electrophysiological studies on diabetes models of not only mice, as proven in this study, but also other animals.


Assuntos
Doença de Alzheimer , Técnicas Biossensoriais , Diabetes Mellitus Experimental , Animais , Camundongos , Neuroglia , Modelos Animais de Doenças , Eletrodos
2.
eNeuro ; 10(9)2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37696665

RESUMO

In neurophysiology, achieving precise correlation between physiological responses and anatomic structures is a significant challenge. Therefore, the accuracy of the electrode marking method is crucial. In this study, we describe a tungsten-deposition method, in which tungsten oxide is generated by applying biphasic current pulses to conventional tungsten electrodes. The electrical current used was 40-50 µA, which is similar to that used in electrical microstimulation experiments. The size of the markings ranged from 10 to 100 µm, corresponding to the size of the electrode tip, which is smaller than that of existing marking methods. Despite the small size of the markings, detection is easy as the marking appears in bright red under dark-field observation after Nissl staining. This marking technique resulted in low tissue damage and was maintained in vivo for at least two years. The feasibility of this method was tested in mouse and macaque brains.


Assuntos
Encéfalo , Tungstênio , Animais , Camundongos , Microeletrodos , Macaca , Neurofisiologia
3.
ACS Nano ; 16(7): 10692-10700, 2022 07 26.
Artigo em Inglês | MEDLINE | ID: mdl-35786946

RESUMO

Microscale needle-like electrode technologies offer in vivo extracellular recording with a high spatiotemporal resolution. Further miniaturization of needles to nanoscale minimizes tissue injuries; however, a reduced electrode area increases electrical impedance that degrades the quality of neuronal signal recording. We overcome this limitation by fabricating a 300 nm tip diameter and 200 µm long needle electrode where the amplitude gain with a high-impedance electrode (>15 MΩ, 1 kHz) was improved from 0.54 (-5.4 dB) to 0.89 (-1.0 dB) by stacking it on an amplifier module of source follower. The nanoelectrode provided the recording of both local field potential (<300 Hz) and action potential (>500 Hz) in the mouse cortex, in contrast to the electrode without the amplifier. These results suggest that microelectrodes can be further minimized by the proposed amplifier configuration for low-invasive recording and electrophysiological studies in submicron areas in tissues, such as dendrites and axons.


Assuntos
Amplificadores Eletrônicos , Neurônios , Animais , Camundongos , Potenciais de Ação/fisiologia , Eletrofisiologia/métodos , Microeletrodos , Neurônios/fisiologia
4.
Front Psychol ; 13: 766056, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35250710

RESUMO

Specular reflections and refractive distortions are complex image properties of solid transparent objects, but despite this complexity, we readily perceive the 3D shapes of these objects (e.g., glass and clear plastic). We have found in past work that relevant sources of scene complexity have differential effects on 3D shape perception, with specular reflections increasing perceived thickness, and refractive distortions decreasing perceived thickness. In an object with both elements, such as glass, the two optical properties may complement each other to support reliable perception of 3D shape. We investigated the relative dominance of specular reflection and refractive distortions in the perception of shape. Surprisingly, the ratio of specular reflection to refractive component was almost equal to that of ordinary glass and ice, which promote correct percepts of 3D shape. The results were also explained by the variance in local RMS contrast in stimulus images but may depend on overall luminance and contrast of the surrounding light field.

5.
Front Psychol ; 13: 818149, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35140670

RESUMO

Chromatic induction is a major contextual effect of color appearance. Patterned backgrounds are known to induce strong chromatic induction effects. However, it has not been clarified whether the spatial extent of the chromatic surrounding induces a chromatic contrast or assimilation effects. In this study, we examined the influence of the width of a center line and its flanking white contour on the color appearance when the line was surrounded by chromatic backgrounds. A strong color shift was observed when the center line was flanked by white contours with the L/M- and S-cone chromatic backgrounds. There was a difference between the optimal widths of the center line and the contour for the shift in color appearance for the L/M-cone chromaticity (0.9 and 1.1-1.7 min, respectively) and the S-cone chromaticity (8.2-17.5 and 0.9-2.5 min, respectively). The optimal width of the center line for the L/M-cone was finer than the resolution-limit width of the chromatic contrast sensitivity and coarser than that of the luminance contrast sensitivity. Thus, the color appearance of the center line could be obtained by integrating broad chromatic information and fine luminance details. Due to blurring and chromatic aberrations, the simulated artifact was large for the darker center line and S-cone background, thus suggesting that the artifact could explain the luminance dependency of the induction along the S-cone chromaticity. Moreover, the findings of this study reveal that the dominant factor of the color shift is neural instead of optical.

6.
Lab Chip ; 22(4): 747-756, 2022 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-35044407

RESUMO

Microelectrode technology is essential in electrophysiology and has made contributions to neuroscience as well as to medical applications. However, it is necessary to minimize tissue damage associated with needle-like electrode on the brain tissue and the implantation surgery, which makes stable chronic recording impossible. Here, we report on an approach for using a 5 µm-diameter needle electrode, which enables the following of tissue motions, via a surgical method. The electrode is placed on the brain tissue of a mouse with a dissolvable material, reducing the physical stress to the tissue; this is followed by the implantation of the electrode device in the brain without fixing it to the cranium, achieving a floating electrode architecture on the tissue. The electrode shows stable recording with no significant degradation of the signal-to-noise ratios for 6 months, and minimized tissue damage is confirmed compared to that when using a cranium-fixed electrode with the same needle geometry.


Assuntos
Encéfalo , Neurônios , Animais , Encéfalo/fisiologia , Eletrodos Implantados , Camundongos , Microeletrodos , Neurônios/fisiologia , Razão Sinal-Ruído
7.
Proc Natl Acad Sci U S A ; 118(16)2021 04 20.
Artigo em Inglês | MEDLINE | ID: mdl-33846241

RESUMO

Microscale needle-electrode devices offer neuronal signal recording capability in brain tissue; however, using needles of smaller geometry to minimize tissue damage causes degradation of electrical properties, including high electrical impedance and low signal-to-noise ratio (SNR) recording. We overcome these limitations using a device assembly technique that uses a single needle-topped amplifier package, called STACK, within a device of ∼1 × 1 mm2 Based on silicon (Si) growth technology, a <3-µm-tip-diameter, 400-µm-length needle electrode was fabricated on a Si block as the module. The high electrical impedance characteristics of the needle electrode were improved by stacking it on the other module of the amplifier. The STACK device exhibited a voltage gain of >0.98 (-0.175 dB), enabling recording of the local field potential and action potentials from the mouse brain in vivo with an improved SNR of 6.2. Additionally, the device allowed us to use a Bluetooth module to demonstrate wireless recording of these neuronal signals; the chronic experiment was also conducted using STACK-implanted mice.


Assuntos
Eletroencefalografia/instrumentação , Eletrofisiologia/instrumentação , Eletrofisiologia/métodos , Potenciais de Ação/fisiologia , Animais , Encéfalo/fisiologia , Impedância Elétrica , Eletrodos Implantados/efeitos adversos , Eletroencefalografia/métodos , Desenho de Equipamento , Masculino , Camundongos , Microeletrodos/efeitos adversos , Neurônios/fisiologia , Razão Sinal-Ruído
8.
Sci Rep ; 10(1): 20136, 2020 Nov 18.
Artigo em Inglês | MEDLINE | ID: mdl-33208897

RESUMO

Simultaneous color contrast and assimilation are mutually opposing effects on color appearance, and their magnitude depends on spatial context. The Monnier-Shevell illusion induces a large color shift by a synergy of simultaneous assimilation and contrast using the alternating color of proximal and distant surrounds. The illusion induces a prominent effect along the blue-yellow color axis, but a subtle effect along the orthogonal color axis. In this study, we report an illusion generated by an extremely thin gray line on a cyan background that appears reddish when the line is flanked by thin white contours. We quantified the color appearance of the gray line in a color matching experiment and found that the color shift of the gray line with white contours induced large color shifts. It is also known that luminance contrast between a center and its surrounds affects the magnitude of simultaneous color contrast. However, our color contrast effects were larger for a dark line rather than for a pale line. In contrast, the perceived color shift of the line without the contours increased as the luminance of the gray line increased, supporting the known effect of Kirschmann's third law. These results indicate that Kirschmann's third law fails to explain the perceived color shift of our illusion, even after accounting for optical factors like aberrations. Observed color shifts could be explained by an augmented synergy theory based on intensity space, rather than chromaticity.

9.
Iperception ; 11(6): 2041669520982317, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33489077

RESUMO

Perceiving the shape of three-dimensional objects is essential for interacting with them in daily life. If objects are constructed from different materials, can the human visual system accurately estimate their three-dimensional shape? We varied the thickness, motion, opacity, and specularity of globally convex objects rendered in a photorealistic environment. These objects were presented under either dynamic or static viewing condition. Observers rated the overall convexity of these objects along the depth axis. Our results show that observers perceived solid transparent objects as flatter than the same objects rendered with opaque reflectance properties. Regional variation in local root-mean-square image contrast was shown to provide information that is predictive of perceived surface convexity.

10.
Adv Healthc Mater ; 8(23): e1900939, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31697038

RESUMO

Electronic devices used to record biological signals are important in neuroscience, brain-machine interfaces, and medical applications. Placing electronic devices below the skin surface and recording the muscle offers accurate and robust electromyography (EMG) recordings. The device stretchability and flexibility must be similar to the tissues to achieve an intimate integration of the electronic device with the biological tissues. However, conventional elastomer-based EMG electrodes have a Young's modulus that is ≈20 times higher than that of muscle. In addition, these stretchable devices also have an issue of displacement on the tissue surface, thereby causing some challenges during accurate and robust EMG signal recordings. In general, devices with kirigami design solve the issue of the high Young's modulus of conventional EMG devices. In this study, donut-shaped kirigami bioprobes are proposed to reduce the device displacement on the muscle surface. The fabricated devices are tested on an expanding balloon and they show no significant device (microelectrode) displacement. As the package, the fabricated device is embedded in a dissolvable material-based scaffold for easy-to-use stretchable kirigami device in an animal experiment. Finally, the EMG signal recording capability and stability using the fabricated kirigami device is confirmed in in vivo experiments without significant device displacements.


Assuntos
Eletrodos , Eletrônica , Dispositivos Eletrônicos Vestíveis , Módulo de Elasticidade , Eletromiografia , Microeletrodos
11.
Iperception ; 10(2): 2041669519846136, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31066374

RESUMO

Protanomalous females with X chromosome-linked color vision deficiency exhibit mild abnormalities, whereas dichromats show a distinct deficiency in discriminating certain color pairs. Dichromats have an advantage in detecting a textured target when it is camouflaged by red-green colors, owing to their insensitivity to these colors. However, it is not certain whether protanomalous females possess a similar advantage in breaking camouflage. Here, we introduce an animal model of dichromatic macaque monkeys and protanomalous females. We examined whether protanomalous females have the same advantage in breaking color camouflage as shown by dichromatic macaques. We also tested whether they could discriminate a certain color pair that trichromats could, where the dichromats are confused. Our experiments show that protanomalous macaques can break color camouflage, similar to dichromats, and can discriminate colors similarly to trichromats. Protanomalous females are thus thought to have the combined ecological advantages of being both trichromats and dichromats.

12.
Adv Healthc Mater ; 8(5): e1801081, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30644660

RESUMO

Microelectrode devices, which enable the detection of neuronal signals in brain tissues, have made significant contributions in the field of neuroscience and the brain-machine interfaces. To further develop such microelectrode devices, the following requirements must be met: i) a fine needle's diameter (<30 µm) to reduce damage to tissues; ii) a long needle (e.g., ≈1 mm for rodents and ≈2 mm for macaques); and iii) multiple electrodes to achieve high spatial recording (<100 µm in pitch). In order to meet these requirements, this study herein reports an assembly technique for high-aspect-ratio microneedles, which employs a magnet. The assembly is demonstrated, in which nickel wires of length 750 µm and diameter 25 µm are produced on a silicon substrate. The impedance magnitude of the assembled needle-like electrode measured at 1 kHz is 5.6 kΩ, exhibiting output and input signal amplitudes of 96.7% at 1 kHz. To confirm the recording capability of the fabricated device, neuronal signal recordings are performed using mouse cerebra in vivo. The packaged single microneedle electrode penetrates the barrel field in the primary somatosensory cortex of the mouse and enables the detection of evoked neuronal activity of both local field potentials and action potentials.


Assuntos
Neurônios/fisiologia , Potenciais de Ação/fisiologia , Animais , Encéfalo/fisiologia , Impedância Elétrica , Eletrodos Implantados , Eletroencefalografia/métodos , Magnetismo/métodos , Camundongos , Microeletrodos , Agulhas
13.
J Biomed Opt ; 23(2): 1-4, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29453847

RESUMO

Bundled fiber optics allow in vivo imaging at deep sites in a body. The intrinsic optical contrast detects detailed structures in blood vessels and organs. We developed a bundled-fiber-coupled endomicroscope, enabling stereoscopic three-dimensional (3-D) reflectance imaging with a multipositional illumination scheme. Two illumination sites were attached to obtain reflectance images with left and right illumination. Depth was estimated by the horizontal disparity between the two images under alternative illuminations and was calibrated by the targets with known depths. This depth reconstruction was applied to an animal model to obtain the 3-D structure of blood vessels of the cerebral cortex (Cereb cortex) and preputial gland (Pre gla). The 3-D endomicroscope could be instrumental to microlevel reflectance imaging, improving the precision in subjective depth perception, spatial orientation, and identification of anatomical structures.


Assuntos
Endoscopia/métodos , Imageamento Tridimensional/métodos , Microscopia de Fluorescência/métodos , Animais , Córtex Cerebral/irrigação sanguínea , Córtex Cerebral/diagnóstico por imagem , Endoscopia/instrumentação , Desenho de Equipamento , Tecnologia de Fibra Óptica , Camundongos , Microscopia de Fluorescência/instrumentação
14.
Adv Healthc Mater ; 7(3)2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29218800

RESUMO

An ultrastretchable film device is developed that can follow the shape of spherical and large deformable biological samples such as heart and brain tissues. Although the film is composed of biocompatible parylene for the device substrate and metal layers of platinum (Pt)/titanium (Ti), which are unstretchable materials, the film shows a high stretchability by patterning slits as a "Kirigami" design. A Pt/Ti-microelectrode array embedded in 11 µm thick parylene film with 5 × 91 slits exhibits a film strain of ≈250% at 9 mN strain-force (0.08 MPa in stress) with a Young's modulus of 23 kPa, while the 3 × 91-slit film shows a Young's modulus of 3.6 kPa. The maximum strains of these devices are ≈470% and ≈840%, respectively. It is demonstrated that the Kirigami-based microelectrode device can simultaneously record in vivo electrocorticogram signals from the visual and barrel cortices of a mouse by stretching the film and tuning the electrode gap. Moreover, wrapping the Kirigami device around a beating mouse's heart, which shows large and rapid changes in the volume and the surface area, can record the in vivo epicardial electrocardiogram signals. Such a small Young's modulus for a stretchable device reduces the device's strain-force, minimizing the device-induced stress to soft biological tissues.


Assuntos
Materiais Biocompatíveis/química , Módulo de Elasticidade , Teste de Materiais , Microeletrodos , Titânio/química
15.
Elife ; 62017 07 24.
Artigo em Inglês | MEDLINE | ID: mdl-28737487

RESUMO

The capacity for flexible sensory-action association in animals has been related to context-dependent attractor dynamics outside the sensory cortices. Here, we report a line of evidence that flexibly modulated attractor dynamics during task switching are already present in the higher visual cortex in macaque monkeys. With a nonlinear decoding approach, we can extract the particular aspect of the neural population response that reflects the task-induced emergence of bistable attractor dynamics in a neural population, which could be obscured by standard unsupervised dimensionality reductions such as PCA. The dynamical modulation selectively increases the information relevant to task demands, indicating that such modulation is beneficial for perceptual decisions. A computational model that features nonlinear recurrent interaction among neurons with a task-dependent background input replicates the key properties observed in the experimental data. These results suggest that the context-dependent attractor dynamics involving the sensory cortex can underlie flexible perceptual abilities.


Assuntos
Percepção de Cores/fisiologia , Modelos Neurológicos , Neurônios/fisiologia , Análise e Desempenho de Tarefas , Córtex Visual/fisiologia , Percepção Visual/fisiologia , Animais , Comportamento Animal , Simulação por Computador , Feminino , Macaca , Neurônios/citologia , Dinâmica não Linear , Estimulação Luminosa
16.
Biomed Opt Express ; 7(3): 963-78, 2016 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-27231601

RESUMO

Bioluminescence imaging (BLI) is used in biomedical research to monitor biological processes within living organisms. Recently, fiber bundles with high transmittance and density have been developed to detect low light with high resolution. Therefore, we have developed a bundled-fiber-coupled microscope with a highly sensitive cooled-CCD camera that enables the BLI of organs within the mouse body. This is the first report of in vivo BLI of the brain and multiple organs in luciferase-reporter mice using bundled-fiber optics. With reflectance imaging, the structures of blood vessels and organs can be seen clearly with light illumination, and it allowed identification of the structural details of bioluminescence images. This technique can also be applied to clinical diagnostics in a low invasive manner.

17.
Sci Rep ; 6: 22536, 2016 Mar 03.
Artigo em Inglês | MEDLINE | ID: mdl-26935275

RESUMO

Categorical perception is a ubiquitous function in sensory information processing, and is reported to have important influences on the recognition of presented and/or memorized stimuli. However, such complex interactions among categorical perception and other aspects of sensory processing have not been explained well in a unified manner. Here, we propose a recurrent neural network model to process categorical information of stimuli, which approximately realizes a hierarchical Bayesian estimation on stimuli. The model accounts for a wide variety of neurophysiological and cognitive phenomena in a consistent framework. In particular, the reported complexity of categorical effects, including (i) task-dependent modulation of neural response, (ii) clustering of neural population representation, (iii) temporal evolution of perceptual color memory, and (iv) a non-uniform discrimination threshold, are explained as different aspects of a single model. Moreover, we directly examine key model behaviors in the monkey visual cortex by analyzing neural population dynamics during categorization and discrimination of color stimuli. We find that the categorical task causes temporally-evolving biases in the neuronal population representations toward the focal colors, which supports the proposed model. These results suggest that categorical perception can be achieved by recurrent neural dynamics that approximates optimal probabilistic inference in the changing environment.


Assuntos
Modelos Neurológicos , Rede Nervosa/fisiologia , Córtex Visual/fisiologia , Percepção Visual/fisiologia , Animais , Humanos , Macaca mulatta
18.
J Vis ; 16(1): 10, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26790842

RESUMO

The glare illusion refers to brightness enhancement and the perception of a self-luminous appearance that occurs when a central region is surrounded by a luminance gradient. The center region appears to be a light source, with its light dispersing into the surrounding region. If the luminous edge is critical for generating the illusion, modulating the perceived luminance of the image, and switching its appearance from luminous to nonluminous, would have a strong impact on lightness and brightness estimation. Here, we quantified the illusion in two ways, by assessing brightness enhancement and examining whether the center region appeared luminous. Thus, we could determine whether the two effects occurred jointly or independently. We examined a wide luminance range of center regions, from 0 to 200% relative to background. Brightness enhancement in the illusion was observed for a wide range of luminances (20% to 200% relative to background), while a luminous-white appearance was observed when the center region luminance was 145% of the background. These results exclude the possibility that brightness enhancement occurs because the stimuli appear self-luminous. We suggest that restoring the original image intensity precedes the perceptual process of lightness estimation.


Assuntos
Ofuscação , Ilusões/fisiologia , Luz , Percepção Visual/fisiologia , Adulto , Feminino , Humanos , Masculino , Visão Ocular , Adulto Jovem
19.
Vision Res ; 115(Pt B): 259-70, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25536464

RESUMO

Humans can visually recognize material categories of objects, such as glass, stone, and plastic, easily. However, little is known about the kinds of surface quality features that contribute to such material class recognition. In this paper, we examine the relationship between perceptual surface features and material category discrimination performance for pictures of materials, focusing on temporal aspects, including reaction time and effects of stimulus duration. The stimuli were pictures of objects with an identical shape but made of different materials that could be categorized into seven classes (glass, plastic, metal, stone, wood, leather, and fabric). In a pre-experiment, observers rated the pictures on nine surface features, including visual (e.g., glossiness and transparency) and non-visual features (e.g., heaviness and warmness), on a 7-point scale. In the main experiments, observers judged whether two simultaneously presented pictures were classified as the same or different material category. Reaction times and effects of stimulus duration were measured. The results showed that visual feature ratings were correlated with material discrimination performance for short reaction times or short stimulus durations, while non-visual feature ratings were correlated only with performance for long reaction times or long stimulus durations. These results suggest that the mechanisms underlying visual and non-visual feature processing may differ in terms of processing time, although the cause is unclear. Visual surface features may mainly contribute to material recognition in daily life, while non-visual features may contribute only weakly, if at all.


Assuntos
Percepção de Forma/fisiologia , Adulto , Discriminação Psicológica , Feminino , Humanos , Masculino , Reconhecimento Visual de Modelos/fisiologia , Mascaramento Perceptivo , Estimulação Luminosa/métodos , Análise de Componente Principal , Psicofísica , Tempo de Reação , Propriedades de Superfície
20.
PLoS One ; 9(1): e86400, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24466074

RESUMO

Well-trained experts in pearl grading have been thought to evaluate pearls according to their glossiness, interference color, and shape. However, the characteristics of their evaluations are not fully understood. Using pearl grading experiments, we investigate the consistency of novice (i.e., without knowledge of pearl grading) and expert participants' pearl grading skill and then compare the novices' grading with that of experts; furthermore, we discuss the relationship between grading, interference color, and glossiness. We found that novices' grading was significantly less concordant with experts average grading than was experts' grading; more than half of novices graded pearls the opposite of how experts graded those same pearls. However, while experts graded pearls more consistently than novices did, novices' consistency was relatively high. We also found differences between the groups in regression analyses that used interference color and glossiness as explanatory variables and were conducted for each trial. Although the regression coefficient was significant in 60% of novices' trials, there were fewer significant trials for the experts (20%). This indicates that novices can also make use of these two factors, but that their usage is simpler than that of the experts. These results suggest that experts and novices share some values about pearls but that the evaluation method is elaborated for experts.


Assuntos
Prova Pericial , Joias/normas , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...