Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Comput Methods Biomech Biomed Engin ; 18(13): 1468-73, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-24830356

RESUMO

In order to increase the lifetime of the total hip endoprosthesis, it is necessary to understand mechanisms leading to its failure. In this work, we address volumetric wear of the artificial cup, in particular the effect of its inclination with respect to the vertical. Volumetric wear was calculated by using mathematical models for resultant hip force, contact stress and penetration of the prosthesis head into the cup. Relevance of the dependence of volumetric wear on inclination of the cup (its abduction angle ϑA) was assessed by the results of 95 hips with implanted endoprosthesis. Geometrical parameters obtained from standard antero-posterior radiographs were taken as input data. Volumetric wear decreases with increasing cup abduction angle ϑA. The correlation within the population of 95 hips was statistically significant (P = 0.006). Large cup abduction angle minimises predicted volumetric wear but may increase the risk for dislocation of the artificial head from the cup in the one-legged stance. Cup abduction angle and direction of the resultant hip force may compensate each other to achieve optimal position of the cup with respect to wear and dislocation in the one-legged stance for a particular patient.


Assuntos
Artroplastia de Quadril/instrumentação , Prótese de Quadril , Fenômenos Biomecânicos , Quadril/anatomia & histologia , Quadril/fisiopatologia , Humanos , Teste de Materiais , Modelos Teóricos , Polietileno/química , Desenho de Prótese , Estresse Mecânico
2.
Eur Spine J ; 22(3): 633-41, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22922802

RESUMO

PURPOSE: Surgical treatment of thoracolumbar osteomyelitis consists of radical debridement, reconstruction of anterior column either with or without posterior stabilization. The objective of present study is to evaluate a case series of patients with osteomyelitis of thoracic and lumbar spine treated by single, posterior approach with posterior instrumentation and anterior column reconstruction. METHODS: Seventeen patients underwent clinical and radiological evaluation pre and postoperatively with latest follow-up at 19 months (8-56 months) after surgery. Parameters assessed were site of infection, causative organism, angle of deformity, blood loss, duration of surgery, ICU stay, deformity correction, time to solid bony fusion, ambulatory status, neurologic status (ASIA impairment scale), and functional outcome (Kirkaldy-Willis criteria). RESULTS: Mean operating time was 207 min and average blood loss 1,150 ml. Patients spent 2 (1-4) days in ICU and were able to walk unaided 1.6 (1-2) days after surgery. Infection receded in all 17 patients postoperatively. Solid bony fusion occurred in 15 out of 17 patients (88 %) on average 6.3 months after surgery. Functional outcome was assessed as excellent or good in 82 % of cases. Average deformity correction was 8 (1-18) degrees, with loss of correction of 4 (0-19) degrees at final follow-up. CONCLUSIONS: Single, posterior approach addressing both columns poses safe alternative in treatment of pyogenic vertebral osteomyelitis of thoracic and lumbar spine. It proved to be less invasive resulting in faster postoperative recovery.


Assuntos
Vértebras Lombares/cirurgia , Osteomielite/cirurgia , Fusão Vertebral/instrumentação , Vértebras Torácicas/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Desbridamento , Descompressão Cirúrgica , Feminino , Humanos , Vértebras Lombares/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Osteomielite/diagnóstico por imagem , Radiografia , Procedimentos de Cirurgia Plástica/métodos , Fusão Vertebral/métodos , Vértebras Torácicas/diagnóstico por imagem , Resultado do Tratamento
3.
Skeletal Radiol ; 32(12): 679-86, 2003 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-13680199

RESUMO

PURPOSE: To develop a new mathematical model for calculating the volumetric wear of polyethylene cups from known values of the radius of the prosthesis head, the extent of linear wear and the direction of linear wear determined from standard antero-posterior radiographs. METHOD: A new mathematical model was developed. The results of this new mathematical model were compared with the results obtained using the standard, frequently used mathematical model, which takes into consideration only the radius of the prosthesis head and the extent of linear wear of the polyethylene cups. The results of both mathematical models were further compared with the results obtained by direct measurement of volumetric wear using the fluid displacement method. RESULTS: Comparison of the mathematical models shows that the average volumetric wear calculated using the new mathematical model is 8.5% smaller than the average volumetric wear determined by the fluid displacement method, while the average volumetric wear calculated by standard mathematical model is 17.5% higher. The results of the new mathematical model are, thus, notably less biased than those of the standard one. CONCLUSION: In calculating the volumetric wear from antero-posterior radiographs, not only the radius of the prosthesis head and the extent of the linear wear but also the direction of the latter has to be considered.


Assuntos
Prótese de Quadril , Polietileno/uso terapêutico , Adulto , Idoso , Idoso de 80 Anos ou mais , Viés , Terapia Combinada/estatística & dados numéricos , Análise de Falha de Equipamento , Feminino , Prótese de Quadril/estatística & dados numéricos , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Desenho de Prótese/estatística & dados numéricos , Intensificação de Imagem Radiográfica , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...