Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 45
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38839726

RESUMO

PURPOSE: In vivo studies are often required to prove the functionality and safety of medical devices. Clinical trials are costly and complex, adding to ethical scrutiny of animal testing. Anthropomorphic phantoms with versatile functionalities can overcome these issues with regard to medical education or an effective development of assistance systems during image-guided interventions (e.g., robotics, navigation/registration algorithms). In this work, an MRI-compatible and customizable motion phantom is presented to mimic respiratory-triggered organ movement as well as human anatomy. METHODS: For this purpose, polyvinyl alcohol cryogel (PVA-C) was the foundation for muscles, liver, kidneys, tumors, and remaining abdominal tissue in different sizes of the abdominal phantom body (APB) with the ability to mimic human tissue in various properties. In addition, a semi-flexible rib cage was 3D-printed. The motion unit (MU) with an electromagnetically shielded stepper motor and mechanical extensions simulated a respiration pattern to move the APB. RESULTS: Each compartment of the APB complied the relaxation times, dielectricity, and elasticity of human tissue. It showed resistance against mold and provided a resealable behavior after needle punctures. During long-term storage, the APB had a weight loss of 2.3%, followed by changes to relaxation times of 9.3% and elasticity up to 79%. The MU was able to physiologically appropriately mimic the organ displacement without reducing the MRI quality. CONCLUSION: This work presents a novel modularizable and low-cost PVA-C based APB to mimic fundamental organ motion. Beside a further organ motion analysis, an optimization of APB's chemical composition is needed to ensure a realistic motion simulation and reproducible long-term use. This phantom enhances diverse and varied training environments for prospective physicians as well as effective R&D of medical devices with the possibility to reduce in vivo experiments.

2.
Eur Heart J ; 43(12): 1207-1215, 2022 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-34788416

RESUMO

AIMS: Clinical trials have demonstrated the safety and efficacy of the Micra leadless VVI pacemaker; however, longer-term outcomes in a large, real-world population with a contemporaneous comparison to transvenous VVI pacemakers have not been examined. We compared reinterventions, chronic complications, and all-cause mortality at 2 years between leadless VVI and transvenous VVI implanted patients. METHODS AND RESULTS: The Micra Coverage with Evidence Development study is a continuously enrolling, observational, cohort study of leadless VVI pacemakers in the US Medicare fee-for-service population. Patients implanted with a leadless VVI pacemaker between March 9, 2017, and December 31, 2018, were identified using Medicare claims data linked to manufacturer device registration data (n = 6219). All transvenous VVI patients from facilities with leadless VVI implants during the study period were obtained directly from Medicare claims (n = 10 212). Cox models were used to compare 2-year outcomes between groups. Compared to transvenous VVI, patients with leadless VVI had more end-stage renal disease (12.0% vs. 2.3%) and a higher Charlson comorbidity index (5.1 vs. 4.6). Leadless VVI patients had significantly fewer reinterventions [adjusted hazard ratio (HR) 0.62, 95% confidence interval (CI) 0.45-0.85, P = 0.003] and chronic complications (adjusted HR 0.69, 95% CI 0.60-0.81, P < 0.0001) compared with transvenous VVI patients. Adjusted all-cause mortality at 2 years was not different between the two groups (adjusted HR 0.97, 95% CI 0.91-1.04, P = 0.37). CONCLUSION: In a real-world study of US Medicare patients, the Micra leadless VVI pacemaker was associated with a 38% lower adjusted rate of reinterventions and a 31% lower adjusted rate of chronic complications compared with transvenous VVI pacing. There was no difference in adjusted all-cause mortality at 2 years.


Assuntos
Estimulação Cardíaca Artificial , Marca-Passo Artificial , Idoso , Estimulação Cardíaca Artificial/métodos , Estudos de Coortes , Desenho de Equipamento , Seguimentos , Humanos , Medicare , Resultado do Tratamento , Estados Unidos/epidemiologia
3.
Annu Int Conf IEEE Eng Med Biol Soc ; 2021: 3382-3386, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34891965

RESUMO

RF absorption in patients undergoing MRI procedures poses a major safety risk due to resulting heating in the tissue. In order to stay below permitted temperature limits the SAR has to be quantified and limited. Based on the model of an infant inside a birdcage coil we have investigated the SAR distribution in the body at 1.5T. Thermal simulations could thus be performed to establish a relationship between the limitations of SAR and temperature. Results show a thermal hotspot in the neck region caused by high local absorption. The temperature limits in this local area were exceeded after 7min of excitation within regulatory SAR limits. For a long-term exposure critical organs in the body's core also undergo thermal stress beyond limitations. This indicates the need for constraints in regard to long MR procedures to consider the temporal aspect of heating.Clinical Relevance-This work establishes a relationship between SAR and temperature in infants undergoing MRI and shows potential risks of long-term procedures due to induced thermal stress.


Assuntos
Calefação , Ondas de Rádio , Simulação por Computador , Humanos , Imageamento por Ressonância Magnética/efeitos adversos , Imagens de Fantasmas
4.
JAMA Cardiol ; 6(10): 1187-1195, 2021 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-34319383

RESUMO

Importance: The safety and efficacy of leadless VVI pacemakers have been demonstrated in multiple clinical trials, but the comparative performance of the device in a large, real-world population has not been examined. Objective: To compare patient characteristics and complications among patients implanted with leadless VVI and transvenous VVI pacemakers. Design, Setting, Participants: The Longitudinal Coverage With Evidence Development Study on Micra Leadless Pacemakers (Micra CED) is a continuously enrolling observational cohort study evaluating complications, utilization, and outcomes of leadless VVI pacemakers in the US Medicare fee-for-service population. Patients implanted between March 9, 2017, and December 1, 2018, were identified and included. All Medicare patients implanted with leadless VVI and transvenous VVI pacemakers during the study period were enrolled. Patients with less than 12 months of continuous enrollment in Medicare prior to leadless VVI or transvenous VVI implant and with evidence of a prior cardiovascular implantable electronic device were excluded, leaving 5746 patients with leadless VVI pacemakers and 9662 patients with transvenous VVI pacemakers. Data were analyzed from May 2018 to April 2021. Exposures: Medicare patients implanted with leadless VVI pacemakers or transvenous VVI pacemakers. Main Outcomes and Measures: The main outcomes were acute (30-day) complications and 6-month complications. Results: Of 15 408 patients, 6701 (43.5%) were female, and the mean (SD) age was 81.0 (8.7) years. Compared with patients with transvenous VVI pacemakers, patients with leadless VVI pacemakers were more likely to have end-stage kidney disease (690 [12.0%] vs 226 [2.3%]; P < .001) and a higher mean (SD) Charlson Comorbidity Index score (5.1 [3.4] vs 4.6 [3.0]; P < .001). The unadjusted acute complication rate was higher in patients with leadless VVI pacemakers relative to transvenous VVI pacemakers (484 of 5746 [8.4%] vs 707 of 9662 [7.3%]; P = .02). However, there was no significant difference in overall acute complication rates following adjustment for patient characteristics (7.7% vs 7.4%; risk difference, 0.3; 95% CI, -0.6 to 1.3; P = .49). Pericardial effusion and/or perforation within 30 days was significantly higher among patients with leadless VVI pacemakers compared with patients with transvenous VVI pacemakers in both unadjusted and adjusted models (unadjusted, 47 of 5746 [0.8%] vs 38 of 9662 [0.4%]; P < .001; adjusted, 0.8% vs 0.4%; risk difference, 0.4; 95% CI, 0.1 to 0.7; P = .004). Patients implanted with leadless VVI pacemakers had a lower rate of 6-month complications compared with patients implanted with transvenous VVI pacemakers (unadjusted hazard ratio, 0.84; 95% CI, 0.68-1.03; P = .10; adjusted hazard ratio, 0.77; 95% CI, 0.62-0.96; P = .02). Conclusions and Relevance: In this study, despite significant differences in patient characteristics, patients in whom a leadless pacemaker was implanted were observed to have higher rates of pericardial effusion and/or perforation but lower rates of other device-related complications and requirements for device revision at 6 months. Understanding the benefits and risks associated with leadless VVI pacemakers compared with transvenous VVI pacemakers can help clinicians and patients make informed treatment decisions.


Assuntos
Bradicardia/terapia , Cateterismo Cardíaco/métodos , Marca-Passo Artificial , Idoso de 80 Anos ou mais , Bradicardia/mortalidade , Bradicardia/fisiopatologia , Causas de Morte/tendências , Feminino , Seguimentos , Ventrículos do Coração , Humanos , Masculino , Estudos Retrospectivos , Taxa de Sobrevida/tendências , Fatores de Tempo , Estados Unidos/epidemiologia
5.
Europace ; 21(11): 1686-1693, 2019 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-31681964

RESUMO

AIMS: Patient selection is a key component of securing optimal patient outcomes with leadless pacing. We sought to describe and compare patient characteristics and outcomes of Micra patients with and without a primary pacing indication associated with atrial fibrillation (AF) in the Micra IDE trial. METHODS AND RESULTS: The primary outcome (risk of cardiac failure, pacemaker syndrome, or syncope related to the Micra system or procedure) was compared between successfully implanted patients from the Micra IDE trial with a primary pacing indication associated with AF or history of AF (AF group) and those without (non-AF group). Among 720 patients successfully implanted with Micra, 228 (31.7%) were in the non-AF group. Reasons for selecting VVI pacing in non-AF patients included an expectation for infrequent pacing (66.2%) and advanced age (27.2%). More patients in the non-AF group had a condition that precluded the use of a transvenous pacemaker (9.6% vs. 4.7%, P = 0.013). Atrial fibrillation patients programmed to VVI received significantly more ventricular pacing compared to non-AF patients (median 67.8% vs. 12.6%; P < 0.001). The overall occurrence of the composite outcome at 24 months was 1.8% with no difference between the AF and non-AF groups (hazard ratio 1.36, 95% confidence interval 0.45-4.2; P = 0.59). CONCLUSION: Nearly one-third of patients selected to receive Micra VVI therapy were for indications not associated with AF. Non-AF VVI patients required less frequent pacing compared to patients with AF. Risks associated with VVI therapy were low and did not differ in those with and without AF.


Assuntos
Fibrilação Atrial/terapia , Estimulação Cardíaca Artificial/métodos , Ventrículos do Coração/fisiopatologia , Marca-Passo Artificial , Seleção de Pacientes , Idoso , Fibrilação Atrial/fisiopatologia , Desenho de Equipamento , Feminino , Humanos , Masculino , Estudos Prospectivos , Resultado do Tratamento
7.
Am Heart J ; 190: 19-24, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28760209

RESUMO

BACKGROUND: Approximately 20% of ischemic strokes are associated with clinically apparent atrial fibrillation (AF). Regardless of stroke etiology, detection of AF in patients with ischemic strokes often changes antithrombotic treatment from anti-platelet to oral anticoagulation therapy. The role and the optimum duration of cardiac monitoring to detect AF in patients with strokes presumed due to large vessel atherosclerosis or small vessel disease is unknown. This manuscript describes the design and rationale of the STROKE-AF trial. STUDY DESIGN: STROKE-AF is a randomized, controlled, open-label, post-market clinical trial. Detection of AF will be evaluated using continuous arrhythmia monitoring with an insertable cardiac monitor (ICM) compared with standard of care follow-up in patients with stroke (within the prior 10 days) that is presumed due to large vessel cervical or intracranial atherosclerosis, or to small vessel disease. Approximately 500 patients will be enrolled at approximately 40 centers in the United States. Patients will be randomized 1:1 to arrhythmia monitoring with an ICM (continuous monitoring arm) or standard of care follow-up (control arm). Subjects will be followed for ≥12 months and up to 3 years. OUTCOMES: The primary objective is to compare the incidence rate of detected AF through 12 months of follow-up between the two arms. CONCLUSION: This trial will provide information on the value of ICMs to detect subclinical AF in patients with stroke presumed due to large vessel atherosclerosis or small vessel disease, which will have implications for guiding treatment with oral anticoagulation for secondary stroke prevention.


Assuntos
Anticoagulantes/administração & dosagem , Fibrilação Atrial/complicações , Acidente Vascular Cerebral/etiologia , Administração Oral , Eletrocardiografia Ambulatorial/métodos , Feminino , Seguimentos , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Prospectivos , Fatores de Risco , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/prevenção & controle , Taxa de Sobrevida/tendências , Fatores de Tempo , Estados Unidos/epidemiologia
8.
JACC Clin Electrophysiol ; 3(4): 393-402, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-28596994

RESUMO

INTRODUCTION: The role of atrial fibrillation (AF) substrates is unclear in patients with paroxysmal AF (PAF) that recurs after pulmonary vein isolation (PVI). We hypothesized that patients with recurrent post-ablation (redo) PAF despite PVI have electrical substrates marked by rotors and focal sources, and structural substrates that resemble persistent AF more than patients with (de novo) PAF at first ablation. METHODS: In 175 patients at 11 centers, we compared AF substrates in both atria using 64 pole-basket catheters and phase mapping, and indices of anatomical remodeling between patients with de novo or redo PAF and first ablation for persistent AF. RESULTS: Sources were seen in all patients. More patients with de novo PAF (78.0%) had sources near PVs than patients with redo PAF (47.4%, p=0.005) or persistent AF (46.9%, p=0.001). The total number of sources per patient (p=0.444), and number of non-PV sources (p=0.701) were similar between groups, indicating that redo PAF patients had residual non-PV sources after elimination of PV sources by prior PVI. Structurally, left atrial size did not separate de novo from redo PAF (49.5±9.5 vs. 49.0±7.1mm, p=0.956) but was larger in patients with persistent AF (55.2±8.4mm, p=0.001). CONCLUSIONS: Patients with paroxysmal AF despite prior PVI show electrical substrates that resemble persistent AF more closely than patients with paroxysmal AF at first ablation. Notably, these subgroups of paroxysmal AF are indistinguishable by structural indices. These data motivate studies of trigger versus substrate mechanisms for patients with recurrent paroxysmal AF after PVI.


Assuntos
Fibrilação Atrial/patologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Humanos , Recidiva , Reoperação , Resultado do Tratamento
9.
J Hosp Med ; 12(5): 329-331, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-28459901

RESUMO

Troponin assays are integral to the diagnosis of acute myocardial infarction (AMI), but there is concern that testing is over utilized and may not conform to published guidelines. We reviewed all testing performed at 14 hospitals over 12 months and associated troponin values with the primary and secondary diagnoses for each visit. Troponin was determined to be negative, indeterminate or elevated based on reference ranges. The majority of troponin measurements were single, not serial (64%). The rate of AMI was low, with only 3.5% of tested patients having a primary or secondary diagnosis of AMI. Sensitivity, specificity and negative predictive value were excellent, exceeding 90%. However, positive predictive value was low, suggesting testing of populations with diseases known to be associated with elevated troponin levels in the absence of AMI. The majority (79%) of elevated troponin values were associated with primary diagnoses other than AMI. Only 28% of elevated troponins were associated with a primary or secondary diagnosis of AMI. These data suggest possible overuse of troponin testing in our healthcare system. Journal of Hospital Medicine 2017;12:329-331.


Assuntos
Prestação Integrada de Cuidados de Saúde/normas , Infarto do Miocárdio/sangue , Infarto do Miocárdio/diagnóstico , Troponina/sangue , Biomarcadores/sangue , Humanos , Estudos Retrospectivos
10.
Heart Rhythm ; 14(9): 1375-1379, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28502871

RESUMO

BACKGROUND: First-in-man studies of leadless pacemakers have demonstrated high rates of implant success, and safety and efficacy objectives were achieved. Outside of the investigational setting, there are concerns, particularly over cardiac effusion and perforation, device dislodgement, infection, telemetry, and battery issues. OBJECTIVE: The acute performance of the Micra transcatheter pacemaker from a worldwide Post-Approval Registry is reported. METHODS: The registry is an ongoing prospective single-arm observational study designed to assess the safety and effectiveness of Micra in the post-approval setting. The safety end point was system- or procedure-related major complications at 30 days post implant. We compared the major complication rate with that of the 726 patients from the investigational study. Electrical performance was also characterized. RESULTS: The device was successfully implanted in 792 of 795 registry patients (99.6%) by 149 implanters at 96 centers in 20 countries. Through 30 days post implant, a total of 13 major complications occurred in 12 patients, for a major complication rate of 1.51% (95% confidence interval, 0.78%-2.62%). Major complications included cardiac effusion/perforation (1, 0.13%), device dislodgement (1, 0.13%), and sepsis (1, 0.13%). After adjusting for baseline differences, the rate of major complications in the registry trended lower than the investigational trial (odds ratio, 0.58, 95% confidence interval, 0.27-1.25; P = .16). Early pacing capture thresholds were low and stable. CONCLUSION: Performance of the Micra transcatheter pacemaker in a real-world setting demonstrates a high rate (99.6%) of implant success and low rate (1.51%) of major complications through 30 days post implant. In particular, the rates of pericardial effusion, device dislodgement, and infection were low, reinforcing the positive results seen in the investigational study.


Assuntos
Arritmias Cardíacas/terapia , Cateterismo Cardíaco/métodos , Aprovação de Equipamentos , Marca-Passo Artificial , Sistema de Registros , Idoso , Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/fisiopatologia , Desenho de Equipamento , Feminino , Saúde Global , Humanos , Masculino , Morbidade , Estudos Prospectivos , Resultado do Tratamento
11.
Pacing Clin Electrophysiol ; 40(7): 834-842, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28439940

RESUMO

BACKGROUND: Leadless pacemaker systems have been designed to avoid the need for a pocket and transvenous lead. However, delivery of this therapy requires a new catheter-based procedure. This study evaluates the role of operator experience and different training strategies on procedural outcomes. METHODS: A total of 726 patients underwent implant attempt with the Micra transcatheter pacing system (TPS; Medtronic, Minneapolis, MN, USA) by 94 operators trained in a teaching laboratory using a simulator, cadaver, and large animal models (lab training) or locally at the hospital with simulator/demo model and proctorship (hospital training). Procedure success, procedure duration, fluoroscopy time, and safety outcomes were compared between training methods and experience (implant case number). RESULTS: The Micra TPS procedure was successful in 99.2% of attempts and did not differ between the 55 operators trained in the lab setting and the 39 operators trained locally at the hospital (P = 0.189). Implant case number was also not a determinant of procedural success (P = 0.456). Each operator performed between one and 55 procedures. Procedure time and fluoroscopy duration decreased by 2.0% (P = 0.002) and 3.2% (P < 0.001) compared to the previous case. Major complication rate and pericardial effusion rate were not associated with case number (P = 0.755 and P = 0.620, respectively). There were no differences in the safety outcomes by training method. CONCLUSIONS: Among a large group of operators, implantation success was high regardless of experience. While procedure duration and fluoroscopy times decreased with implant number, complications were low and not associated with case number. Procedure and safety outcomes were similar between distinct training methodologies.


Assuntos
Arritmias Cardíacas/terapia , Cateteres Cardíacos , Estimulação Cardíaca Artificial/métodos , Competência Clínica , Idoso , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Masculino , Marca-Passo Artificial , Segurança do Paciente , Resultado do Tratamento
12.
Am J Cardiol ; 119(8): 1153-1155, 2017 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-28214504

RESUMO

Troponin elevation is required to diagnose acute myocardial infarction (AMI), yet elevated values are often encountered in noncardiac disease states. We evaluated inpatient (IP) and outpatient (OP) encounters at 14 hospitals in calendar year 2014 and found that troponin assays were performed during 12% of all OP visits and 29% of all IP visits: 82,853 encounters in all. We employed an expert panel to estimate the likelihood of AMI based on primary International Statistical Classification of Diseases and Related Health Problems, 9th edition diagnoses. We compared IP and OP testing, finding that AMI would not be expected in most IP encounters. Sepsis was the most common diagnosis associated with IP troponin testing. We found an association between troponin testing in patients with sepsis and utilization of electrocardiography, echocardiography, and cardiac catheterization. Our data indicate that troponin testing has expanded beyond patient populations in whom AMI might be expected.


Assuntos
Serviço Hospitalar de Emergência , Hospitalização , Visita a Consultório Médico , Padrões de Prática Médica/estatística & dados numéricos , Troponina I/sangue , Cateterismo Cardíaco/estatística & dados numéricos , Ecocardiografia/estatística & dados numéricos , Eletrocardiografia/estatística & dados numéricos , Humanos , Infarto do Miocárdio/diagnóstico , Pneumonia/sangue , Pneumonia/diagnóstico , Estudos Retrospectivos , Sepse/sangue , Sepse/diagnóstico
13.
Proc (Bayl Univ Med Cent) ; 30(1): 3-6, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28127119

RESUMO

Cryoablation for atrial fibrillation (AF) has rapidly become a mainstream treatment for AF. In this report, 163 patients who had undergone a cryoablation procedure at one clinical center were contacted by telephone 33.1 ± 3.3 months after the procedure. All patients had received cryoablation of the pulmonary vein ostia, although concomitant procedures were performed at the same time in over 50% of the patients, including radiofrequency and/or cryoablation of other areas of the left atrium. Freedom from a repeat ablation procedure was 87%, while freedom from recurrent hospitalization for AF was 89%, as compared to previous reports of 65%. Of the 13 patients who had a repeat ablation procedure, only one was found to have a reconnection of pulmonary veins, while 4 were found to have atrial flutter. Cryoablation for AF produces a durable result in most patients out to 3 years with better outcomes than previously reported.

14.
Heart Rhythm ; 14(5): 685-691, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-28111349

RESUMO

BACKGROUND: Device repositioning during Micra leadless pacemaker implantation may be required to achieve optimal pacing thresholds. OBJECTIVE: The purpose of this study was to describe the natural history of acute elevated Micra vs traditional transvenous lead thresholds. METHODS: Micra study VVI patients with threshold data (at 0.24 ms) at implant (n = 711) were compared with Capture study patients with de novo transvenous leads at 0.4 ms (n = 538). In both cohorts, high thresholds were defined as >1.0 V and very high as >1.5 V. Change in pacing threshold (0-6 months) with high (1.0 to ≤1.5 V) or very high (>1.5 V) thresholds were compared using the Wilcoxon signed-rank test. RESULTS: Of the 711 Micra patients, 83 (11.7%) had an implant threshold of >1.0 V at 0.24 ms. Of the 538 Capture patients, 50 (9.3%) had an implant threshold of >1.0 V at 0.40 ms. There were no significant differences in patient characteristics between those with and without an implant threshold of >1.0 V, with the exception of left ventricular ejection fraction in the Capture cohort (high vs low thresholds, 53% vs 58%; P = .011). Patients with an implant threshold of >1.0 V decreased significantly (P < .001) in both cohorts. Micra patients with high and very high thresholds decreased significantly (P < .01) by 1 month, with 87% and 85% having 6-month thresholds lower than the implant value. However, when the capture threshold at implant was >2 V, only 18.2% had a threshold of ≤1 V at 6 months and 45.5% had a capture threshold of >2 V. CONCLUSIONS: Pacing thresholds in most Micra patients with elevated thresholds decrease after implant. Micra device repositioning may not be necessary if the pacing threshold is ≤2 V.


Assuntos
Bradicardia/terapia , Estimulação Cardíaca Artificial/métodos , Eletrocardiografia , Marca-Passo Artificial , Adulto , Idoso , Idoso de 80 Anos ou mais , Bradicardia/fisiopatologia , Cateteres Cardíacos , Limiar Diferencial , Eletrodos Implantados , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
15.
Heart Rhythm ; 14(2): 218-224, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-27825975

RESUMO

BACKGROUND: Recent miniaturization of an insertable cardiac monitor (ICM) may make it possible to move device insertion from a hospital to office setting. However, the safety of this strategy is unknown. OBJECTIVES: The primary objective was to compare the safety of inserting the Reveal LINQ ICM in an office vs a hospital environment. Ancillary objectives included summarizing device- and procedure-related adverse events and responses to a physician questionnaire. METHODS: Five hundred twenty-one patients indicated for an ICM were randomized (1:1 ratio) to undergo ICM insertion in a hospital or office environment at 26 centers in the United States in the Reveal LINQ In-Office 2 study (ClinicalTrials.gov identifier NCT02395536). Patients were followed for 90 days. RESULTS: ICM insertion was successful in all 482 attempted patients (office: 251; hospital: 231). The untoward event rate (composite of unsuccessful insertion and ICM- or insertion-related complications) was 0.8% (2 of 244) in the office and 0.9% (2 of 227) in the hospital (95% confidence interval, -3.0% to 2.9%; 5% noninferiority: P < .001). In addition, adverse events occurred during 2.5% (6 of 244) of office and 4.4% (10 of 227) of hospital insertions (95% confidence interval [office minus inhospital rates], -5.8% to 1.9%; 5% noninferiority: P < .001). Physicians indicated that for procedures performed in an office vs a hospital, there were fewer delays >15 minutes (16% vs 35%; P < .001) and patient response was more often "very positive." Physicians considered the office location "very convenient" more frequently than the hospital location (85% vs 27%; P < .001). CONCLUSION: The safety profile for the insertion of the Reveal LINQ ICM is excellent irrespective of insertion environment. These results may expand site of service options for LINQ insertion.


Assuntos
Arritmias Cardíacas/diagnóstico , Eletrocardiografia Ambulatorial , Miniaturização/métodos , Complicações Pós-Operatórias/epidemiologia , Implantação de Prótese , Idoso , Procedimentos Cirúrgicos Ambulatórios/instrumentação , Procedimentos Cirúrgicos Ambulatórios/métodos , Eletrocardiografia Ambulatorial/instrumentação , Eletrocardiografia Ambulatorial/métodos , Meio Ambiente , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Avaliação de Processos e Resultados em Cuidados de Saúde , Preferência do Paciente/estatística & dados numéricos , Implantação de Prótese/efeitos adversos , Implantação de Prótese/métodos , Estados Unidos
16.
Am J Cardiol ; 118(10): 1527-1532, 2016 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-27666171

RESUMO

The prognostic implications of preexisting atrial fibrillation (AF) and new-onset AF (NOAF) in transcatheter aortic valve implantation (TAVI) remain uncertain. This study assesses the epidemiology of AF in patients treated with TAVI and evaluates their outcomes according to the presence of preexisting AF or NOAF. A retrospective analysis of 708 patients undergoing TAVI from 2 heart hospitals was performed. Patients were divided into 3 study groups: sinus rhythm (n = 423), preexisting AF (n = 219), and NOAF (n = 66). Primary outcomes of interest were all-cause death and stroke both at 30-day and at 1-year follow-up. Preexisting AF was present in 30.9% of our study population, whereas NOAF was observed in 9.3% of patients after TAVI. AF and NOAF patients showed a higher rate of 1-year all-cause mortality compared with patients in sinus rhythm (14.6% vs 6.5% for preexisting AF and 16.3% vs 6.5% for NOAF, p = 0.007). No differences in 30-day mortality were observed between groups. In patients with AF (either preexisting and new-onset), those discharged with single antiplatelet therapy displayed higher mortality rates at 1 year (42.9% vs 11.7%, p = 0.006). Preexisting AF remained an independent predictor of mortality at 1-year follow-up (hazard ratio [HR] 2.34, 95% CI 1.22 to 4.48, p = 0.010). Independent predictors of NOAF were transapical and transaortic approach as well as balloon postdilatation (HR 3.48, 95% CI 1.66 to 7.29, p = 0.001; HR 5.08, 95% CI 2.08 to 12.39, p <0.001; HR 2.76, 95% CI 1.25 to 6.08, p = 0.012, respectively). In conclusion, preexisting AF is common in patients undergoing TAVI and is associated with a twofold increased risk of 1-year mortality. This negative effect is most pronounced in patients discharged with single antiplatelet therapy compared with other antithrombotic regimens.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Fibrilação Atrial/epidemiologia , Complicações Pós-Operatórias/epidemiologia , Idoso de 80 Anos ou mais , Fibrilação Atrial/etiologia , Causas de Morte/tendências , Eletrocardiografia , Feminino , Seguimentos , Humanos , Incidência , Masculino , Prevalência , Prognóstico , Estudos Retrospectivos , Fatores de Risco , Taxa de Sobrevida/tendências , Texas/epidemiologia , Fatores de Tempo , Substituição da Valva Aórtica Transcateter
17.
J Cardiovasc Electrophysiol ; 27(12): 1495-1501, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27600684

RESUMO

Two major studies have shown that leadless pacemakers are safe and effective for patients requiring right ventricular rate responsive pacing therapy. This positive result recently led to FDA approval of one of the available leadless pacing devices. While this new technology is promising, it requires a different skill set for safe implantation. In this article, we review in detail the different steps required for implantation of tine-based leadless pacemakers while providing tips and tricks to minimize complications.


Assuntos
Cateterismo Cardíaco/instrumentação , Cateteres Cardíacos , Estimulação Cardíaca Artificial , Marca-Passo Artificial , Desenho de Equipamento , Humanos , Radiografia Intervencionista , Resultado do Tratamento
18.
Heart Rhythm ; 12(7): 1658-66, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25778428

RESUMO

BACKGROUND: Since the release of the second-generation cryoballoon (CB2; Arctic Front Advance(TM), Medtronic Inc) and its design modifications with improved cooling characteristics, the technique, dosing, and complication profile is significantly different from that of the first-generation cryoballoon. A comprehensive report of CB2 procedural recommendations has not been reported. OBJECTIVE: The purpose of this study was to review the current best practices from a group of experienced centers to create a user's consensus guide for CB2 ablation. METHODS/RESULTS: High-volume operators with a combined experience of more than 3000 CB2 cases were interviewed, and consensus for technical and procedural best practice was established. CONCLUSION: Comprehensive review of the CB2 ablation best practice guide will provide a detailed technique for achieving safer and more effective outcomes for CB2 atrial fibrillation ablation.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Criocirurgia/métodos , Técnicas de Imagem Cardíaca/métodos , Humanos , Guias de Prática Clínica como Assunto , Veias Pulmonares/cirurgia , Resultado do Tratamento
19.
J Cardiovasc Electrophysiol ; 25(9): 921-929, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24948520

RESUMO

INTRODUCTION: The success of pulmonary vein isolation (PVI) for atrial fibrillation (AF) may be improved if stable AF sources identified by Focal Impulse and Rotor Mapping (FIRM) are also eliminated. The long-term results of this approach are unclear outside the centers where FIRM was developed; thus, we assessed outcomes of FIRM-guided AF ablation in the first cases at 10 experienced centers. METHODS: We prospectively enrolled n = 78 consecutive patients (61 ± 10 years) undergoing FIRM guided ablation for persistent (n = 48), longstanding persistent (n = 7), or paroxysmal (n = 23) AF. AF recordings from both atria with a 64-pole basket catheter were analyzed using a novel mapping system (Rhythm View(TM) ; Topera Inc., CA, USA). Identified rotors/focal sources were ablated, followed by PVI. RESULTS: Each institution recruited a median of 6 patients, each of whom showed 2.3 ± 0.9 AF rotors/focal sources in diverse locations. 25.3% of all sources were right atrial (RA), and 50.0% of patients had ≥1 RA source. Ablation of all sources required a total of 16.6 ± 11.7 minutes, followed by PVI. On >1 year follow-up with a 3-month blanking period, 1 patient lost to follow-up (median time to 1st recurrence: 245 days, IQR 145-354), single-procedure freedom from AF was 87.5% (patients without prior ablation; 35/40) and 80.5% (all patients; 62/77) and similar for persistent and paroxysmal AF (P = 0.89). CONCLUSIONS: Elimination of patient-specific AF rotors/focal sources produced freedom-from-AF of ≈80% at 1 year at centers new to FIRM. FIRM-guided ablation has a rapid learning curve, yielding similar results to original FIRM reports in each center's first cases.


Assuntos
Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sistema de Registros , Resultado do Tratamento
20.
Proc (Bayl Univ Med Cent) ; 26(4): 398-400, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24082419

RESUMO

Vascular closure devices were introduced in the early 1990s in an effort to reduce time to hemostasis, enable early ambulation, and improve the comfort of patients undergoing femoral artery access for endovascular procedures. Many of these devices leave a foreign component in or around the artery, which can lead to complications such as hematoma, pseudoaneurysm, infection, or limb ischemia. Here we present a case where device embolization led to arterial occlusion and critical limb ischemia.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...