Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
1.
J Nucl Med ; 65(6): 923-930, 2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38637144

RESUMO

[177Lu]Lu-DOTATATE has been approved for progressive and inoperable gastroenteropancreatic neuroendocrine tumors (GEP-NETs) that overexpress somatostatin receptors. The absorbed doses by limiting organs and tumors can be quantified by serial postinfusion scintigraphy measurements of the γ-emissions from 177Lu. The objective of this work was to explore how postinfusion [177Lu]Lu-DOTATATE dosimetry could influence clinical management by predicting treatment efficacy (tumor shrinkage and survival) and toxicity. Methods: Patients with GEP-NETs treated with [177Lu]Lu-DOTATATE between 2016 and 2022 and who underwent dosimetry were included. Absorbed doses were calculated for healthy organs (liver, kidneys, bone marrow, and spleen) and tumors using PLANET Dose and the local energy deposition method based on serial posttreatment SPECT/CT. Up to 5 lesions per site were selected and measured on images collected at baseline and 3 mo after treatment end (measurement masked to the somatostatin receptor imaging uptake). For toxicity assessment, laboratory parameters were regularly monitored. Clinical data, including time to death or progression, were collected from the patients' health records. Correlations between absorbed doses by organs and toxicity and between absorbed doses by lesions and tumor volume variation were studied using regression models. Results: In total, 35 dosimetric studies were performed in patients with mostly grade 2 (77%) tumors and metastases in liver (89%), lymph nodes (77%), and bone (34%), and 146 lesions were analyzed: 1-9 lesions per patient, mostly liver metastases (65%) and lymph nodes (25%). The median total absorbed dose by tumors was 94.4 Gy. The absorbed doses by tumors significantly decreased between cycles. The absorbed dose by tumors was significantly associated with tumor volume variation (P < 0.001) 3 mo after treatment end, and it was a significant prognostic factor for survival. Toxicity analysis showed a correlation between the decrease of hematologic parameters such as lymphocytes or platelet concentrations and the absorbed doses by the spleen or bone marrow. The mean absorbed dose by the kidneys was not correlated with nephrotoxicity during the studied period. Conclusion: In patients treated with [177Lu]Lu-DOTATATE for GEP-NETs, tumor and healthy organ dosimetry can predict survival and toxicities, thus influencing clinical management.


Assuntos
Relação Dose-Resposta à Radiação , Neoplasias Intestinais , Tumores Neuroendócrinos , Octreotida , Compostos Organometálicos , Neoplasias Pancreáticas , Medicina de Precisão , Radiometria , Neoplasias Gástricas , Humanos , Tumores Neuroendócrinos/radioterapia , Tumores Neuroendócrinos/diagnóstico por imagem , Tumores Neuroendócrinos/patologia , Octreotida/análogos & derivados , Octreotida/uso terapêutico , Neoplasias Pancreáticas/radioterapia , Neoplasias Pancreáticas/diagnóstico por imagem , Masculino , Compostos Organometálicos/uso terapêutico , Feminino , Neoplasias Gástricas/radioterapia , Neoplasias Gástricas/diagnóstico por imagem , Neoplasias Gástricas/metabolismo , Neoplasias Gástricas/patologia , Pessoa de Meia-Idade , Idoso , Neoplasias Intestinais/radioterapia , Neoplasias Intestinais/diagnóstico por imagem , Neoplasias Intestinais/patologia , Adulto , Idoso de 80 Anos ou mais , Resultado do Tratamento , Estudos Retrospectivos
2.
Appl Radiat Isot ; 206: 111211, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38309117

RESUMO

The influence of several parameters involved in the 68Ga radiolabeling of FAPI-46 was studied at the scale of the automated reaction. Among the buffers tested, HEPES 0.3 M pH 4 allowed both high radiochemical purity (RCP) and radiochemical yield (RCY), without prepurification of 68Ga but after final purification of [68Ga]Ga-FAPI-46 on a C18 cartridge. A longer reaction time did not show significant benefit on the RCP, while higher loads of FAPI-46 and gentisic acid as anti-radiolysis compound allowed better RCY.

3.
Nutrients ; 15(13)2023 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-37447367

RESUMO

18F-FDG PET-CT is routinely performed as part of the initial staging of numerous cancers. Other than having descriptive, predictive and prognostic values for tumors, 18F-FDG PET-CT provides full-body data, which could inform on concurrent pathophysiological processes such as malnutrition. To test this hypothesis, we measured the 18F-FDG uptake in several organs and evaluated their association with weight loss in patients at diagnosis of esophageal cancer. Forty-eight patients were included in this retrospective monocentric study. 18F-FDG uptake quantification was performed in the brain, the liver, the spleen, bone marrow, muscle and the esophageal tumor itself and was compared between patients with different amounts of weight loss. We found that Total Lesion Glycolysis (TLG) and peak Standardized Uptake Values (SUVpeak) measured in the brain correlated with the amount of weight loss: TLG was, on average, higher in patients who had lost more than 5% of their usual weight, whereas brain SUVpeak were, on average, lower in patients who had lost more than 10% of their weight. Higher TLG and lower brain SUVpeak were associated with worse OS in the univariate analysis. This study reports a new and significant association between 18F-FDG uptake in the brain and initial weight loss in patients with esophageal cancer.


Assuntos
Neoplasias Esofágicas , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Humanos , Fluordesoxiglucose F18 , Estudos Retrospectivos , Prognóstico , Redução de Peso , Neoplasias Esofágicas/diagnóstico por imagem , Carga Tumoral , Glicólise
4.
Clin Physiol Funct Imaging ; 43(5): 382-392, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37211979

RESUMO

PURPOSE: The agreement between the Stratos DR and Discovery A densitometers was assessed for measurements of whole-body (WB) and regional fat mass (FM), fat-free soft tissue (FFST) and bone mineral density (BMD). Moreover, the precision of the Stratos DR was also evaluated. METHODS: Fifty participants (35 women, 70%) were measured consecutively, once on the Discovery A and once on the Stratos DR. In a subgroup of participants (n = 29), two successive measurements with the Stratos DR were also performed. RESULTS: FM, FFST and BMD measured with the two devices were highly correlated, with a coefficient of correlation ranging from 0.80 to 0.99. Bland-Altman analyses indicated significant bias between the two devices for all measurements. Thus, compared to the Discovery A, the Stratos DR underestimated WB BMD and WB and regional FM and FFST, with the exception of trunk FM and visceral adipose tissue (VAT), which were overestimated. Precision error for the Stratos DR, when expressed as root mean square-coefficient of variation (RMS-CV%) for FM, was 1.4% for WB, 3.0% for the gynoid and android regions, and 15.9% for VAT. The RMS-CV% for FFST was 1.0% for WB. The root mean square of standard deviation for WB BMD was 0.018 g/cm², corresponding to a 1.4% CV. The least significant change was 0.050 g/cm² (SD), and 4.0% was considered to be a significant biological change. CONCLUSIONS: Differences between the Stratos DR and Discovery A measurements are significant and require the use of translational cross-calibration equations. For most of the BMD and body composition parameters, our results demonstrated good Stratos DR precision.


Assuntos
Composição Corporal , Densidade Óssea , Humanos , Feminino , Absorciometria de Fóton , Tecido Adiposo/diagnóstico por imagem , Gordura Intra-Abdominal
5.
Eur J Drug Metab Pharmacokinet ; 48(4): 329-339, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37184824

RESUMO

BACKGROUND AND OBJECTIVE: Lu-177 DOTATATE (Lutathera®) is a radiolabeled analog of somatostatin administered intravenously in patients with somatostatin receptor-positive gastroenteropancreatic neuroendocrine tumors. Biodistribution of Lu-177 DOTATATE in tumor and healthy tissues can be monitored by serial post-injection scintigraphy imaging. Patient exposure to the drug is variable with the recommended fixed dosage, and hence there is a variable response to treatment. The aim of this work was to study the pharmacokinetics of Lu-177 DOTATATE by a population modeling approach, based on single-photon emission computed tomography (SPECT)/computed tomography (CT) images used as surrogate of plasma concentrations to study the interindividual variability and finally optimize an individual dosage. METHODS: From a retrospective study, SPECT/CT images were acquired at 4 h, 24 h, 72 h, and 192 h postadministration. From these images, volumic activities were calculated in blood and bone marrow. An individual non-compartmental pharmacokinetic analysis was performed, and the mean pharmacokinetic parameters of each tissue were compared together and with reference data. Blood volumic activities were then used to perform a population pharmacokinetic analysis (NONMEM). RESULTS: The pharmacokinetic parameters (non-compartmental analysis) obtained from blood (clearance [CL] = 2.65 L/h, volume of distribution at steady state [Vss] = 309 L, elimination half-life [t1/2] = 86.3 h) and bone marrow (CL =1.68 L/h, Vss = 233 L, t1/2 = 98.8 h) were statistically different from each other and from reference values (CL = 4.50 L/h, Vss = 460 L, t1/2 = 71.0 h) published in the literature. SPECT/CT blood images were used as a surrogate of plasma concentrations to develop a population pharmacokinetic model. Weight was identified as covariate on volume of the central compartment, reducing the interindividual variability of all population pharmacokinetic parameters. CONCLUSION: This study is a proof of concept that obtaining pharmacokinetic parameters with image-based blood concentration is possible. Obtaining observed concentrations from SPECT/CT images, without the need for blood sampling, is a real advantage for the patient and the drug monitoring. Pharmacokinetic modeling could be combined with a deep learning model for automatic contouring and allow precise patient-specific dose adjustment in a non-invasive manner.


Assuntos
Tumores Neuroendócrinos , Radioisótopos , Humanos , Compostos Radiofarmacêuticos/farmacocinética , Lutécio , Tumores Neuroendócrinos/diagnóstico por imagem , Tumores Neuroendócrinos/patologia , Distribuição Tecidual , Estudos Retrospectivos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tomografia Computadorizada por Raios X
6.
Pharmaceutics ; 15(4)2023 Mar 24.
Artigo em Inglês | MEDLINE | ID: mdl-37111537

RESUMO

The widespread use of peptide receptor radionuclide therapy (PRRT) represents a major therapeutic breakthrough in nuclear medicine, particularly since the introduction of 177Lu-radiolabeled somatostatin analogs. These radiopharmaceuticals have especially improved progression-free survival and quality of life in patients with inoperable metastatic gastroenteropancreatic neuroendocrine tumors expressing somatostatin receptors. In the case of aggressive or resistant disease, the use of somatostatin derivatives radiolabeled with an alpha-emitter could provide a promising alternative. Among the currently available alpha-emitting radioelements, actinium-225 has emerged as the most suitable candidate, especially regarding its physical and radiochemical properties. Nevertheless, preclinical and clinical studies on these radiopharmaceuticals are still few and heterogeneous, despite the growing momentum for their future use on a larger scale. In this context, this report provides a comprehensive and extensive overview of the development of 225Ac-labeled somatostatin analogs; particular emphasis is placed on the challenges associated with the production of 225Ac, its physical and radiochemical properties, as well as the place of 225Ac-DOTATOC and 225Ac-DOTATATE in the management of patients with advanced metastatic neuroendocrine tumors.

7.
Healthcare (Basel) ; 10(11)2022 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-36360590

RESUMO

Securing both the patient and radiopharmaceuticals (RPs) circuit is an essential concern in nuclear medicine (NM). These circuits converge at the RP administration phase, a key step in patient management in NM. In a continuous quality improvement approach, we developed and implemented an evaluation of professional practices (EPPs) methodology focused on RPs injection to identify and correct deviations from good practices. The nuclear medicine technologists (NMTs) of a single center were evaluated. A specific audit grid was designed for this purpose, covering 4 main themes. Following the audit campaign, an improvement action plan was set up to address the non-conformities observed. Nine NMTs were audited on 4 RPs injections each. The mean total score was 93.36% with, on average, 7.01% and 3.00% of unmet and partially met criteria, respectively. In view of the non-compliance rates of hygiene and radiation protection items, theoretical reviews of these themes were included in the improvement action plan. As a part of the quality assurance system of a healthcare unit, EPPs are useful for identifying and correcting practice deviations at an early stage. They should be regularly repeated and combined with rigorous training and qualification of operators involved in RPs injection.

8.
Eur J Hosp Pharm ; 2022 Sep 13.
Artigo em Inglês | MEDLINE | ID: mdl-36100369

RESUMO

OBJECTIVES: 177Lu-oxodotreotide (Lutathera) is an intravenous peptide receptor radionuclide therapy to treat unresectable metastatic digestive neuroendocrine tumours. The recommended method for Lutathera administration is gravity infusion; however, other appropriate and safe techniques are possible. This work compares two infusion methods from a medico-economic, radiation protection, efficiency and practicality point of view. METHODS: Two infusion methods were studied, either involving a volumetric infusion pump (method 1) or a peristaltic pump (method 2). For each method, the mean residual activity per vial and the mean injection time were compared. Occupational radiation exposure was measured. The cost of initial equipment and consumables for one administration was determined. Feedback from operators and past incidents during injections were collected through a survey. RESULTS: Three operators performed 219 Lutathera injections over 70 months: 60.7% (133) with method 1 and 39.3% (86) with method 2. After infusion, the mean residual activity in vial was 124.3±16.9 MBq with method 1 and 80.9±19.3 MBq with method 2 (34.9% decrease). The average administration time was 41±7.2 min with method 1 and 39±8.5 min with method 2. Occupational exposures obtained with both methods were very low and quite similar. Method 1 required an initial investment of 1165.8 US$ plus 4.0 US$ of supplies for each administration. Initial investment for method 2 was comparable (1261.4 US$) but supplies cost per administration was higher (12.5 US$). Two major incidents were recorded with method 1 and none with method 2. From operators' experience, method 2 felt safer and more suitable. CONCLUSIONS: Method 2 appeared to be convenient and secure, despite a higher cost per injection. It could also be applied to new radioligand therapies such as 177Lu-PSMA or 225Ac-Dotatate.

9.
PDA J Pharm Sci Technol ; 76(5): 416-433, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35169040

RESUMO

Gallium-68 radiolabeling is an increasingly common activity in radiopharmacy. Single vial cold kits to radiolabel DOTATOC and PSMA-11 with 68Ga were developed, either for manual or automated preparation. Both approaches are very specific and require aseptic compounding skills, raising the need for dedicated training. The aim of this work was to design and implement an integrative media-fill test (MFT) protocol inspired by 68Ga kit-based radiopharmaceuticals for operator qualification, suitable for both manual and automated preparation simulations. Three custom MFT protocols (two manual and one automated simulations) compatible with specific radiopharmacy equipment were designed for operator training. During MFT sessions, the microbiological quality of the working environment was monitored by surface and air sampling. The sensitivity of the tryptic soy broth (TSB) and the influence of the number of punctures performed in each vial on the units positivity were also studied. Four operators were evaluated and carried out in triplicate the three MFTs. None of the 336 incubated units showed turbidity, although 27.8% of surface samples and 11.1% of air samples were positive (1-4 CFU). Over 36 MFT sessions, 15 contaminations of the working area by TSB drops occurred. TSB sensitivity was estimated >3.12 UFC. Units positivity showed a probable relationship with the number of punctures in a vial and, more obviously, with the contamination level of the vial stopper. As a part of a general sterile compounding instruction, these MFT protocols may be useful tools for initial and continuing training of operators carrying out manual and automated 68Ga radiolabeling.


Assuntos
Radioisótopos de Gálio , Compostos Radiofarmacêuticos , Contaminação de Medicamentos
10.
Hell J Nucl Med ; 24(2): 165-166, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34352056

RESUMO

Lutetium-177 (177Lu)-based post-therapeutic imaging allows visualization of treated lesions andabsorbed dose measurement. There is an increasing number of cadmium-zinc-telluride (CZT) gamma-cameras in nuclear medicine departments but until now these devices were not adapted to the medium-energy emission of 177Lu photons. We present here in the first reported images acquired with a new collimator designed for CZT gamma-camera compared to a conventional sodium iodide (NaI) (Tl) gamma-camera. Post-therapeutic 177Lu-DOTATATE imaging on a CZT device with a medium energy high resolution (MEHRS)-collimator are promising and support the widespread of both 177Lu-based peptide-receptor radionuclide therapy (PRRT) and CZT gamma-cameras.


Assuntos
Telúrio , Tomografia Computadorizada de Emissão de Fóton Único , Cádmio , Humanos , Tomografia por Emissão de Pósitrons , Cintilografia , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único , Zinco
11.
EJNMMI Radiopharm Chem ; 6(1): 2, 2021 Jan 07.
Artigo em Inglês | MEDLINE | ID: mdl-33411035

RESUMO

BACKGROUND: The purpose of this work was to design, validate and implement a media-fill test combined with fluorescein (MFT-F) for the specific qualification and training of radiopharmacy operators, in accordance with United States Pharmacopeia General Chapter 797 and European Good Manufacturing Practices. MFT-F was embedded in the quality management system of our radiopharmacy unit. Its validation involved fluorescein concentration choice, media growth promotion test and evaluation protocol controls (with or without intentional aseptic mistakes). Each operator was evaluated following a three-part evaluation form. Evaluation criteria related to garbing and hygiene, fluorescent contamination and bacteriological contamination (pre- and post-evaluation environment controls and MFT-F samples). Combined MFT-F allowed the assessment of aseptic compounding skills and non-contamination of the working area through a single evaluation. It was also designed to fit the constraints of radiopharmacy common practice related to radiation protection equipment and to the small volumes handled. RESULTS: A 0.01% fluorescein concentration was chosen to prepare MFT-F. Addition of fluorescein in the culture medium did not jeopardize its growth properties according to growth promotion test. Eleven operators were evaluated and carried out 3 MFT-F over 3 successive days. Pre- and post-evaluation bacteriological controls of every session showed no CFU of microbiological contaminant above 5. All operators validated the garbing and hygiene evaluation, with an average score of 92.7%. All operators validated the fluorescent contamination evaluation, with an average score of 29.4 out of 30. None of the MFT-F samples showed any visible bacterial growth after incubation. CONCLUSIONS: Combined MFT-F, as a part of a comprehensive sterile compounding training program, appeared as a convenient and promising tool to increase both the sterile compounding safety and awareness of radioactive contamination in radiopharmacy.

12.
Med Phys ; 47(9): 4602-4615, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32632928

RESUMO

PURPOSE: The aim of this study was to quantitatively compare five commercial dosimetric software platforms based on the analysis of clinical datasets of patients who benefited from peptide receptor radionuclide therapy (PRRT) with 177 Lu-DOTATATE (LUTATHERA® ). METHODS: The dosimetric analysis was performed on two patients during two cycles of PRRT with 177 Lu. Single photon emission computed tomography/computed tomography images were acquired at 4, 24, 72, and 192 h post injection. Reconstructed images were generated using Dosimetry Toolkit® (DTK) from Xeleris™ and HybridRecon-Oncology version_1.3_Dicom (HROD) from HERMES. Reconstructed images using DTK were analyzed using the same software to calculate time-integrated activity coefficients (TIAC), and mean absorbed doses were estimated using OLINDA/EXM V1.0 with mass correction. Reconstructed images from HROD were uploaded into PLANET® OncoDose from DOSIsoft, STRATOS from Phillips, Hybrid Dosimetry Module™ from HERMES, and SurePlan™ MRT from MIM. Organ masses, TIACs, and mean absorbed doses were calculated from each application using their recommendations. RESULTS: The majority of organ mass estimates varied by <9.5% between all platforms. The highest variability for TIAC results between platforms was seen for the kidneys (28.2%) for the two patients and the two treatment cycles. Relative standard deviations in mean absorbed doses were slightly higher compared with those observed for TIAC, but remained of the same order of magnitude between all platforms. CONCLUSIONS: When applying a similar processing approach, results obtained were of the same order of magnitude regardless of the platforms used. However, the comparison of the performances of currently available platforms is still difficult as they do not all address the same parts of the dosimetric analysis workflow. In addition, the way in which data are handled in each part of the chain from data acquisition to absorbed doses may be different, which complicates the comparison exercise. Therefore, the dissemination of commercial solutions for absorbed dose calculation calls for the development of tools and standards allowing for the comparison of the performances between dosimetric software platforms.


Assuntos
Tumores Neuroendócrinos , Humanos , Tumores Neuroendócrinos/diagnóstico por imagem , Tumores Neuroendócrinos/radioterapia , Octreotida/uso terapêutico , Radioisótopos , Compostos Radiofarmacêuticos , Receptores de Peptídeos , Software
13.
Clin Nutr ; 38(5): 2121-2126, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-30209026

RESUMO

BACKGROUND & AIMS: Nutrition support is recommended in cachexic patients with cancer. However, there is no clear evidence about its impact on tumour growth. Glycolysis, which is usually higher in cancer than normal cells, can be monitored by 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT) imaging that is widely used for cancer staging and therapy efficacy assessment. Here, we used 18F-FDG PET/CT imaging to investigate whether artificial nutrition has an impact on tumour glucose metabolism in patients with cancer and cachexia. METHODS: This prospective study included ten patients with histologically proven head and neck or oesophageal cancer. All patients underwent 18F-FDG PET/CT imaging at baseline and after (parenteral and/or enteral) nutrition support on average for 7 days. Tumour glucose metabolism changes were evaluated using static (SUVmax, SUVmean and SULpeak) and dynamic (glucose metabolic rate and transport constant rates, k) parameters computed from the 18F-FDG PET/CT data. RESULTS: Artificial nutrition (median energy intake of 21.83 kcal/kg/day [13.16-45.90], protein intake of 0.84 g/kg/day [0.56-1.64]) was administered. Eight patients (80%) received enteral nutrition and two patients (20%) parenteral support. Comparison of 18F-FDG PET/CT parameters did not highlight any significant difference in tumour glucose metabolism before and after the period of nutrition support. CONCLUSIONS: In cachexic patients with head and neck or oesophageal cancer, nutrition support administered according to the current guidelines shows no impact on tumour glucose metabolism, assessed by 18F-FDG PET/CT.


Assuntos
Ingestão de Alimentos/fisiologia , Glucose/metabolismo , Neoplasias de Cabeça e Pescoço , Apoio Nutricional , Idoso , Glicemia/análise , Feminino , Fluordesoxiglucose F18/química , Fluordesoxiglucose F18/farmacocinética , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/metabolismo , Neoplasias de Cabeça e Pescoço/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Estudos Prospectivos
14.
EJNMMI Res ; 8(1): 103, 2018 Nov 29.
Artigo em Inglês | MEDLINE | ID: mdl-30498938

RESUMO

BACKGROUND: This study's aim was to develop our dosimetric methodology using a commercial workstation for the routine evaluation of the organs at risk during peptide receptor radionuclide therapy (PRRT) with 177Lu. METHODS: First, planar and SPECT sensitivity factors were determined on phantoms. The reconstruction parameters were optimized by SPECT/CT image acquisition using a NEMA IEC phantom containing a 500 ml bottle of 177Lu, to simulate a kidney. The recovery coefficients were determined on various phantoms. For the red marrow, this was calculated using a NEMA IEC phantom that contained a centrally placed bottle of 80 ml of 177Lu (to model the L2-L4 red marrow) flanked by two 200 ml bottles with 177Lu to simulate the kidneys. Then, SPECT/CT images were acquired at 4, 24, 72, and 192 h after injection in 12 patients with neuroendocrine tumors who underwent PRRT with 177Lu-DOTATATE. SPECT data were reconstructed using the iterative ordered subset expectation maximization (OSEM) method, with six iterations and ten subsets, attenuation, scatter, recovery resolution corrections, and a Gaussian post-filter of 0.11 cm. The liver, spleen, kidneys, and red marrow dose per administered activity (AD/A admin) values were calculated with the Medical Internal Radiation Dose (MIRD) formalism and the residence times (Dosimetry toolkit® application) using standard and CT imaging-based organ masses (OLINDA/EXM® V1.0 software). RESULTS: Sensitivity factors of 6.11 ± 0.01 and 5.67 ± 0.08 counts/s/MBq were obtained with planar and SPECT/CT acquisitions, respectively. A recovery coefficient of 0.78 was obtained for the modeled L2-L4 red marrow. The mean AD/A admin values were 0.43 ± 0.13 mGy/MBq [0.27-0.91] for kidneys, 0.54 ± 0.58 mGy/MBq [0.12-2.26] for liver, 0.61 ± 0.13 mGy/MBq [0.42-0.89] for spleen, and 0.04 ± 0.02 mGy/MBq [0.01-0.09] for red marrow. The AD/A admin values varied when calculated using the personalized and standard organ mass, particularly for kidneys (p = 1 × 10-7), spleen (p = 0.0069), and red marrow (p = 0.0027). Intra-patient differences were observed especially in organs close to or including tumor cells or metastases. CONCLUSIONS: The obtained AD/A admin values were in agreement with the literature data. This study shows the technical feasibility of patient dosimetry in clinical practice and the need to obtain patient-specific information.

15.
J Nucl Med ; 59(8): 1234-1242, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29674421

RESUMO

We have developed the 16F12 mouse monoclonal antibody (mAb), which targets the Müllerian-inhibiting substance receptor, type II (MISRII), expressed by ovarian tumors. Here, we assessed in preclinical models the possibility of using radiolabeled 16F12 in a theranostic approach for small-volume ovarian peritoneal carcinomatosis, such as after cytoreductive surgery. Methods: DOTA-, DTPA- or deferoxamine mesylate-conjugated 16F12 mAb was radiolabeled with ß-particle (177Lu) or α-particle (213Bi) emitters for therapeutic use and with 89Zr for PET imaging. On the 13th postxenograft day, mice bearing intraperitoneal MISRII-positive AN3CA endometrial carcinoma cell xenografts were treated by conventional intraperitoneal radioimmunotherapy (IP-RIT) with 10 MBq of 177Lu-16F12 or 12.9 MBq of 213Bi-16F12 or by brief intraperitoneal radioimmunotherapy (BIP-RIT) using 50 MBq of 177Lu-16F12 or 37 MBq of 213Bi-16F12. For BIP-RIT, 30 min after injection of the radiolabeled mAbs, the peritoneal cavity was washed to remove the unbound radioactivity. The biodistribution of 177Lu- and 213Bi-16F12 mAbs was determined and then used for dose assessment. Hematologic toxicity was also monitored. Results: The 16F12 mAb was satisfactorily radiolabeled for both therapy and imaging. IP-RIT with 177Lu-16F12 was slightly more efficient in delaying tumor growth than IP-RIT with 213Bi-16F12. Conversely, 213Bi-16F12 was more efficient than 177Lu-16F12 in BIP-RIT. The biodistribution analysis showed that the tumor-to-blood uptake ratio was significantly higher with BIP-RIT than with IP-RIT for both 213Bi- and 177Lu-16F12. Hematologic toxicity was more pronounced with 177Lu-16F12 than with 213Bi-16F12. SPECT/CT images (after BIP-RIT with 177Lu-16F12) and PET/CT images (after injection of 89Zr-16F12 in the tail vein) showed focal uptake at the tumor site. Conclusion: Radiolabeled 16F12 could represent a new theranostic tool for small-volume ovarian peritoneal carcinomatosis. Specifically, 213Bi-16F12-based BIP-RIT could be proposed to selected patients as an alternative adjuvant treatment immediately after cytoreductive surgery. An anti-MISRII mAb is currently being used in a first-in-human study, thus making radiolabeled anti-MISRII mAbs a realistic theranostic option for the clinic.


Assuntos
Anticorpos Monoclonais/química , Anticorpos Monoclonais/uso terapêutico , Neoplasias Ovarianas/diagnóstico por imagem , Neoplasias Ovarianas/radioterapia , Receptores de Peptídeos/imunologia , Receptores de Fatores de Crescimento Transformadores beta/imunologia , Animais , Anticorpos Monoclonais/farmacocinética , Linhagem Celular Tumoral , Desferroxamina/química , Feminino , Compostos Heterocíclicos com 1 Anel/química , Humanos , Marcação por Isótopo , Camundongos , Neoplasias Ovarianas/metabolismo , Ácido Pentético/química , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Radioquímica , Distribuição Tecidual
16.
J Nucl Med ; 58(7): 1045-1053, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-28254869

RESUMO

See an invited perspective on this article on page 1043.This multicenter phase II study investigated a selective radiotherapy dose increase to tumor areas with significant 18F-misonidazole (18F-FMISO) uptake in patients with non-small cell lung carcinoma (NSCLC). Methods: Eligible patients had locally advanced NSCLC and no contraindication to concomitant chemoradiotherapy. The 18F-FMISO uptake on PET/CT was assessed by trained experts. If there was no uptake, 66 Gy were delivered. In 18F-FMISO-positive patients, the contours of the hypoxic area were transferred to the radiation oncologist. It was necessary for the radiotherapy dose to be as high as possible while fulfilling dose-limiting constraints for the spinal cord and lungs. The primary endpoint was tumor response (complete response plus partial response) at 3 mo. The secondary endpoints were toxicity, disease-free survival (DFS), and overall survival at 1 y. The target sample size was set to demonstrate a response rate of 40% or more (bilateral α = 0.05, power 1-ß = 0.95). Results: Seventy-nine patients were preincluded, 54 were included, and 34 were 18F-FMISO-positive, 24 of whom received escalated doses of up to 86 Gy. The response rate at 3 mo was 31 of 54 (57%; 95% confidence interval [CI], 43%-71%) using RECIST 1.1 (17/34 responders in the 18F-FMISO-positive group). DFS and overall survival at 1 y were 0.86 (95% CI, 0.77-0.96) and 0.63 (95% CI, 0.49-0.74), respectively. DFS was longer in the 18F-FMISO-negative patients (P = 0.004). The radiotherapy dose was not associated with DFS when adjusting for the 18F-FMISO status. One toxic death (66 Gy) and 1 case of grade 4 pneumonitis (>66 Gy) were reported. Conclusion: Our approach results in a response rate of 40% or more, with acceptable toxicity. 18F-FMISO uptake in NSCLC patients is strongly associated with poor prognosis features that could not be reversed by radiotherapy doses up to 86 Gy.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/metabolismo , Carcinoma Pulmonar de Células não Pequenas/radioterapia , Fracionamento da Dose de Radiação , Neoplasias Pulmonares/metabolismo , Neoplasias Pulmonares/radioterapia , Misonidazol/análogos & derivados , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Feminino , França , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Misonidazol/farmacocinética , Variações Dependentes do Observador , Compostos Radiofarmacêuticos/farmacocinética , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Taxa de Sobrevida , Resultado do Tratamento , Hipóxia Tumoral/efeitos da radiação
17.
Eur Radiol ; 27(8): 3343-3352, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28101681

RESUMO

OBJECTIVE: The aim of this study was to assess the safety and efficacy of extended liver venous deprivation (eLVD), i.e. combination of right portal vein embolisation and right (accessory right) and middle hepatic vein embolisation before major hepatectomy for future remnant liver (FRL) functional increase. METHODS: eLVD was performed in non-cirrhotic patients referred for major hepatectomy in a context of small FRL (baseline FRL <25% of the total liver volume or FRL function <2.69%/min/m2). All patients underwent 99mTc-mebrofenin hepatobiliary scintigraphy (HBS) and computed tomographic evaluations. RESULTS: Ten consecutive patients underwent eLVD before surgery for liver metastases (n = 8), Klatskin tumour (n = 1) and gallbladder carcinoma (n = 1). FRL function increased by 64.3% (range = 28.1-107.5%) at day 21. In patients with serial measurements, maximum FRL function was at day 7 (+65.7 ± 16%). The FRL volume increased by +53.4% at 7 days (+25 ± 8 cc/day). Thirty-one days (range = 22-45 days) after eLVD, 9/10 patients were resected. No post-hepatectomy liver failure was reported. Two grade II and one grade III complications (Dindo-Clavien classification) occurred. No patient died with-in 90 days following surgery. CONCLUSIONS: eLVD is safe and provides a marked and very rapid increase in liver function, unprecedented for an interventional radiology procedure. KEY POINTS: • eLVD is safe • eLVD provides a marked and very rapid increase in liver function • After eLVD, the FRL-F increased by 64.3% (28.1-107.5%) at day 21 • After eLVD, the maximum FRL-F was obtained at day 7 (+65.7 ± 16%) • After eLVD, the FRL volume increased by +53.4% at 7 days (+25 ± 8 cc/day).


Assuntos
Embolização Terapêutica/métodos , Hepatectomia/métodos , Neoplasias Hepáticas/cirurgia , Fígado/irrigação sanguínea , Idoso , Compostos de Anilina , Neoplasias dos Ductos Biliares/cirurgia , Embolização Terapêutica/efeitos adversos , Feminino , Neoplasias da Vesícula Biliar/cirurgia , Glicina , Hepatectomia/efeitos adversos , Veias Hepáticas , Humanos , Iminoácidos , Tumor de Klatskin/cirurgia , Fígado/diagnóstico por imagem , Fígado/fisiopatologia , Falência Hepática/etiologia , Falência Hepática/prevenção & controle , Testes de Função Hepática , Neoplasias Hepáticas/secundário , Masculino , Pessoa de Meia-Idade , Compostos de Organotecnécio , Veia Porta , Cuidados Pré-Operatórios/métodos , Compostos Radiofarmacêuticos , Estudos Retrospectivos , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tomografia Computadorizada por Raios X
18.
Clin Nucl Med ; 42(1): 50-53, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27801739

RESUMO

We report the case of a 73-year-old man with a documented (renal biopsy) light-chain amyloidosis (AL) imaged with F-AV-1 (F-florbetaben) compared with a volunteer. A cardiac amyloidosis was suspected. As it was an AL and not a transthyretin amyloidosis, F-FDG and F-florbetaben PET/CT were preferred to bone scan. F-FDG scintigraphy showed a focal cardiac hypermetabolism. In addition of the heart, F-florbetaben scintigraphy showed an intense spleen and thyroid pathologic uptake and a moderate salivary gland and kidney uptake. F-florbetaben PET/CT appears to be useful for staging systemic amyloidosis.


Assuntos
Amiloidose/diagnóstico por imagem , Compostos de Anilina , Coração/diagnóstico por imagem , Compostos Radiofarmacêuticos , Estilbenos , Idoso , Amiloidose/patologia , Humanos , Masculino , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Baço/diagnóstico por imagem , Glândula Tireoide/diagnóstico por imagem
19.
BMC Neurol ; 16: 100, 2016 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-27411408

RESUMO

BACKGROUND: In myotonic dystrophy type 1 (DM1), only one FDG-PET study used statistical parametric mapping (SPM) showing frontal reduced FDG-uptake. Our aim was to 1) identify the FDG-PET area with the most severe reduced FDG-uptake using SPM8 in a larger group of patients 2) assess potential correlation between CTG-numbers and FDG-PET. METHODS: FDG-PET was performed in 24 patients and compared to 24 controls. Pearson's correlation was used to analyse correlation. RESULTS: SPM8 revealed Brodmann area 8 as the area with the most severe reduced FDG-uptake. Weak, although not statistically significant, correlation was observed between CTG-numbers and reduced FDG-uptake in Brodmann area 8. CONCLUSION: In DM1, Brodmann area 8 is the area with the most severe reduced FDG-uptake on FDG-PET. Brodmann area 8 reduced FDG-uptake is correlated -although weakly- to CTG-repeat numbers.


Assuntos
Córtex Cerebral/fisiopatologia , Distrofia Miotônica/fisiopatologia , Tomografia por Emissão de Pósitrons/métodos , Adulto , Idoso , Estudos de Casos e Controles , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
20.
J Nucl Med ; 57(7): 1091-5, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27013695

RESUMO

UNLABELLED: The purpose of this study was to compare a routine bone SPECT/CT protocol using CT reconstructed with filtered backprojection (FBP) with an optimized protocol using low-dose CT images reconstructed with adaptive statistical iterative reconstruction (ASiR). METHODS: In this prospective study, enrolled patients underwent bone SPECT/CT, with 1 SPECT acquisition followed by 2 randomized CT acquisitions: FBP CT (FBP; noise index, 25) and ASiR CT (70% ASiR; noise index, 40). The image quality of both attenuation-corrected SPECT and CT images was visually (5-point Likert scale, 2 interpreters) and quantitatively (contrast ratio [CR] and signal-to-noise ratio [SNR]) estimated. The CT dose index volume, dose-length product, and effective dose were compared. RESULTS: Seventy-five patients were enrolled in the study. Quantitative attenuation-corrected SPECT evaluation showed no inferiority for contrast ratio and SNR issued from FBP CT or ASiR CT (respectively, 13.41 ± 7.83 vs. 13.45 ± 7.99 and 2.33 ± 0.83 vs. 2.32 ± 0.84). Qualitative image analysis showed no difference between attenuation-corrected SPECT images issued from FBP CT or ASiR CT for both interpreters (respectively, 3.5 ± 0.6 vs. 3.5 ± 0.6 and 3.6 ± 0.5 vs. 3.6 ± 0.5). Quantitative CT evaluation showed no inferiority for SNR between FBP and ASiR CT images (respectively, 0.93 ± 0.16 and 1.07 ± 0.17). Qualitative image analysis showed no quality difference between FBP and ASiR CT images for both interpreters (respectively, 3.8 ± 0.5 vs. 3.6 ± 0.5 and 4.0 ± 0.1 vs. 4.0 ± 0.2). Mean CT dose index volume, dose-length product, and effective dose for ASiR CT (3.0 ± 2.0 mGy, 148 ± 85 mGy⋅cm, and 2.2 ± 1.3 mSv) were significantly lower than for FBP CT (8.5 ± 3.7 mGy, 365 ± 160 mGy⋅cm, and 5.5 ± 2.4 mSv). CONCLUSION: The use of 70% ASiR blending in bone SPECT/CT can reduce the CT radiation dose by 60%, with no sacrifice in attenuation-corrected SPECT and CT image quality, compared with the conventional protocol using FBP CT reconstruction technique.


Assuntos
Osso e Ossos/diagnóstico por imagem , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tomografia Computadorizada de Emissão/métodos , Idoso , Idoso de 80 Anos ou mais , Artefatos , Relação Dose-Resposta à Radiação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Razão Sinal-Ruído , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...