Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 67
Filtrar
1.
Pediatr Cardiol ; 39(6): 1265-1275, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29748699

RESUMO

In hypoplastic left heart syndrome (HLHS), long-term outcome is closely related to right ventricular function. Echocardiography and magnetic resonance imaging (MRI) are routinely used for functional assessment. MRI 2D-tissue feature tracking (2D-FT) allows quantification of myocardial deformation but has not yet been applied to HLHS patients. We sought to investigate the feasibility of this technique and to compare the results to 2D-speckle tracking echocardiography (2D-STE). In routine MRI 2D anatomical four chamber view, cine images were recorded in 55 HLHS patients (median age 4.9 years [1.6, 17.0]). Regional and global peak systolic longitudinal strain (LS) and strain rate (LSR) were determined using 2D-FT software. Echocardiographic four chamber view was analyzed with 2D-STE. Visualization of all myocardial segments with MRI was excellent, regional, and global LS and LSR could be assessed in all data sets. In 2D-STE, 28% of apical segments could not be analyzed due to poor image quality. Agreement of 2D-FT MRI and 2D-STE was acceptable for global LS, but poor for global LSR. In MRI, regional LS was lower in the septal segments, while LSR was not different between the segments. GLS and GLSR correlated with ejection fraction (GLS: r = - 0.45 and r < 0.001, GLSR: r = - 0.34 and p = 0.01). With new post-processing options, the assessment of regional and global LS and LSR is feasible in routine MRI of HLHS patients. For LS, results were comparable with 2D-STE. The agreement was poor for LSR, which might relate to differences in temporal resolution between the two imaging modalities.


Assuntos
Ecocardiografia/métodos , Ventrículos do Coração/diagnóstico por imagem , Síndrome do Coração Esquerdo Hipoplásico/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética/métodos , Adolescente , Criança , Pré-Escolar , Estudos de Viabilidade , Feminino , Ventrículos do Coração/fisiopatologia , Humanos , Síndrome do Coração Esquerdo Hipoplásico/complicações , Síndrome do Coração Esquerdo Hipoplásico/cirurgia , Lactente , Masculino , Miocárdio/patologia , Reprodutibilidade dos Testes , Função Ventricular Direita/fisiologia
2.
Eur J Pain ; 21(8): 1326-1335, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28440002

RESUMO

BACKGROUND: The effectiveness of Botulinum-neurotoxin A (BoNT/A) to treat pain in human pain models is very divergent. This study was conducted to clarify if the pain models or the route of BoNT/A application might be responsible for these divergent findings. METHODS: Sixteen healthy subjects (8 males, mean age 27 ± 5 years) were included in a first set of experiments consisting of three visits: (1) Visit: Quantitative sensory testing (QST) was performed before and after intradermal capsaicin injection (CAPS, 15 µg) on one thigh and electrical current stimulation (ES, 1 Hz) on the contralateral thigh. During stimulation pain and the neurogenic flare response (laser-Doppler imaging) were assessed. (2) Four weeks later, BoNT/A (Xeomin® , 25 MU) was injected intracutaneously on both sides. (3) Seven days later, the area of BoNT/A application was determined by the iodine-starch staining and the procedure of the (1) visit was exactly repeated. In consequence of these results, 8 healthy subjects (4 males, mean age 26 ± 3 years) were included into a second set of experiments. The experimental setting was exactly the same with the exception that stimulation frequency of ES was increased to 4 Hz and BoNT/A was injected subcutaneously into the thigh, which was stimulated by capsaicin. RESULTS: BoNT/A reduced the 1 Hz ES flare size (p < 0.001) and pain ratings (p < 0.01), but had no effect on 4 Hz ES and capsaicin-induced pain, hyperalgesia, or flare size, regardless of the depth of BoNT/A injection (i.c./s.c). Moreover, i.c. BoNT/A injection significantly increased warm detection and heat pain thresholds in naive skin (WDT, Δ 2.2 °C, p < 0.001; HPT Δ 1.8 °C, p < 0.005). CONCLUSION: BoNT/A has a moderate inhibitory effect on peptidergic and thermal C-fibers in healthy human skin. SIGNIFICANCE: The study demonstrates that BoNT/A (Incobotulinumtoxin A) has differential effects in human pain models: It reduces the neurogenic flare and had a moderate analgesic effects in low frequency but not high frequency current stimulation of cutaneous afferent fibers at C-fiber strength; BoNT/A had no effect in capsaicin-induced (CAPS) neurogenic flare or pain, or on hyperalgesia to mechanical or heat stimuli in both pain models. Intracutaneous BoNT/A increases warm and heat pain thresholds on naïve skin.


Assuntos
Toxinas Botulínicas Tipo A/uso terapêutico , Hiperalgesia/tratamento farmacológico , Neuralgia/tratamento farmacológico , Fármacos Neuromusculares/uso terapêutico , Adulto , Capsaicina , Estimulação Elétrica , Feminino , Temperatura Alta , Humanos , Hiperalgesia/etiologia , Injeções Intradérmicas , Masculino , Fibras Nervosas Amielínicas/efeitos dos fármacos , Neuralgia/etiologia , Medição da Dor , Limiar da Dor/efeitos dos fármacos , Fármacos do Sistema Sensorial , Adulto Jovem
3.
Eur J Pain ; 21(7): 1173-1185, 2017 08.
Artigo em Inglês | MEDLINE | ID: mdl-28263013

RESUMO

BACKGROUND: C-tactile (CT) afferents are unmyelinated low-threshold mechanoreceptors optimized for signalling affective, gentle touch. In three separate psychophysical experiments, we examined the contribution of CT afferents to pain modulation. METHODS: In total, 44 healthy volunteers experienced heat pain and CT optimal (slow brushing) and CT sub-optimal (fast brushing or vibration) stimuli. Three different experimental paradigms were used: Concurrent application of heat pain and tactile (slow brushing or vibration) stimulation; Slow brushing, applied for variable duration and intervals, preceding heat pain; Slow versus fast brushing preceding heat pain. RESULTS: Slow brushing was effective in reducing pain, whereas fast brushing or vibration was not. The reduction in pain was significant not only when the CT optimal touch was applied simultaneously with the painful stimulus but also when the two stimuli were separated in time. For subsequent stimulation, the pain reduction was more pronounced for a shorter time interval between brushing and pain. Likewise, the effect was more robust when pain was preceded by a longer duration of brush stimulation. Strong CT-related pain reduction was associated with low anxiety and high calmness scores obtained by a state anxiety questionnaire. CONCLUSIONS: Slow brushing - optimal for CT activation - is effective in reducing pain from cutaneous heating. The precise mechanisms for the pain relief are as yet unknown but possible mechanisms include inhibition of nociceptive projection neurons at the level of the dorsal horn as well as analgesia through cortical mechanisms. SIGNIFICANCE: Slow brushing stimuli - optimal for activation of C-tactile fibres - can reduce pain from cutaneous heating. No such effect was seen with fast brushing or vibration. These observations indicate the role of C-tactile fibres in pain modulation.


Assuntos
Mecanorreceptores/fisiologia , Fibras Nervosas Amielínicas/fisiologia , Dor , Psicofísica/métodos , Emoções , Temperatura Alta , Humanos , Medição da Dor , Pele , Tato , Vibração
4.
Int J Cardiol ; 227: 691-697, 2017 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-27816303

RESUMO

BACKGROUND: Conceptually the right ventricle (RV) is less suitable to support the Fontan circulation than the left (LV). After palliation of hypoplastic left heart syndrome (HLHS) involving aortic reconstruction during the Norwood procedure the RV is exposed to abnormal afterload. We studied ventricular function and ventriculo-arterial coupling in HLHS patients (RV) and Fontan patients with single LV morphology that did (LV+N) and did not (LV-N) undergo Norwood-type aortic reconstruction. METHODS: Eighty patients (55 RV, 8 LV+N, 17 LV- N) were simultaneously studied with the conductance-catheter and echocardiography 4.8 (0.9-22.9)years after Fontan completion. RESULTS: Ejection fraction (EF) was lowest in the HLHS group (RV 60.9±11.0 vs. LV+N 68.4±10.5 vs. LV-N 69.7±8.0, P=0.003) whereas end systolic elastance (Ees), i.e. ventricular contractility, and end diastolic stiffness (Eed) were highest (Ees: RV 3.38±2.2 vs. LV+N 2.3.±13.8 vs. LV-N 1.92±1.37mmHg/ml, P=0.02; Eed: RV 0.59±0.36 vs. LV+N 0.48±0.29 vs. LV-N 0.32±0.17mmHg/ml, P<0.02). Arterial elastance, a measure of afterload, was highest in HLHS patients and correlated positively with Ees and Eed and inversely with EF in the study cohort. Only long axis function analysis suggested superior ventricular function in HLHS patients whereas all other echocardiographic measures did not reveal any group differences. CONCLUSION: Ventricular contractility of the RV of HLHS patients is higher than that of the ventricle of Fontan patients with LV morphology. This likely reflects a physiological response to higher arterial elastance resulting from aortic arch reconstruction. Increased arterial elastance negatively impacts diastolic stiffness, which is higher in the systemic RV than LV.


Assuntos
Técnica de Fontan/tendências , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Síndrome do Coração Esquerdo Hipoplásico/diagnóstico por imagem , Síndrome do Coração Esquerdo Hipoplásico/fisiopatologia , Função Ventricular Esquerda/fisiologia , Adolescente , Adulto , Cateterismo Cardíaco/tendências , Criança , Pré-Escolar , Feminino , Seguimentos , Ventrículos do Coração/cirurgia , Humanos , Síndrome do Coração Esquerdo Hipoplásico/cirurgia , Masculino , Procedimentos de Norwood/tendências , Estudos Prospectivos , Adulto Jovem
5.
Eur J Pain ; 19(7): 966-72, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25395191

RESUMO

BACKGROUND: Triptans are agonists to 5-HT 1B/D/F receptors, which are present on nociceptive neurons not only within but also beyond the trigeminal system. The aim of this study was to investigate whether zolmitriptan interacts with peptidergic nociceptive afferents in human skin. METHODS: Twenty participants (13 women, median age: 25; interquartile range: 23-26 years) entered the randomized, double-blind, cross-over study. Electrically induced neurogenic flare and pain was assessed after either placebo or zolmitriptan on the ventral thigh. Mechanical pain thresholds were investigated at baseline and after electrical stimulation at the stimulation site. RESULTS: The size of the neurogenic flare (F = 10.9; p = 0.002) as well as electrically induced pain were significantly reduced by zolmitriptan (F = 4.46; p = 0.041). Moreover, electrically induced pinprick hyperalgesia was significantly decreased by zolmitriptan compared with placebo (F = 6.243; p = 0.017). CONCLUSIONS: Triptans may have effects outside of the trigeminal system and reduce electrically evoked neurogenic inflammation and pain in human skin.


Assuntos
Inflamação Neurogênica/prevenção & controle , Oxazolidinonas/farmacologia , Dor/prevenção & controle , Agonistas do Receptor de Serotonina/farmacologia , Pele , Triptaminas/farmacologia , Adulto , Estudos Cross-Over , Método Duplo-Cego , Estimulação Elétrica , Feminino , Humanos , Masculino , Transtornos de Enxaqueca/tratamento farmacológico , Neurônios Aferentes/efeitos dos fármacos , Nociceptores/efeitos dos fármacos , Medição da Dor , Limiar da Dor/efeitos dos fármacos , Estimulação Física , Adulto Jovem
6.
Handchir Mikrochir Plast Chir ; 44(3): 142-6, 2012 Jun.
Artigo em Alemão | MEDLINE | ID: mdl-22833067

RESUMO

State of the art CRPS therapy comprises medication, interventional therapies and non-pharmaceutical treatments like physiotherapy (PT), occupational therapy, PT with cognitive behavioural elements (mirror therapy, 'motor imagery', and 'graded exposure'), psychotherapeutic methods, local therapies and neurostimulation. These treatments are mostly as successful as medical or interventional treatment. These effects have been demonstrated in small but randomised controlled studies. Adjuvant therapies were shown to reduce pain and the severity of dysfunction in CRPS. Therefore, these non-drug therapies should be an essential part of any multimodal CRPS treatment.


Assuntos
Distrofia Simpática Reflexa/reabilitação , Terapia Comportamental/métodos , Terapia Combinada , Humanos , Imaginação , Terapia Ocupacional , Modalidades de Fisioterapia , Psicoterapia , Ensaios Clínicos Controlados Aleatórios como Assunto , Distrofia Simpática Reflexa/diagnóstico , Estimulação da Medula Espinal , Estimulação Elétrica Nervosa Transcutânea , Resultado do Tratamento
8.
Radiologe ; 50(9): 799-806, 808, 2010 Sep.
Artigo em Alemão | MEDLINE | ID: mdl-20617299

RESUMO

Cardiovascular magnetic resonance imaging (CMR) has become a routinely used imaging modality for congenital heart disease. A CMR examination allows the assessment of thoracic anatomy, global and regional cardiac function, blood flow in the great vessels and myocardial viability and perfusion. In the clinical routine cardiovascular MRI is mostly performed at field strengths of 1.5 Tesla (T). Recently, magnetic resonance systems operating at a field strengths of 3 T became clinically available and can also be used for cardiovascular MRI. The main advantage of CMR at 3 T is the gain in the signal-to-noise ratio resulting in improved image quality and/or allowing higher acquisition speed. Several further differences compared to MRI systems with lower field strengths have to be considered for practical applications. This article describes the impact of CMR at 3 T in patients with congenital heart disease by meanings of methodical considerations and case studies.


Assuntos
Cardiopatias Congênitas/patologia , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Miocárdio/patologia , Adulto , Criança , Humanos
9.
Klin Padiatr ; 222(1): 3-12, 2010.
Artigo em Alemão | MEDLINE | ID: mdl-20084585

RESUMO

In today's clinical practice cardiovascular magnetic resonance (CMR) imaging is increasingly used for assessment of congenital and acquired heart disease in children. CMR complements echocardiography and provides a noninvasive alternative to diagnostic cardiac catheterization. In contrast to echocardiography, CMR is not limited by acoustic windows, and unlike cardiac catheterization, CMR lacks ionizing radiation. Contiguous three and four dimensional data sets allow to display cardiac and thoracic vessel anatomy in any desired imaging plane. These characteristics provide unique images for the complete depiction of the pathological anatomy in particular in congenital heart disease. Furthermore CMR is also used for assessment of cardiac function, blood-flow measurements, tissue characterization, and, more recently, for evaluation of myocardial perfusion and viability. The following article reviews CMR indications in pediatric cardiology by means of clinical examples.


Assuntos
Cardiomiopatias/diagnóstico , Cardiopatias Congênitas/diagnóstico , Neoplasias Cardíacas/diagnóstico , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Angiografia por Ressonância Magnética , Imageamento por Ressonância Magnética , Adolescente , Criança , Pré-Escolar , Ecocardiografia , Feminino , Humanos , Lactente , Masculino , Síndrome de Marfan/diagnóstico , Síndrome de Linfonodos Mucocutâneos/diagnóstico , Sensibilidade e Especificidade
10.
Catheter Cardiovasc Interv ; 73(7): 949-55, 2009 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-19455678

RESUMO

OBJECTIVE: To assess feasibility, safety, and efficacy of the use of Amplatzer occluders in closure of atrial septal defects (ASD) in children in the first 2 years of life. BACKGROUND: Although scattered reports on such closure have been published, no agreement consists on the policy. METHODS: In 654 patients of all ages, closure was achieved in 632 (96.6%). Data were analyzed retrospectively in all 71 children where an attempt had been made to close the ASD before their second birthday. RESULTS: Median age and body weight were 17.2 months (range 3.9-23.8) and 10.0 kg (range 3.8-14.5), respectively. Median fluoroscopy time was 13.6 min and median device size 15 mm. Successful closure was achieved in 68 children (95.8%). Three times the procedure was aborted: in one, the device repeatedly straddled the septum; in the other two, a small left atrium restricted the movement of the left-sided disc. One device embolized and was reimplanted after retrieval. One infant with multiple disorders died 6 days after closure from acute sepsis probably unrelated to the procedure. No other complications occurred. Only trivial shunts closing with time were registered during follow-up. Symptomatic patients profited markedly from closure. CONCLUSION: The results and complications of ASD closure with the Amplatzer device in patients in their first 2 years of life compare favorably with procedures in older patients, provided that the size of the septum and the dimensions in the left atrium are taken into consideration when selecting the size of the device.


Assuntos
Cateterismo Cardíaco/instrumentação , Comunicação Interatrial/terapia , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/mortalidade , Criança , Pré-Escolar , Desenho de Equipamento , Estudos de Viabilidade , Feminino , Alemanha , Comunicação Interatrial/diagnóstico por imagem , Comunicação Interatrial/mortalidade , Humanos , Lactente , Masculino , Noruega , Seleção de Pacientes , Radiografia Intervencionista , Estudos Retrospectivos , Medição de Risco , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia
11.
Pain ; 143(1-2): 97-105, 2009 May.
Artigo em Inglês | MEDLINE | ID: mdl-19269743

RESUMO

Pain memory is thought to affect future pain sensitivity and thus contribute to clinical pain conditions. Systematic investigations of the human capacity to remember sensory features of experimental pain are sparse. In order to address long-term pain memory, nine healthy male volunteers received intradermal injections of three doses of capsaicin (0.05, 1 and 20 microg, separated by 15 min breaks), each given three times in a balanced design across three sessions at one week intervals. Pain rating was performed using a computerized visual analogue scale (0-100) digitized at 1/s, either immediately online or one hour or one day after injection. Subjects also recalled their pains one week later. Capsaicin injection reliably induced a dose-dependent flare (p<0.001) without any difference within or across sessions. The strong burning pain decayed exponentially within a few minutes. Subjects were able to reliably discriminate pain magnitude and duration across capsaicin doses (both p<0.001), regardless of whether first-time ratings were requested immediately, after one hour or after one day. Pain recall after one week was similarly precise (magnitude: p<0.01, duration: p<0.05). Correlation with rating recall after one week was best when first-time ratings were requested as late as one day after injection (R(2)=0.79) indicating that both rating retrievals utilized similar memory traces. These results indicate a reliable memory for magnitude and duration of experimentally induced pain. The data further suggest that the consolidation of this memory is an important interim stage, and may take up to one day.


Assuntos
Capsaicina , Discriminação Psicológica , Memória de Curto Prazo , Limiar da Dor/fisiologia , Dor/induzido quimicamente , Dor/fisiopatologia , Adaptação Fisiológica , Humanos , Masculino , Fármacos do Sistema Sensorial , Adulto Jovem
12.
Neurology ; 72(6): 505-12, 2009 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-19204260

RESUMO

OBJECTIVE: To investigate clinical differences in warm and cold complex regional pain syndrome (CRPS) phenotypes. BACKGROUND: CRPS represents inhomogeneous chronic pain conditions; approximately 70% patients with CRPS have "warm" affected limbs and 30% have "cold" affected limbs. METHODS: We examined 50 patients with "cold" and "warm" CRPS (n = 25 in each group). Both groups were matched regarding age, sex, affected limb, duration of CRPS, and CRPS I and II to assure comparability. Detailed medical history and neurologic status were assessed. Moreover, quantitative sensory testing (QST) was performed on the affected ipsilateral and clinically unaffected contralateral limbs. RESULTS: Compared with patients who had warm CRPS, patients who had cold CRPS more often reported a history of serious life events (p < 0.05) and chronic pain disorders (p < 0.05). In cold CRPS, the incidence of CRPS-related dystonia was increased (p < 0.05), and cold-induced pain had a higher prevalence (p < 0.01). Furthermore, QST revealed a predominant sensory loss in patients with cold CRPS (p < 0.05). In contrast, patients with warm CRPS were characterized by mechanical hyperalgesia (p < 0.05) in the QST of affected limbs. CONCLUSION: Our results indicate that warm and cold complex regional pain syndromes (CRPS) are associated with different clinical findings, beyond skin temperature changes. This might have implications for the understanding of CRPS pathophysiology.


Assuntos
Temperatura Baixa , Síndromes da Dor Regional Complexa/classificação , Síndromes da Dor Regional Complexa/fisiopatologia , Temperatura Alta , Sensação , Temperatura Cutânea , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
13.
Br J Radiol ; 80(951): 177-85, 2007 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-16916806

RESUMO

European states within the EEC are required to establish and use diagnostic reference levels (DRLs) in X-ray examinations. However, up to now there have been no DRLs for cardiac catheterization in children, nor as a rule is the effective dose estimated. We have evaluated the dose-area products (DAPs) for three different types of angiocardiography systems over a time span of 8 years. For each system DAP increased in proportion to the body weight (BW) over two orders of magnitude. The proportionality constant decreased over the years. To reduce the broad distribution of DAP the doses for cine acquisition (DAPA) and fluoroscopy (DAPF) were indexed with respect to the total numbers of acquired images (AN) and the total times of fluoroscopy (FT). DAPA/AN is directly proportional to BW with a high correlation (r = 0.896, n = 1346). Likewise, DAPF/FT is proportional to BW from 0.1 kg to 100 kg (r = 0.84, n = 2138). Therefore, by normalizing DAP to BW the growth dependent variation of DAP can be eliminated. There are numerous short examinations with very small total DAPs, which were separated from the group of diagnostic examinations. The mean DAP/BW of this group is 0.41 Gycm2 kg(-1) (90th percentile: 0.81 Gycm2 kg(-1), n = 1106). For interventional procedures in congenital heart diseases DAP/BW is significantly higher (p<0.001) (mean: 0.56 Gycm2 kg(-1), 90th percentile: 1.16 Gycm2 kg(-1), n = 883). There are significant differences between different types of interventional procedures, the mean values being between 0.35 Gycm2 kg(-1) (occlusion of patent ductus botalli, n = 165) and 1.30 Gycm2 kg(-1) (occlusion of ventricular septal defect, n = 32). For patients who are catheterized several times over the years, the cumulative effective dose (E) may reach high values, being especially high for patients with hypoplastic left heart syndrome (typically 11 mSv). E is derived from DAP/BW by use of a constant DAP/BW to E conversion factor, independent of the age of the patient. DAP/BW is appropriate to describe paediatric DRLs and is recommended instead of using mean DAP values for age groups.


Assuntos
Cateterismo Cardíaco/normas , Radiografia Intervencionista/normas , Adolescente , Adulto , Idoso , Angiografia/métodos , Angiografia/normas , Peso Corporal , Cateterismo Cardíaco/métodos , Criança , Pré-Escolar , União Europeia , Fluoroscopia/métodos , Fluoroscopia/normas , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/cirurgia , Humanos , Lactente , Recém-Nascido , Pessoa de Meia-Idade , Doses de Radiação , Radiografia Intervencionista/métodos , Valores de Referência
14.
Exp Neurol ; 195(1): 179-84, 2005 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-15963503

RESUMO

Neutral endopeptidase (NEP) and angiotensin-converting enzyme (ACE) are involved in neuropeptide degradation and may modulate neurogenic inflammation. We therefore explored the effect of specific blockers of NEP and ACE on the intensity of neurogenic inflammation. We investigated eight subjects on three occasions. Two pairs of microdialysis fibers equipped with intraluminal wires were inserted intracutaneously into the volar forearms and electrical stimuli were delivered via the intraluminal electrodes. The microdialysis fibers were perfused either with normal saline, phosphoramidon (NEP inhibitor), or captopril (ACE inhibitor). CGRP release was assessed in the microdialysis eluate via a specific EIA and by evaluating the extent and intensity of the neurogenic flare via a laser Doppler imager. The area of hyperalgesia and allodynia was assessed during electrical stimulation. Inhibition of NEP with phosphoramidon increased flare intensity (P < 0.002) and size (P < 0.01), while blocking ACE had no effect on neurogenic vasodilation. CGRP release could be measured in microdialysis samples after phosphoramidon perfusion only (P < 0.03), not in samples with captopril or saline perfusion. No effect on the areas of hyperalgesia and allodynia could be detected. Our findings suggest that NEP but not ACE is most important for CGRP degradation in human skin. This may be of particular importance for the understanding of pain disorders like migraine or complex regional pain syndrome.


Assuntos
Captopril/efeitos adversos , Inibidores Enzimáticos/efeitos adversos , Glicopeptídeos/farmacologia , Neprilisina/antagonistas & inibidores , Inflamação Neurogênica/induzido quimicamente , Adulto , Peptídeo Relacionado com Gene de Calcitonina/metabolismo , Captopril/farmacologia , Interações Medicamentosas , Estimulação Elétrica/efeitos adversos , Inibidores Enzimáticos/farmacologia , Feminino , Humanos , Hiperalgesia/fisiopatologia , Técnicas Imunoenzimáticas/métodos , Fluxometria por Laser-Doppler/métodos , Masculino , Microdiálise/métodos , Fibras Nervosas Amielínicas/efeitos da radiação , Peptidil Dipeptidase A/farmacologia , Pele/inervação , Pele/fisiopatologia , Fatores de Tempo , Vasodilatação/efeitos dos fármacos , Vasodilatação/efeitos da radiação
15.
J Neurol ; 252(3): 315-20, 2005 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-15726269

RESUMO

BACKGROUND: The course of advanced diabetic neuropathy (DN) is largely unknown. AIM: To find variables allowing the follow-up of late stages of DN. METHODS: Thirty diabetic patients with DN were observed. Patients were examined at intervals of 6 months over a period of 2 years. The compound muscle action potentials (CMAPs) were recorded in extensor digitorum brevis (EDB) and flexor hallucis brevis (FHB) muscles. Clinical severity of DN, nerve conduction studies (NCS), quantitative sensory testing (QST) and heart rate variability (HRV) were evaluated. The data were compared with age- and sex-matched controls. RESULTS: All measures were sensitive to the detection of DN. Significant deterioration during follow-up was exclusively found in CMAP analysis of the EDB (p<0.05) and FHB muscles (p<0.03). NCS, QST and HRV remained unchanged within the 2 years of observation. Coincidental changes might occur, if only two time points are chosen for followup. CONCLUSION: Our results indicate that ongoing axonopathy predominates in advanced DN. Repeated testing helps to minimize the impact of coincidental or chance changes in DN follow-up studies.


Assuntos
Nefropatias Diabéticas/fisiopatologia , Músculo Esquelético/fisiopatologia , Condução Nervosa/fisiologia , Potenciais de Ação/fisiologia , Potenciais de Ação/efeitos da radiação , Análise de Variância , Estudos de Casos e Controles , Estimulação Elétrica/métodos , Eletromiografia/métodos , Feminino , Seguimentos , Frequência Cardíaca/fisiologia , Frequência Cardíaca/efeitos da radiação , Humanos , Masculino , Pessoa de Meia-Idade , Condução Nervosa/efeitos da radiação , Limiar Sensorial/fisiologia , Limiar Sensorial/efeitos da radiação , Índice de Gravidade de Doença , Fatores de Tempo
16.
Rofo ; 176(6): 859-61, 2004 Jun.
Artigo em Alemão | MEDLINE | ID: mdl-15173980

RESUMO

According to national and international rules the x-ray exposure of cardiac catheter examinations have to be measured. For a Philips Integris angiographic system used for paediatric heart catheterization we found severe errors in the indicated time of fluoroscopy and total dose area product ( DAP) both for fluoroscopy and radiography. Fluoroscopy times shorter than 6 seconds and DAPs smaller than 0.1 Gy cm (2) are ignored and not considered in the indicated total fluoroscopy time and the fluoroscopic and radiographic DAPs. This error leads to a systematic underestimation of the risk of radiation-induced cancer especially with infants and children.


Assuntos
Erros de Diagnóstico , Coração/diagnóstico por imagem , Radiografia/efeitos adversos , Criança , Angiografia Coronária/efeitos adversos , Humanos , Reprodutibilidade dos Testes
17.
Br J Radiol ; 77(918): 479-87, 2004 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15151968

RESUMO

In the paediatric cardiac catheterization laboratory the reduction of the radiation dose of diagnostic and interventional procedures is of high priority. Therefore, we performed an experimental study for optimizing the automatic exposure control (AEC) for cardiac angiography. With a Philips Integris BH 5000 system, six AEC programs were configured to acquire X-ray images of 8 cm to 18.5 cm thick PMMA phantoms at tube voltages between 50 kV and 90 kV, with 0.2 mm or 0.4 mm Cu filters and with or without an anti-scatter grid. At constant detector dose, entrance dose (ED) and image quality were evaluated as functions of the voltage. Changes in image quality were determined by the differential signal-to-noise ratio measured within regions of low (SNRb) and high (SNRd) attenuation. At equal voltages, ED saving was approximately 29% with the 0.4 mm Cu beam filtering as compared with 0.2 mm Cu, largely independent of object thickness. SNRb and SNRd were only dependent on the voltage. While SNRb was high at low voltages, SNRd showed a maximum at approximately 79 kV. Using a grid, ED increased with increasing object thickness by a factor of 1.9 to 3.5. At equal voltages, the grid led to significant image improvements, with SNRb and SNRd increasing by 27% and 11%, respectively. SNRb and SNRd are useful descriptors of the image quality in cardiac angiography. Highest image quality was found with tube voltages between 55 kV and 77 kV, independently of object thickness. To minimize dose, the thickness of the copper filter should be chosen to be as large as possible provided the tube's power limit allows keeping the voltage below the upper limit. In view of the substantial image improvement, the use of a grid is recommended for all patients, even for newborns.


Assuntos
Angiocardiografia/métodos , Doses de Radiação , Angiocardiografia/normas , Cateterismo Cardíaco/métodos , Criança , Humanos , Aumento da Imagem/métodos , Aumento da Imagem/normas , Imagens de Fantasmas , Radiografia Intervencionista/métodos , Espalhamento de Radiação , Ecrans Intensificadores para Raios X , Raios X
18.
J Neurol ; 250(2): 188-93, 2003 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-12574949

RESUMO

Botulinum toxin A (BoNT/A) has been used therapeutically to treat muscular hypercontractions and sudomotor hyperactivity. There is increasing evidence that BoNT/A might also have analgesic properties, in particular in headache. In the present investigation we tested the often cited hypothesis that BoNT/A-induced analgesia can be attributed to inhibition of neuropeptide release from nociceptive nerve fibers. In 15 healthy volunteers BoNT/A (5, 10, 20 mouse units BOTOX) or saline (contralateral side) was injected intracutaneously on the volar forearm. On day zero, the day of injection, no further tests were performed. We repeatedly elicited pain, mechanical hyperalgesia and neurogenic flare by transcutaneous electrical stimulation simultaneously on the BoNT/A and saline treated side on day 1, 2, 3, 7 and 14 after injection. Before each session, sweating and local anhidrosis was assessed by iodine starch staining.BoNT/A suppressed sweating as early as from the second day after injection (p < 0.001). The size of electrically induced flare was smaller on the BoNT/A treated arm (BoNT/A side: 21.46 cm(2) +/- 3.58, saline side 24.80 +/- 3.46, p < 0.005) and BoNT/A reduced electrically-induced pain by about 10 % (p < 0.001). However, hyperalgesia to pin-prick and allodynia after electrical stimulation were unchanged. In conclusion our results indicate that peripheral neuropeptide release is attenuated by BoNT/A. In contrast, the analgesic effect of BoNT/A was very limited. Therefore we assume that other than neuropeptide mechanisms must be important for BoNT/A induced pain relief in clinical pain syndromes.


Assuntos
Toxinas Botulínicas Tipo A/uso terapêutico , Hiperalgesia/tratamento farmacológico , Inflamação Neurogênica/tratamento farmacológico , Dor/tratamento farmacológico , Adulto , Axônios/efeitos dos fármacos , Axônios/patologia , Estimulação Elétrica , Feminino , Humanos , Hipo-Hidrose/induzido quimicamente , Masculino , Fibras Nervosas/efeitos dos fármacos , Fibras Nervosas/metabolismo , Inflamação Neurogênica/patologia , Nociceptores/efeitos dos fármacos , Nociceptores/metabolismo , Medição da Dor/efeitos dos fármacos , Psicofísica , Pele/inervação , Pele/patologia
19.
Heart ; 89(2): 199-204, 2003 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-12527678

RESUMO

AIM: To evaluate the safety and efficacy of transcatheter closure of secundum atrial septal defects (ASD) with the Amplatzer septal occluder. METHODS: 236 consecutive patients with a significant ASD (age 6 months to 46 years, median 5 years; body weight 6.5-79 kg, median 18 kg) were considered for transcatheter closure with the Amplatzer septal occluder; 18 patients with defects that were too large or with a deficient inferior margin were excluded from attempted transcatheter closure after initial transthoracic (4) or transoesophageal echocardiography (14). RESULTS: At cardiac catheterisation, devices were not implanted in 18 patients because the stretched diameter of the ASD was too large (4), the device was unstable (4), compromised the mitral valve (1), or obstructed the upper right pulmonary vein (1); eight patients with additional systemic or pulmonary vein anomalies (5) or a Qp:Qs less than 1.5 (3) were excluded after angiographic and haemodynamic assessment. Thus ASD closure was done successfully in 200 patients (procedure time 25-210 minutes, median 66 minutes; fluoroscopy time 2.5-60 minutes, median 12 minutes), among whom 22 had multiple ASDs (14) or a septal aneurysm (8). The diameter of the devices ranged between 6-34 mm. Severe procedure related complications (retroperitoneal bleeding, air embolism) occurred in two cases. At follow up (33 days to 4.3 years, median 2.3 years) complete closure was documented in 94%, with a trivial residual shunt in 12 patients. CONCLUSIONS: The Amplatzer septal occluder is very efficient and offered interventional ASD closure in 84.7% of our group of consecutive patients, with excellent intermediate results.


Assuntos
Oclusão com Balão/instrumentação , Embolização Terapêutica/instrumentação , Comunicação Interatrial/terapia , Adolescente , Adulto , Implante de Prótese Vascular/métodos , Cateterismo Cardíaco/métodos , Criança , Pré-Escolar , Ecocardiografia Transesofagiana/métodos , Humanos , Lactente , Pessoa de Meia-Idade , Resultado do Tratamento
20.
Biomed Tech (Berl) ; 47 Suppl 1 Pt 2: 622-5, 2002.
Artigo em Alemão | MEDLINE | ID: mdl-12465256

RESUMO

Compared to single plane angiographic systems, biplane systems offer the possibility of a merged evaluation of the two x-ray projections. A computer program was developed that allows the assessment of enddiastolic and endsystolic volumes and frame-by-frame analysis of the left and right ventricle based on representing the biplane angiograms as optimal paired images. Optimal pairing means the magnifications are fitted, resulting in identical scales for objects located in the isocenter of the gantry; furthermore the images are rotated such that paired epipolar lines in both planes represent the same cross section of a centered object. The improved border tracing is proved by comparing the vertical extents from the lateral and frontal projection of the right ventricle. The standard deviation of the differences were significantly (p < 0.01) reduced as compared to the generally used unpaired evaluation.


Assuntos
Angiografia/métodos , Volume Cardíaco/fisiologia , Ventrículos do Coração/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Criança , Cardiopatias Congênitas/diagnóstico por imagem , Humanos , Sensibilidade e Especificidade , Software
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...