Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Biomed Khim ; 70(5): 349-355, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39324199

RESUMO

This work demonstrates the use of a solid-state nanopore detector to monitor the activity of a single molecule of a model enzyme, horseradish peroxidase (HRP). This detector includes a measuring cell, which is divided into cis- and trans- chambers by a silicon nitride chip (SiN structure) with a nanopore of 5 nm in diameter. To entrap a single HRP molecule into the nanopore, an electrode had been placed into the cis-chamber; HRP solution was added into this chamber after application of a negative voltage. The reaction of the HRP substrate, 2,2-azino-bis(3-ethylbenzothiazoline-6-sulfonate) (ABTS), oxidation by the enzyme molecule was performed in the presence of hydrogen peroxide. During this reaction, the functioning of a single HRP molecule, entrapped in the nanopore, was monitored by recording the time dependence of the ion current flowing through the nanopore. The approach proposed in our work is applicable for further studies of functioning of various enzymes at the level of single molecules, and this is an important step in the development of single-molecule enzymology.


Assuntos
Peroxidase do Rábano Silvestre , Peróxido de Hidrogênio , Nanoporos , Peroxidase do Rábano Silvestre/química , Peroxidase do Rábano Silvestre/metabolismo , Peróxido de Hidrogênio/química , Benzotiazóis/química , Oxirredução , Ácidos Sulfônicos/química , Técnicas Biossensoriais/métodos , Técnicas Biossensoriais/instrumentação , Compostos de Silício/química
2.
Patol Fiziol Eksp Ter ; 61(2): 101-7, 2017.
Artigo em Russo | MEDLINE | ID: mdl-29215851

RESUMO

The purpose of the research consisted in detection of fluctuation of brightness temperature (TSHF) of water in the area of the temperature Т = 42°Ð¡ (that is critical for human) during its evaporation by SHF radiometry. Methods: Monitoring of the changes in brightness temperature of water in superhigh frequency (SHF) range (3.8-4.2 GHz) near the phase transition temperature of water Т = 42°Ð¡ during its evaporation in the cone dielectric cell. The brightness temperature measurements were carried out using radiometer. Results: Fluctuation with maximum of brightness temperature was detected in 3.8-4.2 GHz frequency range near at the temperature of water Т = 42°Ð¡. It was characteristic for these TSHF fluctuations that brightness temperature rise time in this range of frequencies in ~4°Ð¡ temperature range with 0.05-15°Ð¡/min gradient and a sharp decrease during 10 s connected with measuring vapor conditions. Then nonintensive fluctuation series was observed. At that, the environment temperature remained constant. Conclusion: The significant increasing in brightness temperature of water during its evaporation in SHF range near the temperature of Т ~42°Ð¡ were detected. It was shown that for water, ТSHF pull with the amplitude DТSHF ~4°C are observed. At the same time, thermodynamic temperature virtually does not change. The observed effects can be used in the development of the systems for diadnostics of pathologies in human and analytical system.


Assuntos
Temperatura Alta , Micro-Ondas , Água/química
3.
Biochem Biophys Rep ; 7: 20-25, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29114577

RESUMO

Monitoring of microwave emission from aqueous solution of horseradish peroxidase (HRP) in the process of the enzyme functioning was carried out. For the monitoring, a system containing HRP, luminol and Н2О2 was employed. Microwave emission measurements were carried out in the 3.4-4.2 GHz frequency range using the active and passive modes (active-mode and passive-mode measurements). In the active mode, excitation of the solution in the pulsed electromagnetic field was accomplished. In the passive mode, no excitation was induced. It appears that the passive-mode measurements taken in the course of the peroxidase reaction in the enzyme system have shown a 0.5 °Ð¡ increase of the microwave signal. Upon the active-mode measurements, taken in the same reaction conditions, the forced excitation of the solution has also led to the increase (by 2 °Ð¡) of the level of the microwave signal - i.e. to its 4-fold enhancement compared to the signal obtained in passive-mode measurements.

4.
Biomed Khim ; 61(4): 462-7, 2015.
Artigo em Russo | MEDLINE | ID: mdl-26350736

RESUMO

The nanowire (NW) detection is one of fast-acting and high-sensitive methods allowing to reveal potentially relevant protein molecules. A NW biosensor based on the silicon-on-insulator (SOI)-structures was used for biospecific label-free detection of NFAT 1 (D-NFAT 1) oncomarker in real time. For this purpose, SOI-nanowires (NWs) were modified with aptamers against NFAT 1 used as molecular probes. It was shown that using this biosensor it is possible to reach the sensitivity of ~10(-15) M. This sensitivity was comparable with that of the NW biosensor with immobilized antibodies used as macromolecular probes. The results demonstrate promising approaches used to form the sensor elements for high-sensitive disease diagnostics.


Assuntos
Aptâmeros de Nucleotídeos/química , Técnicas Biossensoriais/instrumentação , Fatores de Transcrição NFATC/análise , Nanofios/química , Proteínas de Neoplasias/análise , Anticorpos Monoclonais/química , Aptâmeros de Nucleotídeos/síntese química , Técnicas Biossensoriais/economia , Técnicas Eletroquímicas , Humanos , Limite de Detecção , Dióxido de Silício/química , Soluções , Succinimidas/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA