Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 48
Filtrar
1.
Rev Sci Instrum ; 92(3): 033540, 2021 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-33820069

RESUMO

An Electron Cyclotron Emission Imaging (ECEI) data analysis module has been developed for the OMFIT platform to accommodate the needs of users at the DIII-D tokamak for physics applications. The user can easily access the ECEI spatial observation windows in the plasma that are calculated based on the automatically retrieved hardware setup and available DIII-D equilibria, perform spectral analysis, and obtain 2D electron temperature fluctuation images. The module provides a powerful data post-processing package for extracting important physics parameters from the 2D measurements, including the radial structure and poloidal mode number of Alfven eigenmodes, as well as the frequency-vs-wavenumber dispersion relationship of broadband MHD. The module propagates characterized synthetic fluctuations for the user, so one can perform forward modeling tasks with simple analytical fluctuations.

2.
Rev Sci Instrum ; 92(3): 033524, 2021 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-33820017

RESUMO

Final design studies in preparation for manufacturing have been performed for functional components of the vacuum portion of the ITER Low-Field Side Reflectometer (LFSR). These components consist of an antenna array, electron cyclotron heating (ECH) protection mirrors, phase calibration mirrors, and vacuum windows. Evaluation of these components was conducted at the LFSR test facility and DIII-D. The antenna array consists of six corrugated-waveguide antennas for simultaneous profile, fluctuation, and Doppler measurements. A diffraction grating, incorporated into the plasma-facing miter bend, provides protection of sensitive components from stray ECH at 170 GHz. For in situ phase calibration of the LFSR profile reflectometer, an embossed mirror is incorporated into the adjacent miter bend. Measurements of the radiated beam profile indicate that these components have a small, acceptable effect on mode conversion and beam quality. Baseline transmission characteristics of the dual-disk vacuum window are obtained and are used to guide ongoing developments. Preliminary simulations indicate that a surface-relief structure on the window surfaces can greatly improve transmission. The workability of real-time phase measurements was demonstrated on the DIII-D profile reflectometer. The new automated real-time analysis agrees well with the standard post-processing routine.

3.
Clin Oral Investig ; 25(3): 1069-1076, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32583240

RESUMO

OBJECTIVES: The purpose of this study was to quantify the symmetry of the alveolar process of the maxilla and palate during the first year of life in healthy infants with the help of a semiautomatic segmentation technique. MATERIALS AND METHODS: Maxillary plaster models of seventy healthy babies at 0, 3, 6, 9, and 12 months were collected and digitized. A semiautomatic segmentation tool was used to extract the alveolus and palate. The resulting model was aligned within a reference frame and mirrored on its medial plane. Distance maps were created and analyzed to compare and quantify the differences between the two hemispheres. Additional hemispherical width and area measurements were performed. An ANOVA test with additional post hoc tests was performed to check if the symmetry changed during development. Finally, the results were tested on intra- and interobserver variability. RESULTS: The absolute mean inter-surface distance between the original and mirrored models in each age group ranged between 0.23 and 0.30 mm. Width and area analysis showed a small but significant larger left palatal hemisphere. ANOVA and post hoc tests showed no significant difference in symmetry between groups. Reliability analysis showed no significant differences between observers. CONCLUSIONS: This study showed that in this infant population, only a small degree of palatal asymmetry was present, which can be considered as normal and clinically irrelevant. CLINICAL RELEVANCE: The data from this study can be used in future comparative studies as reference data. Furthermore, modeling of these data can help in predicting the growth pattern, which may lead to improved treatment protocols for children with craniofacial anomalies.


Assuntos
Fissura Palatina , Arco Dental , Criança , Humanos , Lactente , Maxila , Reprodutibilidade dos Testes
4.
Ned Tijdschr Tandheelkd ; 127(12): 665-670, 2020 Dec.
Artigo em Holandês | MEDLINE | ID: mdl-33367292

RESUMO

By means of an online questionnaire, the opinions of dental health practitioners on 'orthodontics' were assessed on the basis of 10 statements. There were 523 responses, 51% of which were from general practitioners, a relatively large number from orthodontists (31%) and 18% from other dental health practitioners. Concerning indication of treatment, dental health prior to treatment and the value of straightened teeth, opinions were clearly positive, somewhat more among orthodontist than among general practitioners. Patients knowledge concerning orthodontics and the negative side of orthodontics and their trust in the durability of orthodontic retention are all considered to be more positively present in patients by orthodontists than general practitioners. 1 in 3 non-orthodontists considered carrying out orthodontic procedures in the general practice to be fine. More than 90% of orthodontists disagreed. Female dental practitioners more often consider orthodontic treatment to belong with an orthodontist. The number of women was equally divided across the different groups.


Assuntos
Ortodontia , Odontólogos , Feminino , Humanos , Ortodontistas , Papel Profissional , Inquéritos e Questionários
5.
Ned Tijdschr Tandheelkd ; 127(12): 671-676, 2020 Dec.
Artigo em Holandês | MEDLINE | ID: mdl-33367293

RESUMO

In this article, the short- and long-term results of two types of functional appliances are discussed regarding their ability to stimulate the mandibular growth at mandibular retrognathia and reduce an increased overjet. Removable functional appliances, or activators, are compared to a fixed functional appliance, the Herbst appliance. The activator, often consisting of an acrylic base, is advised to be worn for 12 to 20 hours a day. The Herbst appliance consists of interconnected bands around the molar- and premolar bands, keeping the mandibula continuously positioned forward by means of hinges or telescopes. In the short-term, both appliances are effective in reducing the overjet, improving the molar-occlusion and reducing the mandibular retrognathia. The comparative literature is inconclusive as to which appliance is more effective on which level, skeletal or dentoalveolar. The removable appliances are more likely to be accepted at a younger age, whilst the fixed appliances are more suitable for the adolescents. The stability of the long-term treatment effects is minimally described in the existing literature. However, the highest stability rate seems to apply to the Herbst appliance. The impact of a widely applied second phase of treatment with fixed appliances, with possible use of intermaxillary class II elastics and retention using functional appliances is barely taken into account.


Assuntos
Má Oclusão Classe II de Angle , Aparelhos Ortodônticos Funcionais , Adolescente , Dente Pré-Molar , Cefalometria , Humanos , Mandíbula
6.
AJNR Am J Neuroradiol ; 41(4): 566-572, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32079598

RESUMO

The cerebral ventricles have been studied since the fourth century BC and were originally thought to harbor the soul and higher executive functions. During the infancy of neuroradiology, alterations to the ventricular shape and position on pneumoencephalography and ventriculography were signs of mass effect or volume loss. However, in the current era of high-resolution cross-sectional imaging, variation in ventricular anatomy is more easily detectable and its clinical significance is still being investigated. Interpreting radiologists must be aware of anatomic variations of the ventricular system to prevent mistaking normal variants for pathology. We will review of the anatomy and development of the lateral ventricles and discuss several ventricular variations.


Assuntos
Ventrículos Laterais/anatomia & histologia , Humanos
7.
Ned Tijdschr Tandheelkd ; 126(4): 183-189, 2019 Apr.
Artigo em Holandês | MEDLINE | ID: mdl-30994114

RESUMO

An 11-year-old girl presented at an orthodontist asking for the correction of the crooked position of her upper and lower front teeth. In addition, the patient was concerned about the abnormal shape and size of tooth 21. There was a disto-occlusion, crowding and tooth gemination of tooth 21 with the shape of a dens invaginatus. The tooth, moreover, was infected. Teeth 21 and 14 were extracted as part of the treatment. By means of a guided transposition, tooth 23 was brought to the extraction site of tooth 21. Treatment was performed with hybrid fixed appliance techniques.


Assuntos
Incisivo , Má Oclusão , Dente Pré-Molar , Criança , Feminino , Humanos , Má Oclusão/terapia
8.
Clin Oral Investig ; 23(10): 3705-3712, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30635787

RESUMO

OBJECTIVES: The aim of this study was to develop an accurate and intuitive semi-automatic segmentation technique to calculate an average maxillary arch and palatal growth profile for healthy newborns in their first year of life. MATERIALS AND METHODS: Seventy babies born between 1985 and 1988 were included in this study. Each child had five impressions made in the first year after birth that were digitalized. A semi-automatic segmentation tool was developed and used to assess the maxillary dimensions. Finally, random effect models were built to describe the growth and build a simulation population of 10,000 newborns. The segmentation was tested for inter- and intra-observer variability. RESULTS: The Pearson correlation coefficient for each of the variables was between 0.94 and 1.00, indicating high inter-observer agreement. The paired sample t test showed that, except for the tuberosity distance, there were small, but significant differences in the landmark placements between observers. Intra-observer repeatability was high, with Pearson correlation coefficients ranging from 0.87 to 1.00 for all measurements, and the mean differences were not significant. A third or second degree growth curve could be successfully made for each parameter. CONCLUSIONS: These findings indicated this method could be used for objective clinical evaluation of maxillary growth. CLINICAL RELEVANCE: The resulting growth models can be used for growth studies in healthy newborns and for growth and treatment outcome studies in children with cleft lip and palate or other craniofacial anomalies.


Assuntos
Maxila/crescimento & desenvolvimento , Fenda Labial , Fissura Palatina , Arco Dental/crescimento & desenvolvimento , Humanos , Lactente , Recém-Nascido , Variações Dependentes do Observador , Palato/crescimento & desenvolvimento
9.
Phys Rev Lett ; 121(23): 235001, 2018 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-30576208

RESUMO

Prior to eruptive events such as edge localized modes (ELMs), quasicoherent fluctuations, referred to as pedestal modes, are observed in the edge of fusion devices. We report on the investigations of nonlinear coupling between these modes during quasistationary inter-ELM phases leading to the ELM onset. Three dominant modes, with density and magnetic signatures, are identified as key players in the triggering mechanism of certain classes of ELMs. We demonstrate that one of these modes is amplified by the two others through three wave interactions. The amplified mode is radially shifted relative to the other two modes towards the last-closed flux surface as the ELM event approaches. Our results suggest that nonlinear coupling of pedestal modes, associated with radial distortions pushing out of the pedestal, is a possible mechanism for the triggering of low frequency ELMs relevant for future fusion devices.

10.
Rev Sci Instrum ; 87(11): 11D303, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910444

RESUMO

A Synthetic Diagnostics Platform (SDP) for fusion plasmas has been developed which provides state of the art synthetic reflectometry, beam emission spectroscopy, and Electron Cyclotron Emission (ECE) diagnostics. Interfaces to the plasma simulation codes GTC, XGC-1, GTS, and M3D-C1 are provided, enabling detailed validation of these codes. In this paper, we give an overview of SDP's capabilities, and introduce the synthetic diagnostic modules. A recently developed synthetic ECE Imaging module which self-consistently includes refraction, diffraction, emission, and absorption effects is discussed in detail. Its capabilities are demonstrated on two model plasmas. The importance of synthetic diagnostics in validation is shown by applying the SDP to M3D-C1 output and comparing it with measurements from an edge harmonic oscillation mode on DIII-D.

11.
Phys Rev Lett ; 116(9): 095001, 2016 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-26991180

RESUMO

Experiments in the DIII-D tokamak show that fast-ion transport suddenly becomes stiff above a critical threshold in the presence of many overlapping small-amplitude Alfvén eigenmodes (AEs). The threshold is phase-space dependent and occurs when particle orbits become stochastic due to resonances with AEs. Above threshold, equilibrium fast-ion density profiles are unchanged despite increased drive, and intermittent fast-ion losses are observed. Fast-ion Dα spectroscopy indicates radially localized transport of the copassing population at radii that correspond to the location of midcore AEs. The observation of stiff fast-ion transport suggests that reduced models can be used to effectively predict alpha profiles, beam ion profiles, and losses to aid in the design of optimized scenarios for future burning plasma devices.

12.
J Craniofac Surg ; 26(4): 1242-5, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26080166

RESUMO

OBJECTIVE: To compare the Asher-McDade aesthetic index with 2 systems used to score the appearance of the nasolabial area in patients with a complete cleft lip and palate. DESIGN: Retrospective analysis of the results of complete unilateral cleft lip and palate patients. SETTING: Academic Center for Dentistry of Amsterdam and the VU University Medical Center. PATIENTS: Six-year-olds with complete unilateral cleft lip and palate. MAIN OUTCOME MEASURES: Cleft lip and palate patients assessed using the scoring system proposed by Prahl et al, a 5-point ordinal scale, and the scoring system proposed by Asher-McDade et al by 6 judges, 3 orthodontists, and 3 plastic surgeons. A calculation of intra- and interobserver reliability was made. A comparison was made of all the assessment methods using Kendalls' tau. RESULTS: Photographs of 55 children (38 boys and 17 girls) with complete unilateral cleft lip and palate were assessed. For the scoring system of Prahl et al, interobserver reliability varied from 0.43 to 0.53, for the 5-point scale between 0.45 and 0.57, and for the scoring system by Asher-McDade et al these varied between 0.52 and 0.66. Multiple significant correlations were found between the used scoring systems. CONCLUSION: It can be concluded that the Asher-McDade aesthetic index is still superior to the other scoring systems used in this study. However, all 3 scoring systems can reliably be used when 3 or more observers are used.


Assuntos
Fenda Labial/cirurgia , Fissura Palatina/cirurgia , Estética/psicologia , Avaliação de Resultados em Cuidados de Saúde/ética , Procedimentos de Cirurgia Plástica/psicologia , Criança , Fenda Labial/psicologia , Fissura Palatina/psicologia , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Estudos Retrospectivos
13.
Rev Sci Instrum ; 85(11): 11D702, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25430212

RESUMO

The two-dimensional mm-wave imaging reflectometer (MIR) on DIII-D is a multi-faceted device for diagnosing electron density fluctuations in fusion plasmas. Its multi-channel, multi-frequency capabilities and high sensitivity permit visualization and quantitative diagnosis of density perturbations, including correlation length, wavenumber, mode propagation velocity, and dispersion. The two-dimensional capabilities of MIR are made possible with 12 vertically separated sightlines and four-frequency operation (corresponding to four radial channels). The 48-channel DIII-D MIR system has a tunable source that can be stepped in 500 µs increments over a range of 56 to 74 GHz. An innovative optical design keeps both on-axis and off-axis channels focused at the cutoff surface, permitting imaging over an extended poloidal region. The integrity of the MIR optical design is confirmed by comparing Gaussian beam calculations to laboratory measurements of the transmitter beam pattern and receiver antenna patterns. Measurements are presented during the density ramp of a plasma discharge to demonstrate unfocused and focused MIR signals.

14.
Rev Sci Instrum ; 85(11): 11D802, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25430215

RESUMO

The implementation of advanced electron cyclotron emission imaging (ECEI) systems on tokamak experiments has revolutionized the diagnosis of magnetohydrodynamic (MHD) activities and improved our understanding of instabilities, which lead to disruptions. It is therefore desirable to have an ECEI system on the ITER tokamak. However, the large size of optical components in presently used ECEI systems have, up to now, precluded the implementation of an ECEI system on ITER. This paper describes a new optical ECEI concept that employs a single spherical mirror as the only optical component and exploits the astigmatism of such a mirror to produce an image with one-dimensional spatial resolution on the detector. Since this alternative approach would only require a thin slit as the viewing port to the plasma, it would make the implementation of an ECEI system on ITER feasible. The results obtained from proof-of-principle experiments with a 125 GHz microwave system are presented.

15.
Rev Sci Instrum ; 85(11): 11E701, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25430364

RESUMO

By arranging the particle first banana orbits to pass near a distant detector, the light ion beam probe (LIBP) utilizes orbital deflection to probe internal fields and field fluctuations. The LIBP technique takes advantage of (1) the in situ, known source of fast ions created by beam-injected neutral particles that naturally ionize near the plasma edge and (2) various commonly available diagnostics as its detector. These born trapped particles can traverse the plasma core on their inner banana leg before returning to the plasma edge. Orbital displacements (the forces on fast ions) caused by internal instabilities or edge perturbing fields appear as modulated signal at an edge detector. Adjustments in the q-profile and plasma shape that determine the first orbit, as well as the relative position of the source and detector, enable studies under a wide variety of plasma conditions. This diagnostic technique can be used to probe the impact on fast ions of various instabilities, e.g., Alfvén eigenmodes (AEs) and neoclassical tearing modes, and of externally imposed 3D fields, e.g., magnetic perturbations. To date, displacements by AEs and by externally applied resonant magnetic perturbation fields have been measured using a fast ion loss detector. Comparisons with simulations are shown. In addition, nonlinear interactions between fast ions and independent AE waves are revealed by this technique.

16.
J Craniofac Surg ; 25(4): 1222-5, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24978682

RESUMO

OBJECTIVE: The aim of this study was to determine the reliability of 2 scoring systems. DESIGN: This study used a retrospective analysis of the results of complete unilateral cleft lip and palate patients. SETTING: The study was conducted at the VU Medical Center and the Academic Center for Dentistry of Amsterdam. PATIENTS: Patients were complete unilateral cleft lip and palate patients at the age of 6 years. MAIN OUTCOME MEASURES: Assessment of the nose and lip together and separately with a numerical photographic reference scoring system and with a 5-point ordinal scale without the use of a reference photograph by 6 judges. Intraobserver and interobserver reliability was calculated; both ways of assessment were compared by using Kendall tau. RESULTS: Photographs were available of 55 children (6 years old, 38 boys and 17 girls) with a complete unilateral cleft lip and palate. The interobserver reliabilities of the lip and nose together were 0.53 and, for the nose and lip separately, 0.51 and 0.43, respectively with the use of the numerical scale. In the 5-point scale, these were 0.55 for the nose and lip together and 0.57 and 0.45 for the nose and lip separately, respectively. Furthermore, it was found that the lip dominates in the scorings of the lip and nose together (linear regression analysis). CONCLUSIONS: The 2 tested systems are equivalent in their reliability and outcome. The lip is dominating in the overall scorings. It is advocated to use the 5-point scale without the use of a reference photograph and to assess the lip and nose separately.


Assuntos
Fenda Labial/cirurgia , Fissura Palatina/cirurgia , Avaliação de Resultados em Cuidados de Saúde/métodos , Criança , Fenda Labial/patologia , Fissura Palatina/patologia , Estética , Feminino , Humanos , Masculino , Variações Dependentes do Observador , Fotografação/normas , Análise de Regressão , Reprodutibilidade dos Testes , Estudos Retrospectivos
17.
Phys Rev Lett ; 110(26): 265008, 2013 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-23848889

RESUMO

The application of static magnetic field perturbations to a tokamak plasma is observed to alter the dynamics of high-frequency bursting Alfvén modes that are driven unstable by energetic ions. In response to perturbations with an amplitude of δB/B∼0.01 at the plasma boundary, the mode amplitude is reduced, the bursting frequency is increased, and the frequency chirp is smaller. For modes of weaker bursting character, the magnetic perturbation induces a temporary transition to a saturated continuous mode. Calculations of the perturbed distribution function indicate that the 3D perturbation affects the orbits of fast ions that resonate with the bursting modes. The experimental evidence represents an important demonstration of the possibility of controlling fast-ion instabilities through "phase-space engineering" of the fast-ion distribution function, by means of externally applied perturbation fields.

18.
Phys Rev Lett ; 110(6): 065004, 2013 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-23432263

RESUMO

We report the first observation of prompt neutral beam-ion losses due to nonresonant scattering induced by toroidal and reversed shear Alfvén eigenmodes in the DIII-D tokamak. The coherent losses are of full energy beam ions expelled from the plasma on their first poloidal orbit. The first-orbit loss mechanism causes enhanced, concentrated losses on the first wall exceeding nominal levels of prompt losses. The loss amplitude scales linearly with the mode amplitude. The data provide a novel and direct measure of the radial excursion or scatter of particles induced by individual modes and may shed light on the mechanism for the scattering of energetic particles in interstellar medium.

19.
Rev Sci Instrum ; 83(10): 10E325, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23126983

RESUMO

Backscattering experiments to detect lower-hybrid (LH) waves have been performed in Alcator C-Mod, using the two modified channels (60 GHz and 75 GHz) of an ordinary-mode reflectometry system with newly developed spectral recorders that can continuously monitor spectral power at a target frequency. The change in the baseline of the spectral recorder during the LH wave injection is highly correlated to the strength of the X-mode non-thermal electron cyclotron emission. In high density plasmas where an anomalous drop in the lower hybrid current drive efficiency is observed, the observed backscattered signals are expected to be generated near the last closed flux surface, demonstrating the presence of LH waves within the plasma. This experimental technique can be useful in identifying spatially localized LH electric fields in the periphery of high-density plasmas.

20.
Phys Rev Lett ; 109(4): 045001, 2012 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-23006093

RESUMO

A significant fraction of high-harmonic fast-wave (HHFW) power applied to NSTX can be lost to the scrape-off layer (SOL) and deposited in bright and hot spirals on the divertor rather than in the core plasma. We show that the HHFW power flows to these spirals along magnetic field lines passing through the SOL in front of the antenna, implying that the HHFW power couples across the entire width of the SOL rather than mostly at the antenna face. This result will help guide future efforts to understand and minimize these edge losses in order to maximize fast-wave heating and current drive.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...