Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 23(4)2023 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-36850819

RESUMO

Hemodynamic monitoring technologies are evolving continuously-a large number of bedside monitoring options are becoming available in the clinic. Methods such as echocardiography, electrical bioimpedance, and calibrated/uncalibrated analysis of pulse contours are becoming increasingly common. This is leading to a decline in the use of highly invasive monitoring and allowing for safer, more accurate, and continuous measurements. The new devices mainly aim to monitor the well-known hemodynamic variables (e.g., novel pulse contour, bioreactance methods are aimed at measuring widely-used variables such as blood pressure, cardiac output). Even though hemodynamic monitoring is now safer and more accurate, a number of issues remain due to the limited amount of information available for diagnosis and treatment. Extensive work is being carried out in order to allow for more hemodynamic parameters to be measured in the clinic. In this review, we identify and discuss the main sensing strategies aimed at obtaining a more complete picture of the hemodynamic status of a patient, namely: (i) measurement of the circulatory system response to a defined stimulus; (ii) measurement of the microcirculation; (iii) technologies for assessing dynamic vascular mechanisms; and (iv) machine learning methods. By analyzing these four main research strategies, we aim to convey the key aspects, challenges, and clinical value of measuring novel hemodynamic parameters in critical care.


Assuntos
Cuidados Críticos , Hemodinâmica , Humanos , Frequência Cardíaca , Pressão Sanguínea , Débito Cardíaco
2.
Artigo em Inglês | MEDLINE | ID: mdl-34891230

RESUMO

The blood pressure (BP) cuff can be used to modulate blood flow and propagation of pressure pulse along the artery. In our previous work, we researched methods to adapt cuff modulation techniques for pulse transit time vs. BP calibration and for measurement of other hemodynamic indices of potential interest to critical care, such as arterial compliance. A model characterized the response of the vasculature located directly under the cuff, but assumed that no significant changes occur in the distal vasculature.This study has been tailored to gain insights into the response of distal BP and pulse transit time to cuff inflation. Invasive BP data collected downstream from the cuff demonstrates that highly dynamic processes occur in the distal arm during cuff inflation. Mean arterial pressure increases in the distal artery by up to 20 mmHg, leading to a decrease in pulse transit time of up to 20 ms. Clinical Relevance: Such significant changes need to be taken into account in order to improve non-invasive BP estimations and to enable inference of other hemodynamic parameters from vasculature response to cuff inflation. A simple model is developed in order to reproduce the observed behaviors. The lumped-parameter model demonstrates opportunities for cuff modulation measurements which can reveal information on parameters such as systemic resistance, distal arterial, venous compliances and artery-vein interaction.


Assuntos
Determinação da Pressão Arterial , Análise de Onda de Pulso , Pressão Sanguínea , Frequência Cardíaca , Hemodinâmica
3.
Br J Anaesth ; 126(2): 404-414, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33213832

RESUMO

BACKGROUND: We examined whether a context and process-sensitive 'intelligent' checklist increases compliance with best practice compared with a paper checklist during intensive care ward rounds. METHODS: We conducted a single-centre prospective before-and-after mixed-method trial in a 35 bed medical and surgical ICU. Daily ICU ward rounds were observed during two periods of 8 weeks. We compared paper checklists (control) with a dynamic (digital) clinical checklist (DCC, intervention). The primary outcome was compliance with best clinical practice, measured as the percentages of checked items and unchecked critical items. Secondary outcomes included ICU stay and the usability of digital checklists. Data are presented as median (interquartile range). RESULTS: Clinical characteristics and severity of critical illness were similar during both control and intervention periods of study. A total of 36 clinicians visited 197 patients during 352 ward rounds using the paper checklist, compared with 211 patients during 366 ward rounds using the DCC. Per ICU round, a median of 100% of items (94.4-100.0) were completed by DCC, compared with 75.1% (66.7-86.4) by paper checklist (P=0.03). No critical items remained unchecked by the DCC, compared with 15.4% (8.3-27.3) by the paper checklist (P=0.01). The DCC was associated with reduced ICU stay (1 day [1-3]), compared with the paper checklist (2 days [1-4]; P=0.05). Usability of the DCC was judged by clinicians to require further improvement. CONCLUSIONS: A digital checklist improved compliance with best clinical practice, compared with a paper checklist, during ward rounds on a mixed ICU. CLINICAL TRIAL REGISTRATION: NCT03599856.


Assuntos
Inteligência Artificial , Lista de Checagem , Cuidados Críticos/normas , Sistemas de Apoio a Decisões Clínicas , Unidades de Terapia Intensiva/normas , Papel , Padrões de Prática Médica/normas , Visitas de Preceptoria/normas , Atitude Frente aos Computadores , Benchmarking/normas , Fidelidade a Diretrizes/normas , Nível de Saúde , Humanos , Tempo de Internação , Segurança do Paciente , Guias de Prática Clínica como Assunto/normas , Estudos Prospectivos , Melhoria de Qualidade/normas , Indicadores de Qualidade em Assistência à Saúde/normas
4.
Comput Methods Programs Biomed ; 196: 105492, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32603986

RESUMO

BACKGROUND AND OBJECTIVES: Measurement of arterial compliance is recognized as important for clinical use and for enabling better understanding of circulatory system regulation mechanisms. Estimation of arterial compliance involves either a direct measure of the ratio between arterial volume and pressure changes or an inference from the pulse wave velocity (PWV). In this study we demonstrate an approach to assess arterial compliance by fusion of these two information sources. The approach is based on combining oscillometry as used for blood pressure inference and PWV measurements based on ECG/PPG. Enabling reliable arterial compliance measurements will contribute to the understanding of regulation mechanisms of the arterial tree, possibly establishing arterial compliance as a key measure relevant in hemodynamic monitoring. METHODS: A measurement strategy, a physiological model, and a framework based on Bayesian principles are developed for measuring changes in arterial compliance based on combining oscillometry and PWV data. A simulation framework is used to study and validate the algorithm and measurement principle in detail, motivated by previous experimental findings. RESULTS: Simulations demonstrate the possibility of inferring arterial compliance via fusion of simultaneously acquired volume/pressure relationships and PWV data. In addition, the simulation framework demonstrates how Bayesian principles can be used to handle low signal - to - noise ratio and partial information loss. CONCLUSIONS: The developed simulation framework shows the feasibility of the proposed approach for assessment of arterial compliance by combining multiple data sources. This represents a first step towards integration of arterial compliance measurements in hemodynamic monitoring using existing clinical technology. The Bayesian approach is of particular relevance for such patient monitoring settings, where measurements are repeated frequently, context is relevant, and data is affected by artefacts. In addition, the simulation framework is necessary for future clinical-study design, in order to determine device specifications and the extent to which noise affects the inference process.


Assuntos
Artérias , Análise de Onda de Pulso , Teorema de Bayes , Pressão Sanguínea , Complacência (Medida de Distensibilidade) , Humanos , Oscilometria
5.
Artigo em Inglês | MEDLINE | ID: mdl-30222573

RESUMO

We present RegressionExplorer, a Visual Analytics tool for the interactive exploration of logistic regression models. Our application domain is Clinical Biostatistics, where models are derived from patient data with the aim to obtain clinically meaningful insights and consequences. Development and interpretation of a proper model requires domain expertise and insight into model characteristics. Because of time constraints, often a limited number of candidate models is evaluated. RegressionExplorer enables experts to quickly generate, evaluate, and compare many different models, taking the workflow for model development as starting point. Global patterns in parameter values of candidate models can be explored effectively. In addition, experts are enabled to compare candidate models across multiple subpopulations. The insights obtained can be used to formulate new hypotheses or to steer model development. The effectiveness of the tool is demonstrated for two uses cases: prediction of a cardiac conduction disorder in patients after receiving a heart valve implant and prediction of hypernatremia in critically ill patients.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...