Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Chromatogr A ; 1678: 463340, 2022 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-35905682

RESUMO

The experimental design methodology based on central composite design of experiments was applied to compare the retention mechanisms in supercritical fluid chromatography (SFC) and non-aqueous hydrophilic interaction liquid chromatography (NA-HILIC). The selected set consists of 26 compounds that belong to imidazoline and serotonin receptor ligands. The different chemometric tools (multiple linear regression, principal component analysis, parallel factor analysis) were used to examine the retention, as well as to identify the most significant retention mechanisms. The retention mechanism was investigated on two different stationary phases (diol, and mixed-mode diol). In NA-HILIC, the mobile phase contains acetonitrile as a main component, and methanolic solution of ammonium formate (+ 0.1% of formic acid) as a modifier. The same mobile phase modifier was used in SFC, with a difference in the main component of the mobile phase which was CO2. The retention behaviour differs significantly between HILIC and SFC conditions. The retention pattern in HILIC mode was more partition-like, while in SFC the solute-sorbent interactions allowed retention. The retention mechanism between mixed-mode diol and the diol phases varies depending on the applied chromatographic mode, e.g., in HILIC the type of stationary phase significantly affects the elution order, while in SFC this was not the case. The HILIC retention behaviour was influenced by the number of tertiary amines-aliphatic, and N atom-centred fragments in tested compounds. On the other hand, the number of pyrrole and pyridine rings in the structure of the compound showed correlation with their SFC retention, simultaneously increasing the molecular weight and rapid elution of larger compounds. It was found that temperature surprisingly plays a major role in SFC mode. The increase in temperature reduces the relative contribution of enthalpy factors to total retention, so the separation in SFC was more entropy-controlled. For further pharmaceutical research and optimization, the SFC would be considered more beneficial compared to HILIC since it gives good selectivity in separation of chosen impurities.


Assuntos
Cromatografia com Fluido Supercrítico , Imidazolinas , Álcoois , Quimiometria , Cromatografia com Fluido Supercrítico/métodos , Interações Hidrofóbicas e Hidrofílicas , Piperazina
2.
Physiol Behav ; 185: 112-120, 2018 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-29294304

RESUMO

Preclinical data indicated that the metabotropic glutamate receptors 5 (mGlu5) and glutamate receptors 2/3 (mGlu2/3) are involved in modulating morphine antinociception. However, little is known about the role of metabotropic glutamate receptors 7 (mGlu7) in this phenomenon. We compared the effects of AMN082 (0.1, 1 or 5mg/kg, ip), a selective mGlu7 allosteric agonist, LY354740 (0.1, 1 or 5mg/kg, ip), an mGlu2/3 agonist and MTEP (0.1, 1 or 5mg/kg, ip), a selective mGlu5 antagonist, on the acute antinociceptive effect of morphine (5mg/kg, sc) and also on the development and expression of tolerance to morphine analgesia in the tail-immersion test in mice. To determine the role of mGlu7 in morphine tolerance, and the association of the mGlu7 effect with the N-methyl-d-aspartate (NMDA) receptors regulation, we used MMPIP (10mg/kg, ip), a selective mGlu7 antagonist and MK-801, a NMDA antagonist. Herein, the acute administration of AMN082, MTEP or LY354740 alone failed to evoked antinociception, and did not affect morphine (5mg/kg, sc) antinociception. However, these ligands inhibited the development of morphine tolerance, and we indicated that MMPIP reversed the inhibitory effect of AMN082. When given together, the non-effective doses of AMN082 and MK-801 did not alter the tolerance to morphine. Thus, mGlu7, similarly to mGlu2/3 and mGlu5, are involved in the development of tolerance to the antinociceptive effects of morphine, but not in the acute morphine antinociception. Furthermore, while mGlu7 are engaged in the development of morphine tolerance, no interaction exists between mGlu7 and NMDA receptors in this phenomenon.


Assuntos
Analgésicos/farmacologia , Compostos Benzidrílicos/farmacologia , Agonistas de Aminoácidos Excitatórios/farmacologia , Morfina/farmacologia , Dor Nociceptiva/tratamento farmacológico , Receptores de Glutamato Metabotrópico/agonistas , Regulação Alostérica , Animais , Compostos Bicíclicos com Pontes/farmacologia , Maleato de Dizocilpina/farmacologia , Relação Dose-Resposta a Droga , Tolerância a Medicamentos , Antagonistas de Aminoácidos Excitatórios/farmacologia , Masculino , Camundongos , Dor Nociceptiva/metabolismo , Piridinas/farmacologia , Piridonas/farmacologia , Distribuição Aleatória , Receptores de Glutamato Metabotrópico/metabolismo , Receptores de N-Metil-D-Aspartato/antagonistas & inibidores , Receptores de N-Metil-D-Aspartato/metabolismo , Cauda , Tiazóis/farmacologia
3.
Artigo em Inglês | MEDLINE | ID: mdl-25448778

RESUMO

Previous studies have indicated that metabotropic glutamate receptors 7 (mGluR7s) are involved in drug addiction. However, the role of these receptors in drug-induced behavioral sensitization is unknown. The aim of the present study was to determine whether systemic injection of AMN082, a selective mGluR7 allosteric agonist, reduces the cocaine- and morphine-induced hyperactivity and the development and expression of locomotor sensitization, and also affects the reciprocal cross-sensitization to the stimulant effect of cocaine and morphine in mice. AMN082 (1.25-10.0 mg/kg, i.p.) did not have an impact on locomotion of naive mice and did not affect the acute cocaine- or morphine-induced hyperactivity, except the dose of 10 mg/kg that suppressed the locomotor effect of both drugs. Repeated exposure to cocaine or morphine (10 mg/kg, 5× every 3 days) gradually increased locomotion during induction of sensitization and after 4 (cocaine) or 7 day (morphine) withdrawal phase when challenged with cocaine (10 mg/kg, i.p.) or morphine (10 mg/kg, i.p.) on day 17 or 20, respectively. Pretreatment of animals with the lower doses of AMN082 (1.25-5.0 mg/kg, i.p.), 30 min before every cocaine or morphine injection during repeated drug administration or before cocaine or morphine challenge, dose-dependently attenuated the development, as well as the expression of cocaine or morphine locomotor sensitization. AMN082 also inhibited the reciprocal cross-sensitization between these drugs. Prior to administration of MMPIP (10 mg/kg, i.p.), a selective mGluR7 antagonist reversed the inhibitory effect of AMN082 on the development or expression of cocaine or morphine sensitization. These data indicate that AMN082 attenuated the development and expression of cocaine and morphine sensitization, and the reciprocal cross-sensitization via a mechanism that involves mGluR7s. Thus, AMN082 might have therapeutic implications not only in the treatment of cocaine or opioid addiction but also in the treatment of cocaine/opioid polydrug-abusers.


Assuntos
Compostos Benzidrílicos/farmacologia , Sensibilização do Sistema Nervoso Central/efeitos dos fármacos , Cocaína/antagonistas & inibidores , Locomoção/efeitos dos fármacos , Morfina/antagonistas & inibidores , Receptores de Glutamato Metabotrópico/agonistas , Regulação Alostérica/efeitos dos fármacos , Animais , Cocaína/farmacologia , Relação Dose-Resposta a Droga , Interações Medicamentosas , Masculino , Camundongos , Morfina/farmacologia , Piridonas/farmacologia , Receptores de Glutamato Metabotrópico/antagonistas & inibidores
5.
Chromatographia ; 73(7-8): 721-731, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21516139

RESUMO

The article is intended to introduce and discuss a new quantile regression method for baseline detrending of chromatographic signals. It is compared with current methods based on polynomial fitting, spline fitting, LOESS, and Whittaker smoother, each with thresholding and reweighting approach. For curve flexibility selection in existing algorithms, a new method based on skewness of the residuals is successfully applied. The computational efficiency of all approaches is also discussed. The newly introduced methods could be preferred to visible better performance and short computational time. The other algorithms behave in comparable way, and polynomial regression can be here preferred due to short computational time.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA