Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
AJR Am J Roentgenol ; 215(6): 1520-1527, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33052735

RESUMO

OBJECTIVE. The purpose of this study was to assess the image quality and resource utilization of single-injection, split-bolus, dual-enhancement abdominopelvic CT angiography (hereafter referred to as dual-enhancement CTA) performed for combined vascular and solid organ assessment compared with those of single-injection, single-enhancement abdominopelvic CT angiography (hereafter referred to as single-enhancement CTA) for vascular assessment in combination with additional examinations (CT, MRI, and US) performed to assess for malignancy in lung transplant candidates. MATERIALS AND METHODS. We retrospectively reviewed 100 patients who underwent abdominopelvic CTA examinations before lung transplant. Cohort A (n = 50) underwent dual-enhancement CTA and cohort B (n = 50) underwent single-enhancement CTA. Contrast opacification of the vasculature was assessed along the abdominal aorta through the right femoral artery. Solid organ enhancement was assessed in the right lobe of the liver and the right renal cortex. Measurements of mean radiation dose, contrast exposure, and cost of the studies (in U.S. dollars) were compared. RESULTS. Mean (± SD) vascular enhancement on dual-enhancement CTA and single-enhancement CTA was 334.2 ± 26.5 HU (coefficient of variation, 8.3%) and 340.0 ± 21.6 HU (coefficient of variation, 6.5%) (p = 0.23), respectively. For dual-enhancement CTA and single-enhancement CTA, mean liver enhancement was 125.8 ± 30.5 HU and 60.4 ± 6.9 HU (p < 0.01), respectively, whereas mean renal cortical enhancement was 260.3 ± 62.2 HU and 133.4 ± 38.6 HU (p < 0.01), respectively. The mean IV contrast volume was 150 mL for dual-enhancement CTA and 75 mL for single-enhancement CTA. Cohort A underwent six additional imaging studies (one of which was a CT colonography study with an effective dose of 19.0 mSv) at a total cost of $9840 per patient. Cohort B underwent 44 additional imaging studies (mean effective dose, 12.7 ± 6.5 mSv) at a total cost of $12,846 per patient (resulting in a 30.6% reduction in cost for dual-enhancement CTA studies; p < 0.0001). CONCLUSION. Dual-enhancement abdominopelvic CTA allows combined vascular and abdominopelvic solid organ assessment with improved image quality and a lower cost compared with traditional imaging pathways.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Transplante de Pulmão , Radiografia Abdominal/métodos , Adulto , Idoso , Meios de Contraste , Feminino , Humanos , Iopamidol , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos
2.
Radiology ; 292(3): 597-605, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31335283

RESUMO

Background Coronary artery fractional flow reserve (FFR) derived from CT angiography (FFTCT) enables functional assessment of coronary stenosis. Prior clinical trials showed 13%-33% of coronary CT angiography studies had insufficient quality for quantitative analysis with FFRCT. Purpose To determine the rejection rate of FFRCT analysis and to determine factors associated with technically unsuccessful calculation of FFRCT. Materials and Methods Prospectively acquired coronary CT angiography scans submitted as part of the Assessing Diagnostic Value of Noninvasive FFRCT in Coronary Care (ADVANCE) registry (https://ClinicalTrials.gov: NCT02499679) and coronary CT angiography series submitted for clinical analysis were included. The primary outcome was the FFRCT rejection rate (defined as an inability to perform quantitative analysis with FFRCT). Factors that were associated with FFRCT rejection rate were assessed with multiple linear regression. Results In the ADVANCE registry, FFRCT rejection rate due to inadequate image quality was 2.9% (80 of 2778 patients; 95% confidence interval [CI]: 2.1%, 3.2%). In the 10 621 consecutive patients who underwent clinical analysis, the FFRCT rejection rate was 8.4% (n = 892; 95% CI: 6.2%, 7.2%; P < .001 vs the ADVANCE cohort). The main reason for the inability to perform FFRCT analysis was the presence of motion artifacts (63 of 80 [78%] and 729 of 892 [64%] in the ADVANCE and clinical cohorts, respectively). At multivariable analysis, section thickness in the ADVANCE (odds ratio [OR], 1.04; 95% CI: 1.001, 1.09; P = .045) and clinical (OR, 1.03; 95% CI: 1.02, 1.04; P < .001) cohorts and heart rate in the ADVANCE (OR, 1.05; 95% CI: 1.02, 1.08; P < .001) and clinical (OR, 1.06; 95% CI: 1.05, 1.07; P < .001) cohorts were independent predictors of rejection. Conclusion The rates for technically unsuccessful CT-derived fractional flow reserve in the ADVANCE registry and in a large clinical cohort were 2.9% and 8.4%, respectively. Thinner CT section thickness and lower patient heart rate may increase rates of completion of CT fractional flow reserve analysis. Published under a CC BY 4.0 license. Online supplemental material is available for this article. See also the editorial by Sakuma in this issue.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/fisiopatologia , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Idoso , Estudos de Coortes , Feminino , Humanos , Masculino , Estudos Prospectivos , Sistema de Registros , Reprodutibilidade dos Testes , Índice de Gravidade de Doença
3.
J Med Imaging (Bellingham) ; 5(1): 013501, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29376102

RESUMO

The purpose of this study was to develop a dynamic physical cardiac phantom with a realistic coronary plaque to investigate stenosis measurement accuracy under clinically relevant heart-rates. The coronary plaque model (5 mm diameter, 50% stenosis, and 32 mm long) was designed and 3D-printed with tissue equivalent materials (calcified plaque with iodine-enhanced lumen). Realistic cardiac motion was modeled by converting computational cardiac motion vectors into compression and rotation profiles executed by a commercial base cardiac phantom. The phantom was imaged on a dual-source CT system applying a retrospective gated coronary CT angiography (CCTA) protocol using synthesized motion-synchronized electrocardiogram (ECG) waveforms. Multiplanar reformatted images were reconstructed along vessel centerlines. Enhanced lumens were segmented by five independent operators. On average, stenosis measurement accuracy was 0.9% positively biased for the motion-free condition. Average measurement accuracy monotonically decreased from 0.9% positive bias for the motion-free condition to 18.5% negative bias at 90 beats per minute. Contrast-to-noise ratio, lumen circularity, and segmentation conformity also decreased monotonically with increasing heart-rate. These results demonstrate successful implementation of a base cardiac phantom with a 3D-printed coronary plaque model, relevant motion profile, and coordinated ECG waveform. They further show the utility of the model to ascertain metrics of CCTA accuracy and image quality under realistic plaque, motion, and acquisition conditions.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...