Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 105
Filtrar
1.
JACC Asia ; 4(5): 359-372, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38765666

RESUMO

Background: The authors devised the tip detection (TD) method and developed AnteOwl WR intravascular ultrasound to standardize intravascular ultrasound-based 3-dimensional wiring for intraplaque tracking in chronic total occlusion (CTO)-percutaneous coronary intervention (PCI). The TD method also allowed antegrade dissection and re-entry (ADR). Combining TD-ADR with Conquest Pro 12 Sharpened Tip (CP12ST) wire, a new ADR wire with the strongest penetration force developed to date, enabled re-entry anywhere except calcification sites. Objectives: This study investigated the efficacy and feasibility of TD-ADR by comparison of procedural outcomes with Stingray-ADR in CTO-PCI. Methods: Twenty-seven consecutive CTO cases treated by TD-ADR with CP12ST wire between August 2021 and April 2023 and 27 consecutive CTO cases treated by Stingray-ADR with Conquest 8-20 (CP20) wire between March 2018 and July 2021 were retrospectively enrolled as the TD-ADR by CP12ST wire group and Stingray-ADR by CP20 wire group, respectively, from 4 facilities that could share technical information on these procedures. Results: The success rate of the ADR procedure was significantly improved (27 of 27 cases [100%] vs 18 of 27 cases [67%], respectively; P = 0.002) and total procedural time was significantly reduced (median procedural time: 145.0 [Q1-Q3: 118.0-240.0] minutes vs 185.0 [Q1-Q3: 159.5-248.0] minutes, respectively; P = 0.028) in the TD-ADR by CP12ST wire group compared to the Stingray-ADR by CP20 wire group. There were few in-hospital major adverse cardiac and cerebrovascular events or no complications in either group. Conclusions: TD-ADR by CP12ST wire can standardize highly accurate ADR in CTO-PCI.

2.
Sci Rep ; 14(1): 1746, 2024 01 19.
Artigo em Inglês | MEDLINE | ID: mdl-38243047

RESUMO

The coexistence of heart failure is frequent and associated with higher mortality in patients with type 2 diabetes (T2DM), and its management is a critical issue. The WATCH-DM risk score is a tool to predict heart failure in patients with type 2 diabetes mellitus (T2DM). We investigated whether it could estimate outcomes in T2DM patients with heart failure with preserved ejection fraction (HFpEF). The WATCH-DM risk score was calculated in 418 patients with T2DM hospitalized for HFpEF (male 49.5%, age 80 ± 9 years, HbA1c 6.8 ± 1.0%), and they were divided into the "average or lower" (≤ 10 points), "high" (11-13 points) and "very high" (≥ 14 points) risk groups. We followed patients to observe all-cause death for 386 days (median). We compared the area under the curve (AUC) of the WATCH-DM score for predicting 1-year mortality with that of the Meta-Analysis Global Group in Chronic Heart Failure (MAGGIC) score and of the Barcelona Bio-Heart Failure Risk (BCN Bio-HF). Among the study patients, 108 patients (25.8%) had average or lower risk scores, 147 patients (35.2%) had high risk scores, and 163 patients (39.0%) had very high risk scores. The Cox proportional hazard model selected the WATCH-DM score as an independent predictor of all-cause death (HR per unit 1.10, 95% CI 1.03 to 1.19), and the "average or lower" risk group had lower mortality than the other groups (p = 0.047 by log-rank test). The AUC of the WATCH-DM for 1-year mortality was 0.64 (95% CI 0.45 to 0.74), which was not different from that of the MAGGIC score (0.72, 95% CI 0.63 to 0.80, p = 0.08) or that of BCN Bio-HF (0.70, 0.61 to 0.80, p = 0.25). The WATCH-DM risk score can estimate prognosis in T2DM patients with HFpEF and can identify patients at higher risk of mortality.


Assuntos
Diabetes Mellitus Tipo 2 , Insuficiência Cardíaca , Humanos , Masculino , Idoso , Idoso de 80 Anos ou mais , Diabetes Mellitus Tipo 2/complicações , Volume Sistólico , Fatores de Risco , Prognóstico
3.
Sci Rep ; 13(1): 22196, 2023 12 14.
Artigo em Inglês | MEDLINE | ID: mdl-38097659

RESUMO

The reproducibility of longitudinal strain measured by 2D speckle tracking echocardiography (2DSTE) may be affected by ultrasound settings. This study investigated the effect of transmit ultrasound frequency on global longitudinal strain (GLS) by 2DSTE. Apical, 2- and 4-chamber, and long-axis views were obtained in consecutive 162 patients using Philips ultrasound devices. Three different frequency presets were used sequentially: high resolution (HRES, 1.9 to 2.1 MHz), general (HGEN, 1.6 to 1.8 MHz), and penetration mode (HPEN, 1.3 to 1.6 MHz). GLS values were determined for each preset using the Philips Q-station software, resulting in GLS-HRES, GLS-HGEN, and GLS-HPEN. Among the 151 patients with successfully measured GLS, a significant difference in GLS was observed among the three presets (p < 0.0001). GLS-HRES (- 17.9 ± 4.4%) showed a slightly smaller magnitude compared to GLS-HGEN (- 18.8 ± 4.5%, p < 0.0001) and GLS-HPEN (- 18.8 ± 4.5%, p < 0.0001), with absolute differences of 1.1 ± 1.0% and 1.1 ± 1.2%, respectively. This variation in GLS with frequency was evident in patients with both optimal (n = 104) and suboptimal (n = 47) image quality and remained consistent regardless of ultrasound devices, ischemic etiology, or ejection fraction. In conclusion, ultrasound frequency had only a modest effect on GLS measurements. GLS may be reliably assessed in most cases regardless of the ultrasound frequency used.


Assuntos
Disfunção Ventricular Esquerda , Função Ventricular Esquerda , Humanos , Reprodutibilidade dos Testes , Deformação Longitudinal Global , Ecocardiografia/métodos , Software , Ventrículos do Coração/diagnóstico por imagem
4.
J Arrhythm ; 39(4): 523-530, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37560275

RESUMO

Background: Sleep apnea (SA) is highly prevalent and should be treated in patients referred for catheter ablation (CA) of atrial fibrillation (AF). Watch-type peripheral arterial tonometry (WP) for home SA testing has demonstrated a high correlation of the apnea-hypopnea index (AHI) with Polysomnography (PSG), but the evidence of its accuracy in AF patients is not adequate. Methods: This study was conducted under a retrospective, single-center, observational design. We included 464 consecutive AF patients (age 65 ± 11 years, 76.5% male, 45.0% paroxysmal-AF) who received both WP and PSG during the periprocedural period of the CA. We compared the AHI using the WP (WP-AHI) to that using PSG (PSG-AHI). Results: The WP-AHI was 25.9 ± 12.7 and PSG-AHI 31.4 ± 18.9 (r = .48). Among 325 patients with a WP-AHI < 30, 116 (35.7%) exhibited a PSG-AHI ≥ 30. Only 12.5% of the patients were indicated for continuous positive airway pressure (CPAP) treatment only by the WP-AHI, while 70.9% were indicated for CPAP by the PSG-AHI according to the Japanese health insurance system. The best cut-off value of the WP-AHI was 18.1 to predict a PSG-AHI ≥ 20 with an area under the curve of 0.72 (95% confidence interval, 0.67-0.76). Conclusions: The WP-AHI and PSG-AHI were weakly correlated in AF patients receiving CA. About one-third of the patients with moderate SA using the WP was diagnosed with severe SA evaluated by PSG. The majority required PSG for the CPAP indication.

6.
Cardiovasc Interv Ther ; 38(4): 395-405, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37184629

RESUMO

We developed the smallest diameter guide-extension catheter (GUIDE PLUS® 5Fr) to enable a new technique, the guide-extension proximal locking method (GP-Lock), and assessed its efficacy in the present experimental and clinical study. Sufficient guide catheter backup is sometimes crucial for PCI. We developed the KIWAMI-Lock direct anchoring method to obtain the strongest backup force by locking a Kiwami® 4Fr child catheter (Terumo Corp. Tokyo, Japan) directly to the coronary artery by ballooning from outside the child catheter. However, this method is complicated due to the requirement for a child catheter. We compared the backup power of the GP-Lock method and other conventional methods in an experimental study and compared the procedural outcomes of 17 cases treated using the initial GP-Lock method with 17 cases using the recent KIWAMI-Lock method before GP-Lock. The GP-Lock method had the highest backup force among the methods examined (GP-Lock: 293.7 ± 10.2 g force (gf), KIWAMI-Lock: 270.4 ± 12.9 gf, side branch balloon anchoring technique: 182.7 ± 8.1 gf, respectively, P < 0.0001). The preparation time was significantly shorter for the GP-Lock group than the KIWAMI-Lock group (5.0 [4.0, 5.0] min vs. 11.0 [8.0, 13.0] min, respectively, P < 0.001). The GP-Lock method makes it possible to easily obtain the strongest backup force, which can overcome situations where devices cannot pass through, especially in complex PCI procedures.


Assuntos
Intervenção Coronária Percutânea , Criança , Humanos , Intervenção Coronária Percutânea/métodos , Desenho de Equipamento , Catéteres , Cateterismo , Padrões de Referência , Resultado do Tratamento , Angiografia Coronária
7.
Am J Cardiol ; 191: 66-75, 2023 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-36641982

RESUMO

Functional mitral regurgitation (FMR) negatively impacts the prognosis in patients with atrial fibrillation (AF) and reduced left ventricular (LV) ejection fraction (LVEF). Although structural reverse remodeling after AF ablation can reduce FMR severity, the prognostic impact of FMR and its evolution remain unclear. Of 491 patients with baseline LVEF <50% who underwent first-time AF ablation, 134 patients (27%) had grade 2 to 4 FMR at baseline. Among them, 88 patients (66%) exhibited FMR improvement to grade 0 to 1 FMR 6 months after AF ablation. Conversely, among 357 with baseline grade 0 to 1 FMR, 13 patients (3.6%) exhibited FMR worsening to grade 2 to 4 FMR despite AF ablation. Assessment with multidetector computed tomography revealed that an increase in the left atrial emptying fraction (odds ratio 3.55 per 10% increase; 95% confidence interval 2.12 to 5.95) and a reduction in the LV end-diastolic volume index (1.35 per 10-ml/m2 decrease; 1.04 to 1.76) were identified as contributors to the FMR improvement. During a follow-up of 43 months, patients with postprocedural grade 2 to 4 FMR more frequently experienced hospitalizations for heart failure or cardiovascular death than those with grade 0 to 1 FMR (30.5% vs 4.6%, log-rank p <0.001). An age-adjusted multivariate Cox regression analysis including baseline and postprocedural FMR revealed that postprocedural grade 2 to 4 FMR (hazard ratio, 3.24; 95% confidence interval 1.43 to 7.35) was significantly associated with unfavorable events. In conclusion, AF ablation modified and often improved FMR severity in patients with reduced LVEF. Residual grade 2 to 4 FMR 6 months after AF ablation was associated with a poor prognosis.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Insuficiência da Valva Mitral , Disfunção Ventricular Esquerda , Humanos , Fibrilação Atrial/complicações , Fibrilação Atrial/cirurgia , Insuficiência da Valva Mitral/complicações , Insuficiência da Valva Mitral/cirurgia , Resultado do Tratamento , Prognóstico , Volume Sistólico
8.
Am J Cardiol ; 189: 108-118, 2023 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-36525835

RESUMO

The impact of rhythm outcomes on heart failure (HF) hospitalizations remains unknown after radiofrequency catheter ablation (RFCA) of atrial fibrillation (AF). We sought to elucidate whether AF recurrence was associated with HF hospitalizations after AF RFCA. We conducted a large-scale, prospective, multicenter, observational study (Kansai Plus Atrial Fibrillation Registry), enrolling 5,010 consecutive patients (age 64 ± 10 years, 27.3% female, and 35.7% nonparoxysmal AF) who underwent an initial AF RFCA at 26 centers. The median follow-up duration was 2.9 years. The cumulative 3-year incidence of HF hospitalizations after the initial RFCA was 1.84% (0.69%/year). Hospitalized patients with HF were older with a higher prevalence of nonparoxysmal AF, renal dysfunction, diabetes, and underlying heart disease pre-RFCA. HF hospitalizations occurred more often in patients with than without recurrences (3.27 vs 0.84%, log-rank p <0.0001). After adjusting for confounders using a Cox model, AF recurrence remained an independent predictor of HF hospitalizations (hazard ratio [HR] 2.84, 95% confidence interval [CI] 1.80 to 4.47, p <0.0001). AF recurrence was a distinct HF hospitalization risk in patients with a left ventricular ejection fraction ≥50% (HR 4.54, 95% CI 2.38 to 8.65, p <0.0001) but not <50% (HR 1.31, 95% CI 0.65 to 2.62, p = 0.45), with significant interactions. Furthermore, patients with AF recurrences within 1 year had a greater HF hospitalization risk after 1 year (1.61% vs 0.79%, log-rank p = 0.019). In conclusion, AF recurrence after RFCA was independently associated with HF hospitalizations.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Insuficiência Cardíaca , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Masculino , Fibrilação Atrial/complicações , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Volume Sistólico , Estudos Prospectivos , Função Ventricular Esquerda , Resultado do Tratamento , Sistema de Registros , Recidiva
9.
Heart Vessels ; 37(2): 315-326, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34342674

RESUMO

Left atrial (LA) function can help predict various cardiovascular events. Catheter ablation for atrial fibrillation (AF) modifies baseline LA function through the maintenance of sinus rhythm and myocardial injury. We investigated the impact of post-ablation LA function on recurrence of AF after ablation and identified the predictors of reduced post-ablation LA function. A total of 616 patients who underwent AF ablation (paroxysmal, N = 310; non-paroxysmal, N = 306) were retrospectively examined with cardiac computed tomography at baseline and 3 months after the final ablation procedure. Post-ablation LA emptying fraction (LAEFpost) was calculated. We evaluated the association between LAEFpost and recurrence of AF after the final ablation procedure. Further, we assessed the predictors of reduced LAEFpost. The recurrence rate of AF was 72.7% after the final ablation procedure [median follow-up 48 months (48.0, 48.0), total number of ablation sessions: 1.4 ± 0.7]. Multivariate analysis revealed that LAEFpost was associated with the recurrence of AF (hazard ratio/10% increase: 0.62, 95% confidence interval: 0.51-0.75, P < 0.0001). LAEFpost had a mild predictive power for recurrence of AF (c-statistics: 0.670, optimal cutoff: 26.36%, P < 0.0001). The recurrence-free proportion among patients with reduced LAEFpost (< 26.36%, N = 100) and those with preserved LAEFpost (≥ 26.36%, N = 516) was 40% and 79%, respectively (P < 0.0001). The predictors of reduced LAEFpost were low pre-ablation LAEF, high pre-ablation LA volume, low body mass index (BMI), and female sex. Further, reduced LAEFpost was associated with the total number of ablation sessions and extra-pulmonary vein LA ablation. In conclusion, reduced LAEFpost was associated with recurrence of AF after ablation. Advanced LA remodeling, low BMI, and female sex could predict reduced LAEFpost. Although additional ablation was associated with reduced LAEFpost, it remains unclear whether reduced LAEFpost resulted from the additional ablation. Reduced LAEFpost might help stratify patients with ablation-refractory AF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Função do Átrio Esquerdo , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Feminino , Átrios do Coração , Humanos , Recidiva , Estudos Retrospectivos , Resultado do Tratamento
10.
Heart Vessels ; 37(1): 99-109, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34374825

RESUMO

Red cell distribution width (RDW) is reportedly associated with cardiovascular events, including atrial fibrillation (AF). We investigated whether the RDW values were associated with the outcomes of catheter ablation for AF. This retrospective multicenter study included 501 patients with AF (239 paroxysmal AF cases, 196 persistent AF cases, and 66 long-standing persistent AF cases) who underwent initial AF ablation between March 2017 and May 2018. The RDW values were evaluated before and at 1-3 months after the procedure. The patients were stratified based on the recurrence of AF within 1 year after the index procedure with a blanking period of 3 months into recurrence group (107 patients, 21.4%) and no-recurrence group (394 patients, 78.6%). There were no significant differences in preoperative RDW values between the groups (p = 0.37). The RDW value did not change significantly after the ablation in the recurrence group (13.55-13.60%, p = 0.37), although it decreased significantly in the no-recurrence group (13.64-13.37%, p < 0.001). Multivariate Cox proportional hazards regression analyses revealed that a postoperative change in RDW (ΔRDW) was independently associated with AF recurrence (hazard ratio 2.00, 95% confidence interval 1.42-2.76, p < 0.001). Receiver operating characteristic curve analysis revealed that a ΔRDW cut-off value of - 0.1% provided a c-statistic of 0.65 for predicting AF recurrence. Decrease in RDW during the blanking period after ablation independently predicted the 1-year success of AF ablation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Índices de Eritrócitos , Humanos , Recidiva , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
11.
Cardiol J ; 29(3): 423-431, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34787888

RESUMO

BACKGROUND: Decreases in circulating CD34-positive cells are associated with increases in cardiovascular events. We investigated the association between the number of CD34-positive cells and the progression of coronary artery calcification (CAC), a marker of atherosclerosis, in patients with hypercholesteremia under statin therapy in a sub-analysis of a multicenter study. METHODS: In the principal study, patients with CAC scores of 1-999 were treated with pitavastatin. Measurement of CAC by non-enhanced computed tomography and a blood test were performed at baseline and at 1-year follow-up. Patients were divided into two groups: CAC progression (change in CAC score > 0) and non-progression. The number of circulating CD34-positive cells was counted using flow cytometry. RESULTS: A total of 156 patients (mean age 67 years, 55% men) were included in this sub-analysis. CD34 positive cell numbers at baseline as a continuous variable was inversely correlated with annual change in the log-transformed CAC score (r = -0.19, p = 0.02). When patients were divided into high and low CD34 groups based on the median value of 0.8 cells/µL, the adjusted change in CAC score in the low-CD34 group was significantly greater than that in the high-CD34 group (54.2% vs. 20.8%, respectively, p = 0.04). In multiple logistic analysis, a low CD34-positive cell number was an independent predictor of CAC progression, with an odds ratio of 2.88 (95% confidence interval 1.28-6.49, p = 0.01). CONCLUSIONS: Low numbers of CD34-positive cells are associated with CAC progression in patients with hypercholesterolemia under statin therapy. The number of CD34-positive cells may help to identify patients at increased cardiovascular risk.


Assuntos
Doença da Artéria Coronariana , Inibidores de Hidroximetilglutaril-CoA Redutases , Calcificação Vascular , Idoso , Doença da Artéria Coronariana/diagnóstico , Progressão da Doença , Feminino , Humanos , Inibidores de Hidroximetilglutaril-CoA Redutases/uso terapêutico , Masculino , Estudos Prospectivos , Fatores de Risco , Calcificação Vascular/diagnóstico por imagem
13.
J Arrhythm ; 37(6): 1468-1476, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34887951

RESUMO

BACKGROUND: Pulmonary vein (PV) reconnection is the main cause of atrial fibrillation (AF) recurrence. This study aimed to examine the effect of first-pass PV isolation (PVI) on PV reconnection frequency during the procedure and on AF ablation outcomes. METHODS: This retrospective study included 446 patients with drug-refractory AF (370 men, aged 64 ± 10 years) who underwent initial PVI using an open-irrigated contact force catheter between January 2015 and October 2016. We investigated the effect of first-pass PVI on PV reconnection during spontaneous PV reconnection and dormant conduction after an adenosine triphosphate challenge. RESULTS: First-pass PVI was achieved in 69% (617/892) of ipsilateral PVs, of which we observed PV reconnection during the procedure in 134 (22%) PVs. This value was significantly lower than that observed in those without first-pass PVI (50%, 138/275) (P < .0001). We divided the subjects into two groups based on the presence or absence of first-pass PVI in at least one of two ipsilateral PVs: first-pass (n = 383, 86%) and non-first-pass groups (n = 63, 14%). The 2-year AF recurrence-free rate was significantly higher in the first-pass group than in the other group (75% vs 59%, log-rank P = .032). In 78 patients with repeat AF ablation, the PV reconnection rate in the second procedure was significantly lower in PVs that had first-pass isolation in the first procedure (34% vs 73%, P < .0001). CONCLUSIONS: Absence of first-pass PVI was associated with a higher frequency of spontaneous PV reconnection and dormant conduction and poor ablation outcomes. First-pass isolation may be a useful marker for better PVI durability.

14.
JACC Case Rep ; 3(17): 1842-1848, 2021 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-34917965

RESUMO

During removal of an entrapped guidewire, the core wire can fracture, allowing stretching of the spring wire while the distal guidewire is still entrapped. We resolved this issue with rotational atherectomy, allowing cutting of the spring wire at the intended site, regardless of the proximal spring wire fracture. (Level of Difficulty: Advanced.).

15.
Circ Rep ; 3(9): 530-539, 2021 Sep 10.
Artigo em Inglês | MEDLINE | ID: mdl-34568632

RESUMO

Background: Global longitudinal strain (GLS) can predict prognosis after myocardial infarction (MI). Tissue mitral annular displacement (TMAD) is another index of longitudinal left ventricular deformity, and is less dependent on image quality than GLS. We investigated the relationship between TMAD and GLS, and their ability to predict outcomes after MI. Methods and Results: GLS and TMAD were measured on echocardiograms 2 weeks after MI in 246 consecutive patients (median age 62 years, 85.7% male). TMAD was measured from apical 4- and 2-chamber views (TMAD4ch and TMAD2ch, respectively), and a mean value (TMADav) was calculated. TMAD4ch, TMAD2ch, and GLS were successfully measured in 240 (97.5%), 210 (85.3%) and 214 patients (87.0%), respectively. All TMAD parameters were significantly correlated with GLS (R=0.71-0.75) and left ventricular ejection fraction (LVEF; R=0.48-0.53). TMAD parameters were weakly correlated with peak creatine kinase (CK; R=0.20) and CK-MB (R=0.21-0.25). GLS and TMADav were significantly associated with LVEF after 6 months (R=0.48-0.53) and all-cause mortality during the follow-up period (median 1,242 days). TMADav discriminated patients with higher all-cause mortality when patients were divided into 3 groups, namely upper 25%, middle range, and lower 25% of TMADav (P=0.041, log-rank test). GLS detected high-risk patients using 15.0% as a cut-off value. Conclusions: TMAD could be a simple and reliable alternative to GLS for predicting outcomes in patients with MI.

16.
IEEE Trans Biomed Eng ; 68(12): 3543-3553, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-33945468

RESUMO

OBJECTIVE: The elasticity of the aortic wall varies depending on age, vessel location, and the presence of aortic diseases. Noninvasive measurement will be a powerful tool to understand the mechanical state of the aorta in a living human body. This study aimed to determine the elastic modulus of the aorta using computed tomography images. METHODS: We constructed our original formulae based on mechanics of materials. Then, we performed computed tomography scans of a silicon rubber tube by applying four pressure conditions to the lumen. The segment elastic modulus was calculated from the scanned images using our formulae. The actual modulus was measured using a tensile loading test for comparison. RESULTS: The segment moduli of elasticity from the images were 0.525 [0.524, 0.527], 0.524 [0.520, 0.524], 0.520 [0.515, 0.523], and 0.522 [0.516, 0.532] (unit: MPa, median [25%, 75% quantiles]) for the four pressure conditions, respectively. The corresponding measurements in the tensile test were 0.548 [0.539, 0.566], 0.535 [0.528, 0.553], 0.526 [0.513, 0.543], and 0.523 [0.508, 0.530], respectively. These results indicated errors of 4.2%, 2.1%, 1.1%, and 0.2%, respectively. CONCLUSION: Our formulae provided good estimations of the segment elastic moduli of a silicon rubber tube under physiological pressure conditions using the computed tomography images. SIGNIFICANCE: In addition to the elasticity, the formulae provide the strain energy as well. These properties can be better predictors of aortic diseases. The formulae consist of clinical parameters commonly used in medical settings (pressure, diameter, and wall thickness).


Assuntos
Aorta , Tomografia Computadorizada por Raios X , Aorta/diagnóstico por imagem , Módulo de Elasticidade , Elasticidade , Humanos
17.
Am J Cardiol ; 144: 67-76, 2021 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-33385358

RESUMO

Catheter ablation (CA) of atrial fibrillation (AF) improves cardiac function, resulting in a decrease in plasma brain natriuretic peptide (BNP) levels in patients with reduced left ventricular ejection fraction (LVEF). This study sought to examine the pre-procedural and post-procedural correlations between BNP levels and cardiac function and the associations between the BNP levels and recurrence after CA in patients with AF and reduced LVEF. Of 3142 consecutive patients who underwent first-time CA of AF at our institute, a total of 217 patients with LVEF <50% were enrolled. Significant decrease in BNP levels (from a median of 198 [interquartile range 113 to 355] to 47.7 [22.7 to 135] pg/ml, p <0.001) and improvement in LVEF (from 39±9% to 61±16%, p <0.001) were observed 3 months after CA. There was a linear correlation between log-transformed BNP levels and cardiac measures (LVEF: r = -0.64; LV end-diastolic volume: r = 0.25; LV end-systolic volume: r = 0.43; left atrial volume: r = 0.52; all p <0.001). During a median follow-up of 35 months, AF recurrence after a 3-month blanking period was observed in 80 patients (37%). Cox proportional hazard regression analysis after adjustment for cardiac measures significant in univariate analysis revealed that early recurrence within the blanking period (hazard ratio, 4.88; 95% confidence interval, 2.89 to 8.25) and elevated post-procedural BNP levels (2.02 per unit log increase; 1.14 to 3.56) were significant predictors of AF recurrence, but pre-procedural BNP was not. In conclusion, post-procedural BNP levels at the end of the blanking period predicted subsequent AF recurrence in patients with reduced LVEF, independent of early recurrence.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Peptídeo Natriurético Encefálico/sangue , Disfunção Ventricular Esquerda/sangue , Idoso , Fibrilação Atrial/sangue , Fibrilação Atrial/complicações , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Recidiva , Resultado do Tratamento , Disfunção Ventricular Esquerda/complicações
18.
J Cardiol ; 77(5): 500-508, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33272779

RESUMO

BACKGROUND: Left ventricular (LV) reverse remodeling (LVRR) after catheter ablation of atrial fibrillation (AFCA) has not been fully described. This study investigated the predictors and clinical outcomes of LVRR after AFCA in patients with LV systolic dysfunction. METHODS: Of 3319 consecutive patients who underwent first-time AFCA between January 2012 and October 2019, 376 with a baseline LV ejection fraction of <50% were retrospectively evaluated. They were subjected to 256-slice multidetector computed tomography (MDCT) scanning at baseline and 3 months after AFCA. The LVRR was defined as a decrease in the LV end-systolic volume of ≥15%. RESULTS: The prevalence of LVRR was 83% (n = 306). Multivariate logistic regression analysis including age, body mass index, diabetic status, beta-blocker use, and LV diastolic diameter revealed that the predictors of LVRR were non-paroxysmal atrial fibrillation (AF) (odds ratio, 2.68; 95% confidence interval, 1.42-5.05; p = 0.002) and absence of apparent underlying structural heart disease (4.81; 2.31-10.0; p <0.001). The prevalence of LVRR differed depending on AF recurrence pattern prior to the post-MDCT [no episode vs. paroxysmal episode (lasting <7 days) vs. persistent episode (lasting ≥7 days), 84% vs. 81% vs. 63%, respectively, p = 0.023]. During a median follow-up of 32 months, the incidence of paroxysmal form of AF recurrence was similar, whereas persistent form of AF recurrence was less frequent in patients with LVRR (10.5% vs. 18.6%, p = 0.018). Heart failure hospitalizations (2.3% vs. 15.7%, p <0.001), cardiovascular deaths (0.7% vs. 4.3%, p = 0.015), and all-cause deaths (1.3% vs. 5.7%, p = 0.018) were similarly less frequent in those with LVRR. CONCLUSIONS: LVRR after AFCA, which was predicted by non-paroxysmal AF without any apparent structural heart disease at baseline, was associated with persistent form of AF recurrence prior to the evaluation. LVRR was associated with favorable clinical outcomes.


Assuntos
Fibrilação Atrial , Remodelamento Atrial , Ablação por Cateter , Disfunção Ventricular Esquerda , Fibrilação Atrial/complicações , Fibrilação Atrial/cirurgia , Humanos , Estudos Retrospectivos , Resultado do Tratamento , Disfunção Ventricular Esquerda/etiologia , Função Ventricular Esquerda , Remodelação Ventricular
19.
Circ J ; 85(3): 252-260, 2021 02 25.
Artigo em Inglês | MEDLINE | ID: mdl-33298643

RESUMO

BACKGROUND: Whether all atrial fibrillation (AF) patients should be evaluated for sleep apnea before catheter ablation (CA) remains controversial. Watch-type peripheral arterial tonometry (W-PAT) is a home sleep testing device and an easier tool for diagnosing sleep apnea than polysomnography. We investigated the prevalence and predictors of sleep apnea using W-PAT in unscreened sleep apnea patients with AF before CA.Methods and Results:The study was conducted under a retrospective, single-center, observational design. We included 776 consecutive patients who underwent both W-PAT and AF ablation. Sleep apnea assessments were successfully performed in 774 patients (99.7%; age 65±11 years, 73.3% male; body mass index [BMI] 24.1±3.5, 56.8% paroxysmal AF). The mean apnea-hypopnea index (AHI) was 20.1±15.6. Although 81.7% of the patients had normal Epworth sleepiness scores (mean 6.5), only 88 (11.4%) had a normal AHI (AHI <5) and 412 (53.2%) had moderate-severe sleep apnea (AHI ≥15). Obesity, male sex, nonparoxysmal AF, hypertension, and a left atrial diameter (LAd) ≥40 mm were predictors of moderate-severe sleep apnea. However, the prevalence of moderate-severe sleep apnea in patients without those predictors (i.e., non-obesity (44.2%), female sex (43.0%), paroxysmal AF (43.9%), no hypertension (45.5%)), and LAd <40 mm (41.0%) was considerably high. CONCLUSIONS: Almost all patients successfully underwent W-PAT to diagnose sleep apnea. Patients undergoing AF ablation had a high prevalence of sleep apnea, and screening for sleep apnea was important in those patients even if they did not have sleepiness or risk factors.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Síndromes da Apneia do Sono , Apneia Obstrutiva do Sono , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Obesidade , Estudos Retrospectivos , Fatores de Risco , Síndromes da Apneia do Sono/diagnóstico , Síndromes da Apneia do Sono/epidemiologia , Apneia Obstrutiva do Sono/diagnóstico , Apneia Obstrutiva do Sono/epidemiologia , Sonolência
20.
J Cardiol Cases ; 22(6): 294-298, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33304425

RESUMO

A 51-year-old man with normal left ventricular ejection fraction (LVEF) underwent radiofrequency catheter ablation (RFCA) for long-standing persistent atrial fibrillation (AF). After isolating the pulmonary veins (PV), we attempted to ablate multiple non-PV AF triggers evoked by isoproterenol and performed repetitive intracardiac electrical cardioversion under considerable dose of barbiturate. Finally, administration of pilsicainide was required to maintain sinus rhythm. Sixty minutes after the procedure, initiation of development of rapid ST-segment elevation was observed on the continuous electrocardiogram monitor and the patient complained of general fatigue. There was occurrence of complete atrioventricular block and he immediately fell into pulseless electrical activity (PEA). Cardiopulmonary resuscitation was initiated and a percutaneous cardiopulmonary system (PCPS) was provided. Echocardiogram showed severe biventricular systolic dysfunction. Although ST-segment change sustained, emergent coronary angiography was normal. Left ventriculogram showed apical to mid ventricular akinesia and preserved basal contractibility, which was typical of takotsubo syndrome (TS). Fortunately, he recovered completely; the PCPS was weaned on day 5, and the LVEF normalized within 2 weeks without any neurological disorders. This is the first case report of PEA due to TS following AF ablation. TS due to stressors of RFCA procedure should be recognized as a possible life-threatening complication. .

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...