1.
J Am Dent Assoc ; 129(7): 985-91, 1998 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-9685763

RESUMO

Using the Food and Drug Administration's protocol for testing health care sterilizers, the author investigated the ability of chemical vapor and steam to sterilize handpieces. Five internal sites of six high-speed handpiece models and four internal positions of one low-speed handpiece model were each inoculated with 10(6) Bacillus stearothermophilus spores. Half-cycle challenges were conducted with Chemiclave models EC 5500 and 8000 (Barnstead/Thermolyne) and with two autoclaves, Tuttnauer 2540M (large chamber) (Tuttnauer USA Co., Ltd.) and Statim Cassette (SciCan USA). Experiments with spores either openly exposed or partially enclosed prove that chemical vapor is an excellent lethal agent, but strongly suggest penetration weakness [corrected].


Assuntos
Instrumentos Odontológicos/microbiologia , Contaminação de Equipamentos/prevenção & controle , Esterilização/instrumentação , Equipamentos Odontológicos de Alta Rotação/microbiologia , Desinfetantes/administração & dosagem , Desenho de Equipamento , Geobacillus stearothermophilus/crescimento & desenvolvimento , Humanos , Teste de Materiais , Esporos Bacterianos/crescimento & desenvolvimento , Vapor , Esterilização/métodos , Esterilização/normas , Estados Unidos , United States Food and Drug Administration , Volatilização
2.
Int J Prosthodont ; 7(5): 473-8, 1994.
Artigo em Inglês | MEDLINE | ID: mdl-7802917

RESUMO

Denture stomatitis affects approximately 65% of all denture wearers and Candida albicans has been established as a primary etiologic agent. Treatment of the condition necessitates removal of the organism from denture resins by soaking in cleansing/disinfecting solutions. These solutions can have deleterious effects on denture resins. Physical properties (flexure strength and surface hardness) of heat- and light-polymerized denture resins (Lucitone Pink and Triad) were evaluated after candidal colonization and candidal treatment regimens. Light-activated resins may be the materials of choice for patients prone to denture stomatitis, as they have demonstrated less overall degradation from candidal treatment modalities.


Assuntos
Resinas Acrílicas/química , Bases de Dentadura , Higienizadores de Dentadura/química , Análise de Variância , Benzoatos/química , Benzoatos/farmacologia , Ácido Benzoico , Candida albicans/efeitos dos fármacos , Elasticidade , Dureza , Teste de Materiais , Nistatina , Resistência à Tração , Fatores de Tempo
3.
J Am Dent Assoc ; 125(1): 51-4, 1994 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-8031354

RESUMO

Achieving maximum equipment sterilization is critical. Factors that contribute to sterilization efficiency are covered, including sterilization accuracy level, chamber loading and biological indicators.


Assuntos
Equipamentos Odontológicos , Contaminação de Equipamentos , Esterilização/normas , Contagem de Colônia Microbiana , Eficiência , Temperatura Alta , Humanos , Esporos Bacterianos , Vapor , Esterilização/legislação & jurisprudência , Esterilização/métodos , Estados Unidos , United States Food and Drug Administration
7.
Compendium ; 11(11): 687-8, 1990 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-2128473

RESUMO

The U.S. Environmental Protection Agency (EPA) officially licenses and authorizes use of commercial gas and liquid sterilants. Products registered by the EPA include ethylene oxide gas, formalin-alcohol vapor, glutaraldehyde liquid, and chlorine dioxide liquid. One product that is exempted from EPA registration is the STER-O-LIZER MD 200, in which the active component is electropotentiated saline solution. The manufacturer of the STER-O-LIZER claims that the device sterilizes surgical instruments in 2 minutes. Sterilization claims for the product are based on a test selected by the manufacturer. The EPA, however, is not concerned about the use of the STER-O-LIZER because it is non-toxic to humans. This study tested the validity of the manufacturer's claim by using EPA standards.


Assuntos
Esterilização/instrumentação , Bacillus subtilis , Clostridium , Falha de Equipamento , Esporos Fúngicos , Instrumentos Cirúrgicos , Estados Unidos , United States Environmental Protection Agency
8.
J Clin Orthod ; 22(12): 768-9, 1988 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-3254371
9.
J Prosthet Dent ; 55(6): 699-700, 1986 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-3522864

RESUMO

Benzoic acid combined with a detergent was used to safely and effectively decontaminate dentures colonized with Candida albicans. Surface decontamination was accomplished by soaking the dentures in the germicide solution for a period of 6 hours to overnight. Decontamination may occur in as little as 10 minutes when soaking is combined with ultrasonic enhancement.


Assuntos
Benzoatos/farmacologia , Candida albicans/efeitos dos fármacos , Dentifrícios/farmacologia , Higienizadores de Dentadura/farmacologia , Dentaduras , Detergentes/farmacologia , Tensoativos/farmacologia , Ácido Benzoico , Candida albicans/isolamento & purificação , Fatores de Tempo , Ultrassom
10.
J Dent Educ ; 49(12): 799-803, 1985 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-3864827

RESUMO

Performance on classroom achievement tests should reflect student accomplishment on a targeted set of instructional objectives. One prerequisite for meaningful edumetric assessment is the structuring of each component item in an appropriate format. In a comparative study measuring the effect of item format on student performance, incorrect choices were selected 2.4-fold more frequently on multiple choice items than on their content-identical, multiple true-false derivatives. On similar trials, scores on complex multiple-choice items ranged upward of 20 percent higher than on their content-identical, multiple true-false counterparts. The strengths and weaknesses of various test item formats are discussed and specific recommendations for format selection are made.


Assuntos
Avaliação Educacional/métodos , Logro , Testes de Aptidão , Humanos
14.
J Dent Educ ; 46(8): 485-8, 1982 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-6954178

RESUMO

Multiple-choice items are frequently used in objective examinations. The format chosen should conform to the nature of the instruction. Knowledge about cumulative information, such as lists of attributes, can be tested efficiently by means of multiple-choice items that include a variable number of correct answers. In contrast to conventional, single-answer questions, nonrestricted multiple-choice items are capable of including more facts and fewer incorrect responses. In addition, the nonrestricted format is not burdened with the repetitious pattern of one correct answer coupled with several incorrect responses, a cue that may promote successful guessing. Item analyses can be performed on examinations that include both conventional and nonrestricted items. The reliability of one examination constructed totally with nonrestricted items was analyzed by means of the Kuder-Richardson Formula No. 20. The value 0.72 proved this examination to be both discriminating and consistent.


Assuntos
Avaliação Educacional/métodos , Educação em Odontologia , Projetos de Pesquisa
15.
J Periodontol ; 53(7): 434-8, 1982 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-6956709

RESUMO

The sharpness of surgical instruments is of particular importance to the periodontist. In order to study the effects of sterilization on the cutting edges of periodontal curets and scalers, new sharpened instruments were sterilized 10 cycles with saturated steam, formalin-alcohol vapor or dry heat. The instruments were evaluated before and after sterilization with a scanning electron microscope. No visual damage to the cutting edges of stainless steel instruments was evident after sterilization by saturated steam at 250 degrees F, formalin-alcohol vapor at 270 degrees F or dry heat up to 340 degrees F. Carbon steel instruments were not damaged by formalin-alcohol vapor at 270 degrees F or dry heat up to 340 degrees F. Saturated steam caused oxidation and dulling of carbon steel instruments.


Assuntos
Periodontia/instrumentação , Esterilização , Carbono , Microscopia Eletrônica de Varredura , Aço Inoxidável , Esterilização/métodos , Propriedades de Superfície , Temperatura
18.
J Clin Microbiol ; 5(5): 517-20, 1977 May.
Artigo em Inglês | MEDLINE | ID: mdl-874072

RESUMO

A typing system based on bacteriocin production and sensitivity for Streptococcus sanguis strains was devised. Bacteriocin producer strains were grown (37degrees C) anaerobically on brain heart infusion-yeast extract agar for 18 h. Bacteriocin indicator strains were suspended to molten brain heart infusion-yeast extract agar and then overlayed onto the producer strain. After an additional 18 to 24 h of incubation, zones of bacteriocin inhibition were recorded. After establishment of the typing system, eight Streptococcus strains from bacterial endocarditis patients were characterized by the typing system. Four patient strains had identical bacteriocin reduction patterns but could be differentiated by differences in their bacteriocin sensitivity. Two isolates from the same patient had identical production and sensitivity patterns. By including both bacteriocin production and bacteriocin sensitivity, all seven epidemiologically unrelated isolates could be differentiated. On the basis of these results, there does not appear to be a correlation between bacteriocin production and infectivity, but the usefulness of the application of a typing system to a clinical situation is demonstrated.


Assuntos
Bacteriocinas , Endocardite Bacteriana/microbiologia , Streptococcus sanguis/classificação , Streptococcus/classificação , Anaerobiose , Bacteriocinas/biossíntese , Bacteriocinas/farmacologia , Resistência Microbiana a Medicamentos , Humanos , Streptococcus/efeitos dos fármacos , Streptococcus/metabolismo , Streptococcus sanguis/efeitos dos fármacos , Streptococcus sanguis/metabolismo
19.
J Dent Res ; 55: A154-65, 1976 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-1107377

RESUMO

Strain-typing methods utilizing microbial antagonism have been developed for S sanguis and for S mutans. The inhibition observed resembled that of bacteriocins. Inhibition within the species S sanguis was obtained with group D streptococci and facultative members of the genus Bacillus. Thirty-three inhibitors were paired (not in all possible combinations) with 37 isolates of S sanguis. Depending on the inhibitor, growth of between 15 and 85% of the sensitive indicators was halted. Three of the inhibitors manifested identical patterns of inhibition. Of the 37 S sanguis isolates, 34 exhibited individual patterns of inhibition. The three exceptions could be differentiated by their antagonism against sensitive indicators of S mutans. Variations in susceptibility to antagonism produced by group D streptococci allowed each of ten strains of S mutans to be typed. Present work for typing the oral streptococci is focused on computer-assisted searches for minimal typing sets. S mutans is sensitive to inhibition by some members of the species S sanguis. From a group of 58 challengers, 44 inhibited at least one of ten strains of S mutans, and 11 strains of S sanguis were able to halt the growth of half or more of the sensitive indicators. These results are useful not only for strain typing but form the basis for in vivo competition studies.


Assuntos
Boca/microbiologia , Streptococcus sanguis/classificação , Streptococcus/classificação , Antibiose , Bacillus/fisiologia , Técnicas Bacteriológicas , Humanos , Streptococcus/fisiologia , Streptococcus mutans/fisiologia , Streptococcus sanguis/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA