Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Am J Cardiol ; 99(9): 1316-20, 2007 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-17478165

RESUMO

Patent foramen ovale (PFO) has been implicated in the pathogenesis of cryptogenic stroke, arterial desaturation, decompression illness, and migraine headache (MH). This study evaluated the safety of percutaneous transcatheter PFO closure in patients with cryptogenic stroke, transient ischemic attack, or arterial desaturation. Additionally, symptomatic reduction in MH was determined after interatrial shunt closure. Of the 252 patients referred to the University of California, Los Angeles, with PFO, 131 underwent closure of the interatrial communication with a CardioSEAL (n = 30) or Amplatzer (n = 101) device. PFO morphology was evaluated with transesophageal echocardiography. Follow-up was conducted at 1 to 2 months with echocardiography, with clinical assessment annually thereafter. At an average follow-up of 30 months, there was no recurrence of any thromboembolic event (transient ischemic attack, stroke, or peripheral). There was a reduction in MH, defined as the complete resolution of headache or a >50% reduction in the number of headache days, in 85% of patients after PFO closure. Temporary problems after device implantation, including chest discomfort and palpitations, were reported in 23% of patients and occurred more frequently in patients with nickel hypersensitivity (p <0.05). In conclusion, transcatheter PFO closure is an effective and safe therapeutic modality in the prevention of thromboembolic events and MH associated with interatrial shunting in patients who present with cryptogenic stroke. Pending randomized, controlled trials are necessary to determine if this invasive approach is preferable to medical therapy for the prevention of recurrent stroke or as primary treatment for patients with MH.


Assuntos
Cateterismo Cardíaco , Comunicação Interatrial/terapia , Acidente Vascular Cerebral/prevenção & controle , Adulto , Idoso , Estudos de Coortes , Feminino , Comunicação Interatrial/complicações , Humanos , Hipóxia/etiologia , Hipóxia/prevenção & controle , Embolia Intracraniana/etiologia , Embolia Intracraniana/prevenção & controle , Masculino , Pessoa de Meia-Idade , Transtornos de Enxaqueca/etiologia , Transtornos de Enxaqueca/prevenção & controle , Próteses e Implantes , Estudos Retrospectivos , Acidente Vascular Cerebral/etiologia , Resultado do Tratamento
2.
Rev Cardiovasc Med ; 5(3): 170-5, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15346101

RESUMO

When a middle-aged woman with a complex cardiac history presented with a cardiac mass in the setting of an evolving myocardial infarction, it created a diagnostic dilemma. This case report describes the diagnostic evaluation of such a patient and discusses the rare finding of an intramyocardial hematoma.


Assuntos
Neoplasias Cardíacas/diagnóstico , Hemangioma/diagnóstico , Infarto do Miocárdio/diagnóstico , Cateterismo Cardíaco , Angiografia Coronária , Diagnóstico Diferencial , Ecocardiografia Transesofagiana , Feminino , Septos Cardíacos/diagnóstico por imagem , Septos Cardíacos/patologia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/patologia , Hematoma/diagnóstico , Humanos , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X
3.
Am J Cardiol ; 93(4): 426-31, 2004 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-14969615

RESUMO

Transcatheter closure for atrial septal defect (ASD) and patent foramen ovale (PFO) is a promising alternative to surgical closure or anticoagulant therapy. A potential complication is thrombus formation on the device after implantation. From February 2001 to June 2003, 66 patients with atrial communication were treated successfully with the Amplatzer device (16 septal and 20 PFO occluders) or the CardioSEAL device (30). Patients were discharged on antiplatelet medication (aspirin and clopidogrel) and/or anticoagulation. Fifty patients (76%) had transesophageal echocardiography (TEE) 1 month after device implantation (28 +/- 10 days). No patient experienced a thromboembolic episode during follow-up. TEE revealed that thrombus formation occurred more frequently on the CardioSEAL device (5 of 23 patients; 22%) than on the Amplatzer device (0 of 27 patients; 0%) (p = 0.02). Although thrombus disappeared or markedly diminished after additional anticoagulation therapy in 3 patients, 1 patient had surgical explantation of the device due to progressive increase in the size of thrombus with hypermobility despite intensive anticoagulation therapy. There was no variable associated with the presence of thrombus formation on the occluder other than the use of the CardioSEAL device. One month after insertion, the CardioSEAL device is more likely to have thrombus present than the Amplatzer device.


Assuntos
Procedimentos Cirúrgicos Cardíacos/instrumentação , Trombose Coronária/epidemiologia , Comunicação Interatrial/cirurgia , Adolescente , Adulto , Idoso , Cateterismo Cardíaco , Distribuição de Qui-Quadrado , Ecocardiografia Transesofagiana , Feminino , Comunicação Interatrial/diagnóstico por imagem , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...