Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Bone Joint Surg Br ; 93(11): 1487-92, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22058299

RESUMO

We report the long-term results of the management of neglected chronically infected total knee replacements with a two-stage re-implantation protocol. In 18 of 34 patients (53%) a resistant organism was isolated. All cases were treated by the same surgical team in a specialist centre and had a mean follow-up of 12.1 years (10 to 14). They were evaluated clinically and radiologically using the Knee Society Score (KSS) and the American Knee Society Roentgenographic scoring system, respectively. One patient died after eight years from an unrelated cause and two were lost to follow-up. Three patients (8.8%) developed a recurrent infection for which further surgery was required. The infection was eradicated successfully in 31 patients (91.1%). There was one case of aseptic loosening after 13 years. We found a significant improvement in the KSS at final follow-up (p < 0.001).


Assuntos
Artroplastia do Joelho/métodos , Prótese do Joelho/efeitos adversos , Infecções Relacionadas à Prótese/cirurgia , Adulto , Antibacterianos/uso terapêutico , Doença Crônica , Terapia Combinada , Resistência Microbiana a Medicamentos , Feminino , Seguimentos , Humanos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/fisiopatologia , Masculino , Pessoa de Meia-Idade , Osteoartrite do Joelho/cirurgia , Falha de Prótese , Infecções Relacionadas à Prótese/diagnóstico por imagem , Infecções Relacionadas à Prótese/tratamento farmacológico , Infecções Relacionadas à Prótese/etiologia , Radiografia , Amplitude de Movimento Articular , Recidiva , Resultado do Tratamento
2.
J Bone Joint Surg Br ; 92(5): 624-8, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20435996

RESUMO

Between November 1997 and December 2000 we performed 27 total hip replacements in 22 patients with high congenital dislocation of the hip using porous tantalum monoblock acetabular components implanted in the true acetabular bed. Clinical and radiological evaluation was performed at regular intervals for a mean of 10.2 years (8.5 to 12). The mean Harris Hip Score improved from 48.3 (15 to 65) pre-operatively to 89.5 (56 to 100) at the final follow-up. The mean Oxford Hip Score was 49.5 (35 to 59) pre-operatively and decreased to 21.2 (12 to 48) at one year and 15.2 (10 to 28) at final follow-up. Migration of the acetabular component was assessed with the EBRA software system. There was a mean migration of 0.68 mm (0.49 to 0.8) in the first year and a mean 0.89 mm (0.6 to 0.98) in the second year, after excluding one initial excessive migration. No revision was necessary for any reason, no acetabular component became loose, and no radiolucent lines were observed at the final follow-up. The porous tantalum monoblock acetabular component is an implant offering adequate initial stability in conjunction with a modulus of elasticity and porosity close to that of cancellous bone. It favours bone ingrowth, leading to good mid-term results.


Assuntos
Acetábulo/cirurgia , Artroplastia de Quadril/métodos , Luxação Congênita de Quadril/cirurgia , Prótese de Quadril , Tantálio , Acetábulo/diagnóstico por imagem , Adulto , Artroplastia de Quadril/instrumentação , Materiais Biocompatíveis , Desenho de Equipamento , Feminino , Fricção , Luxação Congênita de Quadril/diagnóstico por imagem , Luxação Congênita de Quadril/fisiopatologia , Articulação do Quadril , Humanos , Complicações Intraoperatórias , Desigualdade de Membros Inferiores , Pessoa de Meia-Idade , Porosidade , Estudos Prospectivos , Radiografia , Índice de Gravidade de Doença , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA