Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
Electrophoresis ; 22(19): 4104-17, 2001 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-11824631

RESUMO

A number of significant improvements in the electrophoretic performance and design of DNA sequencing devices have culminated in the introduction of truly industrial grade production scale instruments. These instruments have been the workhorses behind the massive increase in genomic sequencing data available in public and private databases. We highlight the recent progress in aspects of capillary electrophoresis (CE) that has enabled these achievements. In addition, we summarize recent developments in the use of microfabricated devices for DNA sequencing that promise to bring the next leap in productivity.


Assuntos
Eletroforese Capilar/métodos , Análise de Sequência de DNA/métodos
3.
Anal Chem ; 72(14): 3129-37, 2000 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-10939377

RESUMO

We have examined the parametric performance of short microfabricated electrophoresis devices that operate with a replaceable linear poly(acrylamide) (LPA) solution for the application of DNA sequencing. A systematic study is presented of the dependence of selectivity, separation efficiency, and resolution of sequencing fragments on buffer composition, LPA concentration, LPA composition, microdevice temperature, electric field, and device length. A specific optimization is made for DNA sequencing on 11.5-cm devices. Using a separation matrix composed of 3.0% (w/w) 10 MDa plus 1.0% (w/w) 50 kDa LPA, elevated microdevice temperature (50 degrees C), and 200 V/cm, high-speed DNA sequencing of 580 bases on standard M13mp18 was obtained in only 18 min with a base-calling accuracy of 98.5%. Read lengths of 640 bases at 98.5% accuracy were achieved in approximately 30 min by reducing the electric field strength to 125 V/cm. We believe that this constitutes matrix-limited performance for microdevices of this length using LPA sieving matrix and this buffer chemistry. In addition, it was confirmed, that shorter devices are rather impractical for production sequencing applications when LPA is used as sieving matrix.


Assuntos
DNA/análise , Análise de Sequência de DNA/métodos , Sequência de Bases , Soluções Tampão , Eletroforese Capilar , Eletroforese em Gel de Poliacrilamida , Dados de Sequência Molecular
4.
Anal Chem ; 72(14): 3388-91, 2000 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-10939418

RESUMO

The human genome will be sequenced using capillary array electrophoresis technology. Although currently achieving only 550 base reads per run, capillary arrays have increased the efficiency and lowered the cost of sequencing by eliminating gel plate preparation, reducing sample volumes, and offering automation and speed. However, much higher throughput and greater cost reductions are needed. The next major advancement in sequencing technology is expected from the development of arrays of microfabricated channels in a plate or "chip" format. For de novo sequencing, the practical utility of the microdevice approach has been limited by device length to a read of 500-600 bases per run. We demonstrate a significant milestone for a microfabricated device by obtaining an average read length of 800 bases in 80 min (98% accuracy) for either M13 standards or DNA sequencing samples from the Whitehead Institute Center for Genomic Research (WICGR) production line. This result is achieved in 40-cm-long channels using a new class of large-scale microfabricated devices. Both microfabrication of extended structures and achievement of long reads are essential steps toward a 384-lane very-large-scale microfluidic (VLSMF) system for ultrahigh-throughput DNA sequencing analysis, currently under construction in our laboratory.


Assuntos
DNA/análise , Eletroforese Capilar/instrumentação , Análise de Sequência de DNA/instrumentação , Sequência de Bases , Humanos , Miniaturização , Dados de Sequência Molecular
5.
Nucleic Acids Res ; 28(9): E43, 2000 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-10756210

RESUMO

As a trial practical application, we have applied optimized microfabricated electrophoresis devices, combined with enzymatic mutation detection methods, to the determination of single nucleotide polymorphism (SNP) sites in the p53 suppressor gene. Using clinical samples, we have achieved robust assays with quality factors as good as conventional electrophoresis in approximately 100 s. This is 10 and 50 times faster than capillary and slab gel electro-phoresis, respectively. The method was highly accurate with an average error of mutation site measurement of only +/-5 bp. No clean-up of the digestion mixtures was needed prior to injection. This greatly simplifies sample handling relative to capillary instruments, which is important for high-throughput screening applications. Following identification, absolute mutation determination of the screened samples was achieved in a second microdevice optimized for four-color DNA sequencing. Total run time was 25 min in this second device and sequencing data were in full agreement with ABI Prism 377 sequencing runs which required 3.5 h. The tandem application of microdevices for location then full characterization of SNPs appears to confirm many of the improvements claimed for future application of microdevices in practical scaled screening for mutational analysis.


Assuntos
Análise Mutacional de DNA/métodos , Eletroforese em Gel de Poliacrilamida/métodos , Análise de Sequência com Séries de Oligonucleotídeos , Polimorfismo de Nucleotídeo Único , DNA Complementar , Endodesoxirribonucleases/metabolismo , Genes p53 , Humanos , Técnicas In Vitro , Miniaturização , Reprodutibilidade dos Testes , Análise de Sequência de DNA/métodos
6.
Electrophoresis ; 20(15-16): 3066-77, 1999 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-10596815

RESUMO

The present review covers papers published in the years 1997 and 1998 on DNA sequencing by capillary and microdevice electrophoresis. The article does not include other electrophoretic DNA applications such as analysis of oligonucleotides, genotyping, and mutational analysis. Capillary gel electrophoresis (CGE) is starting to become a viable competitor to slab gel electrophoresis for DNA sequencing. Commercially available multicapillary array sequencers are now entering sequencing facilities which to date have totally relied on traditional slab gel technology. CGE research on DNA sequencing therefore becomes increasingly concerned with the critical task of fine-tuning the operational parameters to create robust sequencing systems. Electrophoretic microdevices are being considered the next technological step in DNA sequencing by electrophoresis.


Assuntos
DNA/análise , Eletroforese Capilar/métodos , Análise de Sequência de DNA/métodos , Corantes/química , Eletroforese Capilar/instrumentação , Eletroforese Capilar/tendências , Análise de Sequência de DNA/instrumentação , Análise de Sequência de DNA/tendências
7.
Genome Res ; 9(9): 853-8, 1999 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-10508844

RESUMO

We report results using a microdevice for DNA sequencing using samples from chromosome 17, obtained from the Whitehead Institute Center for Genome Research (WICGR) production line. The device had an effective separation distance of 11.5 cm and a lithographically defined injection width of 150 microm. The four-color raw data were processed, base-called by the sequencing software Trout, and compared to the corresponding ABI 377 sequence from WICGR. With a criteria of 99% accuracy, we achieved average continuous reads of 505 bases in 27 min with 3% linear polyacrylamide (LPA) at 150 V/cm, and 460 bases in 22 min with 4% LPA at 200 V/cm at a temperature of 45 degrees C. In the best case, up to 565 bases could be base-called with the same accuracy in <25 min. In some instances, Trout allowed for accurate base-calling down to a resolution R as low as R = 0.35. This may be due in part to the high signal-to-noise ratio of the microdevice. Unlike many results reported on capillary machines, no additional sample cleanup other than ethanol precipitation was required. In addition, DNA fragment biasing (i.e., discrimination against larger fragments) was reduced significantly through the unique sample injection mechanism of the microfabricated device. This led to increased signal strength for long fragments, which is of great importance for the high performance of the microdevice.


Assuntos
Eletroforese Capilar/instrumentação , Eletroforese Capilar/métodos , Eletroforese em Gel de Poliacrilamida/instrumentação , Eletroforese em Gel de Poliacrilamida/métodos , Sequência de Bases , Cromossomos Humanos Par 17 , Projeto Genoma Humano , Humanos , Dados de Sequência Molecular , Reprodutibilidade dos Testes , Análise de Sequência de DNA/métodos
8.
Anal Biochem ; 270(1): 148-52, 1999 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-10328776

RESUMO

Single-channel microfabricated electrophoretic devices equipped with a dual-wavelength laser-induced fluorescence detection system were used for the fast analysis of an eight-loci, two-color multiplex short tandem repeat (STR) system for human identification. Routine analyses of the eight loci (CSF1PO, TPOX, TH01, vWA and D16S539, D7S820, D13S317, D5S818), requiring four-base resolution, were performed in only 2 min. Specific analyses for a microvariant allele (allele 9.3 of the TH01 locus) demanded single-base resolution and was performed in less than 10 min. The high accuracy of the microdevice for real-world STR sample analyses was demonstrated by comparison with conventional slab-gel electrophoresis. Our results show that a fast multiwavelength multichannel electrophoretic microsystem will be capable of routinely processing thousands of complex STR samples per day.


Assuntos
Eletroforese/instrumentação , Sequências de Repetição em Tandem , Cor , Eletroforese/métodos , Humanos
9.
Anal Chem ; 70(11): 2303-10, 1998 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-9624902

RESUMO

We present a model that quantitatively describes the performance of microfabricated electrophoretic devices filled with linear polyacrylamide as replaceable sieving material for single-stranded DNA analyses. The dependence of resolution on various separation parameters such as selectivity, diffusion, injector size, device length, and channel folding was investigated. A previously predicted dependence of longitudinal diffusion coefficient on electric field strength has been verified. We have used this model to develop and optimize microfabricated electrophoretic devices for DNA analyses. For single-color DNA sequencing mixtures, we routinely achieve separations of 400 bases in under 14 min at 200 V/cm, and separation of 350 bases in only 7 min at 400 V/cm, with a minimum resolution of R = 0.5. Our results also indicate reduced fragment biasing and efficient sample stacking for DNA sample loading on microfabricated devices.


Assuntos
DNA de Cadeia Simples/análise , DNA de Cadeia Simples/química , Eletroforese Capilar/métodos , Resinas Acrílicas/química , Fragmentação do DNA , Difusão , Campos Eletromagnéticos , Dióxido de Silício/química , Espectrometria de Fluorescência
10.
J Chromatogr B Biomed Sci Appl ; 697(1-2): 175-80, 1997 Sep 12.
Artigo em Inglês | MEDLINE | ID: mdl-9342667

RESUMO

As part of our ongoing effort to develop electrophoretic assay technology for clinical diagnostics, we describe a competitive immunoassay for the determination of serum thyroxine (T4) based on electrophoresis and laser induced fluorescence (LIF). Measurements of total T4 are useful for the clinical evaluation of thyroid function. A fluorescein thyroxine conjugate was utilized in conjunction with a polyclonal antibody preparation as assay reagents. Capillary electrophoresis (CE) conditions tolerant of the direct injection of serum without extraction or other sample preparation steps were developed and used for quantitation of total T4 in serum. We have been exploring the use of micromachined devices with arrays of channels for high assay throughput. Our assay protocol was carried in a microchip format. The results illustrate that gains in speed can be additionally achieved, with the electrophoretic separation of free from bound labelled T4 being performed in about 15 s for serum samples.


Assuntos
Tiroxina/sangue , Eletroforese Capilar/instrumentação , Humanos , Imunoensaio/métodos
11.
Proc Natl Acad Sci U S A ; 94(19): 10273-8, 1997 Sep 16.
Artigo em Inglês | MEDLINE | ID: mdl-9294200

RESUMO

We report the development of a practical ultrafast allelic profiling assay for the analysis of short tandem repeats (STRs) by using a highly optimized microfluidic electrophoresis device. We have achieved baseline-resolved electrophoretic separations of single-locus STR samples in 30 sec. Analyses of PCR samples containing the four loci CSF1PO, TPOX, THO1, and vWA (abbreviated as CTTv) were performed in less than 2 min. This constitutes a 10- to 100-fold improvement in speed relative to capillary or slab gel systems. The separation device consists of a microfabricated channel 45 micron x 100 micron in cross section and 26 mm in length, filled with a replaceable polyacrylamide matrix operated under denaturing conditions at 50 degrees C. A fluorescently labeled STR ladder was used as an internal standard for allele identification. Samples were prepared by standard procedures and only 4 microl was required for each analysis. The device is capable of repetitive operation and is suitable for automated high-speed and high-throughput applications.


Assuntos
DNA/genética , Técnicas Genéticas , Genoma Humano , Eletroforese em Gel de Poliacrilamida/métodos , Humanos , Reação em Cadeia da Polimerase , Sequências Repetitivas de Ácido Nucleico , Robótica
12.
Anal Chem ; 68(1): 18-22, 1996 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-8779431

RESUMO

An immunoassay performed using a microchip electrophoretic system is described. Separation and quantitation of free and bound labeled antigen in a competitive assay are carried out in channels micromachined into fused silica substrates. Such microchips are attractive because of their small size, ruggedness, and amenability to automated handling. The assay achieves the determination of cortisol in blood serum over the range of clinical interest (1-60 micrograms/dL) without the need for extraction or other sample preparation steps. The separation is performed in less than 30 s. Very high throughput is possible by operating the assay in multiple channels in parallel. These characteristics make microchip electrophoretic systems a promising technology for the rapid analysis of clinical samples.


Assuntos
Eletroforese/instrumentação , Hidrocortisona/sangue , Imunoensaio/instrumentação , Humanos , Indicadores e Reagentes
13.
Anal Chem ; 65(2): 148-52, 1993 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-8430894

RESUMO

Normally, data acquisition and processing in chemical measurements are based on equal time (effort) for each data point. This leads to uneven signal-to-noise ratios (S/N) for each point. We present an expert system which decides in real time whether adequate S/N has been achieved for each point. If so, that data point will be omitted in all further acquisition or processing operations, greatly increasing the overall efficiency. The special case of analyzing DNA sequencing gels is tested with this scheme. A factor of 7.6 reduction in effort is demonstrated for a data set of 384 x 250 pixels, which normally would require 6 million sequential operations (64 frames).


Assuntos
Sequência de Bases , DNA/química , Sistemas Inteligentes
SELEÇÃO DE REFERÊNCIAS