Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 73
Filtrar
1.
Mod Rheumatol Case Rep ; 8(1): 163-171, 2023 Dec 29.
Artigo em Inglês | MEDLINE | ID: mdl-37417460

RESUMO

A 65-year-old man presented with apparent bronchopneumonia. After treatment with antibiotics, he showed eosinophilia. Computed tomography (CT) imaging revealed bilateral consolidation, ground-glass opacities with nodular consolidations, and pleural effusion. Lung biopsy showed organising pneumonia with lymphoplasmacytic infiltration in the alveolar septa and in the thickened pleura and interlobular septa. All pulmonary abnormalities spontaneously went into remission within 12 months. At 73 years old, a follow-up CT scan revealed small nodules in both lungs and the review of the head CT scan showed thickening of the pituitary stalk in studying prolonged headache. Two years later, he visited the hospital complaining of severe oedema on the lower extremities with high serum immunoglobulin (Ig)G4 186 mg/dl. A whole-body CT scan showed retroperitoneal mass surrounding aortic bifurcation and compressing inferior vena cava, pituitary stalk thickening and gland swelling, and enlarged pulmonary nodules. Anterior pituitary stimulation tests showed central hypothyroidism, central hypogonadism, and adult growth hormone deficiency with partial primary hypoadrenocorticism. Retroperitoneal mass biopsy showed storiform fibrosis and obliterative phlebitis with marked lymphoplasmacytic infiltration with moderate IgG4-positivity. Immunostaining of the former lung specimen revealed dense interstitial infiltration of IgG4-positive cells. These findings indicated metachronous development of IgG4-related disease in lung, hypophysis, and retroperitoneum, according to the recent comprehensive diagnostic criteria of IgG4-related disease. Glucocorticoid therapy ameliorated oedema, on the other hand, unmasked partial diabetes insipidus at the initial dose of the treatment. Hypothyroidism and retroperitoneal mass regressed at 6 months of the treatment. This case warns us that long-term follow-up from prodromal to remission is necessary for the treatment of IgG4-related disease.


Assuntos
Hipofisite , Doença Relacionada a Imunoglobulina G4 , Pneumopatias , Fibrose Retroperitoneal , Masculino , Adulto , Humanos , Idoso , Criança , Doença Relacionada a Imunoglobulina G4/complicações , Doença Relacionada a Imunoglobulina G4/diagnóstico , Doença Relacionada a Imunoglobulina G4/tratamento farmacológico , Fibrose Retroperitoneal/complicações , Fibrose Retroperitoneal/diagnóstico , Remissão Espontânea , Hipofisite/tratamento farmacológico , Imunoglobulina G/uso terapêutico , Edema
2.
Endocrine ; 67(1): 124-130, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31637657

RESUMO

PURPOSE: Radiation exposure has been reported to cause thyroid nodules. The study area was Karunagapally, which has several areas with high natural radiation levels derived from thorium and its decay products. Since thyroid abnormalities are more common in women, the focus was only on women. METHODS: The examinations included interview, ultrasonography of the thyroid and serum assays of free thyroxine (FT4), thyrotropin (TSH), and anti-thyroglobulin levels. Cumulative dose during the childhood and lifetime cumulative dose (lagged by 5 years) were estimated. RESULTS: We examined 524 female residents aged 17-73 years and found 75 cases of solitary solid thyroid nodules. The prevalence of thyroid nodules were 14.1 % (n = 42) in high dose panchayats and 14.5% (n = 33) in low-dose panchayats. In the logistic regression analysis adjusted for age, the prevalence of solitary thyroid nodule was not linearly related to childhood cumulative dose (P for trend = 0.159) and lifetime cumulative dose (P for trend = 0.333). The prevalence of thyroiditis and hypothyroidism was not related to natural radiation exposure. Serum levels of FT4 or TSH were not related to natural radiation exposure. CONCLUSIONS: The results obtained from the present study do not support the increase of solitary thyroid nodule, thyroiditis or hypothyroidism in relation to high-natural-background-radiation exposure.


Assuntos
Radiação de Fundo , Nódulo da Glândula Tireoide , Adolescente , Adulto , Idoso , Feminino , Humanos , Índia/epidemiologia , Pessoa de Meia-Idade , Prevalência , Nódulo da Glândula Tireoide/epidemiologia , Tireotropina , Tiroxina , Adulto Jovem
4.
J Nucl Med ; 52(5): 683-9, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21498534

RESUMO

UNLABELLED: To elucidate the prognostic role of (131)I radioactive iodine therapy (RIT), we conducted a retrospective cohort study analyzing the clinical factors that affect survival of postoperative patients with differentiated thyroid carcinoma (DTC). METHODS: We included 198 DTC patients with extrathyroidal extension who received total or near-total thyroidectomy and then RIT in our hospital from January 1997 to June 2009: patients with lymph node metastases only (n = 47), lung metastases without bone metastases (n = 105), or bone metastases and other distant metastases (lung, liver, brain, and skin) (n = 46). Hemithyroidectomy or subtotal thyroidectomy had been performed before total or near-total thyroidectomy in 59 patients. Disease-specific survival after initial RIT was statistically evaluated using relevant clinical parameters, including age at initial RIT, pathology, sex, therapeutic history before initial RIT, pre- and posttherapeutic serum thyroglobulin ("prethyroglobulin" and "postthyroglobulin," respectively) at initial RIT, thyroglobulin under thyroid-stimulating hormone stimulation at initial RIT ("peak thyroglobulin"), grade of uptake at scintigraphy, extent of metastasis, and number of total RITs. RESULTS: During follow-up after initial RIT (average, 5.37 y), 24 patients died from DTC (11 male patients and 13 female). The most common reasons for death were respiratory failure due to lung metastases (n = 11) and uncontrollable brain metastases (n = 6). Univariate analysis showed that disease-specific survival was related to the following factors: extent of metastasis, age at initial RIT (<45 y), prethyroglobulin (<125 ng/mL), peak thyroglobulin (<1,000 ng/mL), and interval from total thyroidectomy to initial RIT (<180 d). A past history of hemithyroidectomy or subtotal thyroidectomy was not related to disease-specific survival. Multivariate analysis showed 3 factors to be independent prognostic factors--grade of (131)I uptake at whole-body scintigraphy, extent of metastasis, and interval to RIT (P ≤ 0.001, 0.010, and 0.005, respectively)--and also showed that risk of death in patients with an interval over 180 d was 4.22 times higher than in those with an interval within 180 d. Kaplan-Meier analysis revealed that a shorter interval (180, 365, or 1,000 d) had prognostic value even in the subgroups 45 y or older, with lung metastases, and with bone metastases or more. CONCLUSION: The present study suggests that delaying initial RIT until more than 180 d after total thyroidectomy may result in poor survival for DTC patients.


Assuntos
Diferenciação Celular , Radioisótopos do Iodo/uso terapêutico , Neoplasias da Glândula Tireoide/patologia , Neoplasias da Glândula Tireoide/radioterapia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Estudos de Coortes , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Metástase Neoplásica/patologia , Metástase Neoplásica/radioterapia , Período Pós-Operatório , Prognóstico , Estudos Retrospectivos , Análise de Sobrevida , Neoplasias da Glândula Tireoide/diagnóstico , Neoplasias da Glândula Tireoide/cirurgia , Fatores de Tempo , Adulto Jovem
5.
Kaku Igaku ; 47(4): 479-96, 2010 Nov.
Artigo em Japonês | MEDLINE | ID: mdl-21404570

RESUMO

OBJECTIVE: This study sought to assess the safety, efficacy, impact on hypothyroid symptoms, and pharmacokinetics of SKG-02 (rhTSH, thyrotropin alfa) in the diagnostic follow-up of Japanese patients with well-differentiated thyroid carcinoma (WDTC). METHODS: Ten Japanese adults with WDTC were enrolled into a prospective, multicenter, open-label trial comparing diagnostic whole-body scintigraphy (dxWBS) and serum thyroglobulin (Tg) testing aided by SKG-02 versus these procedures aided by thyroid hormone withdrawal (THW). Patients were their own controls. Variables compared included scan set ability to detect radioiodine uptake by remnant or malignant thyroid tissue, scan set quality, diagnostic sensitivity of dxWBS and Tg testing alone or combined, frequency of hypothyroid signs/symptoms, and adverse events (AEs). SKG-02 pharmacokinetic variables including maximum concentration (Cmax), time to Cmax (Tmax) and the area under the time-concentration curve (AUC) were calculated. RESULTS: In a blinded evaluation by an independent committee of 3 nuclear medicine experts, 70% of SKG-02 dxWBS scan sets were rated "equivalent" (n = 7) or "superior" (n = 0) to their THW counterparts in ability to detect radioiodine uptake in healthy or malignant thyroid tissue. Therefore the study exceeded its primary endpoint of a 60% equivalence/superiority rate. SKG-02 Tg testing identified 3/3 cases of disease. Hypothyroid signs/symptoms were substantially more frequent during THW than during euthyroidism permitted by SKG-02 use. SKG-02 was well-tolerated, with no severe or serious drug-related AEs. Cmax was 240.8 +/- 65.9 microIU/ml, Tmax was 28.75 +/- 14.21 hr after the first SKG-02 injection, and AUC was 11,414 +/- 3,462 microIU hr/ml in 9 patients evaluable for pharmacokinetics. CONCLUSIONS: SKG-02 was safe and effective in the diagnostic follow-up of Japanese patients with WDTC, avoiding hypothyroid morbidity relative to THW. These and the pharmacokinetic findings were similar to those of overseas Phase III studies.


Assuntos
Carcinoma/diagnóstico por imagem , Neoplasias da Glândula Tireoide/diagnóstico por imagem , Tirotropina Alfa/farmacologia , Idoso , Povo Asiático , Feminino , Humanos , Radioisótopos do Iodo , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório , Estudos Prospectivos , Cintilografia , Tireoglobulina/sangue , Tireoidectomia , Tirotropina Alfa/farmacocinética , Imagem Corporal Total
7.
Ann Nucl Med ; 21(10): 569-76, 2007 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-18092133

RESUMO

BACKGROUND: Quantitative myocardial fluorodeoxyglucose positron emission tomography (FDG-PET) for assessing glucose uptake in vivo is reliable in normal rat heart. OBJECTIVE: To assess the applicability of myocardial FDG-PET on multiple occasions in the longitudinal disease process of progressive hypertrophy of rat heart. METHODS: Six salt-sensitive Dahl rats (Dahl-S) developing progressive hypertrophy with subsequent dilated cardiomyopathy were compared with salt-resistant Dahl rats (controls). FDG-PET was applied twice at early stage (ES: 14-18 weeks) and at late stage (LS: 22-26 weeks) of hypertrophy. Standardized uptake value (SUV) was calculated for comparing between different animal weights and different injection dosages of FDG. For validating the quantitative study, radioactivity of a total of 36 tissue samples was compared with the corresponding PET values. RESULTS: The left ventricular mass in Dahl-S increased by 17% at ES and by 25% at LS. The SUV in Dahl-S was 95% of controls at ES and reduced to 62% at LS (P=0.023). The heart function started to deteriorate after LS. Linear regression analysis showed a good correlation between the radioactivity of tissue samples and PET values (Y=1.20X, P<0.0001, R2=0.979). CONCLUSIONS: Small animal PET studies on longitudinal multiple occasions in vivo were feasible and useful for the repeating assessment of glucose uptake. The reduction of glucose uptake in progressive hypertrophy of heart over time may precede its progression to heart failure.


Assuntos
Fluordesoxiglucose F18/farmacocinética , Coração/diagnóstico por imagem , Hipertrofia Ventricular Esquerda/diagnóstico por imagem , Hipertrofia Ventricular Esquerda/metabolismo , Miocárdio/metabolismo , Tomografia por Emissão de Pósitrons/métodos , Animais , Interpretação de Imagem Assistida por Computador/métodos , Taxa de Depuração Metabólica , Compostos Radiofarmacêuticos/farmacocinética , Ratos , Ratos Endogâmicos Dahl
8.
Nihon Rinsho ; 64(12): 2257-61, 2006 Dec.
Artigo em Japonês | MEDLINE | ID: mdl-17154088

RESUMO

Radioiodine treatment has been well established as an effective and safe therapeutic modality for Graves' disease. To promote more efficient use of this treatment in Japan, a working group has been organized in the Japan Thyroid Association and preparation of guidelines for its clinical use is under way. The treatment using upto 13.5 mCi of I-131 is feasible on out-patient basis. In comparison to the antithyroid drug treatment, the treatment has no side effects, brings in good control of hyperthyroidism and decrease the size of goiter. It is contraindicated in pregnant and lactating women. Patients treated should be carefully monitored for the possible worsening of ophthalmopathy and neonatal Graves' disease. Recent studies revealed the cost-effectiveness of the treatment. Its application to autonomously functioning thyroid nodules and toxic multinodular goiters is also discussed.


Assuntos
Doença de Graves/radioterapia , Radioisótopos do Iodo/uso terapêutico , Contraindicações , Análise Custo-Benefício , Feminino , Oftalmopatia de Graves/etiologia , Humanos , Recém-Nascido , Radioisótopos do Iodo/efeitos adversos , Radioisótopos do Iodo/economia , Japão , Guias de Prática Clínica como Assunto , Gravidez
9.
Eur J Radiol ; 55(1): 84-91, 2005 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-15950103

RESUMO

BACKGROUND AND PURPOSE: In patients with macroadenoma, posterior pituitary high signal (PPHS) on T1-weighted magnetic resonance (MR) imaging is sometimes observed in an ectopic location. The present study compared incidences of ectopic PPHS before and after macroadenoma surgery using MR imaging, including dynamic MR imaging to ascertain whether this ectopic change is irreversible. MATERIALS AND METHODS: MR imaging was performed preoperatively in 111 cases of macroadenoma, and then repeated more than 1-year postoperatively in 47 patients. Enhancement of PPHS was assessed using dynamic MR imaging. Areas of enhanced hyperintensity were considered true PPHS, and the relationship between presence and location of true PPHS and adenoma volume was analyzed. Moreover, changes in the presence and location of true PPHS were ascertained among the patients who underwent postoperative follow-up MR imaging. RESULTS: Preoperatively, PPHS was seen only in the normal location in 29 patients (Group A: 26.1%). High signal was detected only in an ectopic location in 58 patients, and early enhancement of this ectopic high signal was confirmed by dynamic MR imaging in 56 patients (Group B: 50.5%). No PPHS was observed in 24 patients (Group C: 21.6%). Adenoma volume was significantly greater for Group B than for Group A (p<0.001). Among the Group B patients who underwent MR imaging postoperatively (n=31), the location of PPHS was not changed, except for two patients in whom PPHS was absent. Postoperatively, PPHS was not observed in the normal location in any patient in the Group B. CONCLUSIONS: Greater volume of adenoma is associated with a higher incidence of ectopic PPHS, and the ectopic change is irreversible.


Assuntos
Adenoma/patologia , Imageamento por Ressonância Magnética/métodos , Neoplasias Hipofisárias/patologia , Adenoma/cirurgia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Análise de Variância , Meios de Contraste , Feminino , Gadolínio DTPA , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Neuro-Hipófise/patologia , Neoplasias Hipofisárias/cirurgia , Estudos Prospectivos
10.
Radiat Med ; 23(3): 182-8, 2005 May.
Artigo em Inglês | MEDLINE | ID: mdl-15940065

RESUMO

PURPOSE: To evaluate the pathologic significance of the low-attenuation changes of liver grafts in living donor partial liver transplantation (LDLT) on computed tomography (CT). MATERIALS AND METHODS: We retrospectively correlated the low-attenuation changes of liver grafts which were defined as readings below 50 HU on unenhanced CT with histological findings obtained by needle biopsy or surgery within seven days of CT studies. The study group included 35 CT findings of 35 recipients. We classified the low-attenuation change of the liver grafts into a homogeneous low-attenuation group and a heterogeneous low-attenuation group. RESULTS: Major histologic findings of 35 specimens included cholangitis in 10 (28.6%), cholestasis in eight (22.9%), fatty change in 15 (42.9%), acute cellular rejection (ACR) in 12 (34.3%), acute hepatitis in three (8.6%), liver cell ballooning in four (11.4%), massive hepatic necrosis in four (11.4%), and centrilobular congestion in five (14.3%) cases, respectively. Homogeneous and heterogeneous low-attenuation changes of liver grafts on unenhanced CT were seen in 26 (74.3%) and 9 (25.7%) cases, respectively. Massive hepatic necrosis occurred more frequently among the heterogeneous low-attenuation group than among the homogeneous low-attenuation group. CONCLUSION: Low-attenuation changes in liver grafts on CT may indicate a variety of pathological changes. Heterogeneous low-attenuation changes suggest massive hepatic necrosis.


Assuntos
Circulação Hepática , Transplante de Fígado , Fígado/diagnóstico por imagem , Fígado/patologia , Tomografia Computadorizada por Raios X , Adolescente , Adulto , Criança , Meios de Contraste , Feminino , Humanos , Iohexol , Doadores Vivos , Masculino , Necrose
11.
Radiology ; 235(3): 999-1004, 2005 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15833983

RESUMO

PURPOSE: To longitudinally and prospectively investigate changes in the volume and signal intensity on T1-weighted magnetic resonance (MR) images of the pituitary gland up to 1 year after delivery and evaluate whether termination of lactation has an effect on these parameters. MATERIALS AND METHODS: All participants provided informed consent for participation in the study, which was approved by the institutional review board. Thirteen volunteers (mean age, 28 years; age range, 26-32 years) underwent MR imaging 2 and 4 weeks after delivery and then at intervals of 0.5-2.0 months until 1 year after delivery. Eight participants terminated lactation during the study period. Sagittal and coronal T1-weighted images were obtained. Signal intensities of the anterior and posterior lobes of the pituitary were calculated relative to that of the pons. The volume of the pituitary was also calculated. Two-tailed paired Student t tests and separate simple linear regression analyses were used to test for statistically significant differences. RESULTS: The mean pituitary volume was 544 mm3 at 2 weeks, 523 mm3 at 4 months, 512 mm3 at 8 months, and 511 mm3 at 12 months after delivery, with significant differences between 2 weeks and 4 months (P = .002) and between 4 and 8 months (P = .003) after delivery. The mean ratio of the signal intensity of the anterior lobe of the pituitary to the signal intensity of the pons was 1.11 at 2 weeks, 1.07 at 4 months, 1.03 at 8 months, and 1.00 at 12 months after delivery, with significant differences between 2 weeks and 4 months (P = .004) and between 4 and 8 months (P = .0001) after delivery. Termination of lactation had no statistically significant effect on pituitary volume or the ratio of the signal intensity of the anterior or posterior lobe of the pituitary to the signal intensity of the pons. CONCLUSION: The volume of the pituitary gland decreases up to 8 months after delivery, and the T1-weighted signal intensity of the anterior lobe of the pituitary decreases; termination of lactation has no statistically significant effect on these parameters.


Assuntos
Parto Obstétrico , Imageamento por Ressonância Magnética , Hipófise/anatomia & histologia , Adulto , Feminino , Humanos , Estudos Longitudinais , Estudos Prospectivos , Fatores de Tempo
12.
Magn Reson Imaging ; 23(1): 89-95, 2005 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-15733793

RESUMO

The purpose of our study was to determine whether or not the addition of T2-weighted fast spin-echo (SE) imaging to gadolinium-enhanced spoiled gradient-recalled-echo (GRE) imaging improves the observer performance in the preoperative detection of malignant hepatic tumors. Gadolinium-enhanced GRE and fat-suppressed T2-weighted fast SE images obtained in 49 patients with 82 surgically confirmed malignant hepatic tumors (40 hepatocellular carcinomas and 42 metastases) were retrospectively reviewed by three independent off-site observers. In the random review of images, gadolinium-enhanced GRE images were reviewed first; thereafter, T2-weighted fast SE images were added for combined review. Observer performance was evaluated with the McNemar's test and receiver operating characteristic curve analysis. For gadolinium-enhanced GRE images alone vs. combined images, sensitivities for detection were 78% vs. 79% for hepatocellular carcinomas (P>.05), 67% vs. 71% for metastases (P<.05) and 72% vs. 75% for tumors overall (P<.05), respectively. The Az values were 0.892 vs. 0.889 in hepatocellular carcinomas (P>.05), 0.797 vs. 0.828 in metastases (P<.05) and 0.839 vs. 0.846 in tumors overall (P>.05), respectively. Our results showed that the addition of T2-weighted fast SE imaging to gadolinium-enhanced GRE imaging improved the observer performance in the detection of metastases.


Assuntos
Carcinoma Hepatocelular/diagnóstico , Neoplasias Hepáticas/diagnóstico , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma Hepatocelular/cirurgia , Meios de Contraste , Feminino , Gadolínio DTPA , Hepatectomia , Humanos , Neoplasias Hepáticas/cirurgia , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Cuidados Pré-Operatórios , Curva ROC , Estudos Retrospectivos , Sensibilidade e Especificidade
13.
Radiology ; 234(2): 381-90, 2005 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-15670995

RESUMO

PURPOSE: To evaluate accuracy of cardiac functional analysis with multi-detector row computed tomography (CT) and segmental reconstruction algorithm over a range of heart rates. MATERIALS AND METHODS: Institutional review board approval was obtained. Informed consent was not required. Multi-detector row CT (500-msec rotation time, 8 x 1-mm detector collimation) and magnetic resonance (MR) imaging were performed in 50 patients (28 men, 22 women; age range, 46-84 years; mean age, 67 years). Two-dimensional echocardiography was performed in 41 patients, and electrocardiographically (ECG)-gated single photon emission computed tomography (SPECT) was performed in 27. End-diastolic volume (EDV), end-systolic volume (ESV), ejection fraction (EF), and left ventricular (LV) mass were estimated with multi-detector row CT and compared with values estimated with MR imaging, which served as the reference standard. Additionally, EF values estimated with multi-detector row CT, echocardiography, and SPECT were compared with those estimated with MR imaging. Systemic error and degree of agreement of global functional parameters measured with MR imaging and other modalities were assessed. In a second analysis, linear regression analysis was added. RESULTS: EF estimated with multi-detector row CT agreed and correlated well with EF estimated with MR imaging (bias +/- standard deviation, -1.2% +/- 4.6; r = 0.96). Agreement and correlation were similar for EDV (-0.35 mL +/- 15.2; r = 0.97), ESV (1.1 mL +/- 8.6; r = 0.99), and LV mass (2.5 mL +/- 15.0; r = 0.96). Standard deviation of EF difference between multi-detector row CT and MR imaging was significantly less than that between echocardiography and MR imaging (P < .001) or that between SPECT and MR imaging (P < .001). CONCLUSION: Various LV functional parameters were measured with multi-detector row CT with a segmental approach, and measurements correlated and agreed with those obtained with MR imaging. Moreover, functional analysis with multi-detector row CT was more accurate than that with two-dimensional echocardiography or ECG-gated SPECT.


Assuntos
Algoritmos , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Ecocardiografia , Feminino , Frequência Cardíaca/fisiologia , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Volume Sistólico , Tomografia Computadorizada de Emissão de Fóton Único
14.
J Comput Assist Tomogr ; 28(6): 849-51, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15538163

RESUMO

Delayed contrast-enhanced magnetic resonance (MR) imaging that nullifies the signal of normal myocardium produces great differences in myocardial signal intensity between normal and infarcted myocardium. A case of primary cardiac lymphoma is presented in which delayed contrast-enhanced MR imaging clearly identified the localization and extension of a lymphoma infiltrating the myocardium.


Assuntos
Meios de Contraste , Neoplasias Cardíacas/diagnóstico , Aumento da Imagem/métodos , Linfoma/diagnóstico , Imageamento por Ressonância Magnética/métodos , Eletrocardiografia , Feminino , Gadolínio DTPA , Átrios do Coração/patologia , Ventrículos do Coração/patologia , Humanos , Pessoa de Meia-Idade , Invasividade Neoplásica
15.
Ann Nucl Med ; 18(4): 337-44, 2004 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15359928

RESUMO

Recently, 5-[123I]iodo-3-(2(S)-azetidinylmethoxy)pyridine ([123I]5IA) was developed as a ligand for imaging the nicotinic acetylcholine receptor (nAChR) in human brain using single photon emission computed tomography (SPECT). In the present study, the toxicity and radiation absorbed dose of [123I]5IA were investigated. Behavior and physiological parameters were examined in mice and rats after administration of 5IA. There were no changes in these parameters in animals administered 1 microg/kg of 5IA or less, indicating that the no observed effect level (NOEL) of 5IA was 1 microg/kg. [123I]5IA was then administered to healthy human subjects and serial whole-body images were acquired over 24 hr. Initially, high levels of radioactivity were observed in the liver and urinary bladder and moderate levels in the lungs, kidneys, and brain. Whole brain activity at 1 hr was 4.6 +/- 0.4% of the injected dose and this value gradually decreased with time. The majority (-75%) of the radioactivity was excreted in urine within 24 hr, and less than 1% remained in all organs tested. The biological half-life of [1231]51A averaged 7.2 +/- 4.0 hr. Based on the biodistribution data, radiation absorbed doses were estimated using MIRDOSE 3.1 software with the dynamic bladder model and the ICRP gastrointestinal (GI) tract model. Consequently, the effective dose equivalent was estimated to be 30 +/- 1.4 microSv/MBq, which is an acceptable radiation burden. Having determined the safety of this compound, we performed SPECT imaging in a healthy human subject using 171 MBq of [123I]5IA. SPECT images clearly revealed a cerebral distribution of radioactivity that was consistent with the known distribution of central nAChRs in humans. These results suggest that [123I]5IA is a promising ligand for imaging nAChRs in humans, with an acceptable dosimetry and pharmacological safety at the dose required for adequate SPECT imaging.


Assuntos
Azetidinas/farmacocinética , Encéfalo/diagnóstico por imagem , Encéfalo/metabolismo , Piridinas/farmacocinética , Radiometria/métodos , Receptores Nicotínicos/metabolismo , Adulto , Idoso , Animais , Azetidinas/efeitos adversos , Carga Corporal (Radioterapia) , Humanos , Masculino , Taxa de Depuração Metabólica , Camundongos , Camundongos Endogâmicos ICR , Especificidade de Órgãos , Piridinas/efeitos adversos , Doses de Radiação , Lesões por Radiação/diagnóstico por imagem , Lesões por Radiação/etiologia , Lesões por Radiação/metabolismo , Cintilografia , Compostos Radiofarmacêuticos/efeitos adversos , Compostos Radiofarmacêuticos/farmacocinética , Ratos , Ratos Sprague-Dawley , Eficiência Biológica Relativa , Especificidade da Espécie , Distribuição Tecidual , Contagem Corporal Total
16.
Eur J Radiol ; 51(3): 209-17, 2004 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-15294327

RESUMO

OBJECTIVE: To evaluate the cavernous sinuses with dynamic magnetic resonance (MR) imaging in patients with Tolosa-Hunt syndrome (THS). METHODS: The sellar and parasellar regions of five patients with THS and 12 control subjects were examined with dynamic MR (1.5 T) imaging in the coronal plane. Dynamic images were obtained with spin-echo (SE) sequences in three patients, and with fast spin-echo (FSE) sequences in two patients and control subjects. Conventional MR images of the cranium including sellar and parasellar regions were also obtained on T1-weighted pre- and post-contrast SE, and T2-weighted FSE sequences in the coronal plane. RESULTS: MR images revealed affected cavernous sinus with bulged convex lateral wall in three patients and concave lateral wall in two patients. In all control subjects, cavernous sinuses were observed with concave lateral wall. The signal intensity on T1- and T2-weighted images and contrast enhancement on post-contrast images of the affected cavernous sinuses in patients were similar to those of the unaffected cavernous sinuses in patients and control subjects. The dynamic images in all patients disclosed small areas adjacent to the cranial nerve filling-defects within the enhanced venous spaces of the affected cavernous sinus, which showed slow and gradual enhancement from the early to the late dynamic images. No such gradually enhancing area was observed in control subjects except one. The follow-up dynamic MR images after corticosteroid therapy revealed complete resolution of the gradually enhancing areas in the previously affected cavernous sinus. CONCLUSION: Dynamic MR imaging may facilitate the diagnosis of THS.


Assuntos
Imageamento por Ressonância Magnética/métodos , Síndrome de Tolosa-Hunt/diagnóstico , Adulto , Anti-Inflamatórios/uso terapêutico , Estudos de Casos e Controles , Seio Cavernoso/efeitos dos fármacos , Seio Cavernoso/patologia , Meios de Contraste/administração & dosagem , Feminino , Seguimentos , Gadolínio DTPA/administração & dosagem , Glucocorticoides/uso terapêutico , Humanos , Aumento da Imagem/métodos , Injeções Intravenosas , Masculino , Metilprednisolona/uso terapêutico , Hipófise/patologia , Prednisolona/uso terapêutico , Estudos Prospectivos , Síndrome de Tolosa-Hunt/tratamento farmacológico
17.
Nucl Med Biol ; 31(6): 811-4, 2004 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-15246373

RESUMO

Since a very complicated technique is necessary to measure cerebral blood flow (CBF) with [14C]iodoantipyrine in small animals, a practical and easy method is needed. In this paper, the differential uptake ratio (DUR) at 5 min after injection of N-isopropyl-p-[125I]iodoamphetamine (IMP) was estimated as an index of CBF in normal rats and compared with the quantitative CBF value measured using [15O]H2O and dynamic PET scan. A good correlation between the two values was obtained. The results indicate that DUR of [125I]IMP at 5 min after injection in rats is a useful and practical indicator of CBF since neither arterial blood sampling nor metabolite correction is necessary.


Assuntos
Circulação Cerebrovascular/efeitos dos fármacos , Iofetamina , Compostos Radiofarmacêuticos , Algoritmos , Animais , Autorradiografia , Água Corporal , Masculino , Microesferas , Tomografia por Emissão de Pósitrons , Ratos , Ratos Wistar
18.
Ann Nucl Med ; 18(2): 105-14, 2004 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15195757

RESUMO

PURPOSE: To evaluate the appropriate post-injection timing for hand-held-gamma-ray-detecting probe (GDP) scanning for the intraoperative detection of malignancy after preoperative F-18 FDG (FDG) injection. METHODS: Patient study with superficially located cancer was performed on three patients before operation by dual-phase whole-body PET at 2 and 6-7 hr post-injection of FDG (370 MBq), and by probe scanning from the skin at several points at 1, 3, 5, and 7 hr after FDG injection. TNRa (tumor-adjacent-normal ratio) and TNRc (tumor-contralateral-normal ratio) were calculated. Phantom study was also performed to determine basic GDP function. RESULTS: The patient study revealed that tumors showed constant TNRa (0.9-1.3) and TNRc (1.1-3.0) by GDP count rate, and that there was no tendency of an increase in TNRa with time. The standard deviations of GDP count rate were lower at 1-3 hr post-injection compared with those of delayed scans. While delayed PET showed an increase or no change in the tumor FDG uptake, the decrease of normal tissue FDG uptake was not adequate to create higher TNRs. The phantom study revealed that LN model showed TNRa of 1.7 or greater by GDP count rate (cps) when background contained no FDG, but that they showed TNRa of 1.3 or less when the background contained 4% of the LN FDG activity per ml. CONCLUSION: The present study suggests that higher FDG count rate of tumors at 1-3 hr postinjection would be more suitable for the gamma-probe detection compared with lower count rate at 6-7 hr delayed scans with wide standard deviations.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Fluordesoxiglucose F18/administração & dosagem , Aumento da Imagem/métodos , Tomografia por Emissão de Pósitrons/métodos , Neoplasias Gástricas/diagnóstico por imagem , Cirurgia Assistida por Computador/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Câmaras gama , Humanos , Injeções Intravenosas/métodos , Cuidados Intraoperatórios/métodos , Pessoa de Meia-Idade , Imagens de Fantasmas , Projetos Piloto , Tomografia por Emissão de Pósitrons/instrumentação , Cuidados Pré-Operatórios/métodos , Compostos Radiofarmacêuticos/farmacocinética , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Fatores de Tempo
19.
J Nucl Med ; 45(5): 730-8, 2004 May.
Artigo em Inglês | MEDLINE | ID: mdl-15136619

RESUMO

UNLABELLED: The aims of this study were (a). to compare absolute myocardial blood flow (MBF) during adenosine triphosphate (ATP) infusion with that after dipyridamole administration without caffeine intake and (b). to evaluate the effect of caffeine intake on the hyperemic flow induced by these coronary vasodilator agents. METHODS: MBF was quantified with (15)O-labeled water and PET at rest, during ATP infusion (0.16 mg/kg/min for 9 min), and after dipyridamole administration (0.56 mg/kg over 4 min) after a 24-h abstinence from caffeine (baseline evaluation) in 10 healthy volunteers. Within 2 wk, the same PET studies were repeated after caffeine intake to evaluate the effect of caffeine on the hyperemic flow induced by these pharmacologic agents (caffeine study). Myocardial flow reserve (MFR), defined as the ratio of hyperemic to resting blood flow, was also evaluated. RESULTS: Resting MBF in baseline and caffeine studies did not differ significantly (0.79 +/- 0.29 vs. 0.75 +/- 0.31 mL/min/g, P = 0.88). Without caffeine intake, MBF during ATP infusion was significantly higher than that after dipyridamole administration (3.70 +/- 0.67 vs. 3.00 +/- 0.79 mL/min/g, P = 0.003), whereas there was no significant difference in MFR between ATP and dipyridamole stress (5.15 +/- 1.64 vs. 4.11 +/- 1.44, P = 0.07). After caffeine intake, the hyperemic flows induced by ATP and dipyridamole were not significantly different (1.68 +/- 0.37 vs. 1.52 +/- 0.40 mL/min/g, P = 0.50). MFR estimated by ATP and dipyridamole also did not differ significantly in the caffeine studies (2.44 +/- 0.88 vs. 2.25 +/- 0.94, P = 0.73). MBF during ATP infusion and after dipyridamole administration were significantly lower in the caffeine studies than that in the baseline evaluation (1.68 +/- 0.37 vs. 3.70 +/- 0.67 mL/min/g, P < 0.0001, and 1.52 +/- 0.40 vs. 3.00 +/- 0.79 mL/min/g, P < 0.0001, respectively). CONCLUSION: This study demonstrates that ATP has the potential to induce greater hyperemia than dipyridamole, whereas hyperemic responses to ATP and dipyridamole are similarly attenuated after caffeine intake. These findings suggest that abstinence from caffeine before ATP stress testing may be needed.


Assuntos
Trifosfato de Adenosina/farmacologia , Cafeína/farmacologia , Circulação Coronária/efeitos dos fármacos , Dipiridamol/farmacologia , Coração/diagnóstico por imagem , Hiperemia/induzido quimicamente , Tomografia Computadorizada de Emissão , Vasodilatadores/farmacologia , Adulto , Hemodinâmica/efeitos dos fármacos , Humanos , Infusões Intravenosas , Masculino , Radioisótopos de Oxigênio , Água
20.
Eur J Nucl Med Mol Imaging ; 31(9): 1299-303, 2004 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-15168088

RESUMO

PURPOSE: Although various radiopharmaceuticals have been developed for the detection of atheromas, external imaging techniques have limitations when it comes to the detection of small plaques. In this study, we developed a charged particle-sensitive detector for the endovascular detection of small plaques. METHODS: The device consists of a probe, an automatic pullback unit and a controller. The probe, which consists of a plastic scintillator and flexible optical fibres, is 1.0 mm in diameter. The probe was inserted into a catheter placed on (18)F point sources, and then the radioactivity was measured as the probe was pulled out stepwise. RESULTS: The sensitivity for (18)F was 9.3 cps/kBq, and there was a close linear correlation between the peak counts and source dose until at least 0.8 MBq. Furthermore, this device showed low background counts (<0.1 cps) and a low detection limit (0.21 kBq). To investigate the effect of background radioactivity on the measurement at the point sources, a ball phantom was prepared and five (18)F point sources were set on the ball's surface. Even though 298 MBq of (18)F-fluorodeoxyglucose was injected into the ball, the point sources located every 10 mm on the ball's surface were detectable separately. CONCLUSION: The data gathered suggest that a catheter-based radiation detector in combination with charged particle-emitting radiopharmaceuticals is useful for the endovascular detection of small lesions such as coronary plaques.


Assuntos
Cateterismo/instrumentação , Doença da Artéria Coronariana/diagnóstico por imagem , Fluordesoxiglucose F18 , Contagem de Cintilação/instrumentação , Animais , Estenose das Carótidas/diagnóstico por imagem , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Imagens de Fantasmas , Doses de Radiação , Radiometria/instrumentação , Radiometria/métodos , Cintilografia , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Contagem de Cintilação/métodos , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...