Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
JAMA ; 244(19): 2196-8, 1980 Nov 14.
Artigo em Inglês | MEDLINE | ID: mdl-7420725

RESUMO

Recent investigations have demonstrated that exercise-induced asthma (EIA) can be prevented by inspiration of warm, fully humidified air during exercise. We evaluated the success of a surgical face mask, used to retain warm, humidified, expired air, in preventing EIA in ten asthmatic children. subjects underwent six minutes of exercise on a treadmill during two sessions, in one session breathing room air and in another wearing a mask covering the nose and mouth. On the control day, average group forced expiratory volume in 1 s (FEV1) and maximal midexpiratory flow rate (MMEF) decreased from the preexercise baseline value to 66% and 47% of baseline, respectively, at six minutes; on the mask day, FEV1 and MMEF were 91% and 82% of the baseline values (increased in all subjects). A simple face mask may be an inexpensive, nonpharmacologic alternative for alleviation of EIA.


Assuntos
Asma Induzida por Exercício/prevenção & controle , Asma/prevenção & controle , Máscaras/normas , Adolescente , Criança , Feminino , Volume Expiratório Forçado , Humanos , Masculino , Fluxo Máximo Médio Expiratório , Esforço Físico , Testes de Função Respiratória
2.
J Appl Physiol ; 40(6): 982-3, 1976 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-931940

RESUMO

The VO2max response of 12 well-trained and highly motivated college males was measured using two treadmill protocols: horizontal (H) and inclined (I). The duration of each test averaged 10 min. In the H test the treadmill bed was horizontal with the running rate held constant for the first 6 min, after which time it was increased at 1-min intervals to near maximal subject running speed, according to the HR response, until exhaustion. The I method simulated the protocol of Costill and Fox, with the treadmill speed at about 80-90% of mean maximal running rate established from 12- and 15-min track runs. The treadmill bed was held horizontal during the first 4 min, after which time it was elevated to 4% and elevated 2% each 2 min thereafter until exhaustion. No significant differences were found in VO2max, 4.267 1/min (I), and 4.192 1/min (H), average max HR, 190.4/MIN (I), and 188.9/min (H); respiratory rate, 56.4/min (I), and 62.0/min (H); and VEBTPS, 145.2 1/min (I), and 143.3 1/min (H). It was concluded that the intensities of both treadmill methods, H and I, were sufficient to produce a nonsignificant difference in maximal VO2 values with the type subjects employed.


Assuntos
Oxigênio , Esforço Físico , Respiração , Adulto , Humanos , Masculino , Corrida
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...