Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 124
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Phys Chem Lett ; : 5382-5389, 2024 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-38738984

RESUMO

Metronidazole is a prospective hyperpolarized MRI contrast agent with potential hypoxia sensing utility for applications in cancer, stroke, neurodegenerative diseases, etc. We demonstrate a pilot procedure for production of ∼30 mM hyperpolarized [15N3]metronidazole in aqueous media by using a phase-separated SABRE-SHEATH hyperpolarization method, with nitrogen-15 polarization exceeding 2.2% on all three 15N sites achieved in less than 2 min. The 15N polarization T1 of ∼12 min is reported for the 15NO2 group at the clinically relevant field of 1.4 T in the aqueous phase, demonstrating a remarkably long lifetime of the hyperpolarized state. The produced aqueous solution of [15N3]metronidazole that contained only ∼100 µM of residual Ir was deemed biocompatible via validation through the MTT colorimetric test for assessing cell metabolic activity using human embryotic kidney HEK293T cells. This low-cost and ultrafast hyperpolarization procedure represents a major advance for the production of a biocompatible HP [15N3]metronidazole (and potentially other hyperpolarized drugs) formulation for MRI sensing applications.

2.
Angew Chem Int Ed Engl ; 63(22): e202402877, 2024 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-38523072

RESUMO

Hyperpolarization techniques provide a dramatic increase in sensitivity of nuclear magnetic resonance spectroscopy and imaging. In spite of the outstanding progress in solution-state hyperpolarization of spin-1/2 nuclei, hyperpolarization of quadrupolar nuclei remains challenging. Here, hyperpolarization of quadrupolar 14N nuclei with natural isotopic abundance of >99 % is demonstrated. This is achieved via pairwise addition of parahydrogen to tetraalkylammonium salts with vinyl or allyl unsaturated moieties followed by a subsequent polarization transfer from 1H to 14N nuclei at high magnetic field using PH-INEPT or PH-INEPT+ radiofrequency pulse sequence. Catalyst screening identified water-soluble rhodium complex [Rh(P(m-C6H4SO3Na)3)3Cl] as the most efficient catalyst for hyperpolarization of the substrates under study, providing up to 1.3 % and up to 6.6 % 1H polarization in the cases of vinyl and allyl precursors, respectively. The performance of PH-INEPT and PH-INEPT+ pulse sequences was optimized with respect to interpulse delays, and the resultant experimental dependences were in good agreement with simulations. As a result, 14N NMR signal enhancement of up to 760-fold at 7.05 T (corresponding to 0.15 % 14N polarization) was obtained.

3.
Chemistry ; 30(25): e202304071, 2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38381807

RESUMO

Hyperpolarized 129Xe gas was FDA-approved as an inhalable contrast agent for magnetic resonance imaging of a wide range of pulmonary diseases in December 2022. Despite the remarkable success in clinical research settings, the widespread clinical translation of HP 129Xe gas faces two critical challenges: the high cost of the relatively low-throughput hyperpolarization equipment and the lack of 129Xe imaging capability on clinical MRI scanners, which have narrow-bandwidth electronics designed only for proton (1H) imaging. To solve this translational grand challenge of gaseous hyperpolarized MRI contrast agents, here we demonstrate the utility of batch-mode production of proton-hyperpolarized diethyl ether gas via heterogeneous pairwise addition of parahydrogen to ethyl vinyl ether. An approximately 0.1-liter bolus of hyperpolarized diethyl ether gas was produced in 1 second and injected in excised rabbit lungs. Lung ventilation imaging was performed using sub-second 2D MRI with up to 2×2 mm2 in-plane resolution using a clinical 0.35 T MRI scanner without any modifications. This feasibility demonstration paves the way for the use of inhalable diethyl ether as a gaseous contrast agent for pulmonary MRI applications using any clinical MRI scanner.


Assuntos
Meios de Contraste , Pulmão , Imageamento por Ressonância Magnética , Isótopos de Xenônio , Meios de Contraste/química , Imageamento por Ressonância Magnética/métodos , Animais , Pulmão/diagnóstico por imagem , Coelhos , Isótopos de Xenônio/química , Gases/química , Éter/química
4.
J Magn Reson ; 360: 107648, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38401476

RESUMO

In this work we achieve a significant overpopulation (PLLS≈1%) of the long-lived spin state (LLS) of methylene protons in 2-bromoethan(2H)ol (BrEtOD) obtained in a reaction between ethylene with non-equilibrium nuclear spin order and bromine water. Given all protons in ethylene are magnetically equivalent, its nuclear states are classified into nuclear spin isomers (NSIM) with total spin I = 2,1,0. Addition of parahydrogen to acetylene produces ethylene with a population of only those NSIMs with I = 1,0. As a result of the reaction with bromine water the non-equilibrium spin order of ethylene is partly transferred to the singlet LLS involving the two methylene groups of BrEtOD. The 1H NMR signal enhancement (SE≈200) obtained as a result of the LLS readout is approximately equal to the SE of the hyperpolarized BrEtOD obtained with a single π/4 pulse. The LLS relaxation time (TLLS) was shown to be approximately 40 s (≈8T1) in the argon-bubbled sample.

5.
Anal Chem ; 96(10): 4171-4179, 2024 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-38358916

RESUMO

We present an integrated, open-source device for parahydrogen-based hyperpolarization processes in the microtesla field regime with a cost of components of less than $7000. The device is designed to produce a batch of 13C and 15N hyperpolarized (HP) compounds via hydrogenative or non-hydrogenative parahydrogen-induced polarization methods that employ microtesla magnetic fields for efficient polarization transfer of parahydrogen-derived spin order to X-nuclei (e.g., 13C and 15N). The apparatus employs a layered structure (reminiscent of a Russian doll "Matryoshka") that includes a nonmagnetic variable-temperature sample chamber, a microtesla magnetic field coil (operating in the range of 0.02-75 microtesla), a three-layered mu-metal shield (to attenuate the ambient magnetic field), and a magnetic shield degaussing coil placed in the overall device enclosure. The gas-handling manifold allows for parahydrogen-gas flow and pressure control (up to 9.2 bar of total parahydrogen pressure). The sample temperature can be varied either using a water bath or a PID-controlled heat exchanger in the range from -12 to 80 °C. This benchtop device measures 62 cm (length) × 47 cm (width) × 47 cm (height), weighs 30 kg, and requires only connections to a high-pressure parahydrogen gas supply and a single 110/220 VAC power source. The utility of the device has been demonstrated using an example of parahydrogen pairwise addition to form HP ethyl [1-13C]acetate (P13C = 7%, [c] = 1 M). Moreover, the Signal Amplification By Reversible Exchange in SHield Enables Alignment Transfer to Heteronuclei (SABRE-SHEATH) technique was employed to demonstrate efficient hyperpolarization of 13C and 15N spins in a wide range of biologically relevant molecules, including [1-13C]pyruvate (P13C = 14%, [c] = 27 mM), [1-13C]-α-ketoglutarate (P13C = 17%), [1-13C]ketoisocaproate (P13C = 18%), [15N3]metronidazole (P15N = 13%, [c] = 20 mM), and others. While the vast majority of the utility studies have been performed in standard 5 mm NMR tubes, the sample chamber of the device can accommodate a wide range of sample container sizes and geometries of up to 1 L sample volume. The device establishes an integrated, simple, inexpensive, and versatile equipment gateway needed to facilitate parahydrogen-based hyperpolarization experiments ranging from basic science to preclinical applications; indeed, detailed technical drawings and a bill of materials are provided to support the ready translation of this design to other laboratories.

6.
Phys Chem Chem Phys ; 26(9): 7821-7829, 2024 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-38375632

RESUMO

Symmetric molecules exist as distinct nuclear spin isomers (NSIMs). A deeper understanding of their properties, including interconversion of different NSIMs, requires efficient techniques for NSIM enrichment. In this work, selective hydrogenation of acetylene with parahydrogen (p-H2) was used to achieve the enrichment of ethylene NSIMs and to study their equilibration processes. The effect of the stereoselectivity of H2 addition to acetylene on the imbalance of ethylene NSIMs was experimentally demonstrated by using three different heterogeneous catalysts (an immobilized Ir complex and two supported Pd catalysts). The interconversion of NSIMs with time during ethylene storage was studied using NMR spectroscopy by reacting ethylene with bromine water, which rendered the p-H2-derived protons in the produced 2-bromoethan(2H)ol (BrEtOD) magnetically inequivalent, thereby revealing the non-equilibrium nuclear spin order of ethylene. A thorough analysis of the shape and transformation of the 1H NMR spectra of hyperpolarized BrEtOD allowed us to reveal the initial distribution of produced ethylene NSIMs and their equilibration processes. Comparison of the results obtained with three different catalysts was key to properly attributing the derived characteristic time constants to different ethylene NSIM interconversion processes: ∼3-6 s for interconversion between NSIMs with the same inversion symmetry (i.e., within g or u manifolds) and ∼1700-2200 s between NSIMs with different inversion symmetries (i.e., between g and u manifolds).

7.
ACS Sens ; 9(2): 770-780, 2024 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-38198709

RESUMO

13C hyperpolarized pyruvate is an emerging MRI contrast agent for sensing molecular events in cancer and other diseases with aberrant metabolic pathways. This metabolic contrast agent can be produced via several hyperpolarization techniques. Despite remarkable success in research settings, widespread clinical adoption faces substantial roadblocks because the current sensing technology utilized to sense this contrast agent requires the excitation of 13C nuclear spins that also need to be synchronized with MRI field gradient pulses. Here, we demonstrate sensing of hyperpolarized allyl [1-13C]pyruvate via the stimulated emission of radiation that mitigates the requirements currently blocking broader adoption. Specifically, 13C Radiofrequency Amplification by Stimulated Emission of Radiation (13C RASER) was obtained after pairwise addition of parahydrogen to a pyruvate precursor, detected in a commercial inductive detector with a quality factor (Q) of 32 for sample concentrations as low as 0.125 M with 13C polarization of 4%. Moreover, parahydrogen-induced polarization allowed for the preparation of a mixture of ketone and hemiketal forms of hyperpolarized allyl [1-13C]pyruvate, which are separated by 10 ppm in 13C NMR spectra. This is a good model system to study the simultaneous 13C RASER signals of multiple 13C species. This system models the metabolic production of hyperpolarized [1-13C]lactate from hyperpolarized [1-13C]pyruvate, which has a similar chemical shift difference. Our results show that 13C RASER signals can be obtained from both species simultaneously when the emission threshold is exceeded for both species. On the other hand, when the emission threshold is exceeded only for one of the hyperpolarized species, 13C stimulated emission is confined to this species only, therefore enabling the background-free detection of individual hyperpolarized 13C signals. The reported results pave the way to novel sensing approaches of 13C hyperpolarized pyruvate, potentially unlocking hyperpolarized 13C MRI on virtually any MRI system─an attractive vision for the future molecular imaging and diagnostics.


Assuntos
Isótopos de Carbono , Meios de Contraste , Ácido Pirúvico , Ácido Pirúvico/metabolismo , Espectroscopia de Ressonância Magnética/métodos , Ácido Láctico
8.
Int J Mol Sci ; 24(21)2023 Oct 27.
Artigo em Inglês | MEDLINE | ID: mdl-37958626

RESUMO

Immobilized [Ir(COD)Cl]2-Linker/TiO2 catalysts with linkers containing Py, P(Ph)2 and N(CH3)2 functional groups were prepared. The catalysts were tested via propene hydrogenation with parahydrogen in a temperature range from 40 °C to 120 °C which was monitored via NMR. The catalytic behavior of [Ir(COD)Cl]2-Linker/TiO2 is explained on the basis of quantitative and qualitative XPS data analysis performed for the catalysts before and after the reaction at 120 °C. It is shown that the temperature dependence of propene conversion and the enhancement of the NMR signal are explained via a combination of the stabilities of both the linker and immobilized [Ir(COD)Cl]2 complex. It is demonstrated that the N(CH3)2-linker is the most stable at the surface of TiO2 under used reaction conditions. As a result, only this sample shows a rise in the enhancement of the NMR signal in the 100-120 °C temperature range.


Assuntos
Alcenos , Titânio , Hidrogenação , Titânio/química
9.
ACS Sens ; 8(10): 3845-3854, 2023 10 27.
Artigo em Inglês | MEDLINE | ID: mdl-37772716

RESUMO

Hyperpolarized magnetic resonance imaging (MRI) contrast agents are revolutionizing the field of biomedical imaging. Hyperpolarized Xe-129 was recently FDA approved as an inhalable MRI contrast agent for functional lung imaging sensing. Despite success in research settings, modern Xe-129 hyperpolarizers are expensive (up to $1M), large, and complex to site and operate. Moreover, Xe-129 sensing requires specialized MRI hardware that is not commonly available on clinical MRI scanners. Here, we demonstrate that proton-hyperpolarized propane gas can be produced on demand using a disposable, hand-held, clinical-scale hyperpolarizer via parahydrogen-induced polarization, which relies on parahydrogen as a source of hyperpolarization. The device consists of a heterogeneous catalytic reactor connected to a gas mixture storage can containing pressurized hyperpolarization precursors: propylene and parahydrogen (10 bar total pressure). Once the built-in flow valve of the storage can is actuated, the precursors are ejected from the can into a reactor, and a stream of hyperpolarized propane gas is ejected from the reactor. Robust operation of the device is demonstrated for producing proton sensing polarization of 1.2% in a wide range of operational pressures and gas flow rates. We demonstrate that the propylene/parahydrogen gas mixture can retain potency for days in the storage can with a monoexponential decay time constant of 6.0 ± 0.5 days, which is limited by the lifetime of the parahydrogen singlet spin state in the storage container. The utility of the produced sensing agent is demonstrated for phantom imaging on a 3 T clinical MRI scanner located 100 miles from the agent/device preparation site and also for ventilation imaging of excised pig lungs using a 0.35 T clinical MRI scanner. The cost of the device components is less than $35, which we envision can be reduced to less than $5 for mass-scale production. The hyperpolarizer device can be reused, recycled, or disposed.


Assuntos
Propano , Prótons , Animais , Suínos , Espectroscopia de Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/métodos , Gases , Meios de Contraste , Pulmão/diagnóstico por imagem
10.
Chem Commun (Camb) ; 59(62): 9509-9512, 2023 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-37450281

RESUMO

We show that catalyst-free aqueous solutions of hyperpolarized [1-13C]succinate can be produced using parahydrogen-induced polarization (PHIP) and a combination of homogeneous and heterogeneous catalytic hydrogenation reactions. We generate hyperpolarized [1-13C]fumarate via PHIP using para-enriched hydrogen gas with a homogeneous ruthenium catalyst, and subsequently remove the toxic catalyst and reaction side products via a purification procedure. Following this, we perform a second hydrogenation reaction using normal hydrogen gas to convert the fumarate into succinate using a solid Pd/Al2O3 catalyst. This inexpensive polarization protocol has a turnover time of a few minutes, and represents a major advance for in vivo applications of [1-13C]succinate as a hyperpolarized contrast agent.

11.
Molecules ; 28(3)2023 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-36770865

RESUMO

The present work investigates the potential for enhancing the NMR signals of DNA nucleobases by parahydrogen-based hyperpolarization. Signal amplification by reversible exchange (SABRE) and SABRE in Shield Enables Alignment Transfer to Heteronuclei (SABRE-SHEATH) of selected DNA nucleobases is demonstrated with the enhancement (ε) of 1H, 15N, and/or 13C spins in 3-methyladenine, cytosine, and 6-O-guanine. Solutions of the standard SABRE homogenous catalyst Ir(1,5-cyclooctadeine)(1,3-bis(2,4,6-trimethylphenyl)imidazolium)Cl ("IrIMes") and a given nucleobase in deuterated ethanol/water solutions yielded low 1H ε values (≤10), likely reflecting weak catalyst binding. However, we achieved natural-abundance enhancement of 15N signals for 3-methyladenine of ~3300 and ~1900 for the imidazole ring nitrogen atoms. 1H and 15N 3-methyladenine studies revealed that methylation of adenine affords preferential binding of the imidazole ring over the pyrimidine ring. Interestingly, signal enhancements (ε~240) of both 15N atoms for doubly labelled cytosine reveal the preferential binding of specific tautomer(s), thus giving insight into the matching of polarization-transfer and tautomerization time scales. 13C enhancements of up to nearly 50-fold were also obtained for this cytosine isotopomer. These efforts may enable the future investigation of processes underlying cellular function and/or dysfunction, including how DNA nucleobase tautomerization influences mismatching in base-pairing.


Assuntos
Imidazóis , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Isótopos de Nitrogênio/química , DNA
12.
Chem Rev ; 123(4): 1417-1551, 2023 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-36701528

RESUMO

Magnetic resonance techniques are successfully utilized in a broad range of scientific disciplines and in various practical applications, with medical magnetic resonance imaging being the most widely known example. Currently, both fundamental and applied magnetic resonance are enjoying a major boost owing to the rapidly developing field of spin hyperpolarization. Hyperpolarization techniques are able to enhance signal intensities in magnetic resonance by several orders of magnitude, and thus to largely overcome its major disadvantage of relatively low sensitivity. This provides new impetus for existing applications of magnetic resonance and opens the gates to exciting new possibilities. In this review, we provide a unified picture of the many methods and techniques that fall under the umbrella term "hyperpolarization" but are currently seldom perceived as integral parts of the same field. Specifically, before delving into the individual techniques, we provide a detailed analysis of the underlying principles of spin hyperpolarization. We attempt to uncover and classify the origins of hyperpolarization, to establish its sources and the specific mechanisms that enable the flow of polarization from a source to the target spins. We then give a more detailed analysis of individual hyperpolarization techniques: the mechanisms by which they work, fundamental and technical requirements, characteristic applications, unresolved issues, and possible future directions. We are seeing a continuous growth of activity in the field of spin hyperpolarization, and we expect the field to flourish as new and improved hyperpolarization techniques are implemented. Some key areas for development are in prolonging polarization lifetimes, making hyperpolarization techniques more generally applicable to chemical/biological systems, reducing the technical and equipment requirements, and creating more efficient excitation and detection schemes. We hope this review will facilitate the sharing of knowledge between subfields within the broad topic of hyperpolarization, to help overcome existing challenges in magnetic resonance and enable novel applications.

13.
Anal Chem ; 94(43): 15010-15017, 2022 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-36264746

RESUMO

Hyperpolarized (i.e., polarized far beyond the thermal equilibrium) nuclear spins can result in the radiofrequency amplification by stimulated emission of radiation (RASER) effect. Here, we show the utility of RASER to amplify nuclear magnetic resonance (NMR) signals of solute and solvent molecules in the liquid state. Specifically, parahydrogen-induced RASER was used to spontaneously enhance nuclear spin polarization of protons and heteronuclei (here 19F and 31P) in a wide range of molecules. The magnitude of the effect correlates with the T1 relaxation time of the target nuclear spins. A series of control experiments validate the through-space dipolar mechanism of the RASER-assisted polarization transfer between the parahydrogen-polarized compound and to-be-hyperpolarized nuclei of the target molecule. Frequency-selective saturation of the RASER-active resonances was used to control the RASER and the amplitude of spontaneous polarization transfer. Spin dynamics simulations support our experimental RASER studies. The enhanced NMR sensitivity may benefit various NMR applications such as mixture analysis, metabolomics, and structure determination.


Assuntos
Imageamento por Ressonância Magnética , Ondas de Rádio , Espectroscopia de Ressonância Magnética , Prótons , Soluções
14.
J Phys Chem Lett ; 13(44): 10253-10260, 2022 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-36301252

RESUMO

Magnetic resonance imaging (MRI) provides unique information about the internal structure and function of living organisms in a non-invasive way. The use of conventional proton MRI for the observation of real-time metabolism is hampered by the dominant signals of water and fat, which are abundant in living organisms. Heteronuclear MRI in conjunction with the hyperpolarization methods does not encounter this issue. In this work, we polarized 15N nuclei of [15N1]fampridine (a drug used for the treatment of multiple sclerosis) to the level of 4% in nuclear magnetic resonance (NMR) experiments and 0.7% in MRI studies using spin-lock-induced crossing combined with signal amplification by reversible exchange. Consequently, three-dimensional 15N MRI of the hyperpolarized 15N-labeled drug was acquired in 0.1 s with a signal-to-noise ratio of 70. In addition, the NMR signal enhancements for 15N-enriched fampridine and fampridine with a natural abundance of 15N nuclei were compared and an explanation for their difference was proposed.


Assuntos
Imageamento por Ressonância Magnética , Prótons , Espectroscopia de Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/métodos , Isótopos de Nitrogênio/química
15.
Phys Chem Chem Phys ; 24(10): 5956-5964, 2022 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-35195621

RESUMO

Typical magnetic resonance experiments are routinely limited by weak signal responses. In some cases, the low intrinsic sensitivity can be alleviated by the implementation of hyperpolarization technologies. Dissolution-dynamic nuclear polarization offers a means of hyperpolarizing small molecules. Hyperpolarized water is employed in several dynamic nuclear polarization studies, and hence accurate and rapid quantification of the 1H polarization level is of utmost importance. The solid-state nuclear magnetic resonance spectrum of water acquired under dissolution-dynamic nuclear polarization conditions has revealed lineshapes which become asymmetric at high levels of 1H polarization, which is an interesting fundamental problem in itself, but also complicates data interpretation and can prevent correct estimations of polarization levels achieved. In previous studies, attempts to simulate the 1H spectral lineshape of water as a function of the 1H polarization led to significant disagreement with the experimental results. Here we propose and demonstrate that such simulations, and therefore polarization quantification, can be implemented accurately, in particular by taking into account the detector dead time during 1H signal acquisition that can lead to severe spectral distortions. Based on these findings, we employed an echo-based radiofrequency pulse sequence to achieve distortion-free 1H spectra of hyperpolarized water, and adequate simulations of these echo-based spectra were implemented to extract the absolute 1H polarization level from the hyperpolarized water signal only, thus alleviating the need for lengthy and insensitive measurements of thermal equilibrium signals.


Assuntos
Gelo , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética/métodos , Água
16.
Chemphyschem ; 23(7): e202200072, 2022 04 05.
Artigo em Inglês | MEDLINE | ID: mdl-35099100

RESUMO

In this work the mechanism of methylenecyclobutane hydrogenation over titania-supported Rh, Pt and Pd catalysts was investigated using parahydrogen-induced polarization (PHIP) technique. It was found that methylenecyclobutane hydrogenation leads to formation of a mixture of reaction products including cyclic (1-methylcyclobutene, methylcyclobutane), linear (1-pentene, cis-2-pentene, trans-2-pentene, pentane) and branched (isoprene, 2-methyl-1-butene, 2-methyl-2-butene, isopentane) compounds. Generally, at lower temperatures (150-350 °C) the major reaction product was methylcyclobutane while higher temperature of 450 °C favors the formation of branched products isoprene, 2-methyl-1-butene and 2-methyl-2-butene. PHIP effects were detected for all reaction products except methylenecyclobutane isomers 1-methylcyclobutene and isoprene implying that the corresponding compounds can incorporate two atoms from the same parahydrogen molecule in a pairwise manner in the course of the reaction in particular positions. The mechanisms were proposed for the formation of these products based on PHIP results.


Assuntos
Hidrogênio , Catálise , Hidrogênio/química , Hidrogenação , Espectroscopia de Ressonância Magnética
18.
J Am Chem Soc ; 143(34): 13694-13700, 2021 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-34406748

RESUMO

The hyperpolarization of nuclear spins is a game-changing technology that enables hitherto inaccessible applications for magnetic resonance in chemistry and biomedicine. Despite significant advances and discoveries in the past, however, the quest to establish efficient and effective hyperpolarization methods continues. Here, we describe a new method that combines the advantages of direct parahydrogenation, high polarization (P), fast reaction, and low cost with the broad applicability of polarization transfer via proton exchange. We identified the system propargyl alcohol + pH2 → allyl alcohol to yield 1H polarization in excess of P ≈ 13% by using only 50% enriched pH2 at a pressure of ≈1 bar. The polarization was then successfully relayed via proton exchange from allyl alcohol to various target molecules. The polarizations of water and alcohols (as target molecules) approached P ≈ 1% even at high molar concentrations of 100 mM. Lactate, glucose, and pyruvic acid were also polarized, but to a lesser extent. Several potential improvements of the methodology are discussed. Thus, the parahydrogen-induced hyperpolarization relayed via proton exchange (PHIP-X) is a promising approach to polarize numerous molecules which participate in proton exchange and support new applications for magnetic resonance.

19.
Anal Chem ; 93(24): 8476-8483, 2021 06 22.
Artigo em Inglês | MEDLINE | ID: mdl-34102835

RESUMO

We report on a robust and low-cost parahydrogen generator design employing liquid nitrogen as a coolant. The core of the generator consists of catalyst-filled spiral copper tubing, which can be pressurized to 35 atm. Parahydrogen fraction >48% was obtained at 77 K with three nearly identical generators using paramagnetic hydrated iron oxide catalysts. Parahydrogen quantification was performed on the fly via benchtop NMR spectroscopy to monitor the signal from residual orthohydrogen-parahydrogen is NMR silent. This real-time quantification approach was also used to evaluate catalyst activation at up to 1.0 standard liter per minute flow rate. The reported inexpensive device can be employed for a wide range of studies employing parahydrogen as a source of nuclear spin hyperpolarization. To this end, we demonstrate the utility of this parahydrogen generator for hyperpolarization of concentrated sodium [1-13C]pyruvate, a metabolic contrast agent under investigation in numerous clinical trials. The reported pilot optimization of SABRE-SHEATH (signal amplification by reversible exchange-shield enables alignment transfer to heteronuclei) hyperpolarization yielded 13C signal enhancement of over 14,000-fold at a clinically relevant magnetic field of 1 T corresponding to approximately 1.2% 13C polarization-if near 100% parahydrogen would have been employed, the reported value would be tripled to 13C polarization of 3.5%.


Assuntos
Imageamento por Ressonância Magnética , Nitrogênio , Campos Magnéticos , Espectroscopia de Ressonância Magnética , Isótopos de Nitrogênio
20.
Chemphyschem ; 22(14): 1421-1440, 2021 07 16.
Artigo em Inglês | MEDLINE | ID: mdl-33969590

RESUMO

Parahydrogen-induced polarization with heterogeneous catalysts (HET-PHIP) has been a subject of extensive research in the last decade since its first observation in 2007. While NMR signal enhancements obtained with such catalysts are currently below those achieved with transition metal complexes in homogeneous hydrogenations in solution, this relatively new field demonstrates major prospects for a broad range of advanced fundamental and practical applications, from providing catalyst-free hyperpolarized fluids for biomedical magnetic resonance imaging (MRI) to exploring mechanisms of industrially important heterogeneous catalytic processes. This review covers the evolution of the heterogeneous catalysts used for PHIP observation, from metal complexes immobilized on solid supports to bulk metals and single-atom catalysts and discusses the general visions for maximizing the obtained NMR signal enhancements using HET-PHIP. Various practical applications of HET-PHIP, both for catalytic studies and for potential production of hyperpolarized contrast agents for MRI, are described.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...