Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Org Chem ; 88(8): 5172-5179, 2023 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-37052371

RESUMO

Palladium-catalyzed amino- and alkoxycarbonylation reactions of aryl iodides were investigated in the presence of aliphatic heterobifunctional N,O-nucleophiles. Selective synthesis of amide alcohols and amide esters was realized, controlled by the base and substrate ratio. The effect of iodobenzene substituents was also studied with surprising results in terms of product selectivity. In addition to the model ethanolamine/iodobenzene system, various heteroaromatic substrates and numerous related nucleophiles were tested under optimized conditions, providing moderate to good yields of the target compounds. Reactions of serinol and 1,3-diamino-2-propanol as model trifunctional compounds showed particularly high chemoselectivity on amide ester products. Considering the coordinative properties of the applied nucleophiles, a rational catalytic cycle was proposed.

2.
Am J Perinatol ; 38(8): 841-847, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-31986539

RESUMO

OBJECTIVE: This study aimed to perform a systematic review with meta-analysis to investigate if women with a low 50-g, 1-hour glucose challenge test (GCT) value are at risk for having neonates with a birth weight less than the 10th percentile. STUDY DESIGN: A computerized literature search was conducted to identify studies that compared outcomes of pregnant women with a low GCT value versus women with a normal GCT value during routine screening for gestational diabetes. RESULTS: Sixteen cohort studies were included for analysis. Women with a low GCT value were noted to have a 43% increased odds of having neonates with birth weight less than the 10th percentile (odds ratio [OR]: 1.43; 95% confidence interval [CI]: 1.28-1.60) and 30% increased odds of having neonates with a birth weight less than 2,500 g (OR: 1.3; 95% CI: 1.0-1.7) when compared with women with a normal GCT value. The rates of preterm delivery, neonatal intensive care unit (NICU) admission, pregnancy-induced hypertension (PIH)/preeclampsia, respiratory distress, NICU, and Apgar scores less than 7 were similar in the two groups. CONCLUSION: A low GCT value defined as less than 90 mg/dL identifies pregnancies at elevated risk for having neonates with a birth weight less than the 10th percentile.


Assuntos
Glicemia/análise , Hipoglicemia , Recém-Nascido de Baixo Peso , Complicações na Gravidez , Gravidez/sangue , Feminino , Teste de Tolerância a Glucose , Humanos , Hipoglicemia/diagnóstico , Recém-Nascido , Complicações na Gravidez/diagnóstico , Fatores de Risco
3.
Am J Obstet Gynecol ; 221(3): 261.e1-261.e20, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-30954518

RESUMO

BACKGROUND: Direct comparison metaanalyses have reported benefits with presurgical vaginal preparation before cesarean delivery for the reduction of endometritis. These reports did not perform a multitreatment comparison of the various antiseptic solutions assessed in previous studies. OBJECTIVE: The purpose of this study was to review the literature systematically and quantitate and summarize indirectly the comparative efficacy of antiseptic formulations and their concentrations that are used for the preparation of the vagina before cesarean delivery in the prevention of endometritis and other infectious complications. STUDY DESIGN: We used MEDLINE, EMBASE (from their inception to November 2018) and Cochrane databases, biographies, and conference proceedings. We used randomized clinical trials of patients who underwent surgical preparation of the vagina with antiseptic formulations before cesarean delivery with the aim of reducing the risk of infectious morbidity. Our systematic review was registered and followed the Preferred Reporting Items for Systematic Review and Meta-analysis Extension for network meta-analysis guidelines. Network meta-analysis was performed with computerized software and used user-written programs to assess consistency, inconsistency, ranking probabilities, and graphing results. Direct and indirect pairwise comparisons of the various formulations and their concentrations were performed with the use of multivariate random-effects models and metaregression. A frequentist inference method was employed for the fitted model to estimate the ranking probabilities. Subgroup analyses for patients in labor, not in labor, and with ruptured membranes were conducted. RESULTS: For the prevention of endometritis, we identified 23 studies that comprised 7097 women who were allocated to the following treatments: povidone-iodine (1%, 5%, 10%), chlorhexidine (0.2%, 0.4%), metronidazole gel, cetrimide, or normal saline solution/no treatment. Direct and indirect pairwise comparisons indicated that, when compared with saline solution or no treatment, all antiseptic formulations decreased rates of endometritis (5.2% vs 9.1%; odds ratio, 0.48; 95% confidence interval, 0.35-0.65; 22 studies/6994 women). Individually, povidone-iodine (odds ratio, 0.43; 95% confidence interval, 0.28-0.64; 16 studies/5968 women), cetrimide (odds ratio, 0.34; 95% confidence interval, 0.13-0.90; 1 study/200 women), and metronidazole (odds ratio, 0.38; 95% confidence interval, 0.16-0.90; 1 study/224 women) significantly reduced the risk of endometritis. Rankings of vaginal preparations indicated that povidone-iodine 1% had the highest probability (72.7%) of being the most effective treatment for the prevention of endometritis. For the secondary outcomes of postoperative wound infection and fever, a significant reduction was found only with povidone-iodine (odds ratio, 0.61; 95% confidence interval, 0.48-0.78; 16 studies/5968 women; and odds ratio, 0.58; 95% confidence interval, 0.40-0.83; 12 studies/4667 women). Subgroup analyses also found that povidone-iodine significantly reduced risk of endometritis for women in labor (odds ratio, 0.42; 95% confidence interval, 0.20-0.88; 5 studies/1211 women), with ruptured membranes(odds ratio, 0.21; 95% confidence interval, 0.10-0.44; 4 studies/476 women), and undergoing planned cesarean delivery (odds ratio, 0.39; 95% confidence interval, 0.27-0.57; 8 studies/1825 women). CONCLUSION: Among patients who underwent cesarean delivery, presurgical vaginal irrigation with povidone-iodine had the highest probability of reducing the risk of endometritis, postoperative wound infections, and fever.


Assuntos
Anti-Infecciosos Locais/uso terapêutico , Cesárea , Endometrite/prevenção & controle , Povidona-Iodo/uso terapêutico , Cetrimônio/uso terapêutico , Clorexidina/uso terapêutico , Feminino , Humanos , Metronidazol/uso terapêutico , Metanálise em Rede
4.
Am J Obstet Gynecol ; 220(2): 183.e1-183.e8, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30419198

RESUMO

BACKGROUND: Intrauterine devices are currently one of the leading forms of reversible contraception in the world. However, in approximately 10-25% of women, intrauterine devices can become malpositioned, leading to consequences including pain, bleeding, as well as possible decreased contraceptive efficacy. OBJECTIVE: We sought to determine whether certain reproductive and uterine characteristics are associated with an increased risk of intrauterine device malposition. We hypothesized that anatomical characteristics such as the presence of any uterine anomalies, particularly congenital anomalies and fibroids that may lead to cavitary distortion, would be associated with a higher incidence of intrauterine device malposition. MATERIALS AND METHODS: We conducted a retrospective case-control study in an academic medical center. All patients presenting for scheduled ultrasound appointments for gynecologic indication between June 2004 and February 2016 were included (1,253 ultrasound reports identified). Of these, 236 demonstrated malpositioned intrauterine devices. With a control group of 281 patients with normal intrauterine device location, a total of 517 patients were included in the study. Transabdominal and transvaginal ultrasounds were performed followed by 3-dimensional rendering (as per our institution's protocol for patients with intrauterine devices) using Voluson 730 and Voluson E8 ultrasound machines. Demographic and reproductive characteristics, indication for ultrasound, intrauterine device, and uterine characteristics were all extrapolated from the electronic medical record. χ2 Tests were performed for categorical variables. Generalized linear models for Poisson distributed variables, and multiple logistic regression were used to ascertain significant independent predictors of IUD malposition. Ninety-five percent confidence intervals and effect sizes were calculated, and P < .05 was considered statistically significant. RESULTS: In this study, we found a cumulative IUD malposition rate of 19%. In patients with malpositioned intrauterine devices, there was increased incidence of retroflexed uterine positions (7.6% vs 1.8%, P = .001), and all uterine anomalies (this includes septate and bicornuate uteri and fibroids, 31.9% vs 23.5%, P = .02) compared with controls. The anterior midline uterine position was more commonly noted in controls (28.5% vs 11%, P < .001). A higher total number of fibroids was noted in the malpositioned group (3.7 vs 1.8, P = .01); however, fibroid size was not statistically significant. In particular, there was an increased incidence of submucosal fibroids in women with malpositioned intrauterine devices (P = .01). Multivariable logistic regression revealed that anterior midline position (odds ratio [OR], 0.33; 95% confidence interval [CI], 0.20-0.57) and absence of uterine anomalies (OR, 0.59; 95% CI, 0.38-0.93) were factors associated with a lower risk of IUD malposition; whereas vaginal bleeding (OR, 2.25; 95% CI, 1.38-3.67), pain (OR, 2.85; 95% CI, 1.84-4.44), or missing IUD strings at time of presentation (OR, 3.58; 95% CI, 1.88-6.82) were associated with an increased risk of malposition. CONCLUSION: Retroflexed uterine positions and all uterine malformations are associated with higher incidence of malpositioned intrauterine devices. Presence of increased number of fibroids and specifically submucosal fibroids showed a positive association with intrauterine device malposition, as did symptoms of bleeding, pain, and missing IUD strings at time of presentation. These findings pertain to women presenting for gynecologic ultrasound evaluation and may not be generalizable to all women with IUDs.


Assuntos
Migração de Dispositivo Intrauterino/etiologia , Leiomioma/complicações , Anormalidades Urogenitais/complicações , Neoplasias Uterinas/complicações , Útero/anormalidades , Adulto , Estudos de Casos e Controles , Feminino , Humanos , Migração de Dispositivo Intrauterino/efeitos adversos , Leiomioma/diagnóstico por imagem , Modelos Lineares , Modelos Logísticos , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Ultrassonografia , Anormalidades Urogenitais/diagnóstico por imagem , Neoplasias Uterinas/diagnóstico por imagem , Útero/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA