Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Phys Imaging Radiat Oncol ; 27: 100469, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37520639

RESUMO

Background and purpose: Metallic hip prostheses cause substantial artefacts in both computed tomography (CT) and magnetic resonance (MR) images used in radiotherapy treatment planning (RTP) for prostate cancer patients. The aim of this study was to evaluate the dose calculation accuracy of a synthetic CT (sCT) generation workflow and the improvement in implant visibility using metal artefact reduction sequences. Materials and methods: The study included 23 patients with prostate cancer who had hip prostheses, of which 10 patients had bilateral hip implants. An in-house protocol was applied to create sCT images for dose calculation comparison. The study compared prostheses volumes and resulting avoidance sectors against planning target volume (PTV) dose uniformity and organs at risk (OAR) sparing. Results: Median PTV dose difference between sCT and CT-based dose calculation among all patients was 0.1 % (-0.4 to 0.4%) (median(range)). Bladder and rectum differences (V50Gy) were 0.2 % (-0.3 to 1.1%) and 0.1 % (-0.9 to 0.5%). The median 3D local gamma pass rate for partial arc cases using a Dixon MR sequence was Γ20%2mm/2% = 99.9%. For the bilateral full arc cases, using a metal artefact reconstruction sequence, the pass rate was Γ20%2mm/2% = 99.0%. Conclusions: An in-house protocol for generating sCT images for dose calculation provided clinically feasible dose calculation accuracy for prostate cancer patients with hip implants. PTV median dose difference for uni- and bilateral patients with avoidance sectors remained <0.4%. The Outphase images enhanced implant visibility resulting in smaller avoidance sectors, better OAR sparing, and improved PTV uniformity.

2.
J Appl Clin Med Phys ; 23(7): e13611, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35413145

RESUMO

BACKGROUND AND PURPOSE: A novel method of retrospective liver modeling was developed based on four-dimensional magnetic resonance (4D-MR) images. The 4D-MR images will be utilized in generation of the subject-specific deformable liver model to be used in radiotherapy planning (RTP). The purpose of this study was to test and validate the developed 4D-magnetic resonance imaging (MRI) method with extensive phantom tests. We also aimed to build a motion model with image registration methods from liver simulating phantom images. MATERIALS AND METHODS: A deformable phantom was constructed by combining deformable tissue-equivalent material and a programmable 4D CIRS-platform. The phantom was imaged in 1.5 T MRI scanner with T2-weighted 4D SSFSE and T1-weighted Ax dual-echo Dixon SPGR sequences, and in computed tomography (CT). In addition, geometric distortion of the 4D sequence was measured with a GRADE phantom. The motion model was developed; the phases of the 4D-MRI were used as surrogate data, and displacement vector fields (DVF's) were used as a motion measurement. The motion model and the developed 4D-MRI method were evaluated and validated with extensive tests. RESULT: The 4D-MRI method enabled an accuracy of 2 mm using our deformable phantom compared to the 4D-CT. Results showed a mean accuracy of <2 mm between coordinates and DVF's measured from the 4D images. Three-dimensional geometric accuracy results with the GRADE phantom were: 0.9-mm mean and 2.5 mm maximum distortion within a 100 mm distance, and 2.2 mm mean, 5.2 mm maximum distortion within a 150 mm distance from the isocenter. CONCLUSIONS: The 4D-MRI method was validated with phantom tests as a necessary step before patient studies. The subject-specific motion model was generated and will be utilized in the generation of the deformable liver model of patients to be used in RTP.


Assuntos
Tomografia Computadorizada Quadridimensional , Imageamento por Ressonância Magnética , Humanos , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Movimento (Física) , Imagens de Fantasmas , Estudos Retrospectivos
3.
J Appl Clin Med Phys ; 21(12): 304-313, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33270997

RESUMO

Purpose of our research was to develop a four-dimensional (4D) magnetic resonance imaging (MRI) method of liver. Requirements of the method were to create a clinical procedure with acceptable imaging time and sufficient temporal and spatial accuracy. The method should produce useful planning image sets for stereotactic body radiation therapy delivery both during breath-hold and in free breathing. The purpose of the method was to improve the localization of liver metastasis. The method was validated with phantom tests. Imaging parameters were optimized to create a 4D dataset compressed to one respiratory cycle of the whole liver with clinically reasonable level of image contrast and artifacts. Five healthy volunteers were imaged with T2-weighted SSFSE research sequence. The respiratory surrogate signal was observed by the linear navigator interleaved with the anatomical liver images. The navigator was set on head-feet - direction on the superior surface of the liver to detect the edge of diaphragm. The navigator signal and 2D liver image data were retrospectively processed with a self-developed MATLAB algorithm. A deformable phantom for 4D imaging tests was constructed by combining deformable tissue-equivalent material and a commercial programmable motor unit of the 4D phantom with a clinically relevant range of deformation patterns. 4D Computed Tomography images were used as reference to validate the MRI protocol. The best compromise of reasonable accuracy and imaging time was found with 2D T2-weighted SSFSE imaging sequence using parameters: TR = 500-550 ms, images/slices = 20, slice thickness = 3 mm. Then, image processing with number of respiratory phases = 8 constructed accurate 4D images of liver. We have developed the 4D-MRI method visualizing liver motions three-dimensionally in one representative respiratory cycle. From phantom tests it was found that the spatial agreement to 4D-CT is within 2 mm that is considered sufficient for clinical applications.


Assuntos
Tomografia Computadorizada Quadridimensional , Imageamento por Ressonância Magnética , Humanos , Imageamento Tridimensional , Fígado/diagnóstico por imagem , Imagens de Fantasmas , Respiração , Estudos Retrospectivos
4.
Phys Med Biol ; 64(5): 055010, 2019 02 25.
Artigo em Inglês | MEDLINE | ID: mdl-30669135

RESUMO

The purpose of this study was to develop a method enabling synthetic computed tomography (sCT) generation of the whole abdomen using magnetic resonance imaging (MRI) scans of pediatric patients with abdominal tumors. The proposed method relies on an automatic atlas-based segmentation of bone and lungs followed by an MRI intensity to synthetic Hounsfield unit conversion. Separate conversion algorithms were used for bone, lungs and soft-tissue. Rigidly registered CT and T2-weighted MR images of 30 patients in treatment position and with the same field of view were used for the evaluation of the atlas and the conversion algorithms. The dose calculation accuracy of the generated sCTs was verified for volumetric modulated arc therapy (VMAT) and pencil beam scanning (PBS). VMAT and PBS plans were robust optimized on an internal target volume (ITV) against a patient set-up uncertainty of 5 mm. Average differences between CT and sCT dose calculations for the ITV V 95% were 0.5% (min 0.0%; max 5.0%) and 0.0% (min -0.1%; max 0.1%) for VMAT and PBS dose distributions, respectively. Average differences for the mean dose to the organs at risk were <0.2% (min -0.6%; max 1.2%) and <0.2% (min -2.0%; max 2.6%) for VMAT and PBS dose distributions, respectively. Results show that MRI-only photon and proton dose calculations are feasible for children with abdominal tumors.


Assuntos
Neoplasias Abdominais/diagnóstico por imagem , Neoplasias Abdominais/radioterapia , Imageamento por Ressonância Magnética , Fótons/uso terapêutico , Prótons , Doses de Radiação , Planejamento da Radioterapia Assistida por Computador/métodos , Algoritmos , Criança , Estudos de Viabilidade , Humanos , Masculino , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada
5.
Acta Oncol ; 57(7): 902-907, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29488426

RESUMO

BACKGROUND: Magnetic resonance imaging (MRI) is the most comprehensive imaging modality for radiation therapy (RT) target delineation of most soft tissue tumors including prostate cancer. We have earlier presented step by step the MRI-only based workflow for RT planning and image guidance for localized prostate cancer. In this study we present early clinical experiences of MRI-only based planning. MATERIAL AND METHODS: We have analyzed the technical planning workflow of the first 200 patients having received MRI-only planned radiation therapy for localized prostate cancer in Helsinki University Hospital Cancer center. Early prostate specific antigen (PSA) results were analyzed from n = 125 MRI-only patients (n = 25 RT only, n = 100 hormone treatment + RT) and were compared with the corresponding computed tomography (CT) planned patient group. RESULTS: Technically the MRI-only planning procedure was suitable for 92% of the patients, only 8% of the patients required supplemental CT imaging. Early PSA response in the MRI-only planned group showed similar treatment results compared with the CT planned group and with an equal toxicity level. CONCLUSION: Based on this retrospective study, MRI-only planning procedure is an effective and safe way to perform RT for localized prostate cancer. It is suitable for the majority of the patients.


Assuntos
Imageamento por Ressonância Magnética/métodos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Fluxo de Trabalho , Adulto , Idoso , Idoso de 80 Anos ou mais , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasias da Próstata/patologia , Dosagem Radioterapêutica , Radioterapia Conformacional/métodos , Estudos Retrospectivos , Resultado do Tratamento
6.
Radiother Oncol ; 125(3): 411-419, 2017 12.
Artigo em Inglês | MEDLINE | ID: mdl-29097012

RESUMO

BACKGROUND AND PURPOSE: Recent studies have shown that it is possible to conduct entire radiotherapy treatment planning (RTP) workflow using only MR images. This study aims to develop a generalized intensity-based method to generate synthetic CT (sCT) images from standard T2-weighted (T2w) MR images of the pelvis. MATERIALS AND METHODS: This study developed a generalized dual model HU conversion method to convert standard T2w MR image intensity values to synthetic HU values, separately inside and outside of atlas-segmented bone volume contour. The method was developed and evaluated with 20 and 35 prostate cancer patients, respectively. MR images with scanning sequences in clinical use were acquired with four different MR scanners of three vendors. RESULTS: For the generated synthetic CT (sCT) images of the 35 prostate patients, the mean (and maximal) HU differences in soft and bony tissue volumes were 16 ±â€¯6 HUs (34 HUs) and -46 ±â€¯56 HUs (181 HUs), respectively, against the true CT images. The average of the PTV mean dose difference in sCTs compared to those in true CTs was -0.6 ±â€¯0.4% (-1.3%). CONCLUSIONS: The study provides a generalized method for sCT creation from standard T2w images of the pelvis. The method produced clinically acceptable dose calculation results for all the included scanners and MR sequences.


Assuntos
Imageamento por Ressonância Magnética/métodos , Neoplasias da Próstata/radioterapia , Tomografia Computadorizada por Raios X/métodos , Humanos , Masculino , Neoplasias da Próstata/diagnóstico por imagem , Planejamento da Radioterapia Assistida por Computador/métodos
7.
Med Phys ; 43(8): 4634, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27487880

RESUMO

PURPOSE: Magnetic resonance imaging (MRI) is increasingly used for radiotherapy target delineation, image guidance, and treatment response monitoring. Recent studies have shown that an entire external x-ray radiotherapy treatment planning (RTP) workflow for brain tumor or prostate cancer patients based only on MRI reference images is feasible. This study aims to show that a MRI-only based RTP workflow is also feasible for proton beam therapy plans generated in MRI-based substitute computed tomography (sCT) images of the head and the pelvis. METHODS: The sCTs were constructed for ten prostate cancer and ten brain tumor patients primarily by transforming the intensity values of in-phase MR images to Hounsfield units (HUs) with a dual model HU conversion technique to enable heterogeneous tissue representation. HU conversion models for the pelvis were adopted from previous studies, further extended in this study also for head MRI by generating anatomical site-specific conversion models (a new training data set of ten other brain patients). This study also evaluated two other types of simplified sCT: dual bulk density (for bone and water) and homogeneous (water only). For every clinical case, intensity modulated proton therapy (IMPT) plans robustly optimized in standard planning CTs were calculated in sCT for evaluation, and vice versa. Overall dose agreement was evaluated using dose-volume histogram parameters and 3D gamma criteria. RESULTS: In heterogeneous sCTs, the mean absolute errors in HUs were 34 (soft tissues: 13, bones: 92) and 42 (soft tissues: 9, bones: 97) in the head and in the pelvis, respectively. The maximum absolute dose differences relative to CT in the brain tumor clinical target volume (CTV) were 1.4% for heterogeneous sCT, 1.8% for dual bulk sCT, and 8.9% for homogenous sCT. The corresponding maximum differences in the prostate CTV were 0.6%, 1.2%, and 3.6%, respectively. The percentages of dose points in the head and pelvis passing 1% and 1 mm gamma index criteria were over 91%, 85%, and 38% with heterogeneous, dual bulk, and homogeneous sCTs, respectively. There were no significant changes to gamma index pass rates for IMPT plans first optimized in CT and then calculated in heterogeneous sCT versus IMPT plans first optimized in heterogeneous sCT and then calculated on standard CT. CONCLUSIONS: This study demonstrates that proton therapy dose calculations on heterogeneous sCTs are in good agreement with plans generated with standard planning CT. An MRI-only based RTP workflow is feasible in IMPT for brain tumors and prostate cancers.


Assuntos
Neoplasias Encefálicas/radioterapia , Imageamento por Ressonância Magnética/métodos , Neoplasias da Próstata/radioterapia , Terapia com Prótons/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Osso e Ossos/diagnóstico por imagem , Neoplasias Encefálicas/diagnóstico por imagem , Estudos de Viabilidade , Cabeça/diagnóstico por imagem , Humanos , Masculino , Pelve/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico por imagem , Dosagem Radioterapêutica , Radioterapia Guiada por Imagem/métodos , Tomografia Computadorizada por Raios X/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...