Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 79
Filtrar
1.
J Cardiovasc Surg (Torino) ; 54(5): 605-15, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24002390

RESUMO

AIM: We reported our 10-year experience with the Gore TAG thoracic endoprosthesis for treatment of thoracic aorta pathologies. METHODS: We performed a systematic retrospective study of prospectively recorded data of all patients who underwent thoracic endovascular aortic repair (TEVAR) procedure with Gore TAG thoracic endoprosthesis between January 2001 and March 2013, and conducted an analysis of patient demographics, periprocedural records, complications, reinterventions, and survival. RESULTS: During this period, 96 patients underwent TEVAR with Gore TAG device. Indications for operation were degenerative aneurysm in 38 patients (39.6%), type B aortic dissection in 24 (25.0%), penetrating ulcer in 8 (8.3%), intramural hematoma in 10 (10.4%), traumatic transection in 9 (9.4%), and other pathology in 7 (7.3%). Forty-four patients (45.8%) had acute thoracic aortic syndromes requiring immediate or delayed procedures. Forty-two (43.8%) patients underwent supra-aortic trunks debranching. Landing zones were zone 0 in 8 patients (8.3%), zone 1 in 4 (4.2%), zone 2 in 36 (37.5%), zone 3 in 29 (30.2%) and zone 4 in 19 (19.8%). Technical success rate was 96.6%. Thirty-day mortality was 10.4%. Major adverse events included stroke in 8.3%, spinal cord ischemia in 4.2%, and vascular injuries in 7.3%. Overall survival in the cohort was 86% at 1 year and 78% at 2 years with a mean follow-up of 11.1±12.4 months. Major reintervention was required in 10 patients (10.4%). CONCLUSION: This single-center study demonstrates acceptable rates for operative mortality and major adverse events after endovascular repair of various thoracic aortic pathologies with both generations of Gore TAG device. However, a better knowledge in long-term results is necessary to define target populations.


Assuntos
Aorta Torácica/cirurgia , Doenças da Aorta/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Stents , Idoso , Idoso de 80 Anos ou mais , Aorta Torácica/diagnóstico por imagem , Doenças da Aorta/diagnóstico por imagem , Doenças da Aorta/mortalidade , Aortografia/métodos , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/cirurgia , Desenho de Prótese , Sistema de Registros , Reoperação , Estudos Retrospectivos , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento
2.
Eur J Vasc Endovasc Surg ; 44(6): 562-7; discussion 568, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23040530

RESUMO

OBJECTIVES: We wanted to compare autonomy recovery after open and endovascular infrainguinal surgery for critical limb ischaemia (CLI) in octogenarians. MATERIALS AND METHODS: We performed a retrospective analysis of 167 consecutive CLI octogenarians who underwent infrainguinal open surgery (OS) or endovascular surgery (ES) between 2003 and 2008. OS and ES groups were compared in terms of autonomy level (Parker score), survival, limb salvage and patency rates. RESULTS: Preoperative autonomy level was similar in both groups (OS n = 109, ES n = 58) but 6-month postoperative autonomy level was better after ES (p = 0.01). There was a trend towards better survival after OS (74% at 1 year, 62% at 2 years, 32% at 4 years with OS and 68%, 50%, 17% respectively for ES p = 0.06), but no difference regarding limb salvage (91% at 1 year, 90% at 2 years, 89% at 4 years for OS and 94%, 87%, 86% respectively for ES, p = 0.939) and primary patency (76% at 1 year, 59% at 2 years, 50% at 4 years for OS and 82%, 75%, 32% respectively for ES, p = 0.467). CONCLUSIONS: ES is justified in CLI octogenarians, because it allows restoring a higher autonomy level, with limb salvage and patency rates comparable to OS.


Assuntos
Endarterectomia , Procedimentos Endovasculares , Isquemia/cirurgia , Extremidade Inferior/irrigação sanguínea , Autonomia Pessoal , Enxerto Vascular , Atividades Cotidianas , Fatores Etários , Idoso de 80 Anos ou mais , Amputação Cirúrgica , Distribuição de Qui-Quadrado , Estado Terminal , Endarterectomia/efeitos adversos , Endarterectomia/mortalidade , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Humanos , Isquemia/mortalidade , Isquemia/fisiopatologia , Estimativa de Kaplan-Meier , Salvamento de Membro , Seleção de Pacientes , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/cirurgia , Recuperação de Função Fisiológica , Reoperação , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Enxerto Vascular/efeitos adversos , Enxerto Vascular/mortalidade , Grau de Desobstrução Vascular
3.
J Mal Vasc ; 36(3): 169-73, 2011 Jun.
Artigo em Francês | MEDLINE | ID: mdl-21482057

RESUMO

Endovascular treatment and stent implantation in the superficial femoral artery have been proposed for over 20 years. However, the first experiments with stainless stents were relatively disappointing. The first improvement consisted in the introduction of nitinol self-expanding stents. This technology allowed an initial improvement of clinical performances, but the first generation of nitinol stents demonstrated a relatively high rate of fractures. Better knowledge of the femoral artery biomechanics and advances in technology allowed to propose a second generation of nitinol stents with improved flexibility, which decreased the rates of fracture. In-stent restenosis related to neointimal hyperplasia has also led to the development of new concepts to improve patency rates after stenting of the femoral artery: drug-eluting stents (coated-stents), biodegradable stents, and covered stents. These technologies will help to treat more complex lesions of the femoral artery in the future, with comparable results to those obtained with femoropopliteal bypasses, but we are still waiting for results of ongoing studies.


Assuntos
Arteriopatias Oclusivas/cirurgia , Artéria Femoral , Stents , Stents Farmacológicos , Humanos , Procedimentos Cirúrgicos Vasculares/instrumentação , Procedimentos Cirúrgicos Vasculares/métodos , Procedimentos Cirúrgicos Vasculares/tendências
4.
Acta Chir Belg ; 109(6): 684-93, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-20184050

RESUMO

Currently, critical limb ischemia occurs in an ageing population with more and more diabetic patients and infra-popliteal lesions. In order to be as little invasive as possible, endovascular techniques have been proposed as one of the best options for these patients. In the following review, we present the specificities and assess the clinical effectiveness of endovascular treatment for infra-popliteal lesions in critical limb ischemia. We undertook a literature review based on publications dealing with critical limb ischemia and infra-popliteal endovascular treatment and published during the last decade. All relevant studies were systematically reviewed. The recorded outcomes were: immediate technical success, peri-operative complications, 30-day mortality, primary and secondary patency, limb salvage, and patient survival. Thirty-one studies including a total of 3164 patients (range: 13 to 993) were included in this review. Technical success rates ranged between 72% and 100%. Peri-operative complications rates ranged between 0% and 16%, most complications being considered as minor. 30-day mortality rates ranged between 0% and 5%. Primary, secondary patency and limb salvage rates were respectively about 60%, 65%, and 85%. One-year survival was about 80%. In conclusion, endovascular treatment can be considered as a good option for the treatment of infra-popliteal lesions in critical limb ischemia. Despite the non entirely satisfactory patency rates, endovascular treatment may provide wound healing and limb salvage.


Assuntos
Angioplastia com Balão , Isquemia/terapia , Perna (Membro)/irrigação sanguínea , Crioterapia , Humanos , Artéria Poplítea/patologia , Stents , Grau de Desobstrução Vascular , Cicatrização
5.
J Mal Vasc ; 33(4-5): 196-201, 2008 Dec.
Artigo em Francês | MEDLINE | ID: mdl-19019600

RESUMO

The aim of the study was to evaluate the efficacy of vacuum-assisted closure (VAC) in vascular patients presenting limb ulcers or non healed amputations. The efficacy of the VAC was studied in terms of healing, walking distance, and autonomy of life. This retrospective study included 14 patients, 11 men and three women, who were treated by a VAC therapy between December 2003 and February 2007. Two patients presented critical ischemia with limb ulcers and 12 patients non healed amputations despite previous revascularisation. Vascular reconstruction was performed in all cases before the VAC therapy. The rate of wound healing with VAC therapy was 87%. After wound healing, 92% of patients were walking and 62% of them were independent. In conclusion, VAC therapy may be a useful tool to accelerate healing of lower-limb wounds or non healing wounds secondary to amputation, allowing a faster recovery with a good level of autonomy.


Assuntos
Tratamento de Ferimentos com Pressão Negativa/métodos , Procedimentos Cirúrgicos Vasculares/métodos , Amputação Cirúrgica/efeitos adversos , Desenho de Equipamento , Úlcera do Pé/cirurgia , Humanos , Tratamento de Ferimentos com Pressão Negativa/instrumentação , Complicações Pós-Operatórias/classificação , Complicações Pós-Operatórias/terapia , Procedimentos Cirúrgicos Vasculares/efeitos adversos , Procedimentos Cirúrgicos Vasculares/instrumentação , Cicatrização , Ferimentos e Lesões/classificação , Ferimentos e Lesões/terapia
6.
J Cardiovasc Surg (Torino) ; 49(5): 639-51, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-18670382

RESUMO

AIM: The aim of this study was to analyze the Literature covering the characteristics of secondary ruptured abdominal aortic aneurysm (AAA) following endovascular repair with aortic stent graft (ASG). METHODS: The study based on a Pubmed search of articles describing the characteristics of secondary ruptured AAA after ASG between January 1995 and May 2008. A total of 105 articles were selected, including the following characteristics: aneurysm diameter evolution, delay between implantation and rupture, average follow-up time, mechanisms implicated, results following further repair. RESULTS: Out of a total of 23 002 ASG cases reported, of which 47.4% (10 911) were carried out by ASG suppliers themselves, 227 ruptures (1%) have been described. After exclusion of the perioperatory ruptures (occurring within the first month), the average duration of implantation at rupture was 27+/-16 months, with an average follow-up of 22.4+/-14 months. When the evolution of the sac was mentioned, AAA diameter decreased or remained stable before rupture in 55.7% of the cases. Mechanisms of rupture have been reported in 168 cases and consisted in a failure of the ASG in 76.1% of the cases. When patients were operated, the mortality rate was 39%. CONCLUSION: This study showed how little is actually known about rupture of stented AAA. The available data were provided by studies sponsored by companies in 47.4% of the cases, and had usually too short follow-up considering the average of duration of implantation at rupture. Rupture mechanisms were not reported in all cases, but a failure of the ASG was considered as responsible for the rupture in a majority of the cases. The absence of warning signs of rupture emphasizes the need of caution about the durability of ASG and also the need to undertake further studies with longer follow-ups.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Ruptura Aórtica/cirurgia , Aneurisma da Aorta Abdominal/mortalidade , Ruptura Aórtica/mortalidade , Implante de Prótese Vascular/métodos , Humanos , Fatores de Risco
7.
J Periodontal Res ; 43(2): 224-31, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18326058

RESUMO

BACKGROUND AND OBJECTIVE: Previous studies have reported different periodontal bacteria in atherosclerotic lesions, but their involvement in plaque formation remains unclear. The aim of the present study was to investigate the presence of 20 periodontal bacteria in atherosclerotic samples and healthy blood vessels (used as controls) and to clarify their relationship in regard to clinical and bacteriological periodontal status. MATERIAL AND METHODS: The day before vascular surgery the patients had a thorough periodontal examination and bacteriological samples were taken from periodontally diseased sites. Atheromatous plaques, internal mammary arteries and saphenous veins were harvested during surgery. A DNA-DNA hybridization procedure was used to screen periodontal and vascular samples for the 20 selected bacterial species. RESULTS: Periodontal samples from the severe periodontitis group were found to have a higher prevalence and biomass of bacterial species than the moderate periodontitis group. In vessel samples, the prevalence of the same 20 bacterial species analyzed together was similar in the two groups, except for saphenous veins. CONCLUSION: The presence of periodontal pathogens in atherosclerotic plaques and in apparently healthy vessels appeared to reflect a higher level of bacteremia rather than infection of endothelial cells.


Assuntos
Aterosclerose/microbiologia , Artéria Torácica Interna/microbiologia , Bolsa Periodontal/microbiologia , Veia Safena/microbiologia , Idoso , Campylobacter rectus , DNA Bacteriano/análise , Eikenella corrodens , Feminino , Fusobacterium nucleatum , Humanos , Masculino , Pessoa de Meia-Idade , Hibridização de Ácido Nucleico , Reação em Cadeia da Polimerase , Porphyromonas gingivalis
8.
J Mal Vasc ; 32(4-5): 192-200, 2007 Dec.
Artigo em Francês | MEDLINE | ID: mdl-17630242

RESUMO

AIM OF THE STUDY: Retrospective evaluation of the immediate and mid term mortality and morbidity of carotid surgical revascularisations in a population of octogenarians with severe carotid artery stenosis. MATERIAL AND METHOD: Retrospective study of all patients 80 years old and more, consecutively operated for an internal carotid artery stenosis, from January 1991 to December 2003, in the Unit of Vascular Surgery of the Civil Hospices of Strasbourg. We analyzed the perioperative death and stroke rates at 30 days and the mid term survival. RESULTS: We performed 81 carotid revascularisations on 70 patients. The mean age of the population studied was 83.5 (+/-2.8 years), (range 80-92). Twenty-four stenoses (29.6%) were symptomatic (23 transient ischemic accidents, 1 stroke), and 57 stenoses (70.4%) were asymptomatic. The mean degree of stenosis was 89.2+/-8.1% (based on NASCET evaluation). The main cardiovascular risk factor was arterial hypertension (95.7%). The overall perioperative death and stroke rate was 7.1%: 2 deaths, one of them related to a stroke, and 3 strokes (confidence interval: 2.4-15.9%). The perioperative death and stroke rate in the symptomatic stenosis group was 0%, and 8.8% in the asymptomatic stenosis group (p=0.163). No specific risk factor of neurologic events has been found except ASA 3 or higher (RR: 3.84 [1.2-12.1]). The mean follow up was 3.6 years (range 2-11.3), no patient was lost to follow-up. The Kaplan-Meier 5-year survival was 52%. The mean time to death was 3.5 years after the operation. Only 16.7% of these deaths were stroke-related. CONCLUSIONS: Multicentric prospective studies, which have determined current recommendations for carotid surgery, did not include patients aged 79 years and older. In this particular population, the good results observed in our institution in the symptomatic carotid stenosis group would support the use of surgical treatment. The perioperative death and stroke rate observed for the asymptomatic group, clearly superior to current recommendations, suggests in our experience and especially for ASA> or =3, an individual evaluation to determinate the best indication.


Assuntos
Estenose das Carótidas/cirurgia , Endarterectomia das Carótidas/efeitos adversos , Endarterectomia das Carótidas/mortalidade , Idoso de 80 Anos ou mais , Feminino , Humanos , Ataque Isquêmico Transitório/epidemiologia , Ataque Isquêmico Transitório/cirurgia , Masculino , Morbidade , Complicações Pós-Operatórias , Estudos Retrospectivos , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/mortalidade , Acidente Vascular Cerebral/cirurgia , Taxa de Sobrevida
9.
Ann Chir ; 130(5): 340-5, 2005 Jun.
Artigo em Francês | MEDLINE | ID: mdl-15935792

RESUMO

Many bullfighters had been seriously injured, even sometimes killed during the fight in the bullring (around 300 deaths since the beginning of the 20th century). There is no comparison between bullfight's traumas and civil or war traumas, so only specialized medicine doctors and surgeons can be involved for practising. Surgery of bullfighting is a single speciality. The bullfight's surgeon in safekeeping will operate immediately in the bullfight place's infirmary and will aim at reducing the deep effect of horn injury. In this work, authors point out the bullfight pathology's complexity and its surgical treatment by presenting two original cases.


Assuntos
Lesões do Pescoço/cirurgia , Esportes , Ferimentos Perfurantes/cirurgia , Animais , Bovinos , França , Humanos , Masculino , Espanha
10.
Ann Fr Anesth Reanim ; 24(4): 347-54, 2005 Apr.
Artigo em Francês | MEDLINE | ID: mdl-15826784

RESUMO

OBJECTIVES: Despite the fact that there are no approved indications by the French regulatory agency and despite the absence of recommendations, low molecular weight heparins (LMWH) are frequently used in vascular surgery, an area at both high risk of perioperative arterial and venous thrombosis as well as of bleeding. The aim of this study was to investigate medical practice in vascular surgery, using a survey of prescribers of antithrombotic agents. STUDY DESIGN: Survey of physicians from different specialities involved in patient care before, during, and after vascular surgery. PATIENTS AND METHODS: Between March and June 2003, 301 physicians filled a questionnaire providing information about their antithrombotic regimens depending on the type of vascular surgery. These physicians are involved in an important part of vascular surgery activity in France. RESULTS: The survey confirmed the use of LMWH in near 80% of patients scheduled for vascular surgery. The prescribed LMWH is frequently associated with antiplatelets agents. During patient's hospitalization, LMWH prescription is guided by numerous factors, making the prescription protocol rather complex. Major risk factors favoring continued prophylaxis after patient's hospital discharge include surgery with a high risk of thromboembolic events and limited ambulation. Analysis of the data also showed that the surgeon and the referring physician are both implicated in the majority of the postoperative care following patient's discharge, and therefore, in prescribing the antithrombotic drug. CONCLUSION: This survey gives information on practical use of LMWH in the vascular surgery setting. This information could lead to prospective studies of LMWH in situations other than venous thromboembolic disease.


Assuntos
Anticoagulantes/uso terapêutico , Heparina de Baixo Peso Molecular/uso terapêutico , Trombose/prevenção & controle , Procedimentos Cirúrgicos Vasculares , Anticoagulantes/efeitos adversos , Coleta de Dados , Quimioterapia Combinada , Uso de Medicamentos , França , Heparina de Baixo Peso Molecular/efeitos adversos , Complicações Intraoperatórias/prevenção & controle , Inibidores da Agregação Plaquetária/uso terapêutico , Cuidados Pós-Operatórios , Complicações Pós-Operatórias/prevenção & controle , Fatores de Risco , Inquéritos e Questionários
11.
Ann Chir ; 129(5): 301-9, 2004 Jun.
Artigo em Francês | MEDLINE | ID: mdl-15220107

RESUMO

Performed since the 1950s, vascular grafting has opened modern era of vascular surgery. Autologous venous grafts are of first choice for revascularisation of small arteries. Synthetic grafts are mainly modelled using microporous polytetrafluoroethylene or terephtalate polyethylene. These prosthesis are mainly used for revascularization of medium and large size arteries.


Assuntos
Implante de Prótese Vascular , Prótese Vascular , Prótese Vascular/efeitos adversos , Prótese Vascular/estatística & dados numéricos , Prótese Vascular/tendências , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/métodos , Implante de Prótese Vascular/tendências , Oclusão de Enxerto Vascular/etiologia , Humanos , Seleção de Pacientes , Polietilenotereftalatos , Politetrafluoretileno , Desenho de Prótese , Transplante Autólogo , Transplante Heterólogo , Transplante Homólogo , Grau de Desobstrução Vascular
12.
Eur J Vasc Endovasc Surg ; 27(1): 33-41, 2004 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-14652834

RESUMO

OBJECTIVES: To investigate mechanisms of textile failure in explanted human aortic endoprostheses. MATERIALS AND METHODS: Endoprostheses (n31) underwent optical and scanning electron microscopy, filament dynamometry, and saturation index measurement. RESULTS: The macroscopic lesions observed in the Stentor and Vanguard devices were holes at the extremities of the stents and slipping of the warp yarns at the level of sutures or of the longitudinal seams. The macroscopic lesions observed in AneurX endoprostheses were holes, slipping of the warp yarns and ruptures of the ligatures. The macroscopic lesions observed in the two Talent endoprostheses were sections of fibers at the level of the suture holes and few areas lesions of wear, with sometimes holes at the contact of the stent extremities. Stentor, Vanguard and AneurX all demonstrated low saturation indexes of the fabric (44-59%) with an important anisotropy. Whereas the Talent endograft demonstrated a high index of saturation (124-131%) with a low anisotropy. We did not demonstrate significant polymer degradation in any of the endoprostheses. CONCLUSIONS: It is essential to take into account the saturation index to optimally choose a woven textile for the construction of an endoprosthesis since this property of the textile may contribute to explain the macroscopic lesions observed. We did not observe significant polymer degradation by filament dynamometry but further studies are needed to confirm these data.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Prótese Vascular , Análise de Falha de Equipamento , Humanos , Microscopia Eletrônica de Varredura , Stents
13.
Eur J Vasc Endovasc Surg ; 26(4): 429-36, 2003 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-14512008

RESUMO

OBJECTIVES: Previous explant retrieval studies have shown ruptures occurring on the remeshing line and the guide line of two types of warp-knitted grafts. The aim of our study was to characterize the mechanisms these ruptures. MATERIALS AND METHODS: We performed an in vitro study of the mechanical and chemical characteristics of virgin prostheses. We studied 2 virgin polyester warp-knitted grafts models: the Cooley Double Velour and the Microvel Double Velour constructed by Meadox (USA), using the following techniques: characterization and de-knitting of the textile structure, circumferential tensile strength, filament dynamometry, critical dissolution time of the filaments and scanning electron microscopy. RESULTS: Both prostheses were constructed in the same way but the texturized yarns of the Cooley graft included twice as many filaments (54) than the Microvel (27). There was more adsorbed tension in the Cooley structure than in the Microvel. The circumferential tensile strength test demonstrated that the Cooley graft always ruptured on the remeshing line and the Microvel graft always ruptured at the interface between the remeshing line and the standard line. Filament dynamometry demonstrated a heterogeneous behavior of the filaments inside the yarns, mainly at the remeshing line of the Cooley graft (27.1 cN/tex +/- 11.5% versus 26.1 cN/tex +/- 2.2% for the guide line and 28 cN/tex +/- 6.7% for the standard knit). Critical dissolution time of the filaments was significantly lower for the Microvel grafts (2.5 sec versus 17.2 sec for the Cooley). CONCLUSIONS: Rupture of knitted polyester prostheses are probably an underestimated phenomenon. They may occur at specific areas of the graft. Further studies are required to determine whether all grafts of this type are at risk.


Assuntos
Prótese Vascular , Poliésteres , Falha de Prótese , Têxteis , Análise de Falha de Equipamento , Humanos , Técnicas In Vitro , Microscopia Eletrônica de Varredura , Solubilidade , Estresse Mecânico , Resistência à Tração
15.
J Cardiovasc Surg (Torino) ; 43(5): 665-9, 2002 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-12386581

RESUMO

We report the case of a surgically treated congenital Budd-Chiari syndrome related to agenesia of the retrohepatic inferior vena cava. The first symptoms of the disease were noticed in childhood. The increasing symptomatology led to propose, at the age of 30 years, first a percutaneous transluminal angioplasty which failed, because of the impossibility to recanalize the obstructed segment. Then a surgical procedure consisting of the implantation of ePTFE prosthesis between the right atria and the retrohepatic inferior vena cava was performed. The hepatic biopsy showed a centrolobular fibrosis and an old subglissonian infarction. The patient was improved, allowing him to recover a normal life. However, three years later, an angiographic evaluation performed because of a recurrence of a slight abdominal pain, showed a thrombosis of the bypass. An attempt at thrombolysis failed. Since the patient did not present major clinical and biological consequences we only proposed a surveillance and no endovascular procedure because of the fear of a pulmonary emboli. The purpose of this case report is to review the literature and discuss the etiopathology of congenital Budd-Chiari syndrome with regard to the different therapeutic options.


Assuntos
Implante de Prótese Vascular , Síndrome de Budd-Chiari/cirurgia , Veia Cava Inferior/anormalidades , Adulto , Síndrome de Budd-Chiari/etiologia , Oclusão de Enxerto Vascular , Humanos , Masculino
17.
J Vasc Surg ; 33(5): 1015-21, 2001 May.
Artigo em Inglês | MEDLINE | ID: mdl-11331843

RESUMO

AIM: The purpose of the study was the characterization of a type of rupture occurring on warp-knitted polyester vascular prostheses. MATERIALS AND METHODS: We studied 20 cases of warp-knitted polyester vascular prostheses that were explanted from humans that showed a longitudinal rupture as a part of a collaborative retrieval program. All the prostheses were immediately fixed in a 10% formaldehyde solution after their explantation in the operating room. The clinical data of these cases were recorded. The explants were photographed, washed to eliminate the surrounding tissues, and photographed again. The ruptures were characterized with macroscopic examination, optical stereomicroscopy, and scanning electron microscopy. RESULTS: The mean duration of implantation of the prostheses was 16.0 +/- 3.3 years (range, 9-20.7 years). The prostheses were Cooley Double Velour (n = 15) and Microvel Double Velour (n = 5). There were 16 aortobifemoral bypass grafts, 1 aorto-biiliac, 1 aorto-aortic, 1 iliofemoral, and 1 axillobifemoral. The longitudinal ruptures occurred on two specific parts of the prostheses: the guide line (6 cases) and the remeshing line (11 cases). In three cases both lines were affected. Scanning electron microscopy showed major degradation of the trilobar filaments of the velour and gradual ruptures of the flat filaments of the remeshing and guide lines. CONCLUSIONS: In this study, we have identified a specific mechanism of late (9-20 years) longitudinal rupture of knitted polyester prostheses consisting of degradation of the polyester filaments along the remeshing and guide lines that run the length of the graft.


Assuntos
Prótese Vascular , Poliésteres , Falha de Prótese , Aorta Abdominal/cirurgia , Implante de Prótese Vascular , Artéria Femoral/cirurgia , Humanos , Artéria Ilíaca/cirurgia , Microscopia Eletrônica de Varredura , Fatores de Tempo
18.
Ann Vasc Surg ; 14(6): 543-52, 2000 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-11128447

RESUMO

The purpose of this study was to develop a sealing technique for polyester prosthetic grafts able to promote healing and reduce intimal hyperplasia. The porcine experimental model was aortoiliac bypass with a 6-mm diameter knitted polyester prosthetic graft implanted for 14 and 90 days. Animals were divided into three groups according to sealing technique as follows: pre-clotting with blood (group I, n = 12), sealing with autologous fibrin glue (group II, n = 14), and sealing with autologous fibrin glue and bone marrow cells (group III, n = 16). Feasibility and quality of sealing were evaluated by scanning electron microscopy prior to implantation and by assessment of blood loss. After removal, prostheses were cut into three segments comprising the proximal anastomosis, midsection, and distal anastomosis. Pieces were fixed, embedded in paraffin, and serially sectioned for histologic study. Histological study focused on the degree of stenosis and hyperplasia of the neointima of each prosthesis. The results of this short-term study indicate that sealing of polyester vascular prosthetic grafts with autologous fibrin glue and bone marrow cells is effective in reducing intimal hyperplasia. However further study will be needed to assess long-term healing.


Assuntos
Aorta Abdominal/cirurgia , Prótese Vascular , Materiais Revestidos Biocompatíveis , Adesivo Tecidual de Fibrina , Artéria Ilíaca/cirurgia , Polietilenotereftalatos , Animais , Aorta Abdominal/patologia , Feminino , Hiperplasia , Artéria Ilíaca/patologia , Microscopia Eletrônica de Varredura , Propriedades de Superfície , Suínos , Túnica Íntima/patologia , Túnica Íntima/cirurgia
19.
Eur J Vasc Endovasc Surg ; 18(5): 375-80, 1999 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-10612641

RESUMO

OBJECTIVES: to characterise the impact of the crimping of polyester prostheses on the fluid flow kinetics. DESIGN: an experimental in vitro study. MATERIALS AND METHODS: we investigated four models of polyester vascular prostheses in a continuous laminar flow circuit. The flow velocity was 80 ml/s for all experiments. We studied two fluids of different viscosity within the circuit. The speed of the particles was measured by a laser Doppler anemometer 2 to 52 mm from the prosthetic interface. We first established a calibrated flow-velocity profile corresponding to the study of the support inside the circuit without any prosthesis. We measured the velocity profiles for each prosthesis corresponding to four crimp densities obtained by stretching the grafts. RESULTS: the crimping of PET textile prostheses led to a decrease of flow velocity especially closer to the prosthetic surface. The decrease of flow velocity was dependent on the model of prosthesis. This decrease of flow velocity is described by the following negative exponential law: DeltaV=a times b(-x)where (a) is the crimp density and (b) the fluid viscosity. CONCLUSIONS: flow velocity near a prosthetic surface is influenced by the morphology of the crimping. The impact of crimping on the flow velocity in a vascular prosthesis can be predicted by computer simulation models. This may provide the optimal shape of crimping for each prosthesis.


Assuntos
Velocidade do Fluxo Sanguíneo , Prótese Vascular , Poliésteres , Prótese Vascular/estatística & dados numéricos , Calibragem , Humanos , Cinética , Fluxometria por Laser-Doppler , Modelos Cardiovasculares , Desenho de Prótese/métodos , Desenho de Prótese/estatística & dados numéricos , Viscosidade
20.
J Mal Vasc ; 24(3): 229-32, 1999 Jun.
Artigo em Francês | MEDLINE | ID: mdl-10467535

RESUMO

We report the case of an 84 year-old man who suffered of paraplegia after surgery of an abdominal aortic aneurysm. The neurologic status did not improve during 5 years of follow-up. This complication is rare in light of the review of the literature. It is more frequent after emergency (1.4%) and redux (19%) surgery than after elective surgery (1.1%). Its mechanisms are anatomic (occlusion of the Adamkievitz artery and of the pelvic collateral arteries) and hemodynamic mechanisms (thromboembolism, low systemic tension, long supra-renal clamping). Since pre-operative aortography to detect anatomic variations is not realistic, its only prevention remains maintenance of intra-operative hemodynamic, systemic heparinization, and preservation of the pelvic collateral circulation.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Paraplegia/etiologia , Complicações Pós-Operatórias , Idoso , Idoso de 80 Anos ou mais , Humanos , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA