Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 38
Filtrar
2.
J Am Coll Radiol ; 21(1): 165-174, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37517770

RESUMO

OBJECTIVES: Low back pain is a common clinical presentation that often results in expensive and unnecessary imaging that may lead to undue patient harm, including unnecessary procedures. We present an initiative in a safety net system to reduce imaging for low back pain. METHODS: This quality improvement study was conducted across 70 ambulatory clinics and 11 teaching hospitals. Three electronic health record changes, using the concept of a nudge, were introduced into orders for lumbar radiography (x-ray), lumbar CT, and lumbar MRI. The primary outcome was the number of orders per 1,000 patient-days or encounters for each imaging test in the inpatient, ambulatory, and emergency department (ED) settings. Variation across facilities was assessed, along with selected indications. RESULTS: Across all clinical environments, there were statistically significant decreases in level differences pre- and postintervention for lumbar x-ray (-52.9% for inpatient encounters, P < .001; -23.7% for ambulatory encounters, P < .001; and -17.3% for ED only encounters, P < .01). There was no decrease in ordering of lumbar CTs in the inpatient and ambulatory settings, although there was an increase in lumbar CTs in ED-only encounters. There was no difference in lumbar MRI ordering. Variation was seen across all hospitals and clinics. DISCUSSION: Our intervention successfully decreased lumbar radiography across all clinical settings, with a reduction in lumbar CTs in the inpatient and ambulatory settings. There were no changes for lumbar MRI orders.


Assuntos
Dor Lombar , Humanos , Dor Lombar/diagnóstico por imagem , Radiografia , Imageamento por Ressonância Magnética , Região Lombossacral , Procedimentos Desnecessários
3.
J Gen Intern Med ; 39(1): 13-18, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37429975

RESUMO

BACKGROUND: According to the American Association of Blood Banks, a Type and Screen (T&S) is valid for up to three calendar days. Beyond a limited number of clinical indications such as a transfusion reaction, repeat T&S testing within 3 days is not warranted. Inappropriate repeat T&S testing is a costly medical waste and can lead to patient harm. OBJECTIVE: To reduce inappropriate duplicate T&S testing across a large, multihospital setting. SETTING: The largest urban safety net health system in the USA, with 11 acute care hospitals. INTERVENTIONS: Our first intervention involved adding the time elapsed since the last T&S order into the order and the process instructions that described when a T&S was indicated. The second intervention was a best practice advisory that triggered when T&S was ordered before the expiration of an active T&S. MAIN MEASURES: The primary outcome measure was the number of duplicate inpatient T&S per 1000 patient days. KEY RESULTS: Across all hospitals, the weekly average rate of duplicate T&S ordering decreased from 8.42 to 7.37 per 1000 patient days (12.5% reduction, p < 0.001) after the first intervention and to 4.32 per 1000 patient days (48.7% reduction, p < 0.001) after the second intervention. Using linear regression to compare pre-intervention to post-intervention 1, the level difference was - 2.46 (9.17 to 6.70, p < 0.001) and slope difference was 0.0001 (0.0282 to 0.0283, p = 1). For post-intervention 1 to post-intervention 2, the level difference was - 3.49 (8.06 to 4.58, p < 0.001) and slope difference was - 0.0428 (0.0283 to - 0.0145, p < 0.05). CONCLUSIONS: Our intervention successfully reduced duplicate T&S testing using a two-pronged electronic health record intervention. The success of this low effort intervention across a diverse health system provides a framework for similar interventions in various clinical settings.


Assuntos
Registros Eletrônicos de Saúde , Hospitais , Humanos
4.
Am J Clin Pathol ; 161(4): 388-392, 2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38041859

RESUMO

OBJECTIVES: National societies recommend against performing routine daily laboratory testing without a specific indication. Unnecessary testing can lead to patient harm, such as hospital-acquired anemia. The objective of this study was to reduce repeat complete blood counts (CBCs) after initial testing. METHODS: This was a quality improvement initiative implemented across 11 safety net hospitals in New York City. A best practice advisory (BPA) was implemented that asked the user to remove a CBC if the last 2 CBCs within 72 hours had normal white blood cell and platelet counts and unchanged hemoglobin levels. The outcome measure was the rate of CBCs per 1000 patient days preintervention (January 8, 2020, to December 22, 2020) to postintervention (December 23, 2020, to December 7, 2021). The process measure was the acceptance rate of the BPA, defined as the number of times the repeat CBC order was removed through the BPA divided by the total number of times the BPA triggered. RESULTS: Across 11 hospitals, repeat CBC testing decreased by 12.3% (73.05 to 64.04 per 1000 patient days, P < .001). Six of the 11 hospitals exhibited statistically significant decreases, ranging from a 10% to 48.9% decrease of repeat CBCs. The overall BPA action rate was 20.0% (24,029 of 119,944 repeat CBCs). CONCLUSIONS: This low-effort, electronic health record-based intervention can effectively reduce unnecessary laboratory testing.


Assuntos
Anemia , Provedores de Redes de Segurança , Humanos , Contagem de Células Sanguíneas , Contagem de Plaquetas , Laboratórios , Procedimentos Desnecessários
5.
Qual Manag Health Care ; 33(2): 94-100, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37817318

RESUMO

BACKGROUND AND OBJECTIVES: As the COVID-19 pandemic brought surges of hospitalized patients, it was important to focus on reducing overuse of tests and procedures to not only reduce potential harm to patients but also reduce unnecessary exposure to staff. The objective of this study was to create a Choosing Wisely in COVID-19 list to guide clinicians in practicing high-value care at our health system. METHODS: A Choosing Wisely in COVID-19 list was developed in October 2020 by an interdisciplinary High Value Care Council at New York City Health + Hospitals, the largest public health system in the United States. The first phase involved gathering areas of overuse from interdisciplinary staff across the system. The second phase used a modified Delphi scoring process asking participants to rate recommendations on a 5-point Likert scale based on criteria of degree of evidence, potential to prevent patient harm, and potential to prevent staff harm. RESULTS: The top 5 recommendations included avoiding tracheal intubation without trial of noninvasive ventilation (4.4); not placing routine central venous catheters (4.33); avoiding routine daily laboratory tests and batching laboratory draws (4.19); not ordering daily chest radiographs (4.17); and not using bronchodilators in the absence of reactive airway disease (4.13). CONCLUSION: We successfully developed Choosing Wisely in COVID-19 recommendations that focus on evidence and preventing patient and staff harm in a large safety net system to reduce overuse.


Assuntos
COVID-19 , Humanos , Estados Unidos , COVID-19/epidemiologia , COVID-19/prevenção & controle , Pandemias/prevenção & controle , Cidade de Nova Iorque/epidemiologia
6.
Am J Emerg Med ; 73: 88-94, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37633078

RESUMO

BACKGROUND: Prothrombin/international normalized ratio and activated partial thromboplastin time (PT/INR and aPTT) are frequently ordered in emergency departments (EDs), but rarely affect management. They offer limited utility outside of select indications. Several quality improvement initiatives have shown reduction in ED use of PT/INR and aPTT using multifaceted interventions in well-resourced settings. Successful reduction of these low-value tests has not yet been shown using a single intervention across a large hospital system in a safety net setting. This study aims to determine if an intervention of two BPAs is associated with a reduction in PT/INR and aPTT usage across a large safety net system. METHODS: This initiative was set at a large safety net system in the United States with 11 acute care hospitals. Two Best Practice Advisories (BPAs) discouraging inappropriate PT/INR and aPTT use were implemented from March 16, 2022-August 30, 2022. Order rate per 100 ED patients during the pre-intervention period was compared to the post-intervention period on both the system and individual hospital level. Complete blood count (CBC) testing served as a control, and packed red blood cell transfusions served as a balancing measure. An interrupted time series regression analysis was performed to capture immediate and temporal changes in ordering for all tests in the pre and post-intervention periods. RESULTS: PT/INR tests exhibited an absolute decline of 4.11 tests per 100 ED encounters (95% confidence interval -5.17 to -3.05; relative reduction of 18.9%). aPTT tests exhibited absolute decline of 4.03 tests per 100 ED encounters (95% CI -5.10 to -2.97; relative reduction of 19.8%). The control measure, CBC, did not significantly change (-0.43, 95% CI -2.83 to 1.96). Individual hospitals showed variable response, with absolute reductions from 2.02 to 9.6 tests per 100 ED encounters for PT/INR (relative reduction 12.1%-30.5%) and 2.07 to 10.04 for aPTT (relative reduction 12.1%-31.4%). Regression analysis showed that the intervention caused an immediate 25.7% decline in PT/INR and 24.7% decline in aPTT tests compared to the control measure. The slope differences (rate of order increase pre vs post intervention) did not significantly decline compared to the control. CONCLUSIONS: This BPA intervention reduced PT/INR and aPTT use across 11 EDs in a large, urban, safety net system. Further study is needed in implementation to other non-safety net settings.

7.
Am J Clin Pathol ; 160(6): 585-592, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-37549105

RESUMO

OBJECTIVES: C-reactive protein (CRP) and erythrocyte sedimentation rate (ESR) are commonly used inflammatory markers. C-reactive protein is more sensitive and specific for monitoring acute inflammation. However, it is commonly co-ordered with ESR despite recommendations against this. Our objective was to reduce unnecessary ESR orders and ESR/CRP co-ordering rates across a large safety net health system. METHODS: This was a quality improvement project that used a quasi-experimental pre- and postintervention interrupted time-series regression analysis. Patients with a positive COVID-19 test were excluded. We designed a nonintrusive, normative nudge within the ESR order that recommended against co-ordering ESR and CRP. In addition, a best practice advisory triggered when ESR and CRP were simultaneously ordered. The outcome measures were ESR order rates per 1000 patient days in the inpatient setting and per 1000 patient encounters in the outpatient setting, as well as ESR/CRP co-ordering rates. RESULTS: Inpatient ESR orders decreased from 12.02 preintervention to 5.61 per 1000 patient days (-53.3%, P < .001). Outpatient ESR orders decreased from 6.09 to 4.07 per 1000 patient encounters (-33.2%, P < .001). Relative co-ordering rates decreased by 50%. CONCLUSIONS: This electronic health record initiative successfully reduced ESR testing across 11 hospitals and 70 ambulatory centers in a safety net setting.


Assuntos
Proteína C-Reativa , Registros Eletrônicos de Saúde , Humanos , Proteína C-Reativa/análise , Sedimentação Sanguínea , Biomarcadores
9.
Am J Emerg Med ; 71: 63-68, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37343340

RESUMO

BACKGROUND: The United States continues to face a significant issue with opioid misuse, overprescribing, dependency, and overdose. Electronic health record (EHR) interventions have shown to be an effective tool to modify opioid prescribing behaviors. This quality improvement project describes an EHR intervention to reduce daily dosing in opioid prescriptions in 11 emergency departments (ED) across the largest safety net health system in the US. MEASURES: The primary outcome measure was the rates of oxycodone-acetaminophen 5-325 mg prescriptions exceeding 50 morphine milligram equivalents per day (MMED) pre- vs. post-intervention; and stratified by individual hospitals and provider type. INTERVENTION: The defaults for dose and frequency were uniformly changed to 'every 6 hours as needed' and '1 tablet', respectively, across 11 EDs. OUTCOMES: The percentage of prescriptions greater than or equal to 50 MMED decreased from 46.0% (1624 of 3530 prescriptions) to 1.6% (52 of 3165 prescriptions) (96.4% relative reduction; p < 0.001). All 11 hospitals had a significant reduction in prescriptions exceeding 50 MMED. Nurse practitioners had the highest relative reduction of prescriptions exceeding 50 MMED at 100% (p < 0.001), and the attendings/fellows had the lowest relative reduction at 95.6% (p < 0.001). CONCLUSIONS/LESSONS LEARNED: Default nudges are a simple yet powerful intervention that can strongly influence opioid prescribing patterns.


Assuntos
Analgésicos Opioides , Overdose de Drogas , Humanos , Estados Unidos , Analgésicos Opioides/uso terapêutico , Padrões de Prática Médica , Overdose de Drogas/tratamento farmacológico , Overdose de Drogas/prevenção & controle , Morfina , Prescrições , Serviço Hospitalar de Emergência , Prescrições de Medicamentos
11.
Am J Clin Pathol ; 160(3): 292-296, 2023 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-37202882

RESUMO

OBJECTIVES: To develop a system-wide electronic health record (EHR) intervention at a large safety-net hospital system to reduce wasteful duplicate genetic testing. METHODS: This project was initiated at a large urban public health care system. An EHR alert was designed to be triggered when a clinician attempted to order any of 16 specified genetic tests for which a previous result existed within the EHR system. Measurements included the proportion of completed genetic tests that were duplicates and alerts per 1,000 tests. Data were stratified by clinician type, specialty, and inpatient vs ambulatory setting. RESULTS: Across all settings, the rate of duplicate genetic testing decreased from 2.35% (1,050 of 44,592 tests) to 0.09% (21 of 22,323 tests) (96% relative reduction, P < .001). The alert rate per 1,000 tests was 277 for inpatient orders and 64 for ambulatory orders. Among clinician types, residents had the highest alert rate per 1,000 tests at 166 and midwives the lowest at 51 (P < .01). Among clinician specialties, internal medicine had the highest alert rate per 1,000 tests at 245 and obstetrics and gynecology the lowest at 56 (P < .01). CONCLUSIONS: The EHR intervention successfully reduced duplicate genetic testing by 96% across a large safety-net setting.

12.
Jt Comm J Qual Patient Saf ; 49(6-7): 306-312, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37137754

RESUMO

INTRODUCTION: A 4T score with intermediate or high probability of heparin-induced thrombocytopenia prompts ordering of anti-platelet 4 heparin complex. If positive, a serotonin release assay (SRA) is recommended to confirm diagnosis. Despite these recommendations, overtesting of both anti-platelet 4 and SRA is highly prevalent. METHODS: This was a quality improvement initiative using two forms of clinical decision support across 11 acute care hospitals. First, a 4T calculator was incorporated into anti-platelet 4 orders. Second, a Best Practice Advisory fired when anti-platelet 4 and SRA were ordered simultaneously, prompting the provider to remove the SRA order. Data were analyzed by a quasi-experimental interrupted time series linear regression comparing weekly average laboratory tests per 1,000 patient-days pre- and postintervention. RESULTS: Average ordering frequency of anti-platelet 4 changed from 0.508 to 0.510 per 1,000 patient-days (0.5%, p = 0.42) without significant slope or level differences. Average ordering frequency of SRA decreased from 0.430 to 0.289 per 1,000 patient-days (32.8%, p < 0.001) with a significant level difference of -0.128 orders per 1,000 patient-days (-31.2%, p < 0.05). CONCLUSION: A simultaneous Best Practice Advisory was effective in reducing SRA orders, but not anti-platelet 4 orders.


Assuntos
Heparina , Trombocitopenia , Humanos , Heparina/efeitos adversos , Serotonina/efeitos adversos , Anticoagulantes/efeitos adversos , Trombocitopenia/induzido quimicamente , Trombocitopenia/diagnóstico , Análise de Séries Temporais Interrompida
13.
J Gen Intern Med ; 38(10): 2326-2332, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37131103

RESUMO

BACKGROUND: 25-Hydroxyvitamin D testing is increasing despite national guidelines and Choosing Wisely recommendations against routine screening. Overuse can lead to misdiagnosis and unnecessary downstream testing and treatment. Repeat testing within 3 months is a unique area of overuse. OBJECTIVE: To reduce 25-hydroxyvitamin D testing in a large safety net system comprising 11 hospitals and 70 ambulatory centers. DESIGN: This was a quality improvement initiative with a quasi-experimental interrupted time series design with segmented regression. PARTICIPANTS: All patients in the inpatient and outpatient settings with at least one order for 25-hydroxyvitamin D were included in the analysis. INTERVENTIONS: An electronic health record clinical decision support tool was designed for inpatient and outpatient orders and involved two components: a mandatory prompt requiring appropriate indications and a best practice advisory (BPA) focused on repeat testing within 3 months. MAIN MEASURES: The pre-intervention period (6/17/2020-6/13/2021) was compared to the post-intervention period (6/14/2021-8/28/2022) for total 25-hydroxyvitamin D testing, as well as 3-month repeat testing. Hospital and clinic variation in testing was assessed. Additionally, best practice advisory action rates were analyzed, separated by clinician type and specialty. KEY RESULTS: There were 44% and 46% reductions in inpatient and outpatient orders, respectively (p < 0.001). Inpatient and outpatient 3-month repeat testing decreased by 61% and 48%, respectively (p < 0.001). The best practice advisory true accept rate was 13%. CONCLUSION: This initiative successfully reduced 25-hydroxyvitamin D testing through the use of mandatory appropriate indications and a best practice advisory focusing on a unique area of overuse: the repeat testing within a 3-month interval. There was wide variation among hospitals and clinics and variation among clinician types and specialties regarding actions to the best practice advisory.


Assuntos
Sistemas de Apoio a Decisões Clínicas , Vitamina D , Humanos , Melhoria de Qualidade , Análise de Séries Temporais Interrompida
14.
J Hosp Med ; 18(6): 502-508, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37051635

RESUMO

BACKGROUND: While pharmacologic prophylaxis has benefits for venous thromboembolism (VTE) prevention in high-risk patients, unnecessary use carries potential harm, including bleeding, heparin-induced thrombocytopenia, and patient discomfort, and should be avoided in low-risk patients. While many quality improvement initiatives aim to reduce underuse, successful models on reducing overuse are sparse in the literature. OBJECTIVE: We aimed to create a quality improvement initiative to reduce overuse of pharmacologic VTE prophylaxis. DESIGNS, SETTINGS AND PARTICIPANTS: A quality improvement initiative was implemented across 11 safety net hospitals in New York City. INTERVENTION: The first electronic health record (EHR) intervention consisted of a VTE order panel that facilitated risk assessment and recommended VTE prophylaxis for high-risk patients only. The second EHR intervention used a best practice advisory that alerted clinicians when prophylaxis was ordered for a patient previously deemed "low risk." Prescribing rates were compared through a three-segment interrupted time series linear regression design. RESULTS: Compared to the preintervention period, the first intervention did not change the rate of total pharmacologic prophylaxis immediately after implementation (1.7% relative change, p = .38) or over time (slope difference of 0.20 orders per 1000 patient days, p = .08). Compared to the first intervention period, the second intervention led to an immediate 4.5% reduction in total pharmacologic prophylaxis (p = .04) but increased thereafter (slope difference of 0.24, p = .03) such that weekly rates at the end of the study were similar to rates prior to the second intervention.


Assuntos
Tromboembolia Venosa , Humanos , Tromboembolia Venosa/prevenção & controle , Tromboembolia Venosa/tratamento farmacológico , Registros Eletrônicos de Saúde , Anticoagulantes/efeitos adversos , Hospitais , Fatores de Risco
15.
Jt Comm J Qual Patient Saf ; 49(6-7): 291-296, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37024423

RESUMO

BACKGROUND: Asymptomatic severe hypertension (also known as hypertensive urgency) is frequently encountered in the hospital. Previous evidence suggests that management with one-time doses of intravenous (IV) antihypertensives may increase adverse events. Despite this, single-dose treatment remains common in the emergency department and inpatient settings. METHODS: This quality initiative was launched at New York City Health + Hospitals, the largest safety net hospital system in the United States. The initiative involved two changes to electronic orders for IV hydralazine and IV labetalol: a nonintrusive advisory statement within the order instructions and a mandatory requirement to document the indication for IV antihypertensive use. RESULTS: This initiative took place from November 2021 to October 2022. Of the indications selected for IV antihypertensive orders, 60.7% were for hypertensive emergency, 15.3% were for patients who were strictly NPO, 21.2% were for other, and 2.8% selected more than one indication. For ED-only encounters, aggregate IV hydralazine and IV labetalol orders per 1,000 patient encounters were 2.53 preintervention and 1.55 postintervention (38.7% reduction, p < 0.001). For inpatient encounters, aggregate IV hydralazine and IV labetalol orders per 1,000 patient-days were 18.25 preintervention and 15.81 postintervention (13.4% reduction, p < 0.001). Similar trends were observed for individual orders of IV hydralazine and IV labetalol. There were significant reductions in 7 of the 11 hospitals in inpatient administration of aggregate IV hydralazine and labetalol orders per 1,000 patient-days. CONCLUSION: This quality improvement initiative successfully reduced unnecessary IV antihypertensive use in an 11-hospital safety net system.


Assuntos
Sistemas de Apoio a Decisões Clínicas , Hipertensão , Labetalol , Humanos , Anti-Hipertensivos/efeitos adversos , Labetalol/efeitos adversos , Hipertensão/tratamento farmacológico , Pressão Sanguínea , Hidralazina/efeitos adversos
16.
Am J Infect Control ; 51(4): 461-465, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36870917

RESUMO

BACKGROUND: Treatment of asymptomatic bacteriuria (ASB) is common. Overtreatment of ASB leads to harm, including adverse effects from antibiotics, antibiotic resistance, and increased length of stay. METHODS: This quality improvement initiative targeted inappropriate urine cultures across 11 hospitals in a safety-net setting. A mandatory prompt for appropriate indications for urine culture orders and a best practice advisory (BPA) for urine culture on patients with urinary catheters were created. Urine culture ordering was compared pre-intervention (6/2020 to 10/2021) to post-intervention (12/2021 to 8/2022). Catheter associated urinary tract infections (CAUTI) was compared pre- and post-intervention. Variation in urine culture ordering and CAUTI rates in hospitals were assessed. RESULTS: Inpatient urine cultures decreased by 20.9% (p<0.001). Inpatient urine cultures on patients with urinary catheters decreased by 21.6% (p<0.001). CAUTI rates remained unchanged post-intervention. High variation in urine culture ordering and CAUTI rates was seen among hospitals. CONCLUSIONS: This initiative successfully decreased urine cultures in a large, safety-net system. Further study is needed in assessing variation among hospitals.


Assuntos
Bacteriúria , Infecções Relacionadas a Cateter , Infecções Urinárias , Humanos , Bacteriúria/diagnóstico , Bacteriúria/tratamento farmacológico , Bacteriúria/etiologia , Infecções Urinárias/etiologia , Antibacterianos/uso terapêutico , Hospitais , Cateteres Urinários/efeitos adversos , Infecções Relacionadas a Cateter/etiologia
17.
Infect Control Hosp Epidemiol ; 44(9): 1381-1385, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-36960818

RESUMO

BACKGROUND: Peripherally inserted central catheters (PICCs) are increasingly used for vascular access in inpatient settings. Compared to multilumen PICCs, single-lumen PICCs carry a lower rate of complications, including central-line-associated bloodstream infection and thrombosis. Despite this, multilumen PICCs are still overused. METHODS: This quality improvement initiative was implemented across 11 hospitals at New York City Health + Hospitals safety net system. The electronic health record (EHR) interventional radiology or vascular access team consultation orders were modified to allow for lumen choice, with default selection to a single-lumen PICC. RESULTS: Average single-lumen PICC utilization increased by 25.5%, from 44.4% to 69.9% (P < .001). CLABSI rates had a nonsignificant reduction by 26.7% from 2.44 to 1.79 infections per month (P = .255). Among provider types in the postintervention period, single-lumen PICC utilization ranged from 67.7% for advanced practice providers to 82.4%-94.6% for physicians. Among provider specialties, utilization ranged from 31.8% for neurology to 97.7% for orthopedics. Additionally, there was large variation in pre- and postintervention differences in utilization by hospital. CONCLUSIONS: We successfully increased single-lumen PICC utilization across all 11 safety net hospitals. This expands on previous work on improving single-lumen PICC use and use of default nudges in large, resource-limited settings. Further study is needed to examine variation among provider types, specialties, and hospitals.


Assuntos
Infecções Relacionadas a Cateter , Cateterismo Venoso Central , Cateterismo Periférico , Cateteres Venosos Centrais , Humanos , Cateterismo Venoso Central/efeitos adversos , Estudos Retrospectivos , Infecções Relacionadas a Cateter/epidemiologia , Infecções Relacionadas a Cateter/prevenção & controle , Fatores de Risco , Catéteres
18.
Am J Infect Control ; 51(10): 1139-1144, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-36965778

RESUMO

BACKGROUND: Diarrhea that develops in patients after 72 hours of hospitalization is likely to have a nosocomial or iatrogenic etiology. Testing with stool cultures and stool ova and parasites (O&P) is not recommended. Our goal was to reduce this inappropriate testing within a large, urban safety-net hospital system. METHODS: This was a quality improvement project. We created a best practice advisory (BPA) within the electronic medical record that fires when a stool culture or O&P order is placed 72 hours after admission for any immunocompetent patient. It states that stool testing is low yield and offers the option to remove the order. We measured weekly counts of stool culture and stool O&P orders pre- and postintervention. We also measured the BPA acceptance rate, the 24-hour stool testing reorder rate, and Clostridioides difficile infection rates. Data were analyzed using Welch tests as well as a quasi-experimental pre- and postintervention interrupted time series regression analysis. RESULTS: Stool culture orders decreased by 24.4% (P < .001). There was a significant level difference and slope difference with linear regression. Five of the 11 hospitals had a significant reduction in stool culture orders. Stool O&P orders decreased by 18.2% (P < .01). Three of the 11 hospitals had a significant reduction in stool O&P orders. CONCLUSIONS: Our intervention successfully reduced inappropriate stool testing within a large safety-net hospital system.


Assuntos
Infecções por Clostridium , Infecção Hospitalar , Parasitos , Humanos , Animais , Infecção Hospitalar/diagnóstico , Infecção Hospitalar/prevenção & controle , Infecção Hospitalar/complicações , Estudos Retrospectivos , Diarreia/diagnóstico , Diarreia/etiologia , Hospitais , Infecções por Clostridium/complicações , Fezes
19.
J Gen Intern Med ; 38(6): 1541-1546, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36829048

RESUMO

BACKGROUND: Educating medical trainees to practice high value care is a critical component to improving quality of care and should be introduced at the beginning of medical education. AIM: To create a successful educational model that provides medical students and junior faculty with experiential learning in quality improvement and mentorship opportunities, and produce effective quality initiatives. SETTING: A tertiary medical center affiliated with a medical school in New York City. PARTICIPANTS: First year medical students, junior faculty in hospital medicine, and a senior faculty course director. PROGRAM DESCRIPTION: The Student High Value Care initiative is a longitudinal initiative comprised of six core elements: (1) project development, (2) value improvement curriculum, (3) mentorship, (4), Institutional support, (5) scholarship, and (6) student leadership. PROGRAM EVALUATION: During the first 3 years, 68 medical students and ten junior faculty participated in 10 quality improvement projects. Nine projects were successful in their measured outcomes, with statistically significant improvements. Nine had an abstract accepted to a regional or national meeting, and seven produced publications in peer-reviewed literature. DISCUSSION: In the first 3 years of the initiative, we successfully engaged medical students and junior faculty to create and support the implementation of successful quality improvement initiatives. Since that time, the program continues to offer meaningful mentorship and scholarship opportunities.


Assuntos
Educação Médica , Estudantes de Medicina , Humanos , Bolsas de Estudo , Currículo , Docentes
20.
J Hosp Med ; 18(2): 147-153, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36567609

RESUMO

BACKGROUND: Telemetry is often a scarce resource at hospitals and is important for arrhythmia and myocardial ischemia detection. Overuse of telemetry monitoring leads to alarm fatigue resulting in failure to respond to arrhythmias, patient harm, and possible unnecessary testing. METHODS: This quality improvement initiative was implemented across NYC Health and Hospitals, an 11-hospital urban safety net system. The electronic health record intervention involved the addition of a mandatory indication in the telemetry order and a best practice advisory (BPA) that would fire after the recommended time period for reassessment had passed. RESULTS: The average telemetry hours per patient encounter went from 60.1 preintervention to 48.4 postintervention, a 19.5% reduction (p < .001). When stratified by the 11 hospitals, decreases ranged from 9% to 30%. The BPA had a 53% accept rate and fired 52,682 times, with 27,938 "discontinue telemetry" orders placed. The true accept rate was 50.4%, as there was a 2.6% 24-h reorder rate. There was variation based on clinician specialty and clinician type (attending, fellow, resident, physician associate, nurse practitioner). CONCLUSION: We successfully reduced telemetry monitoring across a multisite safety net system using solely an electronic health record (EHR) intervention. This expands on previous telemetry monitoring reduction initiatives using EHR interventions at single academic sites. Further study is needed to investigate variation across clinician type, specialty, and post-acute sites.


Assuntos
Doença da Artéria Coronariana , Telemetria , Humanos , Telemetria/métodos , Arritmias Cardíacas/diagnóstico , Hospitais , Registros Eletrônicos de Saúde
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...