Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
1.
Front Cardiovasc Med ; 11: 1361761, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38572304

RESUMO

Background and aims: Right phrenic nerve palsy is the most frequent complication of cryoballoon procedures. The SMARTFREEZE™ console (Boston Scientific, St. Paul, MN, USA) has integrated a new tool for diaphragm monitoring-the Diaphragm Movement Sensor; however, it has not been evaluated in clinical practice. We aimed to assess the diagnostic performance of the Diaphragm Movement Sensor based on compound motor action potential data recorded simultaneously. Methods: Thirty consecutive patients (mean age 63.2 ± 10.2 years) were included. We simultaneously recorded the compound motor action potential and the Diaphragm Movement Sensor during cryoapplications in the right pulmonary veins. The right phrenic nerve was paced at 60 per minute, 12 V and 2.9 ms. Compound motor action potential monitoring with a 30% decrease cutoff for the diagnosis of phrenic nerve threatening was considered the gold standard. The Diaphragm Movement Sensor decrease threshold was also set at 30%. Results: Considering compound motor action potential monitoring, phrenic nerve threatening occurred 11 times (in seven patients) among 84 cryoapplications (13.1%) at the right pulmonary veins. The sensitivity and specificity of the Diaphragm Movement Sensor were, respectively, 33% (95% CI: 7%-70%) and 49% (95% CI: 38%-61%; P < 0.001). The predictive positive and negative values for the Diaphragm Movement Sensor were, respectively, 7% (95% CI: 2%-20%) and 86% (95% CI: 72%-95%). The Diaphragm Movement Sensor gave an erroneous diagnosis in 44/84 cryoapplications (52.4%). Conclusions: The diagnostic performance of the Diaphragm Movement Sensor is low, and the relevance of its use in clinical practice may be debated.

2.
J Am Coll Cardiol ; 82(7): 590-599, 2023 08 15.
Artigo em Inglês | MEDLINE | ID: mdl-37558371

RESUMO

BACKGROUND: Very few data have been published on the use of subcutaneous implantable cardioverter-defibrillators (S-ICDs) in patients with congenital heart disease (CHD). OBJECTIVES: The aim of this study was to analyze outcomes associated with S-ICDs in patients with CHD. METHODS: This nationwide French cohort including all patients with an S-ICD was initiated in 2020 by the French Institute of Health and Medical Research. Characteristics at implantation and outcomes were analyzed in patients with CHD. RESULTS: From October 12, 2012, to December 31, 2019, among 4,924 patients receiving an S-ICD implant in 150 centers, 101 (2.1%) had CHD. Tetralogy of Fallot, univentricular heart, and dextro-transposition of the great arteries represented almost one-half of the population. Patients with CHD were significantly younger (age 37.1 ± 15.4 years vs 50.1 ± 14.9 years; P < 0.001), more frequently female (37.6% vs 23.0%; P < 0.001), more likely to receive an S-ICD for secondary prevention (72.3% vs 35.9%; P < 0.001), and less likely to have severe systolic dysfunction of the systemic ventricle (28.1% vs 53.1%; P < 0.001). Over a mean follow-up period of 1.9 years, 16 (15.8%) patients with CHD received at least 1 appropriate shock, with all shocks successfully terminating the ventricular arrhythmia. The crude risk of appropriate S-ICD shock was twice as high in patients with CHD compared with non-CHD patients (annual incidences of 9.0% vs 4.4%; HR: 2.1; 95% CI: 1.3-3.4); however, this association was no longer significant after propensity matching (especially considering S-ICD indication, P = 0.12). The burden of all complications (HR: 1.2; 95% CI: 0.7-2.1; P = 0.4) and inappropriate shocks (HR: 0.9; 95% CI: 0.4-2.0; P = 0.9) was comparable in both groups. CONCLUSIONS: In this nationwide study, patients with CHD represented 2% of all S-ICD implantations. Our findings emphasize the effectiveness and safety of S-ICD in this particularly high-risk population. (S-ICD French Cohort Study [HONEST]; NCT05302115).


Assuntos
Desfibriladores Implantáveis , Cardiopatias Congênitas , Transposição dos Grandes Vasos , Humanos , Feminino , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Desfibriladores Implantáveis/efeitos adversos , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/prevenção & controle , Morte Súbita Cardíaca/etiologia , Estudos de Coortes , Resultado do Tratamento , Estudos Retrospectivos , Cardiopatias Congênitas/complicações , Cardiopatias Congênitas/terapia
3.
Heart Rhythm ; 20(2): 252-260, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36309156

RESUMO

BACKGROUND: In repaired tetralogy of Fallot (TOF), little is known about characteristics of patients with rapid ventricular tachycardia (VT). Also, whether patients with a first episode of nonrapid VT may subsequently develop rapid VT or ventricular fibrillation (VF) has not been addressed. OBJECTIVES: The objectives of this study were to compare patients with rapid VT/VF with those with nonrapid VT and to assess the evolution of VT cycle lengths (VTCLs) overtime. METHODS: Data were analyzed from a nationwide registry including all patients with TOF and implantable cardioverter-defibrillator (ICD) since 2000. Patients with ≥1 VT episode with VTCL ≤250 ms (240 beats/min) formed the rapid VT/VF group. RESULTS: Of 144 patients (mean age 42.0 ± 12.7 years; 104 [72%] men), 61 (42%) had at least 1 VT/VF episode, including 28 patients with rapid VT/VF (46%), during a median follow-up of 6.3 years (interquartile range 2.2-10.3 years). Compared with patients in the nonrapid VT group, those in the rapid VT/VF group were significantly younger at ICD implantation (35.2 ± 12.6 years vs 41.5 ± 11.2 years; P = .04), had more frequently a history of cardiac arrest (8 [29%] vs 2 [6%]; P = .02), less frequently a history of atrial arrhythmia (11 [42%] vs 22 [69%]; P = .004), and higher right ventricular ejection fraction (43.3% ± 10.3% vs 36.6% ± 11.2%; P = .04). The median VTCL of VT/VF episodes was 325 ms (interquartile range 235-429 ms). None of the patients with a first documented nonrapid VT episode had rapid VT/VF during follow-up. CONCLUSION: Patients with TOF and rapid VT/VF had distinct clinical characteristics. The relatively low variation of VTCL over time suggests a room for catheter ablation without a backup ICD in selected patients with well-tolerated VT.


Assuntos
Desfibriladores Implantáveis , Taquicardia Ventricular , Tetralogia de Fallot , Masculino , Humanos , Adulto , Pessoa de Meia-Idade , Feminino , Volume Sistólico , Tetralogia de Fallot/complicações , Tetralogia de Fallot/cirurgia , Seguimentos , Função Ventricular Direita , Taquicardia Ventricular/epidemiologia , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/terapia , Fibrilação Ventricular
5.
JACC Clin Electrophysiol ; 8(10): 1304-1314, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-36266008

RESUMO

BACKGROUND: Women with congenital heart disease at high risk for sudden cardiac death have been poorly studied thus far. OBJECTIVES: The aim of this study was to assess sex-related differences in patients with tetralogy of Fallot (TOF) and implantable cardioverter-defibrillators (ICDs). METHODS: Data were analyzed from the DAI-T4F (French National Registry of Patients With Tetralogy of Fallot and Implantable Cardioverter Defibrillator) cohort study, which has prospectively enrolled all patients with TOF with ICDs in France since 2010. Clinical events were centrally adjudicated by a blinded committee. RESULTS: A total of 165 patients (mean age 42.2 ± 13.3 years) were enrolled from 40 centers, including 49 women (29.7%). Among the 9,692 patients with TOF recorded in the national database, the proportion of women with ICDs was estimated to be 1.1% (95% CI: 0.8%-1.5%) vs 2.2% (95% CI: 1.8%-2.6%) in men (P < 0.001). The clinical profiles of patients at implantation, including the number of risk factors for ventricular arrhythmias, were similar between women and men. During a median follow-up period of 6.8 years (IQR: 2.5-11.4 years), 78 patients (47.3%) received at least 1 appropriate ICD therapy, without significant difference in annual incidences between women (12.1%) and men (9.9%) (HR: 1.22; 95% CI: 0.76-1.97; P = 0.40). The risk for overall ICD-related complications was similar in women and men (HR: 1.33; 95% CI: 0.81-2.19; P = 0.30), with 24 women (49.0%) experiencing at least 1 complication. CONCLUSIONS: Our findings suggest that women with TOF at high risk for sudden cardiac death have similar benefit/risk balance from ICD therapy compared with men. Whether ICD therapy is equally offered to at-risk women vs men warrants further evaluation in TOF as well as in other congenital heart disease populations. (French National Registry of Patients With Tetralogy of Fallot and Implantable Cardioverter Defibrillator [DAI-T4F]; NCT03837574).


Assuntos
Desfibriladores Implantáveis , Cardiopatias Congênitas , Tetralogia de Fallot , Humanos , Feminino , Masculino , Adulto , Pessoa de Meia-Idade , Desfibriladores Implantáveis/efeitos adversos , Tetralogia de Fallot/complicações , Estudos de Coortes , Caracteres Sexuais , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/prevenção & controle , Morte Súbita Cardíaca/etiologia , Cardiopatias Congênitas/complicações
6.
Circ Genom Precis Med ; 15(3): e003464, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35549293

RESUMO

BACKGROUND: Congenitally corrected transposition of the great arteries (ccTGA) is a rare disease of unknown cause. We aimed to better understand familial recurrence patterns. METHODS: An international, multicentre, retrospective cohort study was conducted in 29 tertiary hospitals in 6 countries between 1990 and 2018, entailing investigation of 1043 unrelated ccTGA probands. RESULTS: Laterality defects and atrioventricular block at diagnosis were observed in 29.9% and 9.3%, respectively. ccTGA was associated with primary ciliary dyskinesia in 11 patients. Parental consanguinity was noted in 3.4% cases. A congenital heart defect was diagnosed in 81 relatives from 69 families, 58% of them being first-degree relatives, including 28 siblings. The most prevalent defects in relatives were dextro-transposition of the great arteries (28.4%), laterality defects (13.6%), and ccTGA (11.1%); 36 new familial clusters were described, including 8 pedigrees with concordant familial aggregation of ccTGA, 19 pedigrees with familial co-segregation of ccTGA and dextro-transposition of the great arteries, and 9 familial co-segregation of ccTGA and laterality defects. In one family co-segregation of ccTGA, dextro-transposition of the great arteries and heterotaxy syndrome in 3 distinct relatives was found. In another family, twins both displayed ccTGA and primary ciliary dyskinesia. CONCLUSIONS: ccTGA is not always a sporadic congenital heart defect. Familial clusters as well as evidence of an association between ccTGA, dextro-transposition of the great arteries, laterality defects and in some cases primary ciliary dyskinesia, strongly suggest a common pathogenetic pathway involving laterality genes in the pathophysiology of ccTGA.


Assuntos
Transtornos da Motilidade Ciliar , Cardiopatias Congênitas , Transposição dos Grandes Vasos , Artérias , Transtornos da Motilidade Ciliar/complicações , Transposição das Grandes Artérias Corrigida Congenitamente , Humanos , Estudos Retrospectivos , Transposição dos Grandes Vasos/complicações , Transposição dos Grandes Vasos/diagnóstico , Transposição dos Grandes Vasos/genética
7.
Front Cardiovasc Med ; 9: 814026, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35211527

RESUMO

BACKGROUND: Compound motor action potential (CMAP) monitoring is a common method used to prevent right phrenic nerve palsy during cryoballoon ablation for atrial fibrillation. OBJECTIVE: We compared recordings simultaneously obtained with surface and hepatic electrodes. METHODS: We included 114 consecutive patients (mean age 61.7 ± 10.9 years) admitted to our department for cryoballoon ablation. CMAP was monitored simultaneously with a hepatic catheter and a modified lead I ECG, whilst right phrenic nerve was paced before (stage 1) and during (stage 2) the right-sided freezes. If phrenic threat was detected with hepatic recordings (CMAP amplitude drop >30%) the application was discontinued with forced deflation. RESULTS: The ratio of CMAP/QRS was 4.63 (2.67-9.46) for hepatic and 0.76 (0.55-1.14) for surface (p < 0.0001). Signal coefficients of variation during stage 1 were 3.92% (2.48-6.74) and 4.10% (2.85-5.96) (p = 0.2177), respectively. Uninterpretable signals were more frequent on surface (median 10 vs. 0; p < 0.0001). For the 14 phrenic threats, the CMAP amplitude dropped by 35.61 ± 8.27% on hepatic signal and by 33.42 ± 11.58% concomitantly on surface (p = 0.5417). Our main limitation was to achieve to obtain stable phrenic capture (57%). CMAP monitoring was not reliable because of pacing instability in 15 patients (13.16%). A palsy occurred in 4 patients (3.51%) because cryoapplication was halted too late. CONCLUSION: Both methods are feasible with the same signal stability and amplitude drop precocity during phrenic threats. Clarity and legibility are significantly better with hepatic recording (sharper signals, less far-field QRS). The two main limitations were pacing instability and delay between 30% CMAP decrease and cryoapplication discontinuation.

8.
Case Rep Cardiol ; 2021: 7198667, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34513094

RESUMO

Background. Anomalous left coronary artery connected to the pulmonary artery (ALCAPA) is a rare congenital heart disease. Adaptive development of sufficient heterocoronary collaterality in the newborn may allow survival to a later age. In older children or adults, malignant ventricular arrhythmias can reveal the disease. Case Report. A 15-year-old girl was referred to the local hospital after a resuscitated out-of-hospital cardiac arrest. CT scan and coronary angiography revealed an ALCAPA. Direct aortic reimplantation of the left coronary artery was performed. Postoperative ECG monitoring showed short episodes of nonsustained ventricular tachycardia. Transthoracic echocardiography and cardiac MRI revealed subendocardial fibrosis of the anterolateral papillary muscle. Beta-blockade therapy was initiated at first intention. After hospital discharge, the patient reported several fainting without loss of consciousness. Considering sudden death nonrelated to effort, episodes of nonsustained ventricular tachycardia, and areas of myocardial fibrosis, the patient underwent subcutaneous cardioverter-defibrillator implantation. 6-month follow-up is satisfactory without clinical or rhythmic abnormalities. Discussion. Indication for surgical correction of ALCAPA is well defined, but rhythmic secondary prevention after resuscitated cardiac arrest is less consensual. Cardiac MRI is an essential tool in the identification of a potential rhythmic substrate and should be taken into account in the discussion of a preventive cardioverter-defibrillator implantation.

9.
JACC Clin Electrophysiol ; 7(10): 1285-1293, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-33933408

RESUMO

OBJECTIVES: This study aimed to assess the impact of pulmonary valve replacement (PVR) on ventricular arrhythmias burden in a population of tetralogy of Fallot (TOF) patients with continuous cardiac monitoring by implantable cardioverter-defibrillators (ICDs). BACKGROUND: Sudden cardiac death is a major cause of death in TOF, and right ventricular overload is commonly considered to be a potential trigger for ventricular arrhythmias. METHODS: Data were analyzed from a nationwide French ongoing study (DAI-T4F) including all TOF patients with an ICD since 2000. Survival data with recurrent events were used to compare the burden of appropriate ICD therapies before and after PVR in patients who underwent PVR over the study period. RESULTS: A total of 165 patients (mean age 42.2 ± 13.3 years, 70.1% male) were included from 40 centers. Over a median follow-up period of 6.8 (interquartile range: 2.5 to 11.4) years, 26 patients (15.8%) underwent PVR. Among those patients, 18 (69.2%) experienced at least 1 appropriate ICD therapy. When considering all ICD therapies delivered before (n = 62) and after (n = 16) PVR, the burden of appropriate ICD therapies was significantly lower after PVR (HR: 0.21; 95% confidence interval [CI]: 0.08 to 0.56; p = 0.002). Respective appropriate ICD therapies rates per 100 person-years were 44.0 (95% CI: 35.7 to 52.5) before and 13.2 (95% CI: 7.7 to 20.5) after PVR (p < 0.001). In the overall cohort, PVR before ICD implantation was also independently associated with a lower risk of appropriate ICD therapy in primary prevention patients (HR: 0.29 [95% CI: 0.10 to 0.89]; p = 0.031). CONCLUSIONS: In this cohort of high-risk TOF patients implanted with an ICD, the burden of appropriate ICD therapies was significantly reduced after PVR. While optimal indications and timing for PVR are debated, these findings suggest the importance of considering ventricular arrhythmias in the overall decision-making process. (French National Registry of Patients With Tetralogy of Fallot and Implantable Cardioverter Defibrillator [DAI-T4F]; NCT03837574).


Assuntos
Procedimentos Cirúrgicos Cardíacos , Desfibriladores Implantáveis , Valva Pulmonar , Tetralogia de Fallot , Adulto , Arritmias Cardíacas/terapia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valva Pulmonar/cirurgia , Tetralogia de Fallot/cirurgia
10.
Circulation ; 142(17): 1612-1622, 2020 10 27.
Artigo em Inglês | MEDLINE | ID: mdl-32998542

RESUMO

BACKGROUND: Tetralogy of Fallot (TOF) is the most common cyanotic congenital heart disease, and sudden cardiac death represents an important mode of death in these patients. Data evaluating the implantable cardioverter defibrillator (ICD) in this patient population remain scarce. METHODS: A Nationwide French Registry including all patients with tetralogy of Fallot with an ICD was initiated in 2010 by the French Institute of Health and Medical Research. The primary time to event end point was the time from ICD implantation to first appropriate ICD therapy. Secondary outcomes included ICD-related complications, heart transplantation, and death. Clinical events were centrally adjudicated by a blinded committee. RESULTS: A total of 165 patients (mean age, 42.2±13.3 years, 70.1% males) were included from 40 centers, including 104 (63.0%) in secondary prevention. During a median (interquartile range) follow-up of 6.8 (2.5-11.4) years, 78 (47.3%) patients received at least 1 appropriate ICD therapy. The annual incidence of the primary outcome was 10.5% (7.1% and 12.5% in primary and secondary prevention, respectively; P=0.03). Overall, 71 (43.0%) patients presented with at least 1 ICD complication, including inappropriate shocks in 42 (25.5%) patients and lead dysfunction in 36 (21.8%) patients. Among 61 (37.0%) patients in primary prevention, the annual rate of appropriate ICD therapies was 4.1%, 5.3%, 9.5%, and 13.3% in patients with, respectively, 0, 1, 2, or ≥3 guidelines-recommended risk factors. QRS fragmentation was the only independent predictor of appropriate ICD therapies (hazard ratio, 3.47 [95% CI, 1.19-10.11]), and its integration in a model with current criteria increased the 5-year time-dependent area under the curve from 0.68 to 0.81 (P=0.006). Patients with congestive heart failure or reduced left ventricular ejection fraction had a higher risk of nonarrhythmic death or heart transplantation (hazard ratio, 11.01 [95% CI, 2.96-40.95]). CONCLUSIONS: Patients with tetralogy of Fallot and an ICD experience high rates of appropriate therapies, including those implanted in primary prevention. The considerable long-term burden of ICD-related complications, however, underlines the need for careful candidate selection. A combination of easy-to-use criteria including QRS fragmentation might improve risk stratification. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03837574.


Assuntos
Desfibriladores Implantáveis/tendências , Tetralogia de Fallot/epidemiologia , Tetralogia de Fallot/terapia , Adulto , Feminino , Seguimentos , Humanos , Masculino , Sistema de Registros
11.
Arch Cardiovasc Dis ; 113(8-9): 492-502, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32461091

RESUMO

The population of patients with congenital heart disease (CHD) is continuously increasing, and a significant proportion of these patients will experience arrhythmias because of the underlying congenital heart defect itself or as a consequence of interventional or surgical treatment. Arrhythmias are a leading cause of mortality, morbidity and impaired quality of life in adults with CHD. Arrhythmias may also occur in children with or without CHD. In light of the unique issues, challenges and considerations involved in managing arrhythmias in this growing, ageing and heterogeneous patient population and in children, it appears both timely and essential to critically appraise and synthesize optimal treatment strategies. The introduction of catheter ablation techniques has greatly improved the treatment of cardiac arrhythmias. However, catheter ablation in adults or children with CHD and in children without CHD is more technically demanding, potentially causing various complications, and thus requires a high level of expertise to maximize success rates and minimize complication rates. As French recommendations regarding required technical competence and equipment are lacking in this situation, the Working Group of Pacing and Electrophysiology of the French Society of Cardiology and the Affiliate Group of Paediatric and Adult Congenital Cardiology have decided to produce a common position paper compiled from expert opinions from cardiac electrophysiology and paediatric cardiology. The paper details the features of an interventional cardiac electrophysiology centre that are required for ablation procedures in adults with CHD and in children, the importance of being able to diagnose, monitor and manage complications associated with ablations in these patients and the supplemental hospital-based resources required, such as anaesthesia, surgical back-up, intensive care, haemodynamic assistance and imaging. Lastly, the need for quality evaluations and French registries of ablations in these populations is discussed. The purpose of this consensus statement is therefore to define optimal conditions for the delivery of invasive care regarding ablation of arrhythmias in adults with CHD and in children, and to provide expert and - when possible - evidence-based recommendations on best practice for catheter-based ablation procedures in these specific populations.


Assuntos
Arritmias Cardíacas/cirurgia , Procedimentos Cirúrgicos Cardíacos , Cardiologistas/normas , Serviço Hospitalar de Cardiologia/normas , Ablação por Cateter/normas , Competência Clínica/normas , Criocirurgia/normas , Cardiopatias Congênitas/cirurgia , Adolescente , Adulto , Fatores Etários , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/mortalidade , Arritmias Cardíacas/fisiopatologia , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/mortalidade , Ablação por Cateter/efeitos adversos , Ablação por Cateter/mortalidade , Criança , Pré-Escolar , Consenso , Criocirurgia/efeitos adversos , Criocirurgia/mortalidade , Técnicas Eletrofisiológicas Cardíacas/normas , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/mortalidade , Cardiopatias Congênitas/fisiopatologia , Frequência Cardíaca , Humanos , Lactente , Recém-Nascido , Fatores de Risco , Sobreviventes , Resultado do Tratamento , Adulto Jovem
13.
J Am Heart Assoc ; 8(9): e011172, 2019 05 07.
Artigo em Inglês | MEDLINE | ID: mdl-31057083

RESUMO

Background The natural history and long-term outcome in pediatric patients with idiopathic ventricular fibrillation ( IVF ) are poorly characterized. We sought to define the clinical characteristics and long-term outcomes of a pediatric cohort with an initial diagnosis of IVF . Methods and Results Patients were included from an International Registry of IVF (consisting of 496 patients). Inclusion criteria were: (1) VF with no identifiable cause following comprehensive analysis for ischemic, electrical or structural heart disease and (2) age ≤16 years. These included 54 pediatric IVF cases (age 12.7±3.7 years, 59% male) among whom 28 (52%) had a previous history of syncope (median 2 syncopal episodes [interquartile range 1]). Thirty-six (67%) had VF in situations associated with high adrenergic tone. During a median 109±12 months of follow-up, 31 patients (57%) had recurrence of ventricular arrhythmias, mainly VF . Two patients developed phenotypic expression of an inherited arrhythmia syndrome during follow-up (hypertrophic cardiomyopathy and long QT syndrome, respectively). A total of 15 patients had positive genetic testing for inherited arrhythmia syndromes. Ten patients (18%) experienced device-related complications. Three patients (6%) died, 2 due to VF storm. Conclusions In pediatric patients with IVF , a minority develop a definite clinical phenotype during long-term follow-up. Recurrent VF is common in this patient group.


Assuntos
Fibrilação Ventricular/fisiopatologia , Adolescente , Miosinas Cardíacas/genética , Cardiomiopatia Hipertrófica Familiar/diagnóstico , Criança , Desfibriladores Implantáveis , Eletrocardiografia , Feminino , Humanos , Síndrome do QT Longo/diagnóstico , Estudos Longitudinais , Masculino , Cadeias Pesadas de Miosina/genética , Canal de Sódio Disparado por Voltagem NAV1.5/genética , Fenótipo , Recidiva , Canal de Liberação de Cálcio do Receptor de Rianodina/genética , Síncope , Taquicardia Ventricular/epidemiologia , Fibrilação Ventricular/genética , Fibrilação Ventricular/mortalidade , Fibrilação Ventricular/terapia
14.
Purinergic Signal ; 15(1): 45-52, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30535950

RESUMO

The mechanism of atrial fibrillation (AF) in patients with normal heart remains unclear. While exogenous adenosine can trigger AF, nothing is known about the behavior of endogenous adenosine plasma level (APL) at the onset of AF and during ablation procedure. Ninety-one patients (68 with paroxysmal AF: 40 males, 66 ± 16 years; 23 with persistent AF: 14 males, 69 ± 11 years) and 18 controls were included. Among paroxysmal patients: i) medical therapy alone was performed in 45 cases and ablation procedure in 23. AF was spontaneously resolutive in 6 cases; ii) 23 underwent ablation procedure and blood was collected simultaneously in a brachial vein and in the left atrium; 17 were spontaneously in sinus rhythm while 6 were in sinus rhythm after direct current cardioversion. Among persistent patients: i) in 17 patients, blood samples were collected in a brachial vein before and after direct current cardioversion; ii) in 6 patients, blood samples were collected simultaneously in a brachial vein and in left atrium before and after cardioversion during ablation procedure. CV-APL was higher in patients with persistent AF vs patients with paroxysmal AF (median [range]: 0.9[0.6-1.1] vs 0.7[0.4-1.1] µM; p < 0.001). In patients with paroxysmal AF, LA-APL increased during the AF episode (0.95[0.85-1.4] vs 2.7[1.5-7] µM; p = 0.03) and normalized in sinus rhythm after DCCV. In patients with persistent AF, LA-APL was higher than CV-APL (1.2[0.7-1.8] vs 0.9[0.6-1.1] µM; p < 0.001), and both normalized in sinus rhythm (CV-APL: 0.8[0.6-1.1] vs 0.75[0.4-1] µM; p = 0.03), (LA-APL: 1.95[1.3-3] vs 1[0.5-1.15] µM; p = 0.03). The occurrence of AF is associated with a strong increase of APL in the atrium. The cause of this increase needs further investigations.


Assuntos
Adenosina/sangue , Fibrilação Atrial/sangue , Idoso , Fibrilação Atrial/terapia , Ablação por Cateter , Cardioversão Elétrica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
15.
Heart Vessels ; 34(5): 824-831, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30415372

RESUMO

Infections of cardiac implantable electronic devices (CIEDs) have increased over the past decade. However, the impact of the climate on CIED infections is unknown. To determine whether there is a seasonal variation in CIED infections. In this single-center observational study, retrospective analysis of prospectively collected data was performed. Timone Hospital in Marseille (south-east France) is a tertiary care institution and the regional reference center for management of CIED infections. All consecutive patients with CIED extractions for infectious reasons were included over a 12-year period. We noted the mean temperature (°C), precipitation (mm) and the incidence of CIED infections over this period. Among 612 patients [mean (standard deviation) age, 72.4 (13.0) years; 74.0% male], 238 had endocarditis alone (38.9%), 249 had pocket infection alone (40.7%), and 125 had both (20.4%). We found bacterial documentation in 428 patients (70.0%), commensal in 245 (40.0%). The incidence of CIED infections was positively associated with high temperature (regression coefficient = 0.075; P = 0.01) and precipitation (regression coefficient = 0.022; P < 0.01). Seasonal variation was specific of pocket infections, whether they were associated with endocarditis or not. Subgroups with infection seasonality were: women, elderly people (> 75 years), late CIED infection and skin commensal bacterial infections. We found a seasonal variation in pocket infections, whether associated with endocarditis or not. Infections were associated with elevated temperatures and precipitation. Therefore, specific prevention strategy should be discussed in high-risk patients.


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Marca-Passo Artificial/efeitos adversos , Infecções Relacionadas à Prótese/epidemiologia , Infecções Relacionadas à Prótese/etiologia , Estações do Ano , Idoso , Idoso de 80 Anos ou mais , Endocardite/epidemiologia , Endocardite/etiologia , Feminino , França/epidemiologia , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Centros de Atenção Terciária
16.
Pacing Clin Electrophysiol ; 41(9): 1071-1077, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29947109

RESUMO

PURPOSE: Ablation of premature ventricular complexes (PVCs) originating from left-sided papillary muscles is challenging. We tested a new approach by performing high-density mapping of PVC. METHODS AND RESULTS: We used a 20-pole deflectable spiral catheter during ablation procedures in four consecutive patients. Three presented with mitral valve prolapse, one with dilated cardiomyopathy. PVC burden was 24 ± 13%. The procedures lasted 182 ± 55.4 minutes, including 10 ± 3.2 minutes of radiofrequency. In all patients, mapping evidenced internal primary activation relative to the left ventricle shell (mean distance 21.3 ± 5.1 mm). Endocavitary prematurity was -38.3 ± 4.8 ms. Primary ablation success was achieved for all patients. CONCLUSIONS: High-density mapping of the papillary muscles in the left ventricle using a spiral catheter may be feasible. We identified the PVC foci away from the left ventricular shell. This consolidates the assumption for the origin of these ectopic beats at the junction between the chordae tendineae and the papillary muscles.


Assuntos
Músculos Papilares/cirurgia , Ablação por Radiofrequência/métodos , Complexos Ventriculares Prematuros/cirurgia , Cardiomiopatia Dilatada/fisiopatologia , Cardiomiopatia Dilatada/cirurgia , Ecocardiografia , Eletrocardiografia Ambulatorial , Mapeamento Epicárdico , Feminino , Fluoroscopia , Humanos , Masculino , Pessoa de Meia-Idade , Prolapso da Valva Mitral/fisiopatologia , Prolapso da Valva Mitral/cirurgia , Músculos Papilares/fisiopatologia , Resultado do Tratamento , Complexos Ventriculares Prematuros/fisiopatologia
17.
Europace ; 20(4): e42-e50, 2018 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-28582500

RESUMO

Aims: Reimplantation of cardiac implantable electronic devices (CIEDs) after extraction due to device infection is a major issue in pacemaker-dependent patients. We compared in-hospital and long-term outcomes with two techniques: epicardial reimplantation (EPI) before CIED extraction and temporary pacing (TP) with a view to delayed endocardial reimplantation. Methods and results: Two cohorts of consecutive pacemaker-dependent patients who underwent transvenous lead extraction at our tertiary centre were included in this retrospective cohort study. According to successive policies, either the EPI or the TP approach was used. In-hospital complications occurred at similar rates in the EPI (n = 59) and TP (n = 52) cohorts (37.3% vs. 32.7%, respectively; P = 0.61). Thirteen (25.0%) patients in the TP cohort eventually were reimplanted epicardially, mainly because of infection of the temporary lead. Finally, 65 patients were discharged with an epicardial device and 37 with an endocardial device. Median follow-up was 41.7 (interquartile range 34.1-51.5) months. No difference was observed in long-term mortality according to the reimplantation strategy, but use of TP was associated with a reduced risk of late endocarditis and device reintervention (hazard ratio (HR) 0.25, 95% confidence interval (CI) 0.09-0.069, P = 0.01), whereas epicardial device reimplantation was associated with an increased risk (HR 3.62, 95% CI 1.07-12.21, P = 0.04). Conclusion: We observed similar in-hospital outcomes in our EPI and TP cohorts. Twenty-five percent of the patients initially paced by a TP strategy finally needed an epicardial device, mainly because of infection of their TP lead. Use of TP resulted in lower rates of late endocarditis and device reintervention.


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo , Endocárdio/cirurgia , Marca-Passo Artificial/efeitos adversos , Pericárdio/cirurgia , Implantação de Prótese/métodos , Infecções Relacionadas à Prótese/cirurgia , Estimulação Cardíaca Artificial , Endocárdio/fisiopatologia , Hospitalização , Humanos , Pericárdio/fisiopatologia , Implantação de Prótese/efeitos adversos , Implantação de Prótese/instrumentação , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/microbiologia , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
18.
Pacing Clin Electrophysiol ; 41(5): 444-446, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29148059

RESUMO

Early repolarization (ER) has been associated with an increased risk of sudden cardiac arrest. Interestingly, ventricular arrhythmias seem to be triggered by parasympathetic stimulation. In the present case report, we describe complete control of highly frequent malignant ventricular arrhythmias after adding theophylline to ineffective oral hydroquinidine and high-rate pacing in a patient suffering from malignant ER. We hypothesize that the theophylline-mediated enhanced beta-adrenergic stimulation could reduce the transmural myocardial voltage discrepancy by increasing the inward ICa,L current.


Assuntos
Desfibriladores Implantáveis , Taquicardia Ventricular/tratamento farmacológico , Teofilina/uso terapêutico , Vasodilatadores/uso terapêutico , Antiarrítmicos/uso terapêutico , Criança , Disopiramida/uso terapêutico , Humanos , Masculino , Quinidina/análogos & derivados , Quinidina/uso terapêutico , Recidiva , Taquicardia Ventricular/fisiopatologia
19.
Heart Lung Circ ; 27(8): 984-988, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28969980

RESUMO

BACKGROUND: The wearable cardioverter defibrillator (WCD) is a life-saving therapy in patients with high risk of arrhythmic death. We aimed to evaluate ventricular arrhythmia (VA) occurrence rate and compliance with the WCD during the first 90 days following myocardial revascularisation with percutaneous coronary intervention (PCI) in patients with left ventricular ejection fraction (LVEF) <30%. METHODS: From September 2015 to November 2016, clinical characteristics, WCD recordings and compliance data of the aforementioned subset of patients were prospectively collected. RESULTS: Twenty-four patients (men=20, 80%) were included in this analysis. Mean age was 56±10 years and mean LVEF at enrolment was 26.6±4.3%. During a mean wearing period of 3.0±1.3 months, two episodes of VA occurred in two patients (8.3%): one successfully treated with WCD shock and one with spontaneous termination. The mean and median daily use of the WCD was 21.5hours and 23.5hours a day, respectively. Eighteen patients (75%) wore the WCD more than 22hours a day. CONCLUSIONS: The rate of VA, during the WCD period use after myocardial revascularisation with PCI, was high in our study. Otherwise it underlined that patient compliance is critical during the WCD period use. Remote monitoring and patient education are keys to achieve good compliance.


Assuntos
Morte Súbita Cardíaca/prevenção & controle , Cardioversão Elétrica/instrumentação , Cooperação do Paciente , Intervenção Coronária Percutânea/efeitos adversos , Complicações Pós-Operatórias/etiologia , Taquicardia Ventricular/etiologia , Dispositivos Eletrônicos Vestíveis , Eletrocardiografia , Feminino , França/epidemiologia , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/terapia , Estudos Retrospectivos , Taquicardia Ventricular/epidemiologia , Taquicardia Ventricular/terapia , Função Ventricular Esquerda/fisiologia
20.
J Interv Card Electrophysiol ; 49(2): 191-196, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28536837

RESUMO

PURPOSE: Subcutaneous implantable cardioverter defibrillator (S-ICD) is an alternative to transvenous ICD to prevent sudden cardiac death. Subcutaneous ICD implantation frequently requires general anesthesia because of procedure nociceptive steps during creation of a large device pocket and lead tunneling. This study aims to determine if a strategy of operator-guided controlled sedation with midazolam and analgesia with nalbuphine is effective in alleviating pain during S-ICD implantation. METHODS: This prospective study included consecutive patients undergoing S-ICD implantation under controlled sedation with midazolam and combined analgesia with nalbuphine. The Critical-Care Pain Observation Tool (CPOT), a behavioral pain scale, was used for pain assessment during S-ICD placement and the Numeric Rate Scale (NRS) was used for evaluation of pain recollection after patient recovery. CPOT score of 3 or above and NRS score of 4 or above are considered to be associated with significant pain. RESULTS: Sixteen patients were included in this study: Ten men (62.5%) and six women with a mean age of 54 ± 11 years. Indication for S-ICD implantation was primary prevention in 11 patients (68.8%). Mean dose of administrated midazolam and nalbuphine was 0.11 ± 0.03 and 0.27 ± 0.05 mg/kg, respectively. Mean CPOT during the whole procedure was 1.4 ± 1.6. No patient presented procedural pain recollection as all 16 patients had NRS score less than 4. No serious adverse event related to sedation occurred during S-ICD implantation. CONCLUSIONS: This study suggests that operator-guided controlled sedation with midazolam and analgesia with nalbuphine is effective to alleviate procedural pain in patients undergoing S-ICD implantation and may constitute an alternative to general anesthesia.


Assuntos
Analgésicos Opioides/uso terapêutico , Desfibriladores Implantáveis , Hipnóticos e Sedativos/uso terapêutico , Midazolam/uso terapêutico , Nalbufina/uso terapêutico , Manejo da Dor/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Medição da Dor , Estudos Prospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...