Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
2.
Sci Rep ; 12(1): 12468, 2022 07 21.
Artigo em Inglês | MEDLINE | ID: mdl-35864273

RESUMO

To investigate whether combining L1-regularized iterative sensitivity encoding (SENSE) reconstruction and single-shot echo planar imaging (EPI) is useful in hepatic DWI. Single-shot EPI-DWI with L1-regularized iterative SENSE reconstruction (L1-DWI) and conventional parallel imaging-based reconstruction (conv-DWI) in liver MRI were compared in volunteers and patients. For the patient cohort, 75 subjects (60 ± 13 years) with 349 focal liver lesions (FLL) were included. Patient groups A and B were used to reduce acquisition time or improve spatial resolution, respectively. Image parameters were rated on a 5-point scale. The number of FLLs was recorded; in case of discrepancy, the reason for non-detectability was analyzed. In volunteers, higher signal-to-noise ratio (24.4 ± 5.6 vs. 12.2 ± 2.3, p < 0.001 at b = 0; 19.3 ± 2.8 vs. 9.8 ± 1.6, p < 0.001 at b = 800) and lower standard deviation of the apparent diffusion coefficient-values (0.17 vs. 0.20 mm2/s, p < 0.05) were found on L1-DWI compared to conv-DWI. In patients, image ratings were similar for all parameters except for "conspicuity of FLLs" which was rated significantly lower on L1-DWI vs. conv-DWI (4.7 ± 0.6 vs. 4.2 ± 0.9, p < 0.05) in group A. In five patients, 11/349 FLLs were not detectable on L1-DWI, but on conv-DWI. L1-regularized iterative reconstruction of single-shot EPI DWI can accelerate image acquisition or improve spatial resolution. However, our finding that FLLs were non-detectable on L1-DWI warrants further research.


Assuntos
Imagem de Difusão por Ressonância Magnética , Imagem Ecoplanar , Imagem de Difusão por Ressonância Magnética/métodos , Imagem Ecoplanar/métodos , Humanos , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Reprodutibilidade dos Testes , Razão Sinal-Ruído
3.
Am J Sports Med ; 50(8): 2203-2210, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35666098

RESUMO

BACKGROUND: Retears after rotator cuff repair (RCR) have been associated with poor clinical results. Meaningful data regarding the role of arthroscopic revision RCR are sparse thus far. PURPOSE/HYPOTHESIS: To investigate results after arthroscopic revision RCR. We hypothesized that (1) arthroscopic revision RCR would lead to improved outcomes, (2) the clinical results would be dependent on tendon integrity and (3) tear pattern, tendon involvement, and repair technique would influence clinical and structural results. STUDY DESIGN: Case series; Level of evidence 4. METHODS: During a 40-month period, 100 patients who underwent arthroscopic revision RCR were prospectively enrolled in this multicenter study. Outcomes were evaluated preoperatively, at 6 months (6M), and at 24 months (24M) using the Constant score (CS), the Oxford Shoulder Score (OSS), and the Subjective Shoulder Value (SSV). Tendon integrity at 2 years was analyzed using magnetic resonance imaging. A total of 13 patients (13%) were lost to follow-up, and 14 patients (14%) had a symptomatic retear before the 24M follow-up. RESULTS: All clinical scores improved significantly during the study period (CS: preoperative, 44 ± 16; 6M, 58 ± 22; 24M, 69 ± 19 points; OSS: preoperative, 27 ± 8; 6M, 36 ± 11; 24M, 40 ± 9 points; SSV: preoperative, 43% ± 18%; 6M, 66% ± 24%; 24M, 75% ± 22%) (P < .01). At 2 years, a retear rate of 51.8% (43/83) and a surgical revision rate of 12.6% (11/87) were observed. Mean full-thickness tear size decreased from 5.00 ± 1.61 cm2 to 3.25 ± 1.92 cm2 (P = .041). Although the Sugaya score improved from 4.5 ± 0.9 to 3.7 ± 1.4 (P = .043), tendon integrity did not correlate with better outcome scores. Previous open RCR, involvement of the subscapularis, chondral lesions of Outerbridge grade ≥2, and medial cuff failure were correlated with poorer SSV scores at 2 years (P≤ .047). Patients with traumatic retears had better CS and OSS scores at 2 years (P≤ .039). CONCLUSION: Although arthroscopic revision RCR improved shoulder function, retears were frequent but usually smaller. Patients with retears, however, did not necessarily have poorer shoulder function. Patient satisfaction at 2 years was lower when primary open RCR was performed, when a subscapularis tear or osteoarthritis was present, and when the rotator cuff retear was located at the musculotendinous junction. Patients with traumatic retears showed better functional improvement after revision.


Assuntos
Lacerações , Lesões do Manguito Rotador , Artroscopia/métodos , Humanos , Lacerações/cirurgia , Imageamento por Ressonância Magnética , Estudos Prospectivos , Amplitude de Movimento Articular , Estudos Retrospectivos , Manguito Rotador/cirurgia , Lesões do Manguito Rotador/cirurgia , Ruptura/cirurgia , Resultado do Tratamento
4.
Clin Imaging ; 74: 149-155, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33607595

RESUMO

RATIONALE AND OBJECTIVES: To evaluate the imaging capabilities of the REACT pulse sequence in pelvic venous vessels compared to conventional non-contrast pulse sequences. MATERIALS AND METHODS: In addition to routine MRI venography, non-contrast enhanced REACT pulse sequence was performed in 4 healthy volunteers and 21 patients with suspected or known deep venous thrombosis and post thrombotic syndrome. Acquired images were independently interpreted by two MRI radiologists. The sequence performance was subjectively evaluated on a four-point scale regarding the delineation of small peripheral, midsize and large proximal venous vessels, the imaging of vascular pathologies, and the degradation due to artifacts. To evaluate statistical differences in diagnostic accuracy Friedman's test with Dunn's correction was used. RESULTS: REACT depicted the peripheral veins superior to bTFE and T2-TSE with an average score of 3.39 compared to 2.33 in bTFE and 1.77 in T2-TSE. In midsize vessels REACT performed significantly better than T2-TSE (1.94) and bTFE (2.68) with a score of 3.64. For the large proximal vessels REACT (3.39), bTFE (3.33) and T2-TSE (3.56) performed equally without statistical difference. Visibility of venous pathologies was found to be equal between REACT (3.62), bTFE (3.51) and T2-TSE (3.52). The image degradation due to artifacts was rated best in T2-TSE (3.56), followed by REACT (3.39) and bTFE (3.33). CONCLUSIONS: REACT is a promising tool for the visualization of the pelvic venous system using magnetic resonance imaging.


Assuntos
Artefatos , Imageamento por Ressonância Magnética , Abdome , Humanos , Pelve/diagnóstico por imagem , Flebografia
5.
Eur Radiol ; 29(1): 383-391, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29948090

RESUMO

OBJECTIVES: Most existing models that are in use to model hepatic function through assessment of hepatic gadoxetic acid enhancement kinetics do not consider quantitative measures of gadoxetic excretion. We developed a model that allows a simultaneous quantitation of uptake and excretion of liver specific contrast agents. The aim was to improve the assessment of hepatic synthetic function, and provide quantitative measures of hepatic excretion function. METHODS: Sixteen patients underwent dynamic T1-weighted turbo gradient echo imaging at 1.5 T prior and after bolus injection of gadoxetic acid at 0.1 ml/kg. DCE-images were obtained for 30 min after injection. A dual-inlet two-compartment model was then used to fit the measured liver signal values. Four tissue parameters (extracellular volume fraction, arterial flow fraction, uptake rate and excretion half-time) were extracted for each liver segment. RESULTS: The proposed model provided a good fit to acquired data. Mean values for arterial flow fraction (0.08+-0.04), extracellular volume (0.20±0.08) and uptake rate (4.02 ±1.32 /100 ml/min) were comparable to those obtained with the conventional model (0.08±0.05, 0.21±0.12, and 4.93±1.74), but exhibited significantly less variation and improved fit quality. CONCLUSIONS: The proposed model is more accurate than existing conventional models and provides an additional excretion parameter. KEY POINTS: • Models of hepatic contrast agent uptake can be extended to include excretion. • Including an additional excretion parameter improves accuracy of the model. • Standard diagnostic sequences can be extended to incorporate the model.


Assuntos
Líquidos Corporais/metabolismo , Gadolínio DTPA/farmacocinética , Neoplasias Hepáticas/diagnóstico , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Meios de Contraste/farmacocinética , Feminino , Humanos , Fígado/metabolismo , Fígado/fisiopatologia , Testes de Função Hepática , Neoplasias Hepáticas/metabolismo , Neoplasias Hepáticas/fisiopatologia , Masculino , Pessoa de Meia-Idade
6.
Radiology ; 288(3): 764-773, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29786487

RESUMO

Purpose To determine the relationship between diffusion-weighted (DW) liver MR images obtained 4-6 weeks after lobar yttrium 90 (90Y) treatment and overall survival in comparison with PET/CT or established oncologic factors known to affect survival. Materials and Methods The institutional review board approved this prospective intraindividual comparative study in 36 consecutive patients (25 women) with liver-dominant metastases (20 colorectal, 14 breast, two other) (mean age, 60 years ± 10 [standard deviation]) who underwent fluorine 18 (18F) fluorodeoxyglucose (FDG) PET/CT and DW MRI before and 4-6 weeks after 90Y radioembolization. DW MRI response was defined as a mean minimal apparent diffusion coefficient increase of more than 30%; PET/CT response was defined as a mean maximal standardized uptake value decrease of more than 30%. Kaplan-Meier curves, log-rank test, and multivariable Cox regression analyses were used to compare patient survival as a function of imaging and Response Evaluation Criteria in Solid Tumors (RECIST) response, pretreatment Eastern Cooperative Oncology Group (ECOG) performance status (PS) (0 vs 1), hepatic tumor load (<25% vs ≥25%), and presence versus absence of extrahepatic disease. Results Thirty-five of the 36 patients were observed until death (median survival, 36 weeks). Response was observed with PET/CT in 18 of 36 patients (50%). Median survival was 39 weeks in patients who responded to PET/CT versus 27 weeks in those who did not (P = .60). Response was observed with DW MRI in 24 of 36 patients (67%). Median survival was 53 weeks in DW MRI responders versus 20 weeks in nonresponders (P = .01). At multivariable analysis, DW MRI response was the only independent predictor of survival (P < .01). Response based on RECIST parameters, ECOG PS, hepatic tumor load, and presence of extrahepatic metastases did not correlate with survival. Conclusion In patients with hepatic metastases undergoing 90Y radioembolization, prediction of response to therapy with DW MRI was superior to that with PET/CT and established oncologic factors.


Assuntos
Braquiterapia/métodos , Imagem de Difusão por Ressonância Magnética/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/radioterapia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Radioisótopos de Ítrio , Feminino , Humanos , Fígado/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Análise de Sobrevida
7.
J Biomed Mater Res B Appl Biomater ; 106(2): 827-833, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-28387996

RESUMO

PURPOSE: In vivo, a loss of mesh porosity triggers scar tissue formation and restricts functionality. The purpose of this study was to evaluate the properties and configuration changes as mesh deformation and mesh shrinkage of a soft mesh implant compared with a conventional stiff mesh implant in vitro and in a porcine model. MATERIAL AND METHODS: Tensile tests and digital image correlation were used to determine the textile porosity for both mesh types in vitro. A group of three pigs each were treated with magnetic resonance imaging (MRI) visible conventional stiff polyvinylidene fluoride meshes (PVDF) or with soft thermoplastic polyurethane meshes (TPU) (FEG Textiltechnik mbH, Aachen, Germany), respectively. MRI was performed with a pneumoperitoneum at a pressure of 0 and 15 mmHg, which resulted in bulging of the abdomen. The mesh-induced signal voids were semiautomatically segmented and the mesh areas were determined. With the deformations assessed in both mesh types at both pressure conditions, the porosity change of the meshes after 8 weeks of ingrowth was calculated as an indicator of preserved elastic properties. The explanted specimens were examined histologically for the maturity of the scar (collagen I/III ratio). RESULTS: In TPU, the in vitro porosity increased constantly, in PVDF, a loss of porosity was observed under mild stresses. In vivo, the mean mesh areas of TPU were 206.8 cm2 (± 5.7 cm2 ) at 0 mmHg pneumoperitoneum and 274.6 cm2 (± 5.2 cm2 ) at 15 mmHg; for PVDF the mean areas were 205.5 cm2 (± 8.8 cm2 ) and 221.5 cm2 (± 11.8 cm2 ), respectively. The pneumoperitoneum-induced pressure increase resulted in a calculated porosity increase of 8.4% for TPU and of 1.2% for PVDF. The mean collagen I/III ratio was 8.7 (± 0.5) for TPU and 4.7 (± 0.7) for PVDF. CONCLUSION: The elastic properties of TPU mesh implants result in improved tissue integration compared to conventional PVDF meshes, and they adapt more efficiently to the abdominal wall. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 827-833, 2018.


Assuntos
Implantes Experimentais , Pneumoperitônio/cirurgia , Poliuretanos , Telas Cirúrgicas , Animais , Feminino , Pneumoperitônio/metabolismo , Pneumoperitônio/patologia , Porosidade , Suínos , Resistência à Tração
8.
Radiology ; 285(3): 1023-1031, 2017 12.
Artigo em Inglês | MEDLINE | ID: mdl-28799842

RESUMO

Purpose To investigate the efficacy and safety of irreversible electroporation (IRE) in the treatment of hepatic tumors not suitable for thermal ablation (radiofrequency ablation [RFA] or microwave ablation). Materials and Methods This was an institutional review board-approved prospective study in 29 patients (15 men, 14 women; mean age, 63 years ± 12 [standard deviation]) with 43 primary (n = 8) or secondary (n = 35) malignant liver tumors who underwent computed tomography (CT)-guided IRE. All target tumors were located immediately adjacent to major hepatic veins, portal veins, or both; thus, they were not considered suitable for RFA or microwave ablation. Patients underwent postinterventional CT and magnetic resonance (MR) imaging. Systematic follow-up MR imaging was performed for 24 months on average to assess complete ablation, intrahepatic tumor recurrence, and complications. The 95% confidence intervals (CIs) were determined for the rate of bile duct strictures, incomplete ablation, and tumor recurrence. Results Complete ablation was achieved in 40 (93%; 95% CI: 85, 100) of 43 target tumors, with a safety margin of 5-10 mm, and was confirmed at immediate postinterventional CT and MR imaging. In 13 (33%; 95% CI: 18, 47) of 40 completely ablated tumors, intrahepatic tumor recurrence was observed at 2-18 months. However, only two (15%; 95% CI: 0, 35) of these 13 tumors were observed within the ablation zone. In the remaining 11 (85%; 95% CI: 65, 100), tumor growth was observed alongside the needle tract. None of the two true local recurrences occurred at the site of the vessel. All adjacent vessels remained perfused at follow-up. Five (24%; 95% CI: 5, 39) of 21 patients with target tumors adjacent to portal veins developed mild to moderate cholestasis 2-6 weeks after IRE. Conclusion IRE is useful to avoid incomplete ablation secondary to heat-sink effects and damage to major blood vessels; however, needle tract seeding is observed in 26% of treated tumors, and IRE induces sufficient local heating to bile ducts in 24% of ablations. © RSNA, 2017.


Assuntos
Técnicas de Ablação/efeitos adversos , Técnicas de Ablação/métodos , Eletroporação/métodos , Veias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/terapia , Veia Porta/diagnóstico por imagem , Doenças Vasculares/etiologia , Feminino , Seguimentos , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento , Doenças Vasculares/diagnóstico por imagem , Doenças Vasculares/prevenção & controle
9.
PLoS One ; 11(9): e0163630, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27648953

RESUMO

[This corrects the article DOI: 10.1371/journal.pone.0155717.].

10.
PLoS One ; 11(5): e0155717, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27192201

RESUMO

OBJECT: In MRI, implants and devices can be delineated via susceptibility artefacts. To discriminate susceptibility voids from proton-free structures, different positive contrast techniques were implemented. The purpose of this study was to evaluate a pulse sequence-based positive contrast technique (PCSI) and a post-processing susceptibility gradient mapping algorithm (SGM) for visualization of iron loaded mesh implants in patients. MATERIAL AND METHODS: Five patients with iron-loaded MR-visible inguinal hernia mesh implants were examined at 1.5 Tesla. A gradient echo sequence (GRE; parameters: TR: 8.3ms; TE: 4.3ms; NSA:2; FA:20°; FOV:350mm²) and a PCSI sequence (parameters: TR: 25ms; TE: 4.6ms; NSA:4; FA:20°; FOV:350mm²) with on-resonant proton suppression were performed. SGM maps were calculated using two algorithms. Image quality and mesh delineation were independently evaluated by three radiologists. RESULTS: On GRE, the iron-loaded meshes generated distinct susceptibility-induced signal voids. PCSI exhibited susceptibility differences including the meshes as hyperintense signals. SGM exhibited susceptibility differences with positive contrast. Visually, the different algorithms presented no significant differences. Overall, the diagnostic value was rated best in GRE whereas PCSI and SGM were barely "sufficient". CONCLUSION: Both "positive contrast" techniques depicted implanted meshes with hyperintense signal. SGM comes without additional acquisition time and can therefore be utilized in every patient.

11.
Invest Radiol ; 50(6): 409-15, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25763526

RESUMO

OBJECTIVES: Patients with hepatic metastases who are candidates for Y90-radioembolization (Y90-RE) usually have advanced tumor stages with involvement of both liver lobes. Per current guidelines, these patients have usually undergone several cycles of potentially hepatotoxic systemic chemotherapy before Y90-RE is at all considered, requiring split (lobar) treatment sessions to reduce hepatic toxicity. Assessing response to Y90-RE early, that is, already after the first lobar session, would be helpful to avoid an ineffective and potentially hepatotoxic second lobar treatment. We investigated the accuracy with which diffusion- weighted magnetic resonance imaging (DWI-MRI) and positron emission tomography/computed tomography (PET/CT) can provide this information. METHODS: An institutional review board-approved prospective intraindividual comparison trial on 35 patients who underwent fluorodeoxyglucose PET/CT and DWI-MRI within 6 weeks before and 6 weeks after Y90-RE to treat secondary-progressive liver metastases from solid cancers (20 colorectal, 13 breast, 2 other) was performed. An increase of minimal apparent diffusion coefficient (ADCmin) or decrease of maximum standard uptake value (SUVmax) by at least 30% was regarded as positive response. Long-term clinical and imaging follow-up was used to distinguish true- from false-response classifications. RESULTS: On the basis of long-term follow-up, 23 (66%) of 35 patients responded to the Y90 treatment. No significant changes of metastases size or contrast enhancement were observable on pretreatment versus posttreatment CT or magnetic resonance images.However, overall SUVmax decreased from 8.0 ± 3.9 to 5.5 ± 2.2 (P < 0.0001), and ADCmin increased from 0.53 ± 0.13 × 10(-3) mm2/s to 0.77 ± 0.26 × 10(-3) mm2/s (P < 0.0001). Pretherapeutic versus posttherapeutic changes of ADCmin and SUVmax correlated moderately (r = -0.53). In 4 of the 35 patients (11%), metastases were fluorodeoxyglucose-negative such that no response assessment was possible by PET. In 25 (71%) of the 35 patients, response classification by PET and DWI-MRI was concordant; in 6 (17%) of the 35, it was discordant. In 5 of the 6 patients with discordant classifications, follow-up confirmed diagnoses made by DWI. The positive predictive value to predict response was 22 (96%) of 23 for MRI and 15 (88%) of 17 for PET. The negative predictive value to predict absence was 11 (92%) of 12 for MRI and 10 (56%) of 18 for PET. Sensitivity for detecting response was significantly higher for MRI (96%; 22/23) than for PET (65%; 15/23) (P < 0.02). CONCLUSIONS: Diffusion-weighted magnetic resonance imaging appears superior to PET/CT for early response assessment in patients with hepatic metastases of common solid tumors. It may be used in between lobar treatment sessions to guide further management of patients who undergo Y90-RE for hepatic metastases.


Assuntos
Braquiterapia/métodos , Imagem de Difusão por Ressonância Magnética , Neoplasias Hepáticas/radioterapia , Tomografia por Emissão de Pósitrons , Tomografia Computadorizada por Raios X , Radioisótopos de Ítrio/uso terapêutico , Feminino , Seguimentos , Humanos , Fígado/diagnóstico por imagem , Fígado/patologia , Neoplasias Hepáticas/secundário , Masculino , Pessoa de Meia-Idade , Imagem Multimodal , Estudos Prospectivos , Reprodutibilidade dos Testes , Resultado do Tratamento
12.
Invest Radiol ; 50(7): 436-42, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25756683

RESUMO

OBJECTIVES: From a surgeon's point of view, meshes implanted for inguinal hernia repair should overlap the defect by 3 cm or more during implantation to avoid hernia recurrence secondary to mesh shrinkage. The use of magnetic resonance imaging (MRI)-visible meshes now offers the opportunity to noninvasively monitor whether a hernia is still covered sufficiently in the living patient. The purpose of this study was therefore to evaluate the efficacy of hernia repair after mesh implantation based on MRI findings (mesh coverage, visibility of hernia structures) and based on the patient's postoperative symptoms. MATERIALS AND METHODS: In this prospective study approved by the ethics committee, 13 MRI-visible meshes were implanted in 10 patients (3 bilaterally) for inguinal hernia repair between March 2012 and January 2013. Senior visceral surgeons (>7 years of experience) implanted the meshes via laparoscopic transabdominal preperitoneal procedure. Magnetic resonance imaging was performed within 1 week and at 3 months after surgery at a 1.5-T system. Mesh position, deformation, and coverage of the hernia were visually assessed in consensus and rated on a 4-point semiquantitative scoring system. Distances of hernia center point to the mesh borders (overlap) were measured. Mesh position and hernia coverage postoperatively and at 3 months after implantation were correlated with the respective patients' clinical symptoms. Statistical analysis was performed using the Wilcoxon signed rank test. RESULTS: Two of the 13 meshes presented with an atypical mesh configuration along the course of psoas muscle with a short medial overlap of less than 2 cm. Eleven of the 13 meshes exhibited a typical mesh configuration with lateral folding and initial overlap of more than 2 cm. Between baseline and 3 months' follow-up, average overlap decreased in the medial direction by -10% (3.75 cm vs 3.36 cm, P = 0.22), in the lateral direction by -20% (3.55 cm vs 2.82 cm, P = 0.01), in the superior direction by -2% (5.82 cm vs 5.72 cm, P = 0.55), and in the posterior direction by -19% (4.11 cm vs 3.34 cm, P = 0.01). Between baseline and 3 months' follow-up, mesh folding increased mildly in the medial direction, whereas no change was found in the other directions. Individual folds of the mesh were flexible over time, whereas the gross visual configuration and location of meshes did not change. Four of the 13 former hernia sites were mildly painful at follow-up, whereas 9 of the 13 were completely asymptomatic. No correlation between clinical symptoms and mesh position or hernia coverage was found. CONCLUSIONS: Our results suggest that the actual postoperative mesh position after release of laparoscopic pneumoperitoneum may deviate from its position during surgery. Gross mesh position and configuration differed between patients but did not change within a given patient over the observation period of 3 months after surgery. We did not find a correlation between clinical symptoms and mesh configuration or position. Shrinkage of meshes does occur, yet not as concentric process, but regionally variable, leading to a reduced hernia coverage of up to -20% in the lateral and posterior directions.


Assuntos
Hérnia Inguinal/patologia , Hérnia Inguinal/cirurgia , Herniorrafia/métodos , Imageamento por Ressonância Magnética/métodos , Cirurgia Assistida por Computador/métodos , Telas Cirúrgicas , Adulto , Idoso , Feminino , Herniorrafia/instrumentação , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Estatística como Assunto , Resultado do Tratamento
13.
Eur Arch Otorhinolaryngol ; 271(12): 3325-31, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25022718

RESUMO

The objective of the present study was to evaluate the cochlear aqueduct (CA) in Meniere's disease (MD) and to disclose radiological differences of CA between MD and non-MD patients by means of high-resolution computed tomography (HRCT) and high-resolution magnetic resonance imaging (HRMRI). Radiological data of 86 ears of MD patients which were separated into 52 ears of diseased side group (MD-D group) and 34 ears of contralateral non-affected side group of unilateral MD (MD-ND group), 27 ears of patients with sensorineural hearing loss (SNHL group) and 56 ears of patients with somatoform dizziness and normal hearing (control group) were analyzed retrospectively. The bony type of CA, the bony length of CA, and the bony width of CA medial orifice was measured in HRCT. The visibility of CA in HRMRI was scored. Fluid length in CA and fluid width in medial orifice were measured in HRMRI. Data were compared between MD-D, MD-ND, SNHL, and control group. There were no significant differences in the bony type of CA, bony length of CA, bony width of CA medial orifice, and fluid width of CA medial orifice between MD-D, MD-ND, SNHL and control group (p > 0.05). However, CA fluid length of MD-D (5.13 ± 1.88 mm) and of MD-ND group (5.44 ± 1.81 mm) was significantly shorter than fluid length of SNHL (6.90 ± 1.55 mm) (p < 0.001, p = 0.001) and of control group (7.43 ± 1.24 mm) (p < 0.001, p < 0.001). The ratio between CA fluid length and CA bony length was the smallest in MD-D group (0.403; p = 0.009). CA bony dimensions of affected ears of MD are normal, but CA fluid length is decreased.


Assuntos
Aqueduto da Cóclea/diagnóstico por imagem , Aqueduto da Cóclea/patologia , Aumento da Imagem , Imageamento por Ressonância Magnética/métodos , Doença de Meniere/diagnóstico , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Adulto Jovem
14.
Invest Radiol ; 49(7): 439-44, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24651663

RESUMO

OBJECTIVES: Shrinkage and deformation of mesh implants used for hernia treatment can be the cause of long-term complications. The purpose of this study was to quantify noninvasively time-dependent mesh shrinkage, migration, and configuration changes in patients who were surgically treated for inguinal hernia using magnetic resonance imaging (MRI)-visible mesh implants. MATERIALS AND METHODS: In an agarose phantom, meshes in different shrinkage and folding conditions were used to validate the quantification process. Seven patients who were surgically (3 bilaterally) treated for inguinal hernia using iron-loaded mesh implants were prospectively examined using MRI. Gradient echo sequences in sagittal and transverse orientations were performed on day 1 after surgery and at day 90. The mesh-induced signal voids were semiautomatically segmented and a polygonal surface model was generated. A comparison of area and centroid position was performed between the 2 calculated surfaces (day 1 vs day 90). RESULTS: The phantom study revealed a maximum deviation of 3.6% between the MRI-based quantification and the actual mesh size. All 10 implants were successfully reconstructed. The mean (SD) observed mesh shrinkage 90 days after surgery was 20.9% (7.1%). The mean (SD) centroid movement was 1.17 (0.47) cm. Topographic analysis revealed mean (SD) local configuration changes of 0.23 (0.03) cm. CONCLUSIONS: In this study, significant mesh shrinkage (20.9%) but marginal changes in local mesh configuration occurred within 90 days after mesh implantation. Centroid shift of the mesh implant can be traced back to different patient positioning and abdominal distension. The developed algorithm facilitates noninvasive assessment of key figures regarding MRI-visible meshes. Consequently, it might help to improve mesh technology as well as surgical skills.


Assuntos
Algoritmos , Análise de Falha de Equipamento/métodos , Hérnia/patologia , Herniorrafia/instrumentação , Imageamento por Ressonância Magnética/métodos , Telas Cirúrgicas , Adulto , Idoso , Hérnia/terapia , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Técnica de Subtração , Fatores de Tempo , Resultado do Tratamento
15.
J Biomed Mater Res B Appl Biomater ; 102(6): 1165-9, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24470265

RESUMO

BACKGROUND: Application of a mesh in presence of pneumoperitoneum may cause deformation or wave formation when gas is released. Moreover, mesh shrinkage during subsequent wound healing cannot be detected in vivo without invasive diagnostics. Using MRI-visible polyvinylidene fluoride (PVDF) mesh, the extend of mesh deformation and shrinkage could be objectified by MRI for the first time. MATERIALS AND METHODS: Laparoscopic intraperitoneal onlay mesh (IPOM) implantation was performed in 10 female rabbits using ferro-oxide loaded PVDF meshes. MRI measurements were performed postoperatively at days 1 and 90. After three-dimensional reconstruction of all MRI images the total surface and the effective surface of the implanted mesh were explored and calculated computer-assisted. RESULTS: In all cases, the mesh could be identified in MRI. The subsequent three-dimensional reconstruction always allowed a calculation of the mesh area. In relation to the original size of the used textile implant, we found neither a significant reduction of the effective mesh surface after release of the pneumoperitoneum at day 1 after laparoscopic surgery nor a significant change of the total surface of this large pore mesh by the end of the observation period. CONCLUSIONS: In vivo investigation of mesh surface via MRI could exclude a significant initial reduction of the effective mesh surface after release of pneumoperitoneum, in this IPOM rabbit model. A further subsequent shrinkage of these large pore PVDF meshes could be excluded, as well. Imaging of MRI-visible IPOM mesh turned out to be a sufficient tool to objectify mesh configuration and position in vivo.


Assuntos
Imageamento por Ressonância Magnética , Pneumoperitônio/diagnóstico por imagem , Pneumoperitônio/cirurgia , Polivinil , Telas Cirúrgicas , Animais , Modelos Animais de Doenças , Feminino , Teste de Materiais , Coelhos , Radiografia
16.
J Am Soc Echocardiogr ; 27(3): 249-57, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24368027

RESUMO

BACKGROUND: Myocardial deformation analysis by speckle-tracking echocardiography (STE) has been shown to accurately predict viability in patients with chronic ischemic left ventricular (LV) dysfunction. The aim of this study was to evaluate two-dimensional STE for the prediction of global and segmental LV functional changes after acute myocardial infarction (AMI) in comparison with late gadolinium enhancement (LGE) cardiac magnetic resonance (CMR). METHODS: In 93 patients (mean age, 60 ± 11 years) with first AMIs (55 with ST-segment elevation myocardial infarctions and 38 with non-ST-segment elevation myocardial infarctions) treated with acute percutaneous coronary intervention, global peak longitudinal strain was determined to describe global function by STE, and peak systolic circumferential and longitudinal strain was determined for segmental function analysis. LGE CMR was performed to define the amounts of global and segmental myocardial scar. STE and LGE CMR were performed within 48 hours of AMI. At 6-month follow-up, transthoracic echocardiography was repeated to determine global und segmental LV recovery and adverse LV remodeling (increase in end-systolic volume > 15%). RESULTS: Accuracy to predict global functional improvement as well as LV remodeling at 6-month follow-up after AMI was similar for STE and LGE CMR (areas under the curve, 0.715 vs 0.729 [P = .8830] and 0.806 vs 0.824 [P = .7141], respectively). Peak systolic circumferential strain < -14.2% had sensitivity of 71.6% and specificity of 58.1% to predict segmental functional improvement. Compared with LGE CMR, the predictive accuracy of transmural STE for segmental functional improvement at 6-month follow-up was lower (area under the curve, 0.788 vs 0.668; P = .0001). Predictive accuracy for segmental functional improvement could be improved by analysis of endocardial circumferential strain (area under the curve, 0.700 vs 0.668 for transmural speckle-tracking echocardiographic analysis; P = .0023). CONCLUSIONS: Two-dimensional STE allows the prediction of global functional recovery as well as LV remodeling after AMI with accuracy comparable with that of LGE CMR. Accuracy to predict segmental functional recovery using transmural deformation analysis by two-dimensional STE is inferior compared with LGE CMR but can be improved by a layer-specific analysis of endocardial deformation.


Assuntos
Ecocardiografia/métodos , Técnicas de Imagem por Elasticidade/métodos , Gadolínio DTPA , Ventrículos do Coração/fisiopatologia , Imagem Cinética por Ressonância Magnética/métodos , Infarto do Miocárdio/fisiopatologia , Disfunção Ventricular Esquerda/fisiopatologia , Meios de Contraste/administração & dosagem , Módulo de Elasticidade , Feminino , Gadolínio DTPA/administração & dosagem , Dureza , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/complicações , Infarto do Miocárdio/diagnóstico , Prognóstico , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Disfunção Ventricular Esquerda/diagnóstico , Disfunção Ventricular Esquerda/etiologia
17.
Invest Radiol ; 48(11): 770-8, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23732864

RESUMO

OBJECTIVES: Until today, there have been no conventional imaging methods available to visualize surgical mesh implants and related complications. In a new approach, we incorporated iron particles into polymer-based implants and visualized them by magnetic resonance imaging (MRI).After clinical approval of such implants, the purposes of this study were to evaluate the MRI conspicuity of such iron-loaded mesh implants in patients treated for inguinal hernias and to assess the immediate postsurgical mesh configuration. MATERIALS AND METHODS: Approved by the ethics committee, in this prospective cohort study, 13 patients (3 patients with bilateral hernia treatment) were surgically treated for inguinal hernia receiving iron-loaded mesh implants between March and October 2012. The implants were applied via laparoscopic technique (transabdominal preperitoneal technique; n = 8, 3 patients with bilateral hernia treatment) or via open surgical procedure (Lichtenstein surgery; n = 5). Magnetic resonance imaging was performed 1 day after the surgery at a 1.5-T scanner (Achieva; Philips, Best, The Netherlands) with a 16-channel receiver coil using 3 different gradient echo sequences (first gradient echo sequence, second gradient echo sequence, and third gradient echo sequence [GRE1-3]) and 1 T2-weighted turbo spin-echo sequence (T2wTSE). Three radiologists independently evaluated mesh conspicuity and diagnostic value with respect to different structures using a semiquantitative scoring system (1, insufficient; 2, sufficient; 3, good; 4, optimal). Mesh deformation and coverage of the hernia were visually assessed and rated using a 5-point semiquantitative scoring system. Statistical analysis was performed using mixed models and linear contrast. RESULTS: All 16 implants were successfully visualized by MRI. On gradient echo sequences, the mesh is clearly delineated as a thick hypointense line. On T2wTSE, the mesh was depicted as a faint hypointense line, which was difficult to identify. The first gradient echo sequence was rated best for visual conspicuity (mean [SD], 3.8 [0.4]). T2-weighted turbo spin-echo sequence was preferred for evaluation of the surrounding anatomy (mean [SD], 3.7 [0.3]). For the combined assessment of both mesh and anatomy, GRE3 was rated best (mean [SD], 2.9 [0.7]). Local air slightly reduced mesh delineation (lowest mean [SD] rating, 2.9 [0.7] for GRE3). Overall, in both implantation techniques, the meshes exhibited mild to moderate deformations (mean [SD], 3.3 [0.4], 3.1 [0.3], and 2.8 [0.3] on average with open technique, 2.7 [0.3], 2.7 [0.2], and 2.3 [0.3] with laparoscopic technique). Coverage of the hernia was achieved in 15 of the 16 implants. CONCLUSIONS: Combining iron-loaded implants and MRI, we achieved mesh visualization for the first time in patients. For MRI protocol, we propose a combination of different gradient echo sequences and T2-weighted turbo spin-echo sequences: first gradient echo sequence for mesh configuration, T2wTSE for anatomy assessment, and GRE3 for evaluation of hernia coverage and mesh localization. Using our approach, MRI could become a noninvasive alternative to open surgical exploration if mesh-related complications were suspected.


Assuntos
Hérnia Inguinal/cirurgia , Imageamento por Ressonância Magnética/métodos , Complicações Pós-Operatórias/diagnóstico , Telas Cirúrgicas , Adulto , Idoso , Feminino , Humanos , Ferro , Laparoscopia , Masculino , Pessoa de Meia-Idade , Polímeros , Estudos Prospectivos , Resultado do Tratamento
18.
Invest Radiol ; 48(4): 200-5, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23344516

RESUMO

PURPOSE: Polymer-based textile meshes for abdominal hernia treatment are invisible by conventional imaging methods, including magnetic resonance imaging (MRI). Integration of iron particles in the mesh base material allows MRI visualization of meshes. Positive-contrast susceptibility imaging (PCSI) was implemented to separate susceptibility-induced voids from proton-deficient voids. The purpose of this study was to compare PCSI with conventional gradient echo and turbo spin echo (TSE) sequences for the in vivo assessment of superparamagnetic iron oxide particle-loaded surgical meshes in an animal model. METHODS AND MATERIALS: Iron-loaded polymer meshes were implanted into the abdominal wall of 10 rabbits. At days 1, 30, and 90 after surgery, conventional gradient echo, TSE, and PCSI were performed at 1.5 T in the sagittal and axial planes. Images were scored by 2 radiologists with respect to mesh visibility, delineation of the surrounding tissue, differentiation from other structures, and overall diagnostic use, on a 4-point scale ranging from 1 (insufficient) to 4 (excellent). The results were compared using Wilcoxon signed-rank tests. The mesh shape, possible deformation or fracture, and possible mesh migration were evaluated on the different pulse sequences and compared with the results at surgery and autopsy. RESULTS: The iron-loaded meshes appeared as hypointense signal voids on gradient echo sequences, as a hyperintense line on PCSI, and as a very thin dark line on TSE images. In all animals, a precise depiction of the mesh location and its spatial configuration and integrity was possible by MRI and confirmed by surgical and autopsy results. In all 4 categories and at all 3 time points of imaging, image quality scores were significantly higher for gradient echo imaging (range, 3.60-3.80) compared with PCSI (range, 3.12-3.42) and TSE (range, 1.64-1.89). At day 90, the image quality ratings of gradient echo and PCSI were comparable. In 2 cases, the complete delineation of mesh borders was impossible because of signal voids of adjacent anatomical structures, whereas PCSI helped achieve this differentiation. CONCLUSION: In this rabbit model of iron-loaded implanted abdominal meshes, standard gradient echo imaging was best suitable to assess implant location, integrity, and configuration. In 2 of 10 animals, PCSI helped achieve a complete delineation of mesh borders.


Assuntos
Hérnia Abdominal/cirurgia , Imageamento por Ressonância Magnética/métodos , Telas Cirúrgicas , Animais , Dextranos , Imageamento Tridimensional , Estudos Longitudinais , Nanopartículas de Magnetita , Polímeros , Coelhos , Estatísticas não Paramétricas
19.
Eur Heart J Cardiovasc Imaging ; 14(6): 570-8, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23148082

RESUMO

AIMS: Separate analysis of endocardial and epicardial myocardial layer deformation has become possible using strain-encoded cardiovascular magnetic resonance (SENC) and 2D-dimensional speckle tracking echocardiography (Echo). This study evaluated and compared both modalities for the assessment of infarct transmurality as defined by late gadolinium enhancement (LGE) cardiovascular magnetic resonance (CMR). METHODS AND RESULTS: In 29 patients (age 62.4 ± 11.7 years, 23 male) with ischaemic cardiomyopathy, SENC using 1.5 T CMR and Echo were performed. Peak circumferential systolic strain of the endocardial and the epicardial layer of 304 myocardial segments was assessed by SENC and by Echo. The segmental transmurality of myocardial infarction was determined as relative amount of LGE (0%: no infarction; 1-50%: non-transmural infarction; 51-100%: transmural infarction). Endocardial and epicardial strain defined by SENC and by Echo differed significantly between segments of different infarct transmurality determined by CMR. Endocardial layer circumferential strain analysis by Echo and by SENC allowed distinction of segments with non-transmural infarction from non-infarcted segments with similar accuracy [area under the curve (AUC) 0.699 vs. 0.649, respectively, P = 0.239]. Epicardial layer circumferential strain analysis by Echo and by SENC allowed distinction of transmural from non-transmural myocardial infarction defined by LGE CMR with similar accuracy (AUC 0.721 vs. 0.664, respectively, P = 0.401). Endocardial strain by SENC correlated moderately with endocardial strain by Echo (r = 0.50; standard error of estimate = 5.2%). CONCLUSION: Layer-specific analysis of myocardial deformation by Echo and by SENC allows discrimination between different transmurality categories of myocardial infarction with similar accuracy. However, accuracy of both methods is non-optimal, indicating that further tools for improvement should be evaluated in the future.


Assuntos
Ecocardiografia/métodos , Interpretação de Imagem Assistida por Computador , Imagem Cinética por Ressonância Magnética/métodos , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/patologia , Idoso , Análise de Variância , Estudos de Coortes , Ecocardiografia Doppler em Cores/métodos , Endocárdio/diagnóstico por imagem , Endocárdio/patologia , Feminino , Gadolínio , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/diagnóstico por imagem , Isquemia Miocárdica/patologia , Variações Dependentes do Observador , Pericárdio/diagnóstico por imagem , Pericárdio/patologia , Curva ROC , Sensibilidade e Especificidade , Índice de Gravidade de Doença
20.
Surg Endosc ; 26(5): 1468-75, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22179447

RESUMO

BACKGROUND: Prosthetic mesh implants are widely used in hernia surgery. To show long-term mesh-related complications such as shrinkage or adhesions, a precise visualization of meshes and their vicinity in vivo is important. By supplementing mesh fibers with ferro particles, magnetic resonance imaging (MRI) can help to delineate the mesh itself. This study aimed to demonstrate and quantify time-dependent mesh shrinkage in vivo by MRI. METHODS: Polyvinylidenfluoride (PVDF) meshes with incorporated superparamagnetic iron oxides (SPIOs) were implanted as an abdominal wall replacement in 30 rats. On days 1, 7, 14, or 21, MRI was performed using a gradient echo sequence with repetition time (TR)/echo time (TE) of 50/4.6 and a flip angle of 20°. The length, width, and area of the device were measured on axial, coronal, and sagittal images, and geometric deformations were assessed by surgical explantation. RESULTS: In all cases, the meshes were visualized and their area estimated by measuring the length and width of the mesh. The MRI presented a mean area shrinkage in vivo of 13% on day 7, 23% on day 14, and 23% on day 21. Postmortem measurements differed statistically from MRI, with a mean area shrinkage of 23% on day 7, 28% on day 14, and 30% on day 21. Ex vivo measurements of shrinkage showed in vivo measurements to be overestimated approximately 8%. Delineation of the mesh helped to show folding or adhesions close to the intestine. CONCLUSION: Loading of surgical meshes with SPIOs allows their precise visualization during MRI and guarantees an accurate in vivo assessment of their shrinkage. The authors' observation clearly indicates that shrinkage in vivo is remarkably less than that shown by illustrated explantation measurements. The use of MRI with such meshes could be a reliable technique for checking on proper operation of implanted meshes and showing related complications, obviating the need for exploratory open surgical revision.


Assuntos
Compostos de Ferro , Telas Cirúrgicas/normas , Animais , Desenho de Equipamento , Hérnia Abdominal/cirurgia , Imageamento por Ressonância Magnética , Masculino , Polivinil/uso terapêutico , Próteses e Implantes , Ratos , Ratos Sprague-Dawley
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...