Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 94(3): 033501, 2023 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-37012789

RESUMO

A multipurpose imaging x-ray crystal spectrometer is developed for the high energy density instrument of the European X-ray Free Electron Laser. The spectrometer is designed to measure x rays in the energy range of 4-10 keV, providing high-resolution, spatially resolved spectral measurements. A toroidally bent germanium (Ge) crystal is used, allowing x-ray diffraction from the crystal to image along a one-dimensional spatial profile while spectrally resolving along the other. A detailed geometrical analysis is performed to determine the curvature of the crystal. The theoretical performance of the spectrometer in various configurations is calculated by ray-tracing simulations. The key properties of the spectrometer, including the spectral and spatial resolution, are demonstrated experimentally on different platforms. Experimental results prove that this Ge spectrometer is a powerful tool for spatially resolved measurements of x-ray emission, scattering, or absorption spectra in high energy density physics.

2.
J Synchrotron Radiat ; 28(Pt 3): 688-706, 2021 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-33949979

RESUMO

The high-precision X-ray diffraction setup for work with diamond anvil cells (DACs) in interaction chamber 2 (IC2) of the High Energy Density instrument of the European X-ray Free-Electron Laser is described. This includes beamline optics, sample positioning and detector systems located in the multipurpose vacuum chamber. Concepts for pump-probe X-ray diffraction experiments in the DAC are described and their implementation demonstrated during the First User Community Assisted Commissioning experiment. X-ray heating and diffraction of Bi under pressure, obtained using 20 fs X-ray pulses at 17.8 keV and 2.2 MHz repetition, is illustrated through splitting of diffraction peaks, and interpreted employing finite element modeling of the sample chamber in the DAC.

4.
Rev Sci Instrum ; 92(1): 013101, 2021 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-33514249

RESUMO

We introduce a setup to measure high-resolution inelastic x-ray scattering at the High Energy Density scientific instrument at the European X-Ray Free-Electron Laser (XFEL). The setup uses the Si (533) reflection in a channel-cut monochromator and three spherical diced analyzer crystals in near-backscattering geometry to reach a high spectral resolution. An energy resolution of 44 meV is demonstrated for the experimental setup, close to the theoretically achievable minimum resolution. The analyzer crystals and detector are mounted on a curved-rail system, allowing quick and reliable changes in scattering angle without breaking vacuum. The entire setup is designed for operation at 10 Hz, the same repetition rate as the high-power lasers available at the instrument and the fundamental repetition rate of the European XFEL. Among other measurements, it is envisioned that this setup will allow studies of the dynamics of highly transient laser generated states of matter.

5.
Rev Sci Instrum ; 91(12): 123501, 2020 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-33379989

RESUMO

Small angle x-ray scattering (SAXS) is a well established technique to detect nanometer scale structures in matter. In a typical setup, this diagnostic uses a detector with a direct line of sight to the scattering target. However, in the harsh environment of high intensity laser interaction, intense secondary radiation and high-energy particles are generated. Such a setup would therefore suffer a significant increase of noise due to this background, which could eventually prevent such measurements. In this paper, we present a novel tool consisting of a mosaic graphite crystal that works as a mirror for the SAXS signal and allows us to position the detector behind appropriate shielding. This paper studies the performance of this mirror both by experiment at the European XFEL (X-Ray Free-Electron Laser Facility) laboratory and by simulations.

6.
Rev Sci Instrum ; 90(6): 065114, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31255042

RESUMO

Fast compression experiments performed using dynamic diamond anvil cells (dDACs) employing piezoactuators offer the opportunity to study compression-rate dependent phenomena. In this paper, we describe an experimental setup which allows us to perform time-resolved x-ray diffraction during the fast compression of materials using improved dDACs. The combination of the high flux available using a 25.6 keV x-ray beam focused with a linear array of compound refractive lenses and the two fast GaAs LAMBDA detectors available at the Extreme Conditions Beamline (P02.2) at PETRA III enables the collection of x-ray diffraction patterns at an effective repetition rate of up to 4 kHz. Compression rates of up to 160 TPa/s have been achieved during the compression of gold in a 2.5 ms fast compression using improved dDAC configurations with more powerful piezoactuators. The application of this setup to low-Z compounds at lower compression rates is described, and the high temporal resolution of the setup is demonstrated. The possibility of applying finely tuned pressure profiles opens opportunities for future research, such as using oscillations of the piezoactuator to mimic propagation of seismic waves in the Earth.

7.
J Phys Condens Matter ; 30(8): 084004, 2018 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-29328058

RESUMO

Niobium (Nb) is one of the key trace elements used to understand Earth's formation and differentiation, and is remarkable for its deficiency relative to tantalum in terrestrial rocks compared to the building chondritic blocks. In this context, the local environment of Nb in silica-rich melts and glasses is studied by in situ x-ray absorption spectroscopy (XAS) at high pressure (P) up to 9.3 GPa and 1350 K using resistive-heating diamond-anvil cells. Nb is slightly less oxidized in the melt (intermediate valence between +4 and +5) than in the glass (+5), an effect evidenced from the shift of the Nb-edge towards lower energies. Changes in the pre-edge features are also observed between melt and glass states, consistently with the observed changes in oxidation state although likely enhanced by temperature (T) effects. The oxidation state of Nb is not affected by pressure neither in the molten nor glassy states, and remains constant in the investigated P-range. The Nb-O coordination number is constant and equal to [Formula: see text] below 5 GPa, and only progressively increases up to [Formula: see text] at 9.3 GPa, the maximum P investigated. If these findings were to similarly apply to basaltic melts, that would rule out the hypothesis of Nb/Ta fractionation during early silicate Earth's differentiation, thus reinforcing the alternative hypothesis of fractionation during core formation on reduced pre-planetary bodies.

8.
J Synchrotron Radiat ; 22(4): 908-24, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26134794

RESUMO

A detailed description is presented of the Extreme Conditions Beamline P02.2 for micro X-ray diffraction studies of matter at simultaneous high pressure and high/low temperatures at PETRA III, in Hamburg, Germany. This includes performance of the X-ray optics and instrumental resolution as well as an overview of the different sample environments available for high-pressure studies in the diamond anvil cell. Particularly emphasized are the high-brilliance and high-energy X-ray diffraction capabilities of the beamline in conjunction with the use of fast area detectors to conduct time-resolved compression studies in the millisecond time regime. Finally, the current capability of the Extreme Conditions Science Infrastructure to support high-pressure research at the Extreme Conditions Beamline and other PETRA III beamlines is described.

9.
J Phys Condens Matter ; 25(34): 346002, 2013 Aug 28.
Artigo em Inglês | MEDLINE | ID: mdl-23899699

RESUMO

The pressure dependence of the saturation magnetization and Curie temperature was studied in melt-spun Fe60Mn20B20, Fe56Mn24B20 and Fe75B25 amorphous alloys up to 0.9 GPa, corresponding to volume changes up to 0.45%. In addition, in situ high-pressure (up to 40 GPa) x-ray diffraction was performed to determine the compressibility of the latter two alloys. Both the Curie temperature TC (at atmospheric pressure TC = 201 ± 3 and 159 ± 3 K) and the low-temperature saturation magnetization M5 K,5 T decrease remarkably with increasing pressure: dTC/dp =- 31 ± 0.5 and -32 ± 5 K GPa(-1) and dlnM5 K,5 T/dp =- 0.15 ± 0.02 and -0.13 ± 0.03 GPa(-1) for xMn = 20 and 24 at.%, respectively. Compared to dlnM5 K,5 T/dp =- 0.016 ± 0.003 GPa(-1) measured for Fe75B25, the pressure dependence of M5 K,5 T is one order of magnitude larger in the ternary alloys. The bulk moduli for the Fe56Mn24B20 and Fe75B25 glasses were measured to be 152 GPa and 173 GPa, respectively. These data are also compared with the pressure dependence of the hyperfine field and theoretical calculations of the saturation moment for Fe-B alloys reported in the literature. The results were interpreted within an inhomogeneous itinerant-electron model of ferromagnetism.

10.
Artigo em Inglês | MEDLINE | ID: mdl-23496539

RESUMO

We report on an x-ray diffraction (XRD) study of helical poly[9,9-bis(2-ethylhexyl)fluorene] (PF2/6) under high quasihydrostatic pressure and show an effect of pressure on the torsion angle (dihedral angle) between adjunct repeat units and on the hexagonal unit cell. A model for helical backbone conformation is constructed. The theoretical position for the most prominent 00l x-ray reflection is calculated as a function of torsion angle. The XRD of high molecular weight PF2/6 (M(n)=30 kg/mol) is measured through a diamond anvil cell upon pressure increase from 1 to 10 GPa. The theoretically considered 00l reflection is experimentally identified, and its shift with the increasing pressure is found to be consistent with the decreasing torsion angle between 2 and 6 GPa. This indicates partial backbone planarization towards a more open helical structure. The h00 peak is identified, and its shift together with the broadening of 00l implies impairment of the ambient hexagonal order, which begins at or below 2 GPa. Previously collected high-pressure photoluminescence data are reanalyzed and are found to be qualitatively consistent with the XRD data. This paper provides an example of how the helical π-conjugated backbone structure can be controlled by applying high quasihydrostatic pressure without modifications in its chemical structure. Moreover, it paves the way for wider use of high-pressure x-ray scattering in the research of π-conjugated polymers.


Assuntos
Fluorenos/química , Modelos Químicos , Modelos Moleculares , Simulação por Computador , Pressão Hidrostática , Conformação Molecular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...