1.
Environ Int ; 35(3): 614-8, 2009 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19167075

RESUMO

The south region of Sao Paulo city hosts the Guarapiranga dam, responsible for water supply to 25% of the city population. Their surroundings have been subject to intense and irregular occupation by people from very low socioeconomics classes. Measurements undertaken on sediment and particulate materials in the dam revealed concentrations of lead, copper, zinc and cadmium above internationally accepted limits. Epidemiological and toxicological studies undertaken by the World Health Organization in individuals exhibiting lead concentrations in blood, near or below the maximum recommended (10 microg dl(-1)), surprisingly revealed that toxic effects are more intense in individuals belonging to low socioeconomics classes. Motivated by these facts, we aimed at the investigation of chronic incorporation of lead, as well as the use of our BIOKINETICS code, which is based on an accepted ICRP biokinetics model for lead, in order to extrapolate the results from teeth to other organs. The focus of our data taking was children from poor families, living in a small, restrict and allegedly contaminated area in São Paulo city. Thus, a total of 74 human teeth were collected. The average concentration of lead in teeth of children 5 to 10 years old was determined by means of a high-resolution inductively coupled plasma mass spectrometer (ICP-MS). For standardization of the measurements, an animal bone certified material (H-Animal Bone), from the International Atomic Energy Agency, was analyzed. The amount of lead in children living in the surroundings of the dam, was approximately 40% higher than those from the control region, and the average lead concentration was equal to 1.3 microg g(-1) approximately. Grouping the results in terms of gender, tooth type and condition, it was concluded that a carious molar of boys is a much more efficient contamination pathway for lead, resulting in concentrations 70% higher than in the control region. We also inferred the average concentrations of lead in other organs of these children, by making use of our BIOKINETIC code.


Assuntos
Exposição Ambiental , Chumbo/análise , Chumbo/toxicidade , Dente/química , Adolescente , Disponibilidade Biológica , Brasil , Criança , Pré-Escolar , Simulação por Computador , Fator F , Feminino , Humanos , Masculino , Espectrometria de Massas/métodos , Espectrometria de Massas/normas
2.
Anal Bioanal Chem ; 373(3): 183-9, 2002 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-12043022

RESUMO

A simple method combining slurry sampling after cryogenic grinding and the use of a permanent modification of the integrated platform inside the transversely heated graphite atomizer (THGA) was proposed for the determination of Cd and Pb in foods. Potentialities of the cryogenic grinding were evaluated for grinding different materials of difficult homogenization such as high fat and high fiber tissues. Animal and vegetal samples were cut into small pieces and ground in liquid nitrogen for 2 min. Slurries were prepared directly in the autosampler cup after cryogenic grinding by transferring an exact amount of homogeneous powdered material (5-20 mg) to the cup, followed by 1.00 mL of 0.2% (v/v) HNO3 containing 0.04% (v/v) Triton X-100 and sonication for 30 s, before transferring into the platform previously coated with 250 microg W and 200 microg Rh. Use of a tungsten carbide-rhodium permanent modifier combined with NH4H2PO4 conventional modifier improves tube lifetime and increases the pyrolysis temperature for Cd. Homogeneity tests, carried out by comparing the between- and within-batch precision for each kind of sample, showed no significant differences at the 95% confidence level, indicating good homogeneity for 5-20 mg masses. Detection limits were 3.3 ng g(-1) Cd and 75 ng g(-1) Pb for 1% m/v slurries. Results for determination of Cd and Pb in foods slurries were in agreement with those obtained with digested samples, since no statistical differences were found by the paired t-test at the 95% level.


Assuntos
Cádmio/análise , Análise de Alimentos/métodos , Chumbo/análise , Espectrofotometria Atômica/métodos
3.
Fresenius J Anal Chem ; 369(6): 496-501, 2001 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-11336334

RESUMO

A tungsten-rhodium coating on the integrated platform of a transversely heated graphite atomiser (THGA) was used as a permanent chemical modifier for the determination of lead in biological materials by slurry sampling in electrothermal atomic absorption spectrometry (ETAAS). Slurries were sonicated during 20 s before being delivered to the previously W-Rh treated platform. The number of particles of biological materials introduced into the atomiser for delivering 20 microL slurry aliquot ranged from 5,100 to 39,000. The permanent W-Rh modifier remained stable during approximately 300 analytical measurements when 20 microL of slurries containing up to 1.5% m/v were delivered into the atomiser. In addition, the permanent modifier increases the tube lifetime by approximately 100% when compared to untreated integrated platforms. Also, there is less decrease of sensitivity during the atomiser lifetime when compared with the conventional modifiers, resulting in a decreased need of re-calibration during routine analysis and consequently increasing the sample throughput. The atomiser lifetime was limited to the THGA wall durability, because the W-Rh treated platform was intact after more than 650 analytical firings in a medium containing up to 1.5% m/v slurry of biological material. The detection limit based on integrated absorbance was 20 ng g(-1) Pb for 1.50% m/v slurries. Results from the determination of lead in slurries of biological materials using the W-Rh permanent modifier were in agreement with those obtained with digested solutions using Pd + Mg(NO3)2.


Assuntos
Peixes , Indicadores e Reagentes/química , Chumbo/análise , Espectrofotometria Atômica/métodos , Animais , Reprodutibilidade dos Testes
4.
Sci Total Environ ; 260(1-3): 201-11, 2000 Oct 09.
Artigo em Inglês | MEDLINE | ID: mdl-11032128

RESUMO

Mercury (Hg total) fluxes were calculated for rainwater, throughfall and stream water in a small catchment located in the northeastern region of the Brazilian Amazon (Serra do Navio, Amapá State), whose upper part is covered by a natural rainforest and lower part was altered due to deforestation and activities related to manganese mining. The catchment area is 200 km from the nearest gold mining (garimpo). Minimum and maximum Hg concentrations were measured monthly from October 1996 to September 1997 and were 3.5-23.4 ng l(-1) for rainwater, 16.5-82.7 ng l(-1) for throughfall (March-August 1997) and 1.2-6.1 and 4.2-18.8 ng l(-1) for stream water, in natural and disturbed areas, respectively. In the natural area, the inputs were 18.2 microg m 2 year(-1) in rainwater and 72 microg m(-2) year(-1) in throughfall. This enrichment was attributed to dry deposition. The stream output of 2.9 microg m(-2) year(-1) indicates that Hg is being recycled within the forest as other chemical species or is being retained by the soil system, as confirmed by the cumulative Hg burden in the 0-10 cm surface layer, which was 36480 microg m(-2). When the disturbed area of the catchment was included, the stream output was 9.3 microg m(-2), clearly indicating the impact of the deforestation of the lower part of the basin on the release of mercury. The Hg burden in the disturbed area was 7560 microg m(-2) for the 0-10 cm surface layer.


Assuntos
Água Doce/análise , Mercúrio/análise , Árvores , Poluentes Químicos da Água/análise , Brasil , Monitoramento Ambiental , Ouro , Manganês , Mineração , Chuva
5.
Talanta ; 48(3): 695-703, 1999 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-18967510

RESUMO

Electrothermal atomic absorption spectrophotometry of Al in a tungsten coil atomizer was evaluated and applied for its determination in hemodialysis fluid. The system was mounted on a Varian Spectra AA-40 spectrophotometer with continuum background correction and all measurements, in peak height absorbance, were done at 309.3 nm. The purge gas was a mixture of 90% Ar plus 10% H(2). Observation height, gas flow, drying, pyrolysis and atomization steps were optimized. The heating program was carried out by employing a heating cycle in four steps: dry, pyrolysis, atomization and clean. The determination of Al in hemodialysis solutions was performed by using a matrix-matching procedure. Al in hemodialysis solutions was determined by TCA and by electrothermal atomization with a graphite tube atomizer. There is no differences between results obtained by both methods at a confidence level of 95%. The characteristic mass of Al by using the TCA was 39 pg and the detection limit was 2.0 mug l(-1).

6.
Talanta ; 47(3): 613-23, 1998 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-18967363

RESUMO

A method for ytterbium determination in animal faeces by tungsten coil electrothermal atomic absorption spectrometry (TCAAS) was developed. Faeces were dry-ashed in a muffle furnace, the ashes were treated with hydrochloric acid, and 10 mul of sample solution were delivered into 150-W tungsten coil atomizer. A matrix-matching procedure employing a 66-s heating program proved to be efficient for obtaining accurate results. Characteristic mass and detection limit were 7.1 pg and 0.35 mug g(-1) Yb, respectively. The tungsten coil atomizer lifetime exceeded 300 firings with digested solutions and R.S.D. of measurements was 1.9% after ten consecutive injections of 10.0 mug l(-1) Yb. Accuracy of the proposed method was assessed by employing a graphite furnace atomic absorption spectrometric procedure. Application of the paired t-test did not reveal any significant difference for ytterbium contents determined by both methods at 95% confidence level. It was demonstrated that the proposed procedure can successfully be used for evaluation of kinetic passage rate of feed through digestive tract of animals.

7.
Talanta ; 42(12): 2021-6, 1995 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-18966446

RESUMO

Iron interference in the spectrophotometric catalytic determination of molybdenum based on the iodide-hydrogen peroxide reaction can be corrected by using sulphosalicylic acid as masking and color-forming reagent. The catalytic influence of iron ions is circumvented to the extent of about 90% and correction of any remaining iron ions is possible by monitoring the colored iron(III)-salicylate complex at 490 nm. In this way, iron is also determined. With the proposed system, molybdenum can be determined in plant and food digests within the 0-100 mug Mo 1(-1) range in the presence of up to 25 mg Fe 1(-1), at a sampling rate of about 50 determinations h(-1). The relative standard deviation of 10 consecutive measurements was estimated as < 2%. Results for samples were comparable with those obtained by graphite furnace atomic absorption spectrometry. In addition, recoveries within the range 94-100% were calculated.

8.
Talanta ; 40(10): 1529-34, 1993 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-18965816

RESUMO

A preconcentration procedure was established for sulphate determination in rain waters at the mg/l level, employing a small column packed with the AG1-X8 (200-400 mesh) anionic resin inserted into a flow injection system. Sulphate determination was performed by using the turbidimetric method based on reaction with barium. For concentrations within 0.10 and 2.0 MgSO(2-)(4)/l, a throughput of 50 determinations/hr was achieved, and the relative standard deviation of results was better than 2%.