Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Neurophotonics ; 11(2): 025004, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38812966

RESUMO

Significance: People with Parkinson's disease (PD) experience changes in fine motor skills, which is viewed as one of the hallmark signs of this disease. Due to its non-invasive nature and portability, functional near-infrared spectroscopy (fNIRS) is a promising tool for assessing changes related to fine motor skills. Aim: We aim to compare activation patterns in the primary motor cortex using fNIRS, comparing volunteers with PD and sex- and age-matched control participants during a fine motor task and walking. Moreover, inter and intrahemispheric functional connectivity (FC) was investigated during the resting state. Approach: We used fNIRS to measure the hemodynamic changes in the primary motor cortex elicited by a finger-tapping task in 20 PD patients and 20 controls matched for age, sex, education, and body mass index. In addition, a two-minute walking task was carried out. Resting-state FC was also assessed. Results: Patients with PD showed delayed hypoactivation in the motor cortex during the fine motor task with the dominant hand and delayed hyperactivation with the non-dominant hand. The findings also revealed significant correlations among various measures of hemodynamic activity in the motor cortex using fNIRS and different cognitive and clinical variables. There were no significant differences between patients with PD and controls during the walking task. However, there were significant differences in interhemispheric connectivity between PD patients and control participants, with a statistically significant decrease in PD patients compared with control participants. Conclusions: Decreased interhemispheric FC and delayed activity in the primary motor cortex elicited by a fine motor task may one day serve as one of the many potential neuroimaging biomarkers for diagnosing PD.

2.
J Clin Exp Dent ; 15(5): e382-e389, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37214747

RESUMO

Background: Gutta-percha (Gp) is an inert thermoplastic polymer used as a filling to replace the dental pulp space, which has been reformulated to improve its three-dimensional sealing properties. Therefore, this study aimed to analyze the physical, chemical and thermal properties of two types of gutta-percha filling. As well as measuring the temperature distribution along the cone at the time of cutting through an in-situ test. Material and Methods: Two commercially available brands of gutta-percha point were investigated: Conform Fit TM Gutta-Percha for ProTaper Gold® (PTG) (Dentsply Sirona), and Hygenic Gutta-Percha (Coltene whaledent). Differential scanning calorimetry (DSC) and thermogravimetric analysis (TGA) were selected for the thermal characterization of materials, and Fourier Transform Infrared Spectroscopy (FT-IR) for the chemical analysis of Gp cones. Regarding temperature distribution, it was evaluated using a thermographic camera (FLIR ONE® PRO by MicroUSB P/N 435-0011-01) at 0 to 20 s after the cutting process (n=11/group). Results: Both materials have three fusion endotherms associated with the three crystalline phases of Gp, with similar temperatures but enthalpies that differ by 60%, the fusion enthalpy being higher for Conform Fit. In the chemical characterization, elements such as Zn, C, O, Ba, S and Si were found in both materials but in different proportions. Regarding the content of fillers, the Conform Fit presented around 30% of Gp polymer and 25% for the Hygenic. The morphological characterization shows a microtexturized coating in the form of bars on a micrometric scale for the Conform Fit, which could favor a better three-dimensional seal. In addition to that, in heat transfer studies they showed greater temperature control. Conclusions: The characterization of the materials allowed us to see the variation in terms of their composition and configuration to the Gp cones of two commercial brands. These variations directly modify the thermal behavior of the material. Key words:Gutta-percha, Conform Fit, Infrared thermography, Differential Scanning Calorimetry, Infrared Spectroscopy.

3.
Int J Mol Sci ; 24(2)2023 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-36674917

RESUMO

There is a significant change in the bacterial plaque populations in the oral cavity during and after orthodontic treatment. Numerous studies have demonstrated that 2−96% of patients could increase the risk of white spot lesions. Streptococcus mutans and Lactobacilli ssp. are responsible for these white spot lesions. In this work, silver nanoparticles (AgNPs) with a diameter of 11 nm and dispersed in water were impregnated onto three different commercial orthodontic adhesives at 535 µg/mL. The shear bond strength (SBS) was assessed on 180 human premolars and metallic brackets. The premolars were divided into six groups (three groups for the commercial adhesives and three groups for the adhesives with AgNPs). All the groups were tested for their bactericidal properties, and their MIC, MBC, and agar template diffusion assays were measured. After adding AgNPs, the SBS was not significantly modified for any adhesive (p > 0.05), and the forces measured during the SBS did not exceed the threshold of 6 to 8 MPa for clinical acceptability in all groups. An increase in the bactericidal properties against both S. mutans and L. acidophilus was measured when the adhesives were supplemented with AgNPs. It was concluded that AgNPs can be supplement commercial orthodontic adhesives without modifying their mechanical properties with improved bactericidal activity.


Assuntos
Colagem Dentária , Cárie Dentária , Nanopartículas Metálicas , Humanos , Propriedades de Superfície , Nanopartículas Metálicas/química , Prata/farmacologia , Prata/química , Antibacterianos/farmacologia , Antibacterianos/química , Cimentos Dentários/farmacologia , Cárie Dentária/prevenção & controle , Resistência ao Cisalhamento , Teste de Materiais
4.
Nanomaterials (Basel) ; 11(7)2021 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-34203448

RESUMO

A nanoparticle's shape and size determine its optical properties. Nanorods are nanoparticles that have double absorption bands associated to surface plasmon oscillations along their two main axes. In this work, we analize the optical response of gold nanorods with numerical simulations and spectral absorption measurements to evaluate their local field enhancement-which is key for surface-enhanced Raman spectroscopic (SERS) applications. Our experimental results are in good agreement with finite element method (FEM) simulations for the spectral optical absorption of the nanoparticles. We also observed a strong dependence of the optical properties of gold nanorods on their geometrical dimension and shape. Our numerical simulations helped us reveal the importance of the nanorods' morphology generated during the synthesis stage in the evaluation of absorption and local field enhancement. The application of these gold nanorods in surface-enhancement Raman spectroscopy is analyzed numerically, and results in a 5.8×104 amplification factor when comparing the values obtained for the nanorod deposited on a dielectric substrate compared to the nanorod immersed in water.

5.
Nanomaterials (Basel) ; 9(2)2019 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-30736293

RESUMO

In this paper, we report a fast and easy method to detect histamine dihydrochloride using gold nanostars in colloidal aqueous solution as a highly active SERS platform with potential applications in biomedicine and food science. This colloid was characterized with SEM and UV⁻Vis spectroscopy. Also, numerical calculations were performed to estimate the plasmonic resonance and electric field amplification of the gold nanoparticles to compare the difference between nanospheres and nanostars. Finally, aqueous solutions of histamine dihydrochloride were prepared in a wide range of concentrations and the colloid was added to carry out SERS. We found SERS amplified the Raman signal of histamine by an enhancement factor of 1 . 0 × 10 7 , demonstrating the capability of the method to detect low concentrations of this amine molecule.

6.
PLoS One ; 13(11): e0206477, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30427892

RESUMO

BACKGROUND: The clinical evaluation of a burn wound alone may not be adequate to predict the severity of the injury nor to guide clinical decision making. Infrared thermography provides information about soft tissue viability and has previously been used to assess burn depth. The objective of this study was to determine if temperature differences in burns assessed by infrared thermography could be used predict the treatment modality of either healing by re-epithelization, requiring skin grafts, or requiring amputations, and to validate the clinical predication algorithm in an independent cohort. METHODS AND FINDINGS: Temperature difference (ΔT) between injured and healthy skin were recorded within the first three days after injury in previously healthy burn patients. After discharge, the treatment modality was categorized as re-epithelization, skin graft or amputation. Potential confounding factors were assessed through multiple linear regression models, and a prediction algorithm based on the ΔT was developed using a predictive model using a recursive partitioning Random Forest machine learning algorithm. Finally, the prediction accuracy of the algorithm was compared in the development cohort and an independent validation cohort. Significant differences were found in the ΔT between treatment modality groups. The developed algorithm correctly predicts into which treatment category the patient will fall with 85.35% accuracy. Agreement between predicted and actual treatment for both cohorts was weighted kappa 90%. CONCLUSION: Infrared thermograms obtained at first contact with a wounded patient can be used to accurately predict the definitive treatment modality for burn patients. This method can be used to rationalize treatment and streamline early wound closure.


Assuntos
Algoritmos , Queimaduras/diagnóstico por imagem , Queimaduras/terapia , Termografia , Adulto , Queimaduras/fisiopatologia , Estudos de Coortes , Feminino , Humanos , Masculino , Estudos Prospectivos , Temperatura , Resultado do Tratamento , Cicatrização , Adulto Jovem
7.
Sensors (Basel) ; 15(1): 1998-2005, 2015 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-25602271

RESUMO

In this article nickel interdigital capacitors were fabricated on top of silicon substrates. The capacitance of the interdigital capacitor was optimized by coating the electrodes with a 60 nm layer of HfO2. An analytical solution of the capacitance was compared to electromagnetic simulations using COMSOL and with experimental measurements. Results show that modeling interdigital capacitors using Finite Element Method software such as COMSOL is effective in the design and electrical characterization of these transducers.


Assuntos
Capacitância Elétrica , Nanopartículas/química , Nanotecnologia/métodos , Animais , Bovinos , Simulação por Computador , Desenho de Equipamento , Análise Numérica Assistida por Computador , Soroalbumina Bovina/metabolismo , Eletricidade Estática
8.
J Biomed Opt ; 18(6): 061204, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23111601

RESUMO

Digital infrared thermal imaging is used to assess noninvasively the severity of burn wounds in 13 pediatric patients. A delta-T (ΔT) parameter obtained by subtracting the temperature of a healthy contralateral region from the temperature of the burn wound is compared with the burn depth measured histopathologically. Thermal imaging results show that superficial dermal burns (IIa) show increased temperature compared with their contralateral healthy region, while deep dermal burns (IIb) show a lower temperature than their contralateral healthy region. This difference in temperature is statistically significant (p<0.0001) and provides a way of distinguishing deep dermal from superficial dermal burns. These results show that digital infrared thermal imaging could be used as a noninvasive procedure to assess burn wounds. An additional advantage of using thermal imaging, which can image a large skin surface area, is that it can be used to identify regions with different burn depths and estimate the size of the grafts needed for deep dermal burns.


Assuntos
Queimaduras/diagnóstico , Queimaduras/patologia , Processamento de Imagem Assistida por Computador/métodos , Pele/química , Pele/patologia , Termografia/métodos , Adolescente , Queimaduras/classificação , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Raios Infravermelhos , Masculino , Gravidade do Paciente
9.
Skin Res Technol ; 17(3): 326-31, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21338404

RESUMO

BACKGROUND: Infrared thermography can be a valuable diagnostic tool in the evaluation and management of several pathologies; however, the temperature pattern of the healthy body should be known in order to perform a more precise clinical evaluation. METHODS: A total of 25 healthy children (10 female and 15 male) were examined with a thermographic camera. Eighty-four temperature points of the body were recorded, saved in a database, and analyzed. RESULTS: The measurements showed that the forehead, neck, and the cervical area have the highest average temperatures of the whole body, and that the temperature distribution between boys and girls is very similar. The difference in skin temperature along the y-axis of the body varied up to 5.1°C; however, the average difference in skin temperature along the x-axis of the body was 0.7°C. These temperature variations observed in children are lower than the ones reported for adults, which could be due to a greater variation of body fat distribution in adults. CONCLUSION: This study shows that thermography could be a good tool for disease diagnosis in children as there is a lower skin temperature variation among children than among adults.


Assuntos
Regulação da Temperatura Corporal/fisiologia , Temperatura Cutânea/fisiologia , Termografia/estatística & dados numéricos , Imagem Corporal Total/estatística & dados numéricos , Adolescente , Criança , Pré-Escolar , Feminino , Humanos , Raios Infravermelhos , Masculino , México/epidemiologia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Distribuição por Sexo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA